MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

Similar documents
MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Raising the Bar in IMRT QA

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

ADVANCING CANCER TREATMENT

DAILY LINAC QA BEAM QA

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

FAST, precise. qa software

3DVH FAQs. What is PDP questions

Quick Reference Datasheet For All RIT113 Packages

3D Scanning Comes Full Circle

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

Machine and Physics Data Guide

ADVANCING CANCER TREATMENT

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Version 3.7. User Manual

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

Dynalog data tool for IMRT plan verification

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Clinical implementation of photon beam flatness measurements to verify beam quality

Commissioning, beam matching and small field dosimetry experience with Elekta Versa

A NEW LASER FOCUS ON PATIENT SAFETY

Advanced Radiotherapy

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

Basic Radiation Oncology Physics

Virtual Phantoms for IGRT QA

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

PCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

Integrated proton-photon treatment planning

GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Beams You Up to a New Era in 3D Water Scanning.

IMRT site-specific procedure: Prostate (CHHiP)

The use of an on-board MV imager for plan verification of intensity modulated radiation therapy and volumetrically modulated arc therapy

Dosimetric Analysis Report

TOMOHD. Product Specifications

Anthropomorphic Verification of the Eclipse AAA Algorithm for Spine SBRT Treatments Involving Titanium Implants

PyCMSXiO: an external interface to script treatment plans for the Elekta CMS XiO treatment planning system

Real-time monitoring of linac performance using RT plans and logfiles

Medical Dosimetry 37 (2012) Medical Dosimetry. journal homepage:

Using a research real-time control interface to go beyond dynamic MLC tracking

Lucy Phantom MR Grid Evaluation

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures

Evaluation of detector array technology for the verification of advanced intensity-modulated radiotherapy

ph fax Deming Way Middleton WI USA

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Tumor motion during liver SBRT

Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Applications of Cone Beam Computed Tomography in Radiotherapy Treatment Planning

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

VALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

Basics of treatment planning II

TEPZZ Z754_7A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: A61N 5/10 ( )

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

Image Guidance and Beam Level Imaging in Digital Linacs

A dedicated tool for PET scanner simulations using FLUKA

ViewRay System Commissioning

Initial Clinical Experience with 3D Surface Image Guidance

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Verification measurements of an emc algorithm using a 2D ion chamber array

Table of Contents. About AQUA

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071

Three-dimensional dosimetry of TomoTherapy by MRI-based polymer gel technique

Verification of Varian enhanced dynamic wedge implementation in MasterPlan treatment planning system

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

REF User Manual DOC # STANDARD IMAGING, INC Deming Way Middleton, WI

Accuracy study. Elekta Synergy S. High precision radiation therapy using Elekta Synergy S. UMC, Utrecht, Netherlands. Institution: Purpose:

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

LUP. Lund University Publications. Institutional Repository of Lund University

Image Guided Multibeam Radiotherapy

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

S. Guru Prasad, Ph.D., DABR

Transcription:

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools

THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array. MapCHECK set the standard for modern, efficient and stringent QA, and enabled a new era of attainable IMRT. With MapCHECK 2 simply connect the single cable which supplies both power and data, and measure in high resolution 2D. It s that simple, and that powerful. 1 I www.lightages.com 2 SUN NUCLEAR CORPORATION // sunnuclear.com

Independent Measurement QA for Patient Plan, Dose, and Machine Testing MapCHECK 2 is the successor to the original MapCHECK and remains the world s most chosen 2D array. MapCHECK 2 provides the highest detector density, smallest detector size, and largest field size of any 2D array for IMRT QA. Over 1527 SunPoint Diode Detectors measure only 0.64 mm each, and measure up to a 32 x 26 cm field. SNC Patient software allows rapid analysis of QA measurements against plan, and 3DVH promotes those measurements to clinical 3D patient dose for comparison to the 3D patient plan. Patient Plan QA Stringent, fully independent measurement QA of patient plan and delivery with SNC Patient software Dose and DVH QA Full 3D Dose reconstruction for target and OAR DVH QA with 3DVH software Machine QA Machine QA for a wide variety of tests can be accomplished with MapCHECK 2 and PROFILER software SUN NUCLEAR CORPORATION // sunnuclear.com 3

MapCHECK 2 The Gold Standard for 2D Patient QA Features and Benefits 2D patient plan QA Conventional IMRT and 3D conformal 1,527 SunPoint Diode Detectors Smallest detector (0.019 mm 3 ) High sensitivity Less drift No dose volume average Field Size: 32.0 x 26.0 cm Real time electrometer measures every pulse with 50 ms updates Includes SNC Patient software Compare measured dose to planned dose with a single click Compare relative or absolute dose data using Distance-to-Agreement or Gamma Analysis Quick and reproducible isocentric measurements at any gantry angle with IMF or GMF 4 1 I www.lightages.com SUN NUCLEAR CORPORATION // sunnuclear.com

SNC Patient Software With a single mouse click, SNC Patient software compares measured dose points to planned dose points. Users can compare relative or absolute dose data using Distance-To-Agreement (DTA) or Gamma Analysis. Measured points that do not fit within the acceptance criteria are highlighted red for high dose and blue for low dose. Ease of Use Single power/data cable Manages all power and data in one connection Integrated electronics Self-contained with no separate electronics to set up Lightweight (7.1 kg) Patented user calibration Clinically proven Wide field Calibration (WFC) is performed on site and does not require disassembly of the MapCHECK device No pre-irradiation or warm-up required for absolute dose measurements SUN NUCLEAR CORPORATION // sunnuclear.com 5

