Operating instructions RFID evaluation unit DTE / / 2011

Similar documents
Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Operating instructions. Switching amplifier DN0210 DN / / 2015

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Speed monitor D / / 2014

Installation instructions Ethernet switch EC / / 2011

Operating instructions IO-Link master CabinetLine AL19xx

Quick reference guide 3D sensor O3D3xx

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions. Standstill monitor A / / 2011

Operating instructions Optical distance sensor. OID25x / / 2015

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Manual Electronic Identification Systems BIS Processor BIS L-60_2 Profibus DP L60_2-019_828132_0304-e.p65 Deutsch bitte wenden!

Operating instructions. Monitor FD / / 2013

Installation instructions Inclination sensor EC2019 EC / / 2013

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Universal digital indicator 4½-digit

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Device manual Inclination sensor 2 axes JN /00 04/2015

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Brief instructions Illumination unit O3M950 O3M /00 03/2016

Operating instructions Optical distance sensor. OID20x / / 2014

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

Operating instructions Memory plug E /02 11/2011

Operating instructions Optical distance sensor O1D / / 2008

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Device manual Supplement. S7 library for evaluation unit DTE / / 2012

AL-DMX-Switch wall dimmer with DMX output

SK TU4-PBR Part number:

Operating instructions Optical distance sensor. O5D15x / / 2014

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

Installation Guide. O2Vxxx / / 2015

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions ClassicLine module AC / / 2012

SmartWire-DT Modules IP67

Operating Instructions IO-Link Master with Modbus TCP interface DataLine 8 Ports IP 65 / IP 66 / IP 67 AL1342

Operating instructions RFID read/write head with IO-Link DTIxxx

DM20C. LB2 I/O Series Module with 10 Digital input, 10 High Side output 5Khz Counter module. Data Sheet Doc: v1.01 / December 17 th, 2018

Operating Instructions IO-Link Master with EtherNet/IP interface DataLine 4 Ports IP 65 / IP 66 / IP 67 AL1320

Brief instructions Illumination unit O3M /00 09/2014

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Electronic pressure sensor PN7xxx

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SK CU4-EIP-C Part number:

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Lighting Controller. Data HUB YDHUB4 YDHUB4O YDHUB4OP LED Lighting Systems Installation Manual. (Version 1.3)

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

SK CU4-PNT-C Part number:

Device manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016

Operating instructions Pressure sensor. PN50xx / / 2010

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

SK CU4-PBR-C Part number:

SK TU4-CAO-C Part number:

Operating Instructions IO-Link Master with EtherNet/IP interface StandardLine 4 Ports IP 65 / IP 66 / IP 67 AL1120

System manual AS-i safety monitor AC041S /00 05/2013

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

User Guide. intouch HB_EN_inTouch Rev. ST4-A 07/17. Service Software for the product family FISCHER intouch * *

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

Operating instructions AC010S Compact AS-i E-STOP safety module

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Operating instructions Binary level sensor LMC / / 2014

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

DI20C. LB2 I/O Series Digital input & High Speed 5kHz counter. Data Sheet Doc: v1.01 / December 17 th, 2018

Original Programming Manual Fail-safe SmartPLC AC4S with fieldbus interfaces AC402S AC422S

QUICK START GUIDE IC-KP2-*

SCHMIDT Sensor interface PROFIBUS Instructions for use

BU 0220 GB. Intelligent Drivesystems, Worldwide Services SUPPLEMENTARY MANUAL BU 0220 GB PROFIBUS DP FOR FREQUENCY INVERTER NORDAC SK 200E

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Original operating instructions Fail-safe inductive sensor GI712S

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Original operating instructions Fail-safe inductive sensor GG711S

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

PS24A. RTU32M Power Supply. Data Sheet Doc: v1.00 / December 17 th, 2018

VersaMax IP Input Module

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Operating Instructions

SUBCON-PLUS-PROFIB...

