Local Firmware Download

Similar documents
Converting and Downloading Static Web Pages

Webconvert is a Windows program created by ipocket232 Inc. to convert HTML Webpages and associated files into a.hex file for download.

NL6000 Wireless Modem NL6000 User Manual Rev 1.1

Configurations for the Layer 3 Switch Router

1 Connecting to RoviSys OPC90 (Turbo) Using OPC90 with DBDOC - Bailey WinCAD or Composer. Page 1

Updating Reader Firmware

Updating E2 Controller Firmware Using UltraSite32

Figure 1: ZigBee Evaluation Kit (ZEK) Contents. Figure 2: ZigBee Adapter Zb-121 and Module Zb-21

installation manual SALES AND ADMINISTRATION (toll free)

Orbit Scanner Reprogramming and Testing. Install AutoSet2

Configuring the Switch with the CLI Setup Program

User Manual. Thermo Scientific Orion

ipocket232 User Guide

Accessing Web Version of Life Illustrator

Firmware Reprogramming Guide

DIL/NetPC DNP/5280 Board Revision 1.0 Installing a PPP Connection User Manual

technical bulletin Updating E2 Controller Firmware Using Ultrasite32

Setting Up a Remote Connection

Monitor and Manage your Power System with Ease.

Wireless Troubleshooting Guide

ZFSM-201-KIT-1 Wireless UART Application User Guide

WIRELESS RF MODEM SETUP MANUAL FOR CARDMASTER

How to upgrade the firmware

Administration of Cisco WLC

Troubleshooting. Diagnosing Problems CHAPTER

X5105 Firmware Update. Instruction

StreetWise Partner. Version 3.0. Naztec Operations Manual. April For. Published by:

Reno A & E, 4655 Aircenter Circle, Reno, NV (775) Release Date: February 5, 2008 All Reno A&E monitors. All versions of RaeComM.

BCOM-USB Device. User Manual.

Updating the Firmware in the BAM-1020 Particulate Monitor

Configuring the Switch with the CLI-Based Setup Program

Firmware zippack name : R exe Firmware File Name : Dell1815dn_V _AutoUpgrade.exe

Chapter 3. MUX100 Operation. 3.1 Controls and Indicators. 3.2 Powering On, Powering Off, and Initializing the MUX100

Nova series update F/W & Boot code from Boot Utility

(The model number in all attached pictures is only an example) 1. Introduction

Technical Information

Configuring the Switch with the CLI-Based Setup Program

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

BitPipe Cellular Dev- Kit

FTM-400DR/DE. Main Firmware Update Instruction Manual YAESU MUSEN CO., LTD.

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

Product Specification for CANbus to DeviceNet Transducer Gateway

Perle Dial-Out User s Guide

EEPROM Emulation with the ez80f91 MCU. Discussion

Service Bulletin Rev Firmware Upgrade for ACRC100 Series

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

How to upgrade firmware in DSL-xxx series router

Configuring the Switch

Intellislot SNMP / Web Card

SCI Testers and Remote Communication: Using HyperTerminal

Configuring the SMA 500v Virtual Appliance

Table of Contents. Cisco Xmodem Console Download Procedure Using ROMmon

EPSON TM-P60 WIRELESS PRINTER. Installation and Setup Guide

ADC Data Capture using Capture Demo and CCS Memory Browser IWR14xx/AWR14xx example. Document Version V

Chapter 9: Updating Firmware for the Passport 360

Metasys System Direct Connection and Dial-Up Connection Application Note

SCOPIA 100 Gateway Quick Start Version 5.6

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Step 1: Check the current firmware version of the device. Page 1 of 5

Initial Configuration for the Switch

The following simple procedures should be performed prior to testing the 289H M relay card:

GETTING STARTED GUIDE

OpenComms Web Card. English

Ether232Duo User Guide

Application Note Demonstrating the Serial Port Profile (SPP) Between BlueConnect and BTW 2002/5/29

Flash Loader Utility for the Z8 Encore! XP MCU

Lab Establishing a Console Connection to a Router or Switch Instructor Version

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes

Xmodem Console Download Procedure Using ROMmon

RN-111B-EVAL IGRN111B-EVAL 3/10/2009. WiFly evaluation Kit. Features. Description. Getting Started

Before you start the lab exercises see the lab administrator or EEE3080F tutor to get assigned to your routers.

