SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

Similar documents
SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

RER 123 Bus Connection Module. Technical Description

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Synchro-check relay. Application

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Data communication and reporting unit

Residual overvoltage relay

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Earth-fault Relay SPAJ 110 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

Data communication and reporting unit

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

General characteristics of C-type relay modules

Arc protection relay. Features Three-phase overcurrent function. Application

Feeder protection relay SPAA 341 C. Product Guide

Feeder protection relay

SREDU Double Connection Option Card for Lon Star Coupler RER 111

Communication Gateway COM 610. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Communicate IT Software module DR-COM. Buyer s Guide

High impedance protection relay

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Relay setting toolbox

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

Feeder Protection Relay REF 610. Product Guide

Protection Relay RE_ 610. Installation Manual

Multiturn absolute encoder

MC 11 EB-2 Power supply cabinet with external bus, AC version

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Relay configuration and setting tool package

AS-Interface I/O Module

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Relay Product Engineering Tools

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

2-Way Wireless I/O Expander Installation Guide

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Manual Industry Interfaces

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

Communication with EuroProt-IED Multifunctional intelligent devices

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Converter Box Data Sheet

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

IF-80x Outdoor Terminal

Power Products. Protection and Control IED Manager PCM600 Product Guide

AIDON PRODUCT CATALOG

Fiber optic converter audio and CAN TA OPERATION MANUAL

Control Panel CP600 CP651, CP651-WEB

Manual Fiber Optic Interfaces

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Rako RAK4-R Instruction Manual

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Control Panel CP600-eCo CP604, CP604-B

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

FL MC 2000E (SM40) LC

SPAA 341 C Feeder protection relay

Control Panel CP600 CP635, CP635-B, CP635-WEB

TCNM-ACBB1 Installation Manual

REM 543 Machine Terminal. User s Guide for Modbus Configurations

PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Motor Protection Relay REM 610. Product Guide

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Industrial PoE Media Converter

Power Products. Station Automation COM600 Product Guide

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed).

LON bus LonWorks Network in Protection and Control Systems. User s manual and Technical description

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Protected VARAN Digital Mixed Module PVDM 086

Fibre Modem - Single-mode

SoundwebTM. Installation Guide

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Relion 610 series. Voltage Protection REU610 Product Guide

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

Grid Automation packaged solutions Optimal automation of medium voltage grids

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Operating instructions valve control box AS-i

Product data sheet accessories control and regulation Accessories AIRWIN

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Transcription:

SPA-ZC 17 Bus connection module User s manual and Technical description 1 2 3 4 5 6 7 8 O N SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx 2 5 Uaux 80...265 V ~ 18...80 V SPA-ZC 17 RS 951 014 Ser. No L N PE 1 2 3 4 5 6 BB BM MB MM Made in Finland POWER AUX. INT.

1MRS 751230-MUM EN Issued 99-02-16 Version A (replaces 34 SPACOM 7 EN1) Checked EP Approved EP SPA-ZC 17 Bus connection module Data subject to change without notice Contents General... 2 Operating principle... 3 Construction... 4 Optical/electrical connection... 5 Type designation key... 6 General The different devices of the SPACOM product range are connected to the optical SPA bus via bus connection modules. The bus connection module type SPA-ZC 17 converts the optical signals of the SPA bus to electrical RS 485 or SPA (+5 V) level signals and vice versa (see Fig. 1). The bus connection module is provided with a built-in power unit allowing the SPACOM device to be disconnected from the bus connection module, for instance, for service without interrupting the data communication over the optical loop. The bus connection module is mounted in a suitable place in the apparatus cabinet and the connection cable of the module is plugged to the D-type subminiature connector on the rear panel of the SPACOM device. The bus connection module type SPA-ZC 17 connects to any SPACOM device provided with a D-type subminiature connector. Separate mounting accessories are available for mounting the bus connection module to a SACO data communication and reporting system. 2

Operating principle The bus connection module SPA-ZC 17 is provided with a built-in power unit which is supplied from an external auxiliary power source. The auxiliary supply is galvanically separated from the electronics. Alternatively, the supply voltage can be obtained exclusively from the SPACOM host device which is to be connected to the SPA bus or it can be supplied both from an external power source and the host device simultaneously. The required data communication mode is selected with the DIP switches on the front panel of thebus connection module. 1 2 3 4 5 6 7 8 SPA communication mode 1 1 0 0 0 0 0 RS 485 0 0 1 1 1 1 0 Echoing enabled, slave device 0 1 No echoing, master device 0 0 The switches are in position 1, when the ON marked side of the switch has been pushed down. Switches 1 6 are used for selection of the mode of communication (SPA or RS 485) to be used. The mode of communication of the protection relays is shown in section "Connections" in the general part of the user's manual. operating properly. The LED marked INT is lit when the auxiliary voltage is supplied by the host device and the power unit is operating properly. The LED marked SC flashes at the rate of the data communication. Rx Tx SPA-ZC 17 Switch 7 is always to be in position 0. Echoing of the communication is selected with switch 8. When the bus connection module is connected to a slave unit switch 8 must be in position 1 (echoing enabled). When the bus connection module is connected to a master unit (e.g. type SRIO) switch 8 must be in position 0 (no echoing). Uaux RS 485 SPA The SPA-ZC 17 module is provided with diagnostic LEDs. The LED marked AUX indicates that the auxiliary voltage is supplied by an external power source and that the power unit is 9 Fig. 1. Block diagram of the bus connection module SPA-ZC 17. 3

