Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Similar documents
NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Number of input channels

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Solid State Relays with Failure Detection Function

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Connecting Sockets, Mounting Brackets, DIN Rails

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Features various encoder interfaces and controls multiple analog servo drives at high speeds

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

S82S (3/7.5-W Models)

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

CSM_PYF S/P2RF- -S_DS_E_2_5

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Model A7BS

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Model Number Structure

Electroformed Probe Pins XP3A

Indicator (Square) Ultra Bright LED Type

Model NPN output PNP output Standard. configuration

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E4C-UDA CSM_E4C-UDA_DS_E_12_2

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

Indicator (Square) Ultra Bright LED Type

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model Number Structure

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NX-TS. NX-series Temperature Input Unit

NJ-Series Power Supply Unit NJ-PA/PD

CX-One Ver.4 CSM_CX-One_DS_E_8_2

M16-J M16-A M16-T

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Dimension A. Dimension B

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

CX-One Ver.4 CSM_CX-One_DS_E_10_2

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

NPN output. 200 mm. Type Cable length Model Remarks

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

Knob-type Selector Switches

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

NYM. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Practices Guide OMRON Standard IAG Library

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable)

Classification Applicable models Specification Type Model

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

NX-DA CSM_NX-DA_DS_E_3_1

CMOS Laser Sensor with Built-in Amplifier ZX0

NE1A/DST1. DeviceNet Safety System

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Photoelectric Sensor

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Model Number Structure

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

NX-SL/SI/SO. NX-series Safety Control Units. Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration.

Model NPN output PNP output Standard. configuration

D4GS-N CSM_D4GS-N_DS_E_7_4

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Model Number Structure

Intelligent Flag Amplifier

Model Number Structure

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

CSM_NX-PG0 DS_E_4_4

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_4

Transcription:

Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system from Standard Controllers across the network. EN954-1 (Cat.4), ISO13849-1 (PLe), and IEC 61508 SIL3 certification. The XD0808SL-1 also supports logic operation functions for high-speed processing in applications requiring partial stopping of the safety system. Ordering Information List of Models of I/O points Model Safety inputs: 12, test outputs: 4 ID12SL-1 Safety I/O s Safety inputs: 8, safety outputs (semiconductor): 8, test outputs: 4 MD16SL-1 XD0808SL-1 * Safety inputs: 4, safety outputs (relay): 4, test outputs: 4 MRD08SL-1 Note: The standard DS1T Safety I/O s are equipped with spring-cage terminal blocks, but screw terminal blocks are available if desired, e.g., to replace previous terminals. Refer to Safety Accessories. *Use the Network Configurator Ver. 2.0 or later to make XD0808SL-1 settings. Specifications Certified Standards Certification body TÜV Rheinland UL Standard NFPA 79-2012 EN ISO 13849-1:2008 IEC61131-2: 2007 EN ISO13849-2: 2012 EN61000-6-4: 2007 EN61000-6-2: 2005 EN60204-1: 2006 ISO 13850:2006 (EN418:1992) ANSI RIA15.06-1999 ANSI B11.19-2010 UL508 ANSI/ISA 12.12.01 (excluding the MRD08SL-1) UL1998 NFPA79 IEC61508 CSA22.2 142 CSA22.2 213 (excluding the MRD08SL-1) Specifications Model Item Communications power supply voltage I/O power supply voltage Current consumption Communications power supply I/O power supply * Overvoltage category Noise immunity Vibration resistance Shock resistance Mounting method Ambient operating temperature Ambient operating humidity ID12SL-1 MD16SL-1 MRD08SL-1 XD0808SL-1 11 to 25 VDC supplied via communications connector 20.4 to 26.4 VDC ( 15%/+10%) 100 ma 70 ma II 110 ma 50 ma 100 ma 80 ma 110 ma 50 ma Conforms to IEC61131-2. 10 to 57 Hz: 0.35-mm single amplitude, 57 to 150 Hz: 50 m/s 2 150 m/s 2, 11 ms 35-mm DIN Track 10 to 55 C 10% to 95% (with no condensation) 100 m/s 2, 11 ms 150 m/s 2, 11 ms 10% to 85% 10% to 95% (with no (with no condensation) condensation) Ambient storage temperature 40 to 70 C Degree of protection IP20 Weight 420 g 600 g 420 g *Not including power consumption for external devices. 1

