Configuring GeneMapper ID Software

Similar documents
Procedure for GeneMapper ID. 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software.

User Bulletin. GeneMapper ID Software v3.2.1 Patch. In This User Bulletin. Obtaining and Installing the GeneMapper ID Software v3.2.

GeneMapper ID-X Software

GeneMapper ID-X Software Version 1.2

Applied Biosystems TrueScience Aneuploidy STR Kits

ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping

Workflow Guide Slide(s) Topic 2-6 Importing Data and Labeling Samples 7-11 Processing Data Without an Allelic Ladder Processing Data With an

User Bulletin. GeneMapper ID-X Software Version Update. GeneMapper ID-X Software Version Verification. In this user bulletin.

Operating instructions for MixtureCalc v1.2 (Freeware Version)

GeneMarker HID Quick Start

Devyser QF-PCR. Guide to Sample Runs, Data Analysis & Results Interpretation

DIPSorter User Manual. In combination with Biotype s Mentype DIPplex PCR Amplification Kit Software version: 1.0.2

ABI PRISM GeneMapper Software Version 3.0. User s Manual

RELEASE NOTES TABLE OF CONTENTS SOFTWARE OVERVIEW

You will see the difference!

Procedure for DNA Database Analysis and Technical Review of Database Samples

Gene. The Biologist Friendly Software. Quickstart Guide

ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ)

User Bulletin. ABI PRISM 310 Genetic Analyzer. DRAFT February 6, :09 pm, A.fm. G5v2 Module for Use with Dye Set 33 (DS-33)

Getting Started Guide. HID Real-Time PCR Analysis Software Version 1.0 For 7500 Real-Time PCR System

About Data Collection Preferences. Before You Begin. Macintosh computer - Step One: Setting Folder Locations

NC SBI: Forensic Biology Section DNA SOP Effective Date: July 19, 2004 Title: FMBIO Analysis Revision 04

GeneMapper Software v3.5

Installing the GeneMapper Software and Creating a Matrix on the ABI PRISM 310 Genetic Analyzer

HID Real-Time PCR Analysis Software

Microsoft Office PowerPoint 2007: Basic Course 01 - Getting Started

Section 1 Establishing an Instrument Connection

TraceFinder Analysis Quick Reference Guide

GeneMapper Software v3.5

Applied Biosystems AutoCaller Software

FRAGMENT ANALYSIS USING ABI 3730/3730XL HANDBOOK. Fragment Analysis using ABI 3730/3730xL, 7-B406, version Devyser AB, 2018 Page 1 of 11

GeneMapper Software Version 3.5

Contributing Lists in Activity Center

WMI log collection using a non-admin domain user

Discover the CE you ve been missing.

User Bulletin. GeneMapper Software Version 4.1. In This User Bulletin. Overview This user bulletin supplements the GeneMapper Software v4.

Getting Started in Assembly Programming with Keil uvision and MSP432

PowerPoint Launching PowerPointX

Faber 6000/Faber 6000 Plus USB Driver Installation for Windows 7/10

Geneious Microsatellite Plugin. Biomatters Ltd

SPP Server Expansion Troubleshooting Guide

Navigate to Cognos Cognos Analytics supports all browsers with the exception of Microsoft Edge.

Web-based Configuration. First, setup motion detection windows in the web-based configuration of the camera.

cief Data Analysis Chapter Overview Chapter 12:

Navigate to Cognos Cognos Analytics supports all browsers with the exception of Microsoft Edge.

GeneMapper Software v.4.0 Uninstall Procedure

Discover the CE you ve been missing.

EXERCISE: GETTING STARTED WITH SAV

CEQ 8000 Series Fragment Analysis Training Guide

CONFIGURING LDAP. What is LDAP? Getting Started with LDAP

Genetic Analysis. Page 1

CODE: PND16 VERSION: REPLACED BY: AUTHORIZED BY: Page 1 of 20. Effective Date:

How to Add Word Heading Styles Explanation

Guide to running KASP genotyping on the BIO-RAD CFX-series instruments

Excel 2010 Charts and Graphs

Getting Started with LabVIEW Virtual Instruments

TraceFinder Analysis Quick Reference Guide

BD CellQuest Pro Acquisition Tutorial

Getting Started with Crazy Talk 6

Hello, welcome to this brief tutorial on accessing and playing Adobe Presenter video files.

tandem Summary Problem

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes

Profile Modeler Profile Modeler ( A SuperControl Product )

PowerPoint X. 1. The Project Gallery window with the PowerPoint presentation icon already selected. 2. Click on OK.

