Equipment Specification

Similar documents
PRODUCT DATA. Advanced 128

Solid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

SCENARIA 64-Slice CT Putting Advanced CT Within Reach.

SCENARIA Hitachi Innovation at Work for You.

Fits you like no other

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Optimisation of Toshiba Aquilion ONE Volume Imaging

RADIOLOGY AND DIAGNOSTIC IMAGING

Whole Body X-ray CT System Supria. DICOM Conformance Statement

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR

Medical Image Processing: Image Reconstruction and 3D Renderings

Fits you like no other

Whole Body Submillimeter Scan

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Whole Body X-ray CT System Supria. DICOM Conformance Statement

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Fujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.

Symbia T Series System Specifications Answers for life.

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

MEDICAL IMAGING 2nd Part Computed Tomography

Lower Dose with Confidence

Computer-Tomography II: Image reconstruction and applications

DICOM Conformance Statement

DX-D 800 DX-D 800 DYNAMIC, 3-IN-1 DIRECT RADIOGRAPHY SYSTEM OFFERING REAL TIME IMAGES FOR FLUOROSCOPY, GENERAL RADIOGRAPHY AND DIRECT EXPOSURES.

Corso di laurea in Fisica A.A Fisica Medica 4 TC

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Hitachi Medical Systems America, Inc. Hitachi Medical Corporation

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

O-ARM IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Ch. 4 Physical Principles of CT

DICOM Conformance Statement

International Journal of Innovative Research in Advanced Engineering (IJIRAE) ISSN:

icatvision Quick Reference

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Routine excellence. Philips Ingenuity Core specifications

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

CT: Physics Principles & Equipment Design

Best inspection system for after reworking of the BGA, and other electronic parts.

Philips SPECT/CT Systems

Athena Radiology Medical Workstation

Introduction to Biomedical Imaging

AIDR 3D Iterative Reconstruction:

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

INTERNATIONAL STANDARD

A closer look at CT scanning

The protocols used to scan the musculoskeletal system are tailored to each patient and

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Lucy Phantom MR Grid Evaluation

Micro-CT Methodology Hasan Alsaid, PhD

Baby Explorer 2002 Software Description

CTA HEAD Perfusion AqONE without and with IV Contrast

VJ Technologies Inspection Services Division. By Bob Maziuk, February 2015

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

MEDICAL IMAGING 2nd Part Computed Tomography

AAPM Standard of Practice: CT Protocol Review Physicist

VXRE Reconstruction Software Manual

S. Guru Prasad, Ph.D., DABR

abc Report Wide bore CT scanner comparison report version 12 February 2005 best choice best practice nww.medical-devices.nhs.

Digital Image Processing

DX-D 100 with wireless detector

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

CT vs. VolumeScope: image quality and dose comparison

GPU implementation for rapid iterative image reconstruction algorithm

Lorad FFDM QC Procedures for Medical Physicist. Tao Wu, Ph.D. Hologic, Inc.

product data Raybow dr mobile digital radiographic system with wireless detector product data

ImPACT. CT dosimetry and a data base for CTDI values. EFOMP Workshop at ECR Imaging Performance Assessment of CT Scanners

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

BLUEPRINT TM 3D Planning Software - v1.4 scan protocol

DICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997

DX-D WITH DX-D 40/45 DETECTOR FAMILY MOBILE DR SOLUTION

Image Post-Processing, Workflow, & Interpretation

Some reference material

xorantech.com Suite of DR Products

Fundamentals of CT imaging

Image Acquisition Systems

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

Fischerscope X Ray CIRCULARS 07/01

Comparison of the Imaging Performance of CT Scanners, Issue 11

First CT Scanner. How it Works. Contemporary CT. Before and After CT. Computer Tomography: How It Works. Medical Imaging and Pattern Recognition

DX-D 100 WITH WIRELESS DETECTOR

Computed Tomography Imaging: CT Protocol Management. Caveat 8/3/2017

The 3D Accuitomo 80 offers a minute voxel. size of just 80 μm (micrometer). This super-fine. voxel combined with the unit s 13 bit grayscale

DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-037A and XIDF-038A or SRS-1000A

Brilliance CT Big Bore.

CT Dose Profiler. Probe for evaluation of CT systems. CT Dose Profiler User's Manual - English - Version 6.4A. RTI article number:

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

LAMBDA DATA SHEET. ANALOGIC mammography unit. ANALOGIC mammography unit. Rev. n.05 of 15/01/13

A study on image quality provided by a kilovoltage cone-beam computed tomography

DICOM Enhanced XA/XRF Object New Dimensions for X-Ray Projection Imaging. (DICOM Supplement 83)

Transcription:

MULTISLICE CT SCANNER ( 16 Slices ) Merk : Hitachi Japan Model : SUPRIA 5 MHU Price : Rp 6.512.360.215,27 No Equipment Specification 1 2 3 Scanner Gantry Object for scanning : Whole body including head Scanning time : rotation 0.75/ 1.0/ 1.5/ 2.0 sec Scanning region : 360 continuous scan Max. Number of slice : 16 slice/scan Gantry Opening/Bore diameter : 750 mm Effective FOV : 500 mm FOV Variations : 20-500 ( 1mm step) Gantry Tilt angle : Forward tilt 30, backward tilt 30 Helical and/or sequential scanning : Yes, available Setting scan position : Light Localizer for: - Median sagital plane - Axial plane x 2 - Coronal plane x 2 Remote control : Yes Scan start/stop button : Standard (with delay time display) Measuring patient dose radiation : Yes Gantry width (front to rear) : 920 mm Patient Table Material of table top : Carbon fiber Table height (vertical speed) : 450-1,000 mm (CT-WT-20) Tabletop width : 400 mm Longitudinal Stroke 0-1570 mm (± 3 mm) Longitudinal Speed 150 mm ± 3mm/s Max. scanable range : 1,200 mm (1,500 with extended tabletop) Maximum Load : 180 kg Free float Standard (Button) X-Ray Generator/Detector X-Ray tube : 5 MHU Max. Output power : 48 kw (400 ma@120 kv) HV Generator Max output 51kW Max. cooling/heat dissipation : 748 KHU/min Tube voltage : 80/100/120/140 kv Tube current : 10-400 ma (5 step)