3DVH Clinically Relevant and Patient-Specific QA 3DVH transforms the field of patient-specific dose QA by generating clinically-relevant and intuitive analyses of complex IMRT and VMAT plans. With proven accuracy, and powered by the patented Planned Dose Perturbation (PDP ) algorithm, 3DVH uses existing QA measurements to estimate 3D dose to the patient geometry. Clinicians can use the same methods to QA treatment plans as those which were used to create them. Features and Benefits Transform 2D measurements to 3D dose volume for advanced analysis Perform 3D dose and DVH QA analysis on patient not phantom geometry Supports coplanar and non-coplanar beams Identify TPS and beam delivery errors Intuitive and familiar presentation of dose and DVH with statistics per anatomical structure Fast results with automated tools Quick Stat Templates, Quick Dose Profiles, DICOM compliant workflow No forward dose calculation into the patient CT No commissioning Uses existing measurements and devices 6 1 I www.lightages.com SUN NUCLEAR CORPORATION // sunnuclear.com

Accessories MapPHAN A water equivalent phantom that adapts any MapCHECK 2 for RapidArc, VMAT, and TomoTherapy. Setup time is fast and measurement may occur in coronal and sagittal orientations. Construction: Virtual Water Available Depths (cm): 5.0, 10.0 Weight without MapCHECK 2: Area: (cm 2 ) 35.0 x 38.0 5 cm MapPHAN 8.0 kg 10 cm MapPHAN 21.0 kg IMF / GMF Measure at any gantry angle Fast, efficient, reproducible setup Measure at 100 cm SDD ± 0.5 mm Compatible with electron cones (GMF) Aluminum alloy construction Adjustable buildup clamps IMF pictured with MapCHECK 2 GMF SRS Film QA Co-developed with Accuray for CyberKnife, SRS Film QA provides film-based SRS, VMAT, and IMRT QA within SNC Patient software. Film images are converted to dose for any stereotactic modality, and compared against a treatment plan file. Analyze film as if it were MapCHECK measured data No H&D curve required Extract any arbitrary plane from a 3D dose object Verify phantom fiducials slice by slice EPSON flatbed scanner support Use with EBT film SUN NUCLEAR CORPORATION // sunnuclear.com 7

Specifications 7.07 mm Spacing, Entire Array 1527 Total Diodes 32.0 x 26.0 cm Array Size Power/Data Input Status Indicators Detector Type: Detector Quantity: 1527 Field Size: (cm) 32.0 x 26.0 Array Geometry: (cm) Detector Spacing: (mm) Active Detector Area: (mm 2 ) 0.64 Active Detector Volume: (mm 3 ) 0.019 Detector Sensitivity: (nc/gy) 32 Sampling Frequency: (ms) 50 Detector Stability: Max Dose/Pulse: (Gy) Dose Rate Dependence: SunPoint Diode Detectors Detector spacing parallel to X and Y axes: 1.0 Row spacing offset: 0.5 7.07 (uniform throughout array) 0.5%/ kgy at 6 MV (photons) 0.2 Gy Inherent Buildup: (g/cm 2 ) 2.0 ± 0.1 ± 1% over the range 50-1400 cgy/min Inherent Backscatter: (g/cm 2 ) 2.75 ± 0.1 Radiation Measured: Number of Connection Cables: Photons: Co-60 to 25 MV Electrons: 6 MeV to 25 MeV Single power/data cable Dimensions: L/W/H (cm) 28.7 x 56.0 x 4.3 Weight: (kg) 7.1 System Requirements (SNC Patient, EPIDose, 3DVH) Operating System: Windows 7, Windows 8.1 MapCHECK 2 Compatibility Rotational Therapy: RapidArc, VMAT, TomoHelical IMRT, TomoDirect, 3D Conformal, Dynamic Wedge Treatment Planning Systems: Pinnacle, Eclipse, Monaco, iplan, and any TPS system that can export DICOM data FFF & non-fff Deliveries 3DVH Compatibility Hardware: ArcCHECK, MapCHECK 2, Software: EPIDose, SNC Patient (included) Static Gantry: IMRT Treatment Planning Systems: Pinnacle, Eclipse, TomoTherapy, and most TPS systems that can export DICOM data CPU: RAM: Hard Drive Space: FFF & non-fff Deliveries Recommended 2.4 GHz or better, multi core (2 or more cores) Recommended 4 GB or more Recommended 5 GB or more RapidArc and Eclipse are trademarks of Varian Medical Systems, Inc.; TomoTherapy, TomoHelical and TomoDirect are all trademarks and/or registered trademarks of Accuray Incorporated. Pinnacle is a trademark of Philips. Monoco and iplan are trademarks of Elekta AB. MapCHECK_3DVH_D062016 sunnuclear.com // +1 321 259 6862 Corporate Headquarters: 3275 Suntree Boulevard, Melbourne, FL 32940 USA All data used is best available at time of publication. Data is subject to change without notice. 2016 Sun Nuclear Corporation. All Rights Reserved.