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Transcription:

Operating instructis RFID evaluati unit DTE100 UK 706095 / 00 11 / 2011

Ctents 1 Preliminary note...4 1.1 Notes this document...4 1.2 Symbols used...4 2 Safety instructis...4 2.1 General...4 2.2 Installati and cnecti...4 2.3 Tampering with the device...5 3 Functis and features...5 3.1 "PROFIBUS IN" and "PROFIBUS OUT" fieldbus interface...5 3.2 "COM" cfigurati interface...6 3.3 RFID antennas...6 3.4 Requirements the Profibus DP master...6 4 Functi...6 5 Installati...7 5.1 Installati distance...7 5.2 Installati orientati...7 5.3 Mounting optis...8 5.3.1 Mounting DIN rail...8 5.3.2 Removal...8 5.3.3 Mounting plate...8 6 Electrical cnecti...10 6.1 AUX voltage supply...10 6.2 Field bus cnecti PROFIBUS IN... 11 6.2.1 Profibus address... 11 6.3 Fieldbus cnecti PROFIBUS OUT... 11 6.3.1 Factory setting of the Ethernet parameters...12 6.4 Process cnectis IO-1... IO-4...13 6.4.1 Use as input/output to IEC 61131...13 6.4.2 Use with RFID read/write heads...14 6.5 Functial earth cnecti....15 6.5.1 Mounting DIN rail...15 6.5.2 Mounting plate...15 7 Operating and display elements...16 2

7.1 Reset to factory settings...16 7.2 LED indicators...16 7.2.1 LED AUX...16 7.2.2 LED PROFIBUS...17 7.2.3 LED COM...17 7.2.4 LEDs IO1... IO4...18 7.2.5 Special device- LED indicatis...19 8 Diagnosis...20 9 Technical data...20uk 9.1 Data sheets...20 9.2 Device manual...20 10 Maintenance, repair and disposal...20 11 Approvals/standards...20 12 Scale drawing...21 Licences and trademarks Microsoft und Internet Explorer are registered trademarks of Microsoft Corporati. All trademarks and company names are subject to the copyright of the respective companies. 3

1 Preliminary note 1.1 Notes this document This document applies to the RFID evaluati unit DTE100. It is part of the device and ctains informati about the correct handling of the product. This document is intended for qualified electricians. These specialists are people who are qualified by their training and their experience to see and to avoid possible hazards that may be caused during operati of the device. Read this document before use to familiarise yourself with operating cditis, installati and operati. Keep this document during the entire durati of use of the device. 1.2 Symbols used Instructis > Reacti, result [ ] Designati of pushbutts, butts or indicatis Cross-reference Important note N-compliance can result in malfuncti or interference. Informati Supplementary note 2 Safety instructis 2.1 General Observe these operating instructis. Adhere to the warning notes the product. N-observance of the instructis, operati which is not in accordance with use as prescribed below, wrg installati or incorrect handling can affect the safety of operators and machinery. 2.2 Installati and cnecti The device must ly be installed, cnected and put into operati by a qualified electrician as the safe functi of the device and machinery is ly guaranteed when installati is correctly carried out.the installati and cnecti must 4

comply with the applicable natial and internatial standards. Respsibility lies with the pers installing the device. This is a class A product. The device may cause radio interference in domestic areas. In this case it can be necessary for the user to take appropriate measures. 2.3 Tampering with the device Tampering with the device is not allowed and will lead to an exclusi of liability and warranty. Tampering with the device can affect the safety of operators and machinery. Do not open the device. Do not insert any objects into the device. Prevent metal foreign bodies from penetrating. UK 3 Functis and features The RFID evaluati unit DTE100 integrates a Profibus DP interface and 4 channels for the cnecti of field devices. Each channel can be used either for the cnecti of an RFID antenna or as input/output to IEC 61131. The device ctrols the data exchange to the RFID antennas or the sensor/actuator level. communicates with the higher-level ctrol level via Profibus. allows device cfigurati via a web server. Applicati examples: Material flow ctrol in producti lines Warehouse management by the automatic detecti of stored products Tank management, order picking or product tracking 3.1 "PROFIBUS IN" and "PROFIBUS OUT" fieldbus interface Profibus DP-V0 / DP-V1 interface isolated from potential Baud rate 9600 baud to 12 Mbaud Max. distance between gateway and host: depending the baud rate max. 127 participants, 32 per segment 5

3.2 "COM" cfigurati interface 10 Mbps and 100 Mbps TCP/IP - Transport Ctrol Protocol/ Internet Protocol UDP - User Datagram Protocol IT functiality: HTTP server M12, twisted pair 3.3 RFID antennas The device supports up to four RFID read/write heads of type ANT51x from ifm electric gmbh. You can find informati about the matching read/write heads our website at: www.ifm.com data sheet search ANT51 3.4 Requirements the Profibus DP master Profibus DP master of class 1 (DPM1) with DPV0 support or Profibus DP master of class 1 (DPM1) with DPV1 support (recommended) By using the DPV1 services the data size within the cyclically transferred input/output data of the Profibus DP master is csiderably reduced. 4 Functi You can find detailed informati about the functi of the system in the device manual at: www.ifm.com data sheet search DTE100 Operating instructis 6

