NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Similar documents
NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

Network Automation Engine

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

Network Integration Engine

Network Integration Engine Product Bulletin

Network Control Engine Catalog Page

Application and Data Server (ADS) Lite-A System Catalog Page

NxE85 Commissioning Guide

Network Control Engine

Network Integration Engine (NIEx9) for Third-Party Integrations Product Bulletin

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

Metasys N1 Network Integration

LCS85 Product Bulletin

Input/Output Module (IOM) Series Catalog Page

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

Advanced Application Field Equipment Controller (FAC) Catalog Page

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

Smart Equipment Controls (SEC)

Industrial PC - VL BPC

FX Input/Output (I/O) Modules XM07 and XM14

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

Metasys For Validated Environments, Extended Architecture Catalog Page

TALON Network Manager- 2 & 6 Express

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

TC Modular Series for BACnet Networks

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Supervisory Controllers

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

Cisco MCS 7825-H3. Supported Cisco Applications

Junos WebApp Secure 5.0 Hardware Guide

Metasys System Configuration Tool (SCT)

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

Altos T310 F3 Specifications

Cisco MCS 7825-I1 Unified CallManager Appliance

Overview. Applications. Features

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

FX06 Field Controller

Application and Data Server (ADS) Lite-E Catalog Page

Metasys for Validated Environments, Extended Architecture Catalog Page

FX-PCA Advanced Application Programmable Controller Catalog Page

Product Description. FX22, FX62, and FX70 Supervisory Controllers

Cisco MCS 7816-H3 Unified Communications Manager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance

J-201 Resource Capacity Guidelines and Sample Application Analysis

Application and Data Server (ADS/ADX) Ready Computer Systems Product Bulletin

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Metasys System Extended Architecture Overview

Field selectable application type and room module series, via dip-switches on controller

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Advanced Graphics Application Catalog Page

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6

x86 2U 19-inch rackmount computers with 2nd Gen Intel Celeron or Core i7 CPU, 6 Gigabit Ethernet ports, and 2 PCI expansion slots

clarity 3 Programmable Controller

Example for a VISONIK system configuration:

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

NCE25 Installation Instructions MS-NCE25xx-x

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications

Introducing the Cisco 1121 Secure Access Control System Hardware

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

HAWK 8000 Controller GENERAL. Product Data. Fig. 1. HAWK 8000

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

System Configuration Guide

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Cisco MCS 7815-I2 Unified CallManager Appliance

TC Compact Series for BACnet Networks

High Performance Computing

Dell Inspiron 300/400 Comprehensive Specifications

Andover ContinuumTM. b3850 Series Terminal Controllers

TALON Network Manager

INDUSTRIAL PC MOUNTED IN PANEL

Web server. Simplified.

DIRIS Digiware D and C Communication and control power interfaces

BM3300. Fanless Book Mounting IPC based on Intel Skylake U platform

EC-BOS-8 Multi-protocol Web Building Controller

Fujitsu PRIMERGY TX100 S2 Server

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

Savant Call Server: SCS-3000

PEAK TM. SMART Equipment Controllers. Product bulletin

EC-BOS-8 Multi-protocol Web Building Controller

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

IT and Interface Requirements

Comprehensive User/Group Security Restrict or allow access to myriad of points based on individual or group credentials

NEC Express5800/R120e-1M System Configuration Guide

TC-9102 Terminal Controller

Metasys System Software Purchase Options Product Bulletin

Features and Benefits. Certifications

Web interface BACnet/IP

Transcription:

Virtual Branch ecatalogue click here Metasys Network Automation Engine Network Automation Engines (s) enable Internet Protocol (IP) connectivity and web-based access to Metasys Building Management Systems (BMSs). s leverage standard building management communication technologies, including BACnet protocol, LonWorks network, and N2 Bus protocol to monitor and supervise a wide variety of Heating, Ventilating and Air Conditioning (HVAC); lighting, security, fire and access control equipment. s provide comprehensive equipment monitoring and control, scheduling, alarm and event management, energy management, data exchange, data trending and data storage. s feature an embedded site management portal user interface, support multiple concurrent web browser sessions with password and permission access control and provide the protection of industry standard Information Technology (IT) security. 55 models support a comprehensive set of supervisory features and functions for large facilities and technically advanced buildings and complexes. The 35/45 models enable cost-effective connectivity and control in smaller facilities, and can extend supervisory functions in larger facilities. The 85 is a high-capacity that allows integration of large BACnet IP systems and can take the place of multiple s. 55 Network Automation Engine 45 Network Automation Engine Features ffcommunication using commonly accepted IT standards at the automation and enterprise level ffweb-based user interface ffsite director function ffsupport for web services at the automation network level ffuser interface and online system configuration software embedded in ffsupervision of field controller networks including BACnet MS/TP, N2 Bus, LonWorks Network and BACnet IP Devices ffmultiple connection options for data access 146

