Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Similar documents
Industry leading low energy evaporative fresh air cooling.

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Case Study Leicester City Council

Repeatable IT Hub Rooms

Case Study The University of Warwick

Repeatable IT Hub Rooms

Thermal management. Thermal management

Case Study Host Europe Group

APC by Schneider Electric Elite Data Centre Partner

Data centre solutions - energy efficient by design

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

MSYS 4480 AC Systems Winter 2015

Planning a Green Datacenter

MEASURE MONITOR UNDERSTAND

CASE STUDIES ENERGY EFFICIENT DATA CENTRES

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Engineering & Support Services

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Switch to Perfection

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Planned Preventative Maintenance Schedule. Raised Access Floor PPM Schedule

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Total Modular Data Centre Solutions

CASE STUDIES ENERGY EFFICIENT COOLING FOR THE PUBLIC SECTOR

ENCLOSURE HEAT DISSIPATION

Power and Cooling for Ultra-High Density Racks and Blade Servers

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Introducing the Heat Wheel to the Data Center

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Scalable, Secure. Jason Rylands

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Google s Green Data Centers: Network POP Case Study

Impact of Air Containment Systems

IT Air Conditioning Units

Green Data Centers A Guideline

Ecotel Free Cool 5-15kW

Rittal Cooling Solutions A. Tropp

A separate CRAC Unit plant zone was created between the external façade and the technical space.

Efficiency of Data Center cooling

Indirect Adiabatic and Evaporative Data Centre Cooling

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Virtualization and consolidation

Taking The Heat Off University of East Anglia Data Centre

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Close Coupled Cooling for Datacentres

INNOVATE DESIGN APPLY.

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Green Approach. Thermal

Indirect Adiabatic and Evaporative Data Center Cooling

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Data Center Energy Savings By the numbers

Liebert DCW CATALOGUE

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Reducing Energy Consumption with

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Recapture Capacity for Existing. and Airflow Optimization

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

INNOVATE DESIGN APPLY.

DAX Directional Airflow exhaust system. Energy efficient heat removal and redistribution. Product overview and technical data

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

APC APPLICATION NOTE #146

FREEING HPC FROM THE DATACENTRE

Reducing Data Center Cooling Costs through Airflow Containment

The Energy. David L. Moss Dell Data Center Infrastructure

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Data Center Energy and Cost Saving Evaluation

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Precision Cooling Mission Critical Air Handling Units

LCP Hybrid Efficient performance with heat pipe technology

Data Centre Optimisation Services

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

84 kw, Tier 3, Direct Expansion, 937 ft 2

Close-coupled cooling

FCU (FREE COOLING UNIT)

Precision Cooling. Precision Cooling Advantages

Green IT and Green DC

Ecoflair Air Economizers

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Overcoming the Challenges of Server Virtualisation

18 th National Award for Excellence in Energy Management. July 27, 2017

Transcription:

Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment

data centre free air cooling technology FreeCool - Evaporative Free Air Cooling Solution by Workspace Technology Ltd. FreeCool Evaporative Free Air Cooling is a low cost, low carbon alternative to traditional DX or Chilled Water cooling solutions for server room and data centre environments. FreeCool can be installed as new, or retrofitted within existing data centres, fitting in with current hot and cold aisle configurations. This solution will deliver <8Kw per rack when combined with FlexAisle aisle containment and airflow management systems. Traditionally the percentage of energy costs associated with cooling data centres is high. The deployment of FreeCool delivers significant energy reductions for data centre and server room cooling. The operating costs of Workspace Technology s FreeCool evaporative free air cooling solutions are up to 90% less than other traditional air conditioning technologies. In the past air economizer cooling solutions have been dismissed for server room and data centre environments due to historical issues with air quality and humidity control. Workspace Technology s FreeCool challenges the barriers to air economizer cooling as a suitable technology for server room and data centre environments. The barriers to air exchange have been removed as modern computing equipment is much more robust with regards to both temperature and humidity. Typical computer manufacturer environmental operating specifications are 10ºC to 35ºC and 10% to 95% relative humidity. ASHREA* have acknowledged the advances of modern computers and the need to balance energy efficiency against system reliability. Recently published ASHREA documents make recommendations for a server room temperature range of 18ºC to 27ºC, it is recommended that humidity levels are replaced with dew point. The use of high specification filters removes smaller particulates associated with construction, traffic, industrial processes and other pollutants. The resultant cleanliness of outdoor air from FreeCool is suitably appropriate for delivery within data centre environments. 2

