Bulletin 855E 50 mm Control Tower Stack Lights

Similar documents
Bulletin 854K 60 Mm Control Tower Stack Lights

Control Tower Stack Lights

COMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21

SL7CB100 Stacklight Led Flashing, Yellow, 120V, 70MM

S 180 OPTICAL AND AUDIBLE MODULAR DEVICES. This is our idea that lead us to create and engineering this modular lamp. MODULAR CONFIGURATION

Light Module Type. Lens Color Description V AC/DC (no-lamp module ) Steady no lamp. 3 Green 24 24V AC/DC. Steady LED.

LED-Signal Tower modulcompact70

16 Mm. Bulletin 800B 16 mm Push Buttons. Features. Operator Assembly Sequence. Push Button & Pilot Light Operators. Build a Catalog Number

General-Purpose Photoelectric Sensor

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Push Buttons and Operator Interface Specifier s Guide Type XVA Indicating Banks and Beacons

Cat. No. 800B-EPA 800B-EPB 800B-EPC 800B-EPD. Cat. No. 800B-ALB4. Cat. No.

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Bulletin 700-HA Tube Base Relay

2-Position Cylinder Lock Operator Cat. No. 800T-H33A 800 T H31 A. Protection Rating Description T Metal, Type 4/13

signaling solutions from auer signal

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

800 T A 1 A. f (cont'd) d (cont'd) f (cont'd) Momentary Contact Push Button Devices, Non-Illuminated. Rockwell Automation Publication 800-TD009A-EN-P

25 m 5 m 1 m. Part Number Mounting bracket. E39-LU1 Mounting bracket for E39-R1 reflector

ALLEN BRADLEY RELAY Bulletin 700-HF

SL7 and SL4 signal towers. Product Range Catalog Clearly brighter, louder und faster

Not recommended for use in applications where there is high probability for exposure to liquid (e.g., cutting fluid) on the sensing surface area.

Bulletin 700-HL 2-Pole Terminal Block Relay

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Enhancing Business Performance

Photoelectric Sensor

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

RCMB20/RCMB Series

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

02/11/2015

TL70 Modular Tower Light

World Class Design for Light Industrial and Instrumentation Applications. 16 mm 800B

Signal Tower KombiSIGN 50

Contents. Part no.: MLC500T Safety light curtain transmitter

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Inductive Proximity Sensor

Inductive Cylinder Position Sensors

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

KombiSIGN 71 - Signal Tower

08/07/2015

Cat. No. (Spring Clamp. Input Voltage

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Schaedler Yesco Industrial Control Product Update

Push buttons and selectors

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Bulletin 800Z Zero-Force Touch Buttons

FL200 Monochromatic Architectural Spot and Floodlight

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

onlinecomponents.com

FL50 RGBW Inner Mixing Architectural Spot and Floodlight

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM35TF V AC

02/11/2015

Thermal-Magnetic Circuit Breaker 2216-S

XVUC21B base unit module 24V AC/DC - black

02/11/2015

industrial panel lamps

Versatile modular Signal Tower featuring easy assembly and wiring designed for every need. How to Order LU7-E-R

InView Marquee Message Display

Korry 1380 high-performance switch with oversized display for master caution and warning systems

EAO Your Expert Partner for Human Machine Interfaces. EAO Product Information. Series 56

CompactBlock Guard I/O EtherNet/IP Safety Modules

02/11/2015

Thread length (overall length) material

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Bulletin 871D Cylinder Position Inductive Style

Color Mark Photoelectric Sensor E3S-VS

Photoelectric Sensors E3F2

Catalog February Control and Signaling Indicating Banks XVP 50mm

Series 7000 Miniature Rectangular Style

Electronic timer CT-ERS.21

Model Number Structure

Allen-Bradley 700-K40E-DJ

Safety Light Curtains GuardShield Remote Teach

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Pile Driver Weld Immune Sensors

Installation Instructions for Rebel Chameleon TM 105XBRi Series LED Multi-Status Indicator in NEMA 4X Enclosures

Bulletin 871L & 872L Limit Switch Style

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

Description. Features. Ultrasonic Sensors 873P Analog or Discrete Output INTRODUCTION. 873P Analog Output18 mm. 873P Discrete Output30 mm

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Bulletin 854K 60 mm Control Tower Stack Lights

T imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC.