Ordering information 35 MS-35xx-xxx (Base Features of Each 35) MS-3510-2 MS-3511-2 MS-3514-2 MS-3515-2 MS-3520-2 MS-3521-2 MS-3524-2 MS-3525-2 45 MS-45xx-xxx (Base Features of Each 45) MS-4510-2 MS-4511-2 MS-4520-2 MS-4521-2 35 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 data protection battery. Supports one N2 or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports up to 50 devices on the N2 or BACnet MS/TP trunk. Supports one N2 or BACnet MS/TP (RS-485) trunk (RS-485 port); includes an internal modem; supports up to 50 devices on the N2 or BACnet MS/TP trunk. Supports one N2 or BACnet MS/TP (RS-485) trunk; features basic access support; includes an additional RS-232-C serial port for optional external modem; supports up to 50 devices on the N2 or BACnet MS/TP trunk. Supports one N2 or BACnet MS/TP (RS-485) trunk; features basic access support; includes an internal modem; supports up to 50 devices on the N2 or BACnet MS/TP trunk. Supports one LonWorks trunk, includes an additional RS-232-C serial port for optional external modem. Supports up to 64 devices on the LonWorks port. Supports one LonWorks trunk, includes an internal modem. Supports up to 64 devices on the LonWorks port. Supports one LonWorks trunk, features Basic Access support, and includes an additional RS-232-C serial port for optional external modem. Supports up to 64 devices on the LonWorks trunks. Supports one LonWorks trunk, features Basic Access support, and includes an internal modem. Supports up to 64 devices on the LonWorks trunks. 45 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 data protection battery. Supports one N2 or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports up to 100 devices on the N2 or BACnet MS/TP trunk. Supports one N2 or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports up to 100 devices on the N2 or BACnet MS/TP trunk. Supports one LonWorks trunk, includes an additional RS-232-C serial port for optional external modem; supports up to 127 devices on the LonWorks port. Supports one LonWorks trunk, includes an internal modem; supports up to 127 devices on the LonWorks port. 147

Ordering information 55 MS-55xx-x (Base Features of each 55) MS-5510-3E MS-5511-3E MS-5520-3E MS-5521-3E 55 Network Automation Engines: Requires a 24 VAC power supply. Each model includes two RS-232-C serial ports, two USB serial ports, two RS-485 ports, one Ethernet port and one MS-BAT1010-0 Data Protection Battery. Supports up to 100 devices on each N2 or BACnet MS/TP trunk. Supports two N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk). Supports two N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk); includes an internal modem. Supports a LonWorks trunk, and two N2 trunks or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk). Supports up to 255 devices on the LonWorks trunk. Supports a LonWorks trunk, and two N2 trunks or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet MS/TP trunk); includes an internal modem. Supports up to 255 devices on the LonWorks trunk. Note Network engines with -3(E) ordering code suffix support Metasys Release 7.0.7 or later only 85 MS-NIE8500-0 * MS-NxE85SW-0 NxE85 model with 1U chassis for mounting in a server rack. Note: The 85 models ship as MS-NIE8500-0 models. Use the ChangeModel utility in the NxE85 Metasys software to change an NIE85 to an 85. NxE85 software for 10,000 objects (new projects only software). Note * Standard NxE85 models supports 10,000 objects; an upgrade is available to support an additional 15,000 objects. Accessories MS-BAT1010-0 MS-BAT1020-0 MS-15KUPG-0 MS-MULTENGSW-6 MS-EXPORT-0 SC450RM1U (OEM Part No.) Replacement data protection battery for 55 and NIE55. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21 C Replacement data protection battery for 35, 45, and NCE25. Rechargeable NiMH battery: 3.6 V 500 mah, with a typical life of 10 years at 21 C 15,000 object upgrade for NxE85 Network Engine Image Upgrade for all /NIE/NCE Engines on a Site, Excluding NxE85 Export Utility extracts historical trend, alarm, and audit data from the system and presents the historical data in a variety of formats. Note: This option is not necessary for sites that have an ADS/ADX that is the Site Director because Export Utility is provided with the ADS/ADX solution. Recommended Uninterruptable Power Supply (UPS) for NxE85 model: American Power Conversion (APC ) Smart-UPS SC 450VA, 280 W 120 VAC input/output with NEMA 5-15R output connections 148

Technical specification 35 and 45 Power requirement Power consumption Ambient operating conditions Ambient storage conditions Data protection Processor Memory Operating system Network and serial interfaces Dedicated nominal 24 VAC, Class 2 power supply (North America), Safety Extra- Low Voltage (SELV) power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 25 VA maximum 0 to 50 C; 10 to 90% RH, 30 C maximum dew point -40 to 70 C; 5 to 95% RH, 30 C maximum dew point Supports data protection on power failure. Rechargeable NiMH battery: 3.6 VDC 500 mah, with a typical life of 5 to 7 years at 21 C; Product Code Number: MS-BAT1020-0 192 MHz Renesas SH4 7760 RISC processor 128 MB Flash nonvolatile memory for operating system, configuration data, and operations data storage and backup 128 MB Synchronous Dynamic Random Access Memory (SDRAM) for operations data dynamic memory Microsoft Windows CE embedded One Ethernet port; connects at 10 or 100 Mbps; 8-pin RJ-45 connector One optically isolated RS-485 port; 9.6k, 19.2k, 38.4k, or 76.8k baud (depending on protocol); with a pluggable and keyed 4-position terminal block (FC Bus available on 351x and 451x models only) One LonWorks port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LonWorks port available on 352x-x and 452x models only) One RS-232-C serial port with standard 9-pin sub-d connector that supports standard baud rates. A second serial port, on models without an internal modem, that supports an optional, user-supplied external modem. One USB serial port with standard USB connector that supports an optional, user-supplied external modem. Option: One telephone port for internal modem; up to 56 Kbps; 6-pin modular connector ( models with an optional internal modem have one RS-232-C serial port only.) Housing Plastic housing material ABS + polycarbonate UL94-5VB Protection IP20 (IEC 60529) Mounting On flat surface with screws on three mounting clips or a single 35 mm DIN rail Dimensions (H x W x D) 131 x 270 x 62 mm Minimum space for mounting 35 and 45: 210 x 350 x 110 mm Shipping Weight 1.2 kg Compliance Johnson Controls International Plc, declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive and Low Voltage Directive. 149

