Five-Axis Fiber Aligner Model 9091 and Accessories

Similar documents
Translation Stages Triple-Divide Series

The Berek Polarization Compensator Model 5540

MicroLab Component Holders

Picomotor Drivers and Motorized Products

Models 1417 and 1437 User s Manual. High-Speed Photodetector Modules

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A MICHELSON INTERFEROMETER. TECHSPEC Optical Cage System

Radiant Dyes Laser Accessories GmbH

ASI Photoport TIRF Injector Instruction Manual

Laser Diode Collimators Type 48TE, 48-0, and 44TE, universal modular system for self-assembly

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20

GH-50. Gimbal Head. You re on steady ground

DBR Laser Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

LS-785 High Throughput Lens Spectrograph User Manual

Instructions. Remote Controlled Rotator RCR

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Fantasea Blue Ray Tray (Cat. No. 2040, 2045, 2050) Instruction Manual

Further Information can be found at

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System

Index Scope of Delivery General Information Mounting of Digital Backs Mounting of Lenses Mounting on a Reproduction Stand

OC - Optical Components

20W Tungsten-Halogen Light Source. Operation Manual

VDL-004. Miniature Manual Variable Optical Delay Line. User Guide

NBS-2X NIMBUS STABILIZER QUICK-START GUIDE

Continuous Wave 532 nm Diode-Pumped Solid State Laser CDPS532M

DSLR Camera Cage Shoulder Rig Kit (FC-03)

Modular Series Mounting Solutions

D. Instruction Manual and Experiment Guide for the PASCO scientific Model OS-8523 SLIT ACCESSORY FOR THE BASIC OPTICS SYSTEM

Measuring object. Fig. 1: Optical scheme of focus-touching (concentricity measurement with measuring ball)

Revision 1, October 9, 2008 Copyright Luminos Industries Ltd. Parts: P3R, P2YP, P2RY, P2RP

9ft Jib Arm with Tripod (P-9-TS)

EPILOG LASER Table Mountain Parkway Golden, Colorado Phone FAX

INSPECTION TOOLS EYL10X. 10X Eye Loupe

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

Fiber Management Tray (FMT) User Manual

DE8800 Series. Fiber Optic Inspection Scope. User s Guide

GH-30. Gimbal Head. You re on steady ground

GCX Mounting Assembly Installation Guide. Pedestal Mount for Philips IntelliVue MP5/20/30/40/50/60/70, MX400/450/500/550/600/700/800

NAV-1 Lens Support. NAV-2 Lens Support BEFORE YOU BEGIN

4. Recommended alignment procedure:

In-Sight 7000 Series Vision System. Optional Configurations

Straightness measurement

MicroLab Posts, Bases, and Rails

PHOENIX LENS USER GUIDE Version 1.2

Projectors 6 and 7 Ruggedized Lens Components Installation Manual

INGRID. Lens Mount Assembly and Alignment Procedure. Author: Paul Jolley

Cary Fiber Optic Probes

Agilent 10706B High Stability Plane Mirror Interferometer

EVOLVE1-M MONITOR ARM

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Locking Reconstruction and Mini Plate System. Contourable in three dimensions.

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

TEC APO 200 OWNER S MANUAL

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

VIDEO Camera Cage WITH MATTE BOX FC-65-N

Macro View All in One Scope Description. 2. Features. 3. Package Contents

SlicePlatform Fixed Platform System

DSLR Camera Cage Shoulder Rig Kit

IS50-CM Corner Mount. For Use with IS50/IS51 Series Camclosure 2 Dome Cameras C2261M (8/11)

CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object

Planar Model A480-PL Professional Grade Home Cinema Conversion Lens System

DigiPot Software Configuration Menu

Contents. MicroDome Recess Mount Installation. Arecont Vision MicroDome Installation Manual

MODULE & HANDPIECE HOLDER POWER SWITCH LED INDICATORS USB PORT (SERVICE) REMOTE INTERLOCK

Rackmount Keyboard Installation Instructions. Revision A A-0000

LaserLyte-Flex Red & Green Alignment System

Index. 1. Scope of Delivery General The Controls of the Sinar p3-df View Camera Assembly of the camera 6