Using the Lantronix WiBox with the CR800 or CR1000

MVI71-BDW. PLC Platform BARDAC Drive Web Interface. User Manual

Effective Immediately: (For internal and external distribution) Vanguard 3000 Firmware Upgrade Instructions

SCOPIA 100 MCU Quick Start

MVI71-GSC. PLC Platform Generic Serial Communication Module. User Manual

Boot Loader for the Z51F6412 MCU

APP-IIb PIC Development Kit by AWC

USB-Link 2 Technical Guide

Installing the Bootloader

Field Procedure For Installation Of A WEB/SNMP Card For enotify

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

MicroTech II ServiceTools for Applied Air Handling Unit Controllers

Please note that you may lose your previous settings when you upgrade your software. We advise that you write them down before starting the update.

MVI46-MBP. SLC Platform Modbus Plus Communication Module. User Manual

E ther S erie s. D N P-3 G ate w a y. User s Guide. Firmware Version 3.x

Cisco IOS Software Basic Skills

3980xpi/3980/3900 V8.2 User Notes

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

ALERT CONFIGURATION GUIDE SIA DRIVER

USB - SERIAL CONVERTER

BitPipe Cellular Dev-Kit

BASCOM51. Quick Start Guide

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

CMUCAM V1.12 interface Specific for RS232 By: Alexis Mesa

ControlLogix Redundancy Update and Module Replacement Guidelines

Transcription:

Local Firmware Download Help Guide Performing a local Firmware Download allows you to download the latest software version to the ipocket232 Inc. s unit using terminal emulation software, such as HyperTerminal or Procomm Plus. First, check the software version number and date in the System Settings sub-menu. For information on the latest software version, contact us at sales@ipocket232.com. Check the Software Version and Date NOTE: These instructions apply to HyperTerminal and Procomm Plus, but the settings and general procedures are the same for most programs. Get the Latest Software 1 Contact sales@ ipocket232.com to obtain the latest software for your device. You will be sent a.zip file. 2 Unzip the file. The.HEX file is the download file. Performing a Firmware Download 1 Connect the unit to the COM port of your PC or terminal with a null modem cable, just as you would for local configuration. www.ipocket232.com 1

2 Start the terminal program and press the CONFIGURE button on the back of the unit with a ballpoint pen or similar item. The Configuration screen appears. 3 Choose System Settings from the Device Settings menu. 4 Choose Firmware Download from the System Settings menu. The download confirmation message appears, as shown below. 5 Type n to stop the download and return to Configuration mode, or type y to continue. Instructions to reconfigure the terminal program appear, as shown below. 6 Change the communications settings to speed up the download. For HyperTerminal: 1. From the File menu, choose Properties. 2. In the Properties dialog box, click the Configure button. 3. Change the bps to 38400, the Flow Control to Hardware, and other settings as required. 4. Click OK. 5. From the Call menu, select Disconnect, then select Call. (This resets the terminal with the new settings.) For Procomm Plus: 1. From the Options menu, choose System Options>Modem Connections... 2. Click the Modem/Connections Properties button. 3. Change the baud rate to 38400, check the Use hardware flow control button, and change other settings as required. www.ipocket232.com 2

4. Click OK to close the Modem/Connections dialog box. 5. Click OK to close the Setup dialog box. 6 Press Enter. The Firmware Download Utility warning screen appears, as shown below. 7 Choose an option from the following: Type x for a trial download. This allows you to attempt a download without actually burning in the new code over the old. If you do the trial procedure without an error, you know you are doing it correctly. Type y for a full download. This option permanently deletes the existing code by burning the new code over it. Type n to stop the download process. The unit will reset and exit configuration mode. 8 You are ready to send the new firmware to the ipocket232 device. www.ipocket232.com 3

For HyperTerminal: 1. From the Transfer menu, choose Send Text File. 2. In the Files of type drop down box, select All files (*.*). 3. Browse to the.hex file you unzipped earlier, and click Open. For Procomm Plus Terminal: 1. From the Data menu, choose Send File... 2. Browse to the.hex file you unzipped earlier and click Open. The download begins immediately and dots appear as bytes of code are written into the memory. Once the download is complete you will get the Download Successful message, as shown below. 3 Reconfigure the baud rate to 9600 in the terminal software and press the CONFIG- URE button on the ipocket232 Inc. unit to return to configuration mode. NOTE: The ipocket232 Inc. unit should retain all your previous settings. Ensure your settings are correct before resuming operations. Error Messages DOWNLOAD ERRORS : If the terminal settings are incorrect, or there is a problem with the file, you may get an error message. For example, if hardware handshaking is not chosen as the method of flow control, the download will fail, as shown below. If you are performing a full download, you are prompted to begin the download again. Contact ipocket232 Inc. for a new download file if you encounter www.ipocket232.com 4

errors again. ERROR: no crc-check record was present! : Cyclic Redundancy Check (CRC) is an additional method of error detection that compares a specific value before and after transfer. If the CRC record is missing, then the CRC cannot be performed and should begin again or contact ipocket232 Inc. for a new download file. www.ipocket232.com 5