Construction The bus connection module SPA-ZC 17 is assembled on a 92 mm x 95 mm PC board and housed in a sheet steel case. The module is usually mounted on the wall inside the apparatus cabinet by means of two M4 screws. The optical fibres are anchored to the plastic clip at the upper edge of the bus connection module and connected to the transmitter (Tx) and the receiver (Rx). The specific features of the fibreoptic cables must be noted, when the cables are being handled, mounted and connected. Detailed information is given in the user's manual 34 SPA 13 EN1 A "Plastic-core fibre optic cables. Features and instructions for mounting". The mechanical design and the dimension drawing are shown in Figs. 3 and 4. The length of the connection cable linking the bus connection module to the host device is 2 m. It is included in the delivery of the bus connection module. 174 146 5,5 0 0 52 SPA / RS 485 2 5 U aux 80...265 V ~ 18...80 V SPA RS 485 SLAVE MASTER SPA-ZC 17 RS 951 014 Ser. No 1100000 0011110 10 L N PE 6 1 2 3 4 5 Tx SC Rx BB BM MB MM POWER AUX. INT. Fig. 3. Dimensional drawing. 104 46 The dimension drawing of the D-connector terminating the cable is shown in Fig. 4. Lock washer Screw SPACOMdevice SPA-ZC17 41 Fig. 4. Earthing of the connection cable. Fig. 2. Mechanical construction 4

aux 1 O N 2 3 4 5 6 7 8 Optical/electrical connection The optical connections are based on plastic core or glass fibre cables or on both cable types. The SPA mode or the RS 485 mode is used in the communication between the SPACOM device and the bus connection module, depending of the SPACOM product. From one bus connection module to the other the information is conweyed via the fibre-optical cables. The connection cable is provided with 9-pin male D type subminiature connectors in both ends. One end is further provided with an earthing wire, which is connected to the fixing hole close to the D type connector on the rear panel of the SPACOM device using one 6 mm M3 screw, see Fig.4. The cable delivery set includes a svrew, a contact washer and a nut. The nut is not needed if the earthing wire is connected to the earthing hole. The external supply voltage and the protective earth wire are connected to their screw terminals, see Fig. 5. The power consumption of the bus connection module is approx. 2,5 W, when the power is supplied from an external source and approx. 0.6 W, when the supply is taken from the host device. The disturbance immunity class of the bus connection module SPA-ZC 17 is 3. SPACOM relay Sheathed cable Incoming and outgoing fibreoptic SPA bus SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx U 2 5 80...265 V ~ 18...80 V SPA-ZC 17 BB BM MB RS 951 014 MM Ser. No Made in Finland L N PE 1 2 3 4 5 6 POWER AUX. INT. Earthing wire of cable sheath U aux Earth Fig. 5. Mounting of the bus connection module. 5

Type designation key SPA-ZC17 MB 2 A External auxiliary supply: A = 80 265 V AC/DC C = 18 80 V DC Length of the connection cable of the bus connection module (constant) Optical receiver: B = plastic core M= glass fibre Optical transmitter: B = plastic core M= glass fibre Type Type designation Transmitter Receiver Auxiliary supply SPA-ZC 17BB2A PLASTIC PLASTIC 80 265 V AC,DC SPA-ZC 17BM2A PLASTIC GLASS 80 265 V AC,DC SPA-ZC 17MB2A GLASS PLASTIC 80 265 V AC,DC SPA-ZC 17MM2A GLASS GLASS 80 265 V AC,DC SPA-ZC 17BB2C PLASTIC PLASTIC 18 80 V DC SPA-ZC 17BM2C PLASTIC GLASS 18 80 V DC SPA-ZC 17MB2C GLASS PLASTIC 18 80 V DC SPA-ZC 17MM2C GLASS GLASS 18 80 V DC A type designation ending /S, for instance SPA-ZC 17 BB2A/S, implies that the cable delivered with bus connection module connects to a SACO control data communicator. 6

7

ABB Substation Automation Oy P.O.Box 699 FIN-65101 VAASA Finland Tel. +358 (0)10 22 4000 Fax.+358 (0)10 22 41094 www.abb.com/substationautomation 1MRS 751230-MUM EN