Positioning system of a metrological AFM: design considerations

3M Cross-Connect Cabinet Riser Installation Guide

M40 Microscope User s Manual

Orion Deluxe Off-Axis Guider

MICHELSON S INTERFEROMETER

DSLR SHOULDER RIG I N S T R U C T I O N M A N U A L. For Demonstration only

±15 V Current-Limited Power Supply

DSLR Camera Cage Shoulder Rig Kit

RAMM Microscope Configuration Guide

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

DSLR Video Shoulder Mount Rig (FC-55)

Precise Fiber Couple Laser Light Source

HeadMouse Extreme. Bracket Installation Instructions for DynaVox Maestro. Additional Resources. Bracket Installation Instructions for Maestro

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

25 The vibration spiral

0.75x Vertical Compression

Holz-Her Sliding Table Saw Kit Installation Instructions: For 1243 Rip Kits

Belly Cruzer DSLR Steady Camera Rig FC-BC-DSR-P

SWL-7500 Series Single Wavelength External Cavity Diode Laser

C10-UM Universal Indoor Camera Mount

Profile Projectors. Microscopes

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Magnetic probe holders are fully adjustable for more DUT heights and probe styles

USER S MANUAL

Formulate Designer Series 20 Backwall - Kit 11

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

QUICK START GUIDE. 1. How to register your Camera to Hubble account A. Setting Up the Camera - can be connected via WiFi or LAN

Advanced Camcorder Support System. Instruction Manual

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Quad Monitor Desk Stand - 13" to 24" Installation Instructions

Piezoelectric Tip-tilt Mirror

Transcription:

USER S GUIDE Five-Axis Fiber Aligner Model 9091 and Accessories Includes Model 9131-FS-FC and Model 9131-FS-ST Fiber-Aligner Kits U.S. Patents: #5,282,393 & #5,400,674 5215 Hellyer Ave. San Jose, CA 95138-1001 USA phone: (408) 284 6808 fax: (408) 284 4824 e-mail: contact@newfocus.com www.newfocus.com

Warranty New Focus, Inc. guarantees its products to be free of defects for one year from the date of shipment. This is in lieu of all other guarantees, expressed or implied, and does not cover incidental or consequential loss. Products described in this document may be covered by one or more of the following U.S. patents: #5,282,393 and #5,400,674. Information in this document is subject to change without notice. Copyright 2002, 2001 1998, New Focus, Inc. All rights reserved. The and logos, and NEW FOCUS, Inc. are registered trademarks of NEW FOCUS, Inc. Document Number 900983 Rev. D

Contents Introduction 5 Overview............................. 5 Principles of Operation................ 5 Accessories........................... 7 Operation 9 Setup................................. 9 Alignment............................ 10 Specifications 12 Performance.......................... 12 Physical Characteristics................ 13 Customer Service 14 Technical Support..................... 14 Service................................ 14 Appendix: Mode Matching 15 Maximizing Coupling Efficiency....... 15 Five-Axis Fiber Aligner Contents 3

4 Contents NEW FOCUS, Inc.

Introduction Overview The Model 9091 five-axis fiber-aligner system has the submicron resolution and stability required for aligning single-mode optical fibers. The aligner has three axes of translation and two axes of rotation. Proper kinematic design, precision 80-pitch adjustment screws, and sapphire seats produce lifelong X and Y resolutions of 0.01 µm with minimal hysteresis. Typical five-axis fiber aligners are built by stacking five single-axis stages. Each of these stages contributes its own slop and error to your optical system. In contrast, our aligner consists of a single stage positioned by five actuators and mounted in a solid frame. This design provides five unique degrees of freedom and exactly one constraint, making it more stable than traditional fiber aligners. The New Focus fiber aligner, in conjunction with its accessories, provides objective-to-fiber capabilities for ST- or FC-connectorized fibers. Principles of Operation The optical fiber is carried in the stage plate of the aligner (see Figure 1 on page 6). The stage plate is supported in the X Y plane by two perpendicular 80-pitch screws that intersect radially at the fiber end. Rotating the X- or Y-screws causes a translation of the fiber. Five-Axis Fiber Aligner Introduction 5