FreeCool Installation Benefits FreeCool evaporative free air cooling technology makes the use of external air to cool server room and data centre equipment. Unlike simple air economizers which require supplemental DX or Chilled water cooling when external ambient temperatures exceed 21ºC the FreeCool system engages the evaporative cooling mechanism which reduces external air temperature by simply passing the airflow through wet filter pads. FreeCool deployment benefits include:- Reduced CO 2 emissions Significantly reduced energy consumption and operating costs Supports existing cooling technologies Improved DCiE / PUE ** Efficiency Ratings Improved company Green Credentials Improved resilience with practical support by UPS systems. Flexible airflow configuration options * ASHREA - American Society for Heating, Refrigeration and air-conditioning ** Data Centre Infrastructure Efficiency / Power Usage Effectiveness are industry recognized standards for data centre room efficiency measurement introduced by the Green Grid. 3

FreeCool Airflow Schematic (with aisle containment) FreeCool Evaporative Free Air Cooling Technology Overview Workspace Technology s FreeCool evaporative free air economizer technology delivers consistent equipment inlet temperatures of 21ºC to 24ºC depending on client preferences. The dew point temperatures simply do not become an issue due to the practical working temperatures. FreeCool takes external air and passes it to the raised access floor void via a ducting arrangement. Sensors located within the data centre accurately measure the equipment inlet temperatures. To ensure constant inlet temperatures are maintained the FreeCool controller generates air re-circulation from the hot aisle via a simple variable speed fan arrangement. When external ambient temperatures are above 21 C FreeCool engages the evaporative cooling circuit to provide air which never exceeds 22 C. For maximum energy efficiency it is recommended that FreeCool is deployed in combination Workspace Technology s FlexAisle aisle containment which eliminates the mixing of hot and cold airflows within the Data Centre. The separation of airflows will ensure that the evaporative circuit is only engaged when absolutely required. The example shown above is based on a Hot Aisle Return Plenum configuration. Hot exhaust air is extracted via the ceiling plenum to outside space. 4

1 Fresh air is brought into the system though primary filtration and wetted filter pads 2 Water detection provides additional security 3 Filters remove airborne particles 4 Isolation damper is linked to fire system 5 Cool air is fed into void under raised floor 6 Temperature compliant air is fed into cold aisle 7 Warm air from hot aisle is re-circulated to heat incoming air when ambient temperatures are below set point temperature to maintain constant inlet temperature. 8 Hot air is extracted and exhausted to outside of building FreeCool Typical Airflow Schematic 5

1 FreeCool evaporative free air coolers are externally fixed 2 N+1 systems provide system redundancy levels 3 Existing CRAC systems can be retained 4 Air is supplied to the underside of the raised floor. 5 Standby generators only have to support 10% of the electricity consumption of the CRAC systems. Typically FreeCool systems can be maintained with UPS support only. 6 UPS rooms are cooled with simple ventilation systems utilising evaporative cooling 7 FreeCool units are linked to all fire systems for controlled shut-downs. 8 Typical room mounted FreeCool unit. FreeCool Practical installation 6