Technical specification 55xx-3E Power requirement Dedicated nominal 24 VAC, Class 2 power supply (North America), Safety Extra-Low Voltage (SELV) power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) Power consumption 50 VA maximum Ambient operating conditions 0 to 50 C; 10 to 90% RH, 30 C maximum dew point Ambient storage conditions -40 to 70 C; 5 to 95% RH, 30 C maximum dew point Data protection battery Supports data protection on power failure. Rechargeable gel cell battery: 12 V, 1.2 Ah with a typical life of 3 to 5 years at 21 C; Product Code Number: MS-BAT1010-0 Clock battery Maintains real-time clock through a power failure. Onboard cell; typical life 10 years at 21 C Processor 1.46 GHz Intel Atom Bay Trail E3815 processor Memory 16 GB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup. 4GB DDR3 SDRAM for operations data dynamic memory Operating system Johnson Controls OEM Version of Microsoft Windows Embedded Standard 7 with SP1 (WES7) Network and serial interfaces One Ethernet port; 10/100/1,000 Mbps; 8-pin RJ-45 connector Two optically isolated RS-485 ports; 9,600, 19.2k, 38.4k, or 76.8k baud; pluggable and keyed 4 position terminal blocks (RS-485 terminal blocks available on 55 models only). Two RS-232-C serial ports, with standard 9-pin sub-d connectors, that support all standard baud rates. Two USB 2.0 serial ports; standard USB connectors support an optional, user-supplied external modem. Options: One telephone port for internal modem; up to 56 kbps; 6-pin RJ-12 connector. One LonWorks port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LonWorks port available on 552x-x models only) Housing Plastic housing With internal metal shield Plastic material ABS + polycarbonate; Protection: IP20 (IEC 60529) Mounting On flat surface with screws on four mounting feet or on dual 35 mm DIN rail Dimensions (H x W x D) 226 x 332 x 96.5 mm including mounting feet Minimum space for mounting: 303 x 408 x 148 mm Shipping weight 2.9 kg Compliance Johnson Controls International Plc, declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive and Low Voltage Directive. 150

Technical specification 85 software system requirements for installation/upgrade Product code Recommended computer platform Hard Disk Recommended memory Supported Operating Systems (OS) and software Internal optical drive Supported Operating Systems for Metasys client computers MS-NxE85SW-0: NxE85 software for 10,000 objects (new projects only software) Intel Xeon E5506, 2.13 GHz, 4 MB Cache 2 x 160 GB 7.2K, 8.9 cm cabled 3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS controller) 160 GB minimum 2 GB RAM minimum Windows Server 2012 R2 Editions Microsoft.NET Framework Version 3.5 Service Pack (SP) 1 Windows Server 2012 Editions Microsoft.NET Framework Version 3.5 SP Windows Server 2008 R2 Standard and Enterprise Editions with SP1 Microsoft.NET Framework Version 3.5 SP Windows Server 2008 R2 Web Edition with SP1 Microsoft.NET Framework Version 3.5 SP Windows Server 2008 Standard and Enterprise Editions with SP2 (32-bit) Note: Microsoft.NET Framework Version 3.5 SP 1 is required for each operating system. DVD ROM, SATA Windows 8.1 Pro and Windows 8.1 Enterprise Editions (64-bit) Windows 8 Pro and Windows 8 Enterprise Editions (64-bit) Windows 7 Professional, Enterprise, and Ultimate Editions with SP1 (32-bit or 64-bit) Apple OS X 10.8 Mountain Lion Apple OS X 10.9 Mavericks Note: Apple operating systems are supported for Metasys client computers only. Note: In Apple OS X, you cannot view Graphics+ graphics in the Site Management Portal UI. Recommended antivirus software Symantec Endpoint Protection Version 12 Supported Virtual Environments Microsoft Hyper-V, VMWare Network communication Network interface Single Ethernet network interface card 10/100/1000 Mbps (100 Mbps or better recommended) Recommended data protection Uninterruptible power supply (UPS) Smart-UPS SC 450VA, 280 W, 120 VAC input/output, NEMA 5-15R output connections, OEM Part No. SC450RM1U 151