The stage plate is supported from behind by three 80- pitch adjustment screws (two Z-screws and the Z- knob), located at three corners of a square where the optical fiber is positioned in the fourth corner (Figure 2). You can achieve pure rotation about the fiber end by holding one of the Z-screws with an Allen wrench while turning the Z-knob. To minimize undesirable translation during this rotation, the fiber-end face must be positioned in the fibertip plane defined by the Z-axis screws. Pure Z-axis translation is achieved by adjusting the Z-knob, which rotates the two Z-screws equally. Figure 1: Front view of Model 9091 Positioner, shown with optional accessories Optional Model 9123 objective holder Y Coarse Y-screw Fine Y-screw Fine X-screw Coarse X-screw Z Optional Model 9092 coupler body X Stage plate Figure 2: Rear view of Model 9091 Positioner Z-knob Z-screws Coupler-body screws 6 Introduction NEW FOCUS, Inc.

Accessories Use the following accessories to attach fibers or objective lenses to the fiber aligner. Most of these accessories are shown either in Figure 1 on page 6 or Figure 4 on page 10. Model 9092 Coupler Body: Use the coupler body to hold optical elements, such as objective lenses and fibers, stationary. You may also need one of the holders listed below to fit the element into the coupler body. (For infrared applications, a gap between the coupler body and the positioner can accommodate IR cards.) This is included with all Model 9131 kits. Model 9123 Objective Holder: Attach a standard RMS-threaded microscope objective to this objective holder in order to mount it on the Model 9092 coupler body. This is included with all Model 9131 kits. Model 9126 ST Adapter: These adapters mount STconnectorized fibers to the stage plate of the fiber aligner. This is included with the Model 9131-FS-ST kit. Model 9127 FC Adapter: These adapters mount FCconnectorized fibers to the stage plate of the fiber aligner. This is included with the Model 9131-FS-FC kit. Model 5708 Asphere Adapter: These adapters hold our Model 572X aspheric lenses and fit directly in the Model 9092 coupler body. Model 5709 RMS Adapter: These adapters also work with our aspheric lenses. Attach this adapter to the Model 9123 to fit it into the coupler body. Five-Axis Fiber Aligner Introduction 7

8 Introduction NEW FOCUS, Inc.

Operation Setup 1. Attach the Coupler Body (optional): If you are using the Model 9092 coupler body, fasten it to the fiber positioner with the two provided 8-32 (M4) screws and a 9/64" (3-mm) Allen wrench. Figure 3: Attaching the coupler body Coupler-body screws Note: 2. Mount the Aligner to the Table: For maximum rigidity, mount the fiber aligner on a New Focus pedestal riser. The fiber end is approximately 1" (25.4 mm) above the aligner base. Mounting holes are placed on two orthogonal sides of the aligner for either left- or right-handed mounting. 3. Mount the Output Fiber: Mount the connectorized fiber to the appropriate adapter: Model 9126 for ST connectors or Model 9127 for FC/PC connectors. For bare fibers, we recommend using a bare-fiber terminator to give it an ST or FC connector. Five-Axis Fiber Aligner Operation 9

Figure 4: Mounting the output fiber Optional Model 9126 ST adapter Optional Model 9127 FC/PC adapter 4. Attach the Output Fiber to the Positioner: Insert the fiber assembly into the back of the positioner, firmly seating the assembly against the ledge in the rear of the stage plate. Tighten the fiber-adapter lock with a 1/16" (1.5-mm) Allen wrench. Figure 5: Attaching the output fiber to the positioner Insert fiber assembly into positioner. Fiber-adapter lock Alignment Note: For most adjustments to the aligner, you will need a 1/8" (3-mm) Allen wrench. Coupler Translation (Positioning the Focus) 1. Screw the objective lens into the Model 9123 Objective Holder. For New Focus aspheric lenses, you can mount the lens into the coupler body using the Model 5709 RMS adapter 10 Operation NEW FOCUS, Inc.