Student Manual. Cognos Analytics

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

USER GUIDE. PowerKB for Parature

Evoq 9 Content Managers Training Manual

APPLICATION INFORMATION

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

Creating a Dashboard Prompt

Mend for Eclipse quick start guide local analysis

2. This will bring you to a new window asking what type of policy you are inserting. Personal Policies. Commercial Policies. All Other Policies

Using Charts in a Presentation 6

CaliberRM 5.1 Integration for Describe Enterprise

Setting Windows File Associations to Open.JNLP Files Properly

Agilent Genomic Workbench 7.0

PowerPoint 2 (Office 2007)

Managing Automation for SAP BOBJ Enterprise Processes

How to run a qpcr plate on QuantStudio 6

EE 210 Lab Assignment #2: Intro to PSPICE

E. coli functional genotyping: predicting phenotypic traits from whole genome sequences

SequencePro Data Analysis Application. User Guide

Troubleshooting in Microsoft Excel 2002

This document describes the flow of creating UPK content from start to finish.

Managing a Website in the EDUPE Environment

NCSBI Forensic Biology Section DNA SOP Effective Date: January 30, 2007 Title: ABI PRISM 7000: DNA Quantitation Revision 02

More Skills 11 Format and Position Report Controls

Multivariate Calibration Quick Guide

Filtering - Zimbra

The following instructions cover how to edit an existing report in IBM Cognos Analytics.

CONFIGURING ENTERGROUP. What is LDAP? Getting Started with LDAP

Chapter 6.0. Chapter 6.0 Eddy Current Examples. 6.1 Asymmetrical Conductor with a Hole. Ansoft Maxwell 3D Field Simulator v11 User s Guide

Downloading and editing signatures!

USC Marshall School of Business Marshall Information Services. Outlook 2013 Sharing Calendars. 1.1 Delegate Access

TinLof Technologies - PagePack / PageConnect Program Installation Guide *** Program must be installed on a PC (Non-Mac)

Excel window. This will open the Tools menu. Select. from this list, Figure 3. This will launch a window that

Enterprise Claims Department An Overview of the Team SharePoint

Instructions for Formatting MLA Style Papers in Microsoft Word 2010

To complete this database, you will need the following file:

Transcription:

Configuring GeneMapper ID Software using Advanced algorithm analysis Importing the Panels and Bins In order to successfully genotype AmpFlSTR kit samples, the panels and bins must be imported. The panels contain: marker size ranges dye label color expected positive control genotypes stutter percentages The bins are 1 bp wide regions within the marker size ranges where we expect the most common alleles to fall. During analysis of the allelic ladder, these bins will be offset based on the actual sizes obtained for all of the alleles in the allelic ladder(s). This accounts for variation in mobility from run to run, instrument to instrument, and platform to platform. Panels and bins for all Applied Biosystems validated STR amplification kits are installed with the GeneMapper ID software or available for download from our website. However, they will first need to be imported into the Panel Manager. 3. In the left navigation pane of the panel manager, highlight (one mouse click) the top Panel Manager node as shown below: 4. From the File menu, select Import Panels. 5. The Panels folder will open. Select the AmpFlSTR_Panels_v1.txt and click Import as shown below: Follow the steps below to import the panels and bins: 1. Launch the GeneMapper ID software 2. From the Tools Menu within the main project window, select Panel Manager. The panel manager will open.

6. In the left navigation pane, you will now see the AmpFlSTR_Panels. Highlight the AmpFlSTR panels folder in the left navigation pane as shown below: 9. At the bottom of the panel manager window, click Apply. This saves the panel and bin information into the GeneMapper ID database. Note! If you do not click Apply, the information will not be saved, and will not be accessible for data analysis. 10.At the bottom of the panel manager window, click OK. This closes the panel manager window and saves the imports performed. 7. From the File menu, select Import Binset. 8. The Panels folder will open. Select AmpFlSTR_Bins_v1.txt and click Import as shown below: Yfiler Panels and Bins Yfiler Panels and Bins were provided during the GeneMapper ID software installation. These will need to be imported into the Panel Manager following the same steps as outlined in the previous section. For step 5, select AmpFlSTR_Yfiler_Panel_v1.txt. For step 8, select AmpFlSTR_Yfiler_Bin_v1.txt. CODIS Panels and Bins Updated CODIS Panels and Bins (v1.1) are available for download from our Applied Biosystems website. These will need to be imported into the Panel Manager following the same steps as outlined in the previous section. The only exception is in Steps 5 and 8 in which the files will be found in the location selected during download.