Transcription:

Bulletin 855E 50 mm Control Tower Stack Lights Light Modules Sound Modules Flashing Incandescent 855E 10 FN 4 Voltage Light Module Type Lens Color 00 0 250V AC/DC (no lamp module) (1) XN Steady no lamp (1) 3 Green 12 12V AC/DC DN Steady incandescent 4 Red 24 24V AC/DC FN Flashing incandescent 5 Amber 10 120V AC TL Steady socket-mount LED 6 Blue 20 240V AC GL Flashing socket-mount LED 7 Clear BL Strobe 8 Yellow (1) Can only be selected with module type XN, voltage code 00. Accepts socket mount incandescent lamp types only. Sound modules have continuous and pulsing tones. Maximum sound output is 103 db at 1 m (3.3 ft). A reduced volume setting is available by changing the position of the volume DIP switch, which produces a sound output of 88 db(a) at 1 (3.3 ft). Maximum sound output is 80 db(a) at 1 m (3.3 ft). Black Two-tone Sound Module 855E B 10 TA3 Housing Color Voltage Module Type B Black 12 12V AC/DC SA3 Single circuit/single tone piezo style steady/pulsing DIP switch selectable G Gray 24 24V AC/DC TA Two circuit/two-tone piezo style steady/pulsing DIP switch selectable 10 120V AC 20 240V AC 46 Rockwell Automation Publication 855-TD001D-EN-P - December 2016

Standard Stack Light Bases Surface-mount Base with Cap Vertical-mount Base with Cap Pole-mount Bases Quick-release Base 855E B VM C Housing Color Base Type Cap Option (1) B Black CB Surface mount with 1/2 in. NPT threading Blank No cap G Gray RB Surface mount with M20 metric threading C Cap included SB Surface mount with PG16 threading TM 25 mm tube mount VM Vertical mount PM10 10 cm aluminum pole-mount base PM25 25 cm aluminum pole-mount base PM40 40 cm aluminum pole-mount base PM60 60 cm aluminum pole-mount base PM80 80 cm aluminum pole-mount base MM10 10 cm quick-release base MM25 25 cm quick-release base MM40 40 cm quick-release base (1) Quick-release bases always include a cap. Rockwell Automation Publication 855-TD001D-EN-P - December 2016 47

Pre-configured Tower Lights, 1 5 Modules Level 5 Level 4 Level 3 Level 2 Level 1 Surface Mount Vertical Mount 10 cm Pole Mount 25 cm Pole Mount 855 EC B 10 Y 3 L 5 B 3 F 7 Y 6 d e d e d e d e d e (Level 1, d+e) (Level 2, d+e) (Level 3, d+e) (Level 4, d+e) (Level 5, d+e) Base Type Base & Cap Color Voltage EC Surface mount - 1/2 in. NPT threading B Black 12 12V AC/DC ES Surface mount - PG16 G Gray 24 24V AC/DC EV Vertical mount 10 120V AC EM 25 mm tube mount 20 240V AC EP 10 cm pole mount EE 25 cm pole mount d e Module Type Lens Color/Sound Code Description Code Description D Steady incandescent 1 Sound module (2) F Flashing incandescent 3 Green Y Steady LED 4 Red L Flashing LED 5 Amber B Strobe 6 Blue P Single-circuit piezo sound module 7 Clear Q Two-circuit piezo sound module (1) 8 Yellow (1) If the two-circuit sound module (option Q in Table d) is selected, the maximum number of light modules that are allowed is three. (2) Sound module option can only be selected with Module Type option P or Q in Table d. They must be located in the top position of the stack. 48 Rockwell Automation Publication 855-TD001D-EN-P - December 2016

Specifications (Bulletin 855E) Table 62 - Mechanical Standard Bases Surface Mount Base or 10 cm Aluminum Pole Base Vertical Base or 25 cm Aluminum Pole Base Recommended Wire Sizes Recommended Terminal Torque Table 63 - Environmental Based on the weight and style of mounting; tower lights are subject to damage from shock and vibration. Listed below are reference guidelines for maximum acceptable conditions. Shock [G] Vibration [G] 1 module stack 150 5 3 module stack 45 1.5 5 module stack 35 0.75 1 module stack 95 3.5 3 module stack 30 1.25 5 module stack 20 0.5 0.5 1.5 mm 2 (22 16 AWG) 0.87 N m (7 lb in) Attribute Light Modules with Cap Sound Modules Ingress Ratings Surface, Vertical, Tube Mount Bases Pole Mount Bases Flange-style Base with M12 Micro Connector (1) Operating Temperature Ranges Storage (1) UL Type 1 when used with Cat. No. 855T-AVM mounting bracket. Value -25 +50 C (-13 +122 F) -40 +85 C (-40 +185 F) Table 64 - Materials Part Bases, Caps, Lens Covers, Sound Module Housings, Lenses Lamp Socket Rubber Seals and Gaskets Pole (for aluminum pole assembly) Pole Base Footing (for aluminum pole base) Insulation Sleeve (for pole insulation) Mounting Screw Washers Material Polycarbonate Polycarbonate Nitrile rubber Aluminum Polycarbonate Polyolefin Polypropylene Table 65 - Light Output Steady Incandescent Flashing Incandescent Strobe Steady, Flashing Socket Mount LED Red Green Amber Blue White and Yellow Light Output 12V AC/DC 24V AC/DC 120V AC 240V AC 0.5 MSCP 6.3 Lumens 2.5 MSCP 31.4 Lumens 1 J per lamp 900 2240 mcd 900 1800 mcd 1400 3550 mcd 224 560 mcd 900 1800 mcd 3.0 MSCP 37.7 Lumens 0.49 MSCP 6.2 Lumens Rockwell Automation Publication 855-TD001D-EN-P - December 2016 49