4 ma Selection : 10-400 ma Meaurement types 2 types, 0.625 x16 and 1.25 x 16 Tube Focus Size : 0.7 x 0.8 mm and 1.2 x 1.4 mm CTDI (Surface and body) : CTDI 100 Body: 9.4mGy Spatial resolution : 17.1 lp/cm Detector type : Solid state detector Detector configuration : 880 ch x 32 rows (0.625 mm x 32 rows) Focus to isocenter distance : 606 mm Focus to detector distance : 1072 mm No. Elements per row : 880 ch Number of rows : 32 rows Number of elements : 28,160 No. of elements (usable) : 28.160 (input) Fastest X-Ray tube Rot speed : 0.75 sec Max. No. of slice per rotation : 16 slice Physical detector size : 20 mm Physical detector use for scan : 20 mm Scanning Function Measurement slice thickness (Scanogram) : 0.625 x 8 Collimation : 0.625 x 32 (20 mm used for scan) Collimation at normal scan : 0.625 mm x 2 0.625 mm x 8 0.625 mm x 16 1.25 mm x 12 1.25 mm x 16 Continuous scan time : 10-100 sec (150 ma to 400 ma) Slice thickness : 0.625 / 1.25 / 2.5 / 3.75 / 5 / 7.5 / 10 mm * Scanogram : - Max. scanable range : 1,500 mm (with extended tabletop) - Measurement slice thickness : 0.625 x 8 * Normal Scan: - Scan time : 0.75 / 1.0 / 1.5 / 2.0 sec * Dynamic Scan: - Scan time : 0.75 / 1.0 / 1.5 / 2.0 sec * Volume scan: - Scan time : 0.75 / 1.0 / 1.5 sec - View rate : 1,200 view/sec - Reconstruction method : CORE (3D image reconstruction algorithm) Volume Pitch : 0.563-1.563

Image reconstruction time : 10 images/sec Scan time : (chest-lung field + : 7.2 sec (0.625 mm x 32/P : 1.5625) mediastinal space: 300 mm) Total examination time (scan time : Aprox. 50 sec (2.5mm/120 images x 2) + image reconstruction time Scan time : (chest-abdomen : 600 : 14.4 sec (0.625 mm x 32/P : 1.5625) Total (scan + image recon time) : Aprox. 25 sec (5.0 mm / 120 images) Confirmatio of images after scan : direct cine 5 Image Display/Proccessing Display monitor : 24 inch LCD Monitor Operating System (OS) : Windows embedded Standard 7 (64 bit) Reconstruction matrix : 512 x 512 Reconstruction time : max. 10 images/sec (ips) Reconstruction algorithm : CORE method (3D) Beam pitch : 0.563 to 1.563 Auto MPR : Standard Display matrix : 1,920 x 1,200 Spatial resolution : 17.1 Ip/cm Density resolution : 2.5 mm@ 0.25% Magnetic disck unit: - Storage image : 200,000 images or more - Storage Raw Data : 6,000 scans or more Archival storage : DVD Drive (CD-R, DVD-R) CD Approx. 1,100 images (650 MB) DVD Approx. 8,000 images (4.7 GB) Display grey scale : 256 levels Window level : Standard : -2,000 - +4,000 Extended : -32,768 - +32,767 Window width : Standard: 1-6,000 Extended: 1-32,767 Data display : patient name, Birthday, Sex, ID No, Slice thickness, tube voltage, tube current, slice position, state of contrast and others Window Process : - Window level/width adjustment - Black-white contrast revesal - Linear/Non linear window - Double window - Level detection Image Display process : - Multi-frame display - Magnification (real time, etc) - Image rotation

6 7 - Left-right inversion - Correction - Comment display - Cine display - Substraction/Addition - Edge enhancement/smoothing - Multi slice image addition Image analysis process : - Distance and angle measurement - Profile of CT value - Setting ROI * Shape: Oval, Free * Process: Area, Mean value of CT# * Display: up to 4 ROIs can be displayed * Control: Size, Position, Rotation - Histogram - Display of CT value - Scale Display - Volume calculation 3 D Image process : - MPR (SAG, COR, OBL, CURVE) - MIP, MINIP, RaySum display - Surface rendering - Volume rendering - MARP - Movie display - Perspective method Operator's/Main Console CPU : 64 bit Intel high end processor Operating System : Windows 7 based embedded Memory : 8 GB Hard disk : more than 250 GB Number of display : 1 Display with large LCD monitor 24 inch Control Methode : Keyboard, mouse and intercom Standard function : DICOM 3.0 DICOM Print DICOM Dose SR Predict Scan Intelly IP (Advanced) Intelly EC (SD-Mode) CEV-CPR Auto MPR Standard Acessories

Head rest (without arm rest) Head/chin band Patient belt Patient malt Patient fixing parts Instruction manual Note : Harga diatas tidak termasuk 1 Ongkos kirim 2 Dicom Printer 3 Injector 4 Renovasi 5 Ijin BAPETEN 6 Grounding 7 Panel 8 Cabling 9 Pelapis Dinding (PB) 10 Kaca PB 11 Fondasi/Penguatan 12 AC 13 Dehumidifier 14 Pencahayaan