FreeCool Circulation System Principle of Evaporative Free Air Cooling FreeCool uses an evaporative heat exchange process to cool air. This process takes advantage of the principle that free latent heat is generated as a result of water evaporation. This evaporative heat exchange system simply reduces the air temperature as it passes through the water filter. When compared to air-conditioning which uses mechanical refrigeration, the operating cost of evaporative heat exchange can be up to 90% less than traditional air conditioning. Water is brought into the cooler from the mains water supply and is pumped up to the top of the unit using a circulation pump. The water is then dispersed over CELdek pads using a water distribution system which allows the water to flow continually over the pad. The pads become saturated, air is drawn through the pads and the water evaporates naturally causing the air to cool. The cool air is then filtered and ducted into the data centre by means of an axial fan. Temperatures Achievable The hotter the outside temperature and the lower the humidity, the greater will be the cooling effect. On the hottest day in the UK up to 15 C of cooling can be achieved through this process. The air off temperature of a FreeCool in the UK is always below 23 C, thus providing excellent cooling for data centre and server room requirements. Why are Running Costs Less than Air Conditioning? Why do we need to run an air conditioning system when the external ambient temperature is suitable to cool computer equipment?. By simply bringing in external ambient air and extracting hot exhaust air this will keep a server room computer equipment cool most of the year. The economics of using evaporative cooling are surprising to most people. An 85% reduction in energy used compared to a conventional air conditioning unit seems too good to be true. This is achieved because in the UK it is cold most of the time. By using a control system to minimise energy usage of fans coupled with evaporative cooling when outside air temperatures exceed 21ºC, relatively low flow rates of air are required. The only significant energy use when FreeCool is deployed is in the fan for the air movement. Typically a 1KW evaporative cooling system can manage a 20KW load in the UK. This cooling coefficient can not be achieved with any current cooling technology. 7

FreeCool Cooling Energy Performance Like traditional Air Conditioning systems FreeCool technology will deliver constant equipment inlet temperatures at the agreed set point. The energy performance of FreeCool technology is dependent upon the temperature of the air and its relative humidity. Higher temperatures give greater cooling. Low relative humidity also gives greater cooling. There are two operating modes of the FreeCool system Ventilation Mode Cooling Mode Fan Assisted Airflow Only Evaporative Cooling plus Fan Assisted Airflow When the ambient air temperature is under 21 C there is no requirement to deploy the evaporative cooling process. During these periods which in the UK are in excess of 80% of running time the energy consumption equates to the sum of the low energy axial fans. Only when the ambient air temperature exceeds 21 C is there any need to engage the evaporative cooling circuit. In the UK during a typical hot period the ambient temperature approaches 30 C. This coincides with a Relative Humidity of under 50%. As the air passes over the pads it will typically cool down to about 22 C. There is less evaporative cooling in the night as the temperatures reduce and the humidity rises. Supply Air Temperature Achieved By FreeCool Systems Amb. Relative Humidity Temp 20% 30% 40% 50% 60% 70% 80% 20 C 12.0 13.0 14.5 15.5 16.5 17.5 18.5 25 C 16.0 17.0 18.5 20.0 21.0 22.0 23.0 30 C 19.5 21.0 22.5 24.0 25.0 26.5 28.0 35 C 23.0 25.0 26.5 28.5 30.0 31.5 32.5 8

In cool conditions FreeCool operates in ventilation mode and in hot conditions in cooling mode. The FreeCool control system will automatically balance the fan speeds to ensure constant computer equipment inlet temperatures relative to the external ambient. FreeCool Impact on Data Centre Efficiency. Traditional cooling technology is a major contributor to data centre infrastructure power overhead. The chart below shows typical examples, very often even with energy efficient technology PUE figures of only 2.0 (DCiE 50%) can be achieved. Typical PUE / DCiE Figures The deployment of FreeCool technology makes it possible for data centre efficiency figures to achieve PUE ratings >1.25 (DCiE 80%) when combined with additional energy saving technology e.g. passive aisle containment and airflow management technology. Typical Temperature Graph for UK Installed System 9