and the Model 9123 objective holder, or using the Model 5708 1" adapter. 2. Position the holder in the coupler body so that the objective-lens focus is in the fiber-tip plane. 3. Tighten the thumbscrew to lock the objective into place. X/Y Translation The coarse X- and Y-screws each translate the fiber over a 3-mm range with 1-µm resolution. With the fine X- and Y-screws, 8 µm of final tuning can be achieved with a resolution of 0.01 µm. Z Translation Turning the Z-knob translates the fiber along the Z-axis of the aligner. This adjustment produces a 1-µm resolution over a 3-mm range. Rotation about the Fiber End Pure tilt about the fiber end is achieved by holding one of the two Z-screws with an Allen wrench while turning the Z-knob, as shown in Figure 6. Figure 6: Rotation about the fiber end Five-Axis Fiber Aligner Operation 11

Specifications Performance Model # 9091 Degrees of Freedom X, Y, Z, θ x, θ y X, Y, Z Travel 3 mm X, Y Coarse Resolution/5º Turn 4.4 µm X, Y Fine Resolution/5º Turn 0.02 µm Z Resolution/5º Turn 4.4 µm θ x, θ y Range θ x, θ y Resolution/5º Turn 5 degrees 231 µrad 12 Specifications NEW FOCUS, Inc.

Physical Characteristics 3.40 (86.5) 1.25 (31.7) 1.00 (25.4) 0.22 (5.5).00 REAR VIEW 3.40 (86.5) 2x C'BORE FOR #8 (M4) SHCS 1.25 (31.7) 1.00 (25.4) 0.22 (5.5).00 2.48 (63.0) FIBER CHUCK LOCK 1.19 (30.2).60 (15.2).00 4x 8-32 (M4) THREAD 2x 2.00 (50.4) 2x 1.00 (25.4).00 0.25 (6.3) 0.00 0.25 (6.3) 0.50 (12.5) 1.00 (25.0) FRONT VIEW 6x 4-40 (M2.5) THREAD 1.00 (50.0) 0.50 (12.5) 0.25 (6.3) 0.00 0.25 (6.3) Five-Axis Fiber Aligner Specifications 13

Customer Service Technical Support Information and advice about the operation of any New Focus product is available from our applications engineers. For quickest response, ask for Technical Support and know the model and serial numbers for your product. Hours: 8:00 5:00 PST, Monday through Friday (excluding holidays). Toll Free: 1-866-NUFOCUS (1-866-683-6287) (from the USA & Canada only) Phone: (408) 284-6808 Support is also available by fax and email: Fax: (408) 980-8883 Email: techsupport@newfocus.com We typically respond to faxes and email within one business day. Service In the event that your fiber aligner becomes damaged, please contact New Focus for a return authorization number and instructions on shipping the unit back for evaluation and repair. 14 Customer Service NEW FOCUS, Inc.

Appendix: Mode Matching Maximizing Coupling Efficiency To maximize the coupling efficiency into a singlemode optical fiber, the incident optical field distribution at the fiber face should match the mode profile of the optical fiber. This can, in general, be modeled as a Gaussian with a 1/e width of ω m ; typically, the modal field diameter is slightly larger than the core diameter. Given a lens with focal length f and an incident Gaussian beam with diameter D, the lens produces a focused spot diameter, ω, where 4λf ω = --------- πd where λ is the wavelength of the incident light. (See Figure 7 on page 16.) Assuming that the incident laser beam has a waist of ω 1, the lens should be placed at a distance d 1 so that the focused waist diameter ω matches the modal field diameter ω m. The distances d 1 and d can be found from the following expressions: d 1 d = = f f ω ----- 1 f 2 2 ± f ω 0 ω ----- f 2 2 ± f ω 0 1 where f 0 = πω 1 ω ------------- λ Five-Axis Fiber Aligner Appendix: Mode Matching 15

Figure 7: A lens with focal length f focuses an incident optical beam of diameter D to a waist of diameter ω, as expressed by 4λf ω = -------- πd ω 1 d 1 D d ω 16 Appendix: Mode Matching NEW FOCUS, Inc.