Table 66 - Operating Voltage Light modules and sound modules 12V AC/DC (±10%) 24V AC/DC (±10%) Operating Voltage 12V AC/DC 24V AC/DC 120V AC 240V AC Table 67 - Lamp Life Ratings (Design Life) Average Life Under Static, No Vibration, Conditions (1) (2) Incandescent Modules LED Modules Strobe Modules Sound modules (1) First failures at about 35% of average life. Severe vibration can reduce life to 44% of average life. (2) Flashing applications can reduce life to 50% of average life. Table 68 - Current Consumption 110V AC, 50 Hz (±10%) 120V AC, 60 Hz (±10%) 230V AC, 50 (±10%) 240V AC, 60 (±10%) Lamp Life Rating 12V AC/DC 24V AC/DC 120V AC 240V AC 8000 hr 7000 hr 3000 hr 1600 hr 100,000 hr 15,000 hr 20,000 hr Current Consumption [ma] 24V AC/DC 120V AC 240V AC Steady LED 22 (red, amber, and yellow) 30 (red, amber, and yellow) 33 (green, blue, and white) 29 (green, blue, and white) Light only modules Flashing LED 28 (red, amber, and yellow) 30 (red, amber, and yellow) 36 (green, blue, and white) 29 (green, blue, and white) Strobe LED 35 (red, amber, and yellow) 65 (green, blue, and white) 10 Sound modules Single-tone 65 31 32 Table 69 - Flashing and Tone Frequency Attribute Value Flashing Frequency (Light Only Modules) 12V module approximately 1.5 Hz Flashing Incandescent Modules 24V, 120V, and 240V modules approximately 2 Hz Time ON/Time OFF = 1:1 Flashing LED Modules Approximately 1.5 Hz; Time On/Time OFF = 1:1 LED Strobe Modules Approximately 2 Hz (flash duration 1/50,000 second) Flashing and Tone Frequency (Light Modules/with Sound Set at Continuous Tone) Tone Frequency Tone frequency is preset at 2800 Hz Flashing and Tone Pulsing Frequencies (Light Modules/with Sound Set at Pulsing Tone) Tone Frequency Tone frequency is preset at 2800 Hz Table 70 - Decibel Rating (Sound Modules) (1) Single-tone Sound Module (SA3) Two-tone Sound Module (TA3) (1) All db(a) ratings are determined at a distance of 1 m (3.3 ft) from the sound module. Decibel Rating Maximum volume ranges from 88 db(a) or 103 db(a) (volume adjustable by DIP switch) Table 71 - Leakage Current Impact All light and sound modules can absorb up to 3 ma of leakage current from solid-state outputs without module activation. Standards Compliance Certifications UL 508 EN/IEC 60947-1 culus Listed (File No. E14840, Guides NKCR, NKCR7) CSA C22.2 No. 14 EN/IEC 60947-5-1 CE Marked 50 Rockwell Automation Publication 855-TD001D-EN-P - December 2016

Approximate Dimensions (Bulletin 855E) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 50.0 (1.9) Light Modules Vertical Mount Base 50 (1.9) Lens 67.7 (2.7) 52.0 (2.0) Cap 50.0 (1.9) 14.5 (1.57) 73.5 (2.9) Sound Module 51 (2.0) Surface Mount Base 28 (1.1) 74.3 (2.9) 50 (1.9) Pole Mount Bases Quick Release Base 830.6 (33) 190 (7.5) 630.5 (25) 430.5 (17) 131 (5.2) 280.5 (11) PM10 PM25 PM40 PM60 PM80 Rockwell Automation Publication 855-TD001D-EN-P - December 2016 51