Table 1 Comparison of Energy Running Costs for typical Data Centre s with different efficiency ratings (10p per KW/hr) Critical DCiE DCiE DCiE DCiE DCiE Load 25% 50% 66% 80% 100% kw PUE 4.0 PUE 2.0 PUE 1.5 PUE 1.25 PUE 1.0 10 35,040 17,520 13,140 10,950 8,760 20 70,080 35,040 26,280 21,900 17,520 25 87,600 43,800 32,850 27,375 21,900 50 175,200 87,600 65,700 54,750 43,800 100 350,400 175,200 131,400 109,500 87,600 150 525,600 262,800 197,100 164,250 131,400 200 700,800 350,400 262,800 219,000 175,200 300 1,051,200 525,600 394,200 328,500 262,800 500 1,752,000 876,000 657,000 547,500 438,000 750 2,628,000 1,314,000 985,500 821,250 657,000 1000 3,504,000 1,752,000 1,314,000 1,095,000 876,000 Table 2 Comparison of CO 2 with different efficiency ratings Rate per KwH 0.1 Critical DCiE 25% DCiE 50% DCiE 66% DCiE 80% DCiE 100% Load PUE 4.0 PUE 2.0 PUE 1.5 PUE 1.25 PUE 1.0 kw CO 2 Tonnes CO 2 Tonnes CO 2 Tonnes CO 2 Tonnes CO 2 Tonnes 10 186 93 70 58 46 20 371 186 139 116 93 25 464 232 174 145 116 50 929 464 348 290 232 100 1,857 929 696 580 464 150 2,786 1,393 1,045 871 696 200 3,714 1,857 1,393 1,161 929 300 5,571 2,786 2,089 1,741 1,393 500 9,286 4,643 3,482 2,902 2,321 750 13,928 6,964 5,223 4,353 3,482 1000 18,571 9,286 6,964 5,804 4,643 Kw to CO 2 Kw Conversion 0.00053 10

Design and Installation Services FreeCool solutions should be installed as part of an integrated approach to data centre cooling and airflow management. When combined with energy efficient room layouts, aisle containment and airflow management techniques Workspace Technology designers can achieved industry leading room energy efficiency figures. (PUE <1.25) Workspace Technology provides a complete turnkey installation service including all building and duct works. Where existing AC systems are in place we will provide reconfiguration services to maximize data centre energy reduction. Airflow Volume Equivalent NetSensible Cooling Maximum Input Power 3m 3 per second 30Kw without aisle containment <40Kw with aisle containment systems 2Kw Cooling Coefficiency Minimum Cooling Coefficiency 15. Performance Maximum CoolinG Coefficiency <30 further improvements when combined with aisle containment systems. Operating Weight Dimensions 120Kg Height 1700mm, Width 1100mm, Depth 1100mm FreeCool System Specifications 11

About Workspace Technology The value that Workspace Technology can deliver to the customer experience is our complete understanding of the infrastructure solutions market, its products and services. By engaging with you and taking the time to understand your business and performance related issues, Workspace Technology is able to effectively address the demands of your business. Workspace Technology welcomes this opportunity to connect with you as a valued customer. We would like to share our vision and expertise through a partnership approach. Our ability to deliver integrated, scalable, energy efficient solutions has made us the preferred choice for many public sector and commercial businesses today. Operating throughout the UK, Workspace Technology offers clients an enthusiastic and refreshing approach, combined with teamwork that takes performance and service to new levels of excellence. Further details of Workspace Technology s products and services can be found at www.workspace-technology.com. Approved Endorser EU Code of Conduct on Data Centre Efficiency APC Elite Partner Data Centre Certified Workspace Technology s Commitment to help clients reduce their carbon footprint through the deployment of energy efficient technology and design. Creating an effective workspace environment Technology House, 5 Emmanuel Court, Reddicroft, Sutton Coldfield, West Midlands B72 1TJ. Tel : 0121 354 4894 Fax: 0121 354 6447 email : sales@workspace-technology.com www.workspace-technology.com