Creating an Analysis Method for Advanced Algorithm Analysis An analysis method contains peak detection parameters, the binset to be used, filtering parameters, and quality assessment parameters. Data evaluation/validation must be performed to optimize all of these features. For the purpose of initial software set-up, only the peak detection parameters and selection of the AmpFlSTR binset are necessary. 5. Click OK. The Analysis Method Editor will open. 6. Fill out the general tab as shown below. The red box indicates where changes have been made. All other fields have been left blank or as default. Follow the steps below to create an Advanced Analysis Method: 1. From the main project window in GeneMapper ID, go to the Tools menu, and select GeneMapper Manager. 2. Once the GeneMapper Manager is open, click on the Analysis Methods tab. 3. Click New from the bottom left hand corner. 4. Select HID as the analysis type as shown below: DO NOT CLICK OK. This will close the window completely. 7. Click on the Allele tab.

8. Fill out the Allele tab as shown below: For Dye Set F: For Dye Set G5: 9. Click on the Peak Detection tab. 10. Fill out the Peak Detection tab as shown to the right. The Advanced peak detection algorithm should be selected by default. The peak amplitude threshold will need to be determined based on sensitivity of the instrument during validation experiments. For the purposes of this software configuration, leave as default (50). 11. For the purposes of this software configuration, the settings contained within the Peak Quality and Quality Flags tab can be left at the default values. 12. Click OK in the bottom on the Analysis Method Editor window. This will close the Analysis Method Editor. The newly created Analysis Method will be listed in the Analysis Method tab of the GeneMapper Manager window and accessible for data analysis. 13. Leave the GeneMapper Manager open for the next section.

Yfiler Analysis Method The same steps as listed in the previous section need to be followed with the exception of Steps 6 and 9. CODIS Analysis Method The same steps as listed in the previous section need to be followed with the exception of Steps 6 and 9. Step 6 change name of Analysis Method to Yfiler Analysis Method. Step 8 fill out the Allele tab as follows: Step 6 change name of Analysis Method to CODIS Analysis Method. Step 9 select AmpFlSTR_Bins_v1.1_codis.txt from the Binset drop down box. Importing Table Settings A table focusing on HID analysis has been installed with the GeneMapper ID software and needs to be imported into the GeneMapper Manager. This table will provide a start point to include the HID related information. Additional tables can be created to display only the information of interest. Step 9 select AmpFlSTR_Yfiler_Bins_v1.txt from the Binset drop down box. Follow the steps below to import the table setting: 1. Click on the Table Settings tab within the GeneMapper Manager. 2. From the bottom of the window, click Import. 3. The GeneMapper folder opens. Double-click the Table Settings folder.

4. Choose the AmpFlSTR Table and click Import as shown below: Follow the steps below to import the plot settings: 1. Click on the Plot Settings tab within the GeneMapper Manager. 2. From the bottom of the window, click Import. 3. The GeneMapper folder opens. Double-click the Plot Settings folder. 4. Choose the AmpFlSTR Genotyping and click Import as shown below: Note! Each plot setting must be imported separately. The table setting is now imported into the GeneMapper ID database and will be available for use. 5. Import the remaining plot settings shown above one at a time. 6. Leave the GeneMapper Manager window open for the next section. Importing Plot Settings Numerous Plot Settings are provided in the GeneMapper ID software and will need to be imported into the GeneMapper Manager. The selected features in these plot settings focus on HID analysis. Additional customized plot settings can be created to display only the information of interest. The table setting is now imported into the GeneMapper ID database and will be available for use. 5. Import the remaining plot settings shown above one at a time. 6. Leave the GeneMapper Manager window open for the next section.

Size Standards The software is provided with 4 default size standard definitions imported into the size standards tab of the GeneMapper manager that can be used with the Advanced analysis method. The default size standards include: Follow the steps below to set the options: 1. From the Tools menu of the main project window, select Options. 2. The first tab displayed is the Start Up tab. Leave this set to Blank Project. 3. Click on the Add Samples Tab. 4. Completing the tab as follows sets up analysis defaults which allow the user to analyze 5 dye chemistry (Identifiler and Yfiler). Setting Software Options User preferences are selected in the Options. These preferences will be configured only for the user name that is currently logged in (gmid is the default user name). Therefore if new user names are created, the options will need to be customized individually.

or, for 4 dye chemistry kits (Profiler Plus, Cofiler) see below: Note! It is always best to have the matrix applied within data collection through the injection list. For this reason, we indicate within the tab above to Read from the Sample. 5. For the purpose of this software set-up, leave the other tabs as default. You have now configured the GeneMapper ID software for AmpFlSTR kit analysis. 2006 Applied Biosystems. All rights reserved. Printed in the USA, 03/2006 Publication 112MI21-01