DST1 Series Safety Input Specifications Input type ON voltage OFF voltage OFF current Input current Sinking inputs (PNP) 11 VDC min. 5 VDC max. 1 ma max. 6 ma Safety Output Specifications (Semiconductor output) (Common with the MD16SL-1/XD0808SL-1) Output type Sourcing outputs (PNP) Rated output current 0.5 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 ma max. Test Output Specifications Output type Sourcing outputs (PNP) Rated output current 0.7 A max./output ON residual voltage 1.2 V max. Leakage current 0.1 ma max. Safety Output Specifications (Relay Output) (MRD08SL-1) Applicable relays G7SA-2A2B, EN50205 Class A Failure rate P level * 5 VDC, 1 ma (Reference value) Rated load (resistive) 2 A at 240 VAC, 2 A at 30 VDC 5,000,000 operations min. Mechanical Durability 100,000 operations min. (at 7,200 operations/h) Electrical (at 1,800 operations/h with a resistive load) *This value is equivalent to 300 operations/minute. CIP Safety on Communications Safety Slave communications Max. 4 connections (Max. 2 connections for the XD0808SL-1) Slave Communications Standard Slave communications Max. 2 connections Internal Circuit Configuration ID12SL-1 Test Output Circuit V V IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 T2 T2 T2 T3 T3 T3 G G T0 T1 T0 T1 T0 T1 T0 T1 T0 T1 T0 T1 G G G G G G 1, 2 V Power supply terminal () 11, 12 G for input device and test output 35 to 40 G ( 11, 12 and 35 to 40 are internally connected.) 3 to 10 21 to 24 13 to 20 25 to 30 31 to 34 IN0 to IN11 T0 to T3 Safety input terminal Test output terminal 2

DST1 Series MD16SL-1 XD0808SL-1 Test Output Circuit Output Power Safety Output Circuit V0 V0 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 V1 V1 OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 G0 G0 T0 T1 T0 T1 T0 T1 T2 T3 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 1, 2 V0 Power supply terminal () for input device 11, 12 G0 and test output 3 to 10 IN0 to IN7 Safety input terminal 13 to 20 T0 to T3 Test output terminal 21, 22 V1 31, 32 G1 Power supply terminal () for output device 23 to 30 OUT0 to OUT7 Safety output terminal 33 to 40 G1 ( Nos. 31 to 40 are internally connected.) MRD08SL-1 Test Output Circuit Output Power Ry0 Ry1 Ry2 Ry3 V0 V0 IN0 IN1 IN2 IN3 T2 T2 T3 T3 V1 V1 OUT0 OUT0e OUT1 OUT1e OUT2 OUT2e OUT3 OUT3e G0 G0 T0 T1 T0 T1 G0 G0 G0 G0 G1 G1 C0 C0e C1 C1e C2 C2e C3 C3e 1, 2 11, 12 V0 G0 Power supply terminal () for input device, test output, and monitoring the safety relay NC contact of the internal circuit 17 to 20 G0 ( Nos. 11, 12 and 17 to 20 are internally connected.) 3 to 6 IN0 to IN3 Safety input terminal 7 to 10 13 to 16 T0 to T3 Test output terminal 21, 22 V1 Power supply terminal () for driving the 31, 32 G1 safety relay of the internal circuit 23 to 30 33 to 40 OUT0 to OUT3 C0 to C3 OUT0e to OUT3e C0e to C3e Safety output terminal (The outputs of terminal 23/33 (OUT0) and 24/ 34 (OUT0e) are the same.) (The outputs of terminal 25/35 (OUT1) and 26/ 36 (OUT1e) are the same.) (The outputs of terminal 27/37 (OUT2) and 28/ 38 (OUT2e) are the same.) (The outputs of terminal 29/39 (OUT3) and 30/ 40 (OUT3e) are the same.) Refer to the CIP Safety on series Safety I/O s Operation Manual (Cat. Z904) for wiring examples. 3

Dimensions ID12SL-1 MD16SL-1 XD0808SL-1 DST1 Series (Unit: mm) (68.15) 65 35.5 42.75 170 71.4 MRD08SL-1 (94.7) 90 35.5 63 170 83.2 Safety Precautions Refer to the "Safety Precautions for All CIP Safety on Systems" for precautions. Be sure to read the following user's manual for other details required for correct use of the Safety I/O s Safety I/O s User's Manual (Cat. Z904) 4

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2013.12 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.