5 Installati 5.1 Installati distance Due to the internal heating of the device a minimum distance to other objects of 10 mm is to be taken into account during installati. UK A = 10 mm 5.2 Installati orientati The installati orientati can be freely selected. In a wet envirment upside-down mounting is not permitted. 7

5.3 Mounting optis 5.3.1 Mounting DIN rail The device can be installed a DIN rail of type NS35/15 or NS35/7.5. 1. Angle the device and place the fixing clamp to the upper edge of the DIN rail. 2. Press device down. 3. Simultaneously rotate the device in the directi of the DIN rail. 5.3.2 Removal 1. Press device down. 2. Simultaneously rotate the device away from the DIN rail. 3. Remove the device from the top. 8

5.3.3 Mounting plate The device can be fixed to a mounting plate using 2 screws (M4 x 35 or lger). M4 M4 UK This installati mode is recommended for vibrati and shock requirements. 9

6 Electrical cnecti The device must be cnected by a qualified electrician. Discnect power before cnecting the device. Observe the natial and internatial regulatis for the installati of electrical equipment. Ensure voltage supply to EN 50178, SELV, PELV. Cnect the device according to the indicated pin cnecti. A total current csumpti of the device of 3 A must not be exceeded. Please note the following points to ensure protecti rating IP 67: Cover the unused sockets with protective caps. Tighten all protective caps and cnectors with a tightening torque of 1 Nm. You will find matching accessories at www.ifm.com Accessories Protective cap Torque wrench ifm article number E73004 E70390 6.1 AUX voltage supply Cnect the device to the voltage supply using an M12 cnecti cable. Pin Cnecti 5 1 2 4 3 1 24 V DC 2 not used 3 0 V 4 not used 5 not used You can find matching cnecti cables at: www.ifm.com data sheet search DTE100 Accessories 10

6.2 Field bus cnecti PROFIBUS IN Cnect the device to a Profibus DP master e.g. S7-315 DP using a suitable M12 Profibus cnecti cable. 5 2 1 3 4 Note: screened cnecti cable required Pin Cnecti 1 not used 2 RxD/TxD-N (bus A) 3 not used 4 RxD/TxD-P (bus B) 5 not used UK The following cnecti cables are recommended for use with the device: Descripti Cnecti cable, straight - angled Cable plug, straight Socket, straight ifm article number E12316, E12317 E12318, E12319 E12320, E12321 6.2.1 Profibus address Profibus address delivery: 126 The address can be adapted via the integrated web server ( chapter 6.4) or a suitable Profibus DP master of class 1 or 2. 6.3 Fieldbus cnecti PROFIBUS OUT Cnect the device to the next Profibus DP participant using a suitable M12 Profibus cnecti cable. As an alternative: Cnect terminating resistor if the device is operated at the end of the Profibus DP line. 11

1 2 Pin 1 P5V Cnecti 4 3 2 RxD/TxD-N (bus A) 3 DGND Note: screened cnecti cable required 4 RxD/TxD-P (bus B) The following terminating resistor is suitable for use with the device: Descripti Terminating resistor ifm article number E12315 Ethernet cnecti COM The device features an Ethernet interface for parameter setting and diagnosis. The settings are made via a web browser, e.g. Microsoft Internet Explorer as from V7.0. Cnect the device to a PC using a suitable M12 Ethernet cnecti cable. 1 2 Pin Cnecti 1 TD+ 4 3 2 RD+ 3 TD- Note: screened cnecti cable required 4 RD- The following cnecti cable is suitable for use with the device: Descripti Ethernet cnecti cable M12 / RJ45 ifm article number E12090 6.3.1 Factory setting of the Ethernet parameters The following values are preset delivery of the device: 12

Parameters Factory setting IP address 192.168.0.79 Gateway address 192.168.0.100 Subnet mask 255.255.255.0 Auto-negotiati 6.4 Process cnectis IO-1... IO-4 Each process cnecti can be used as input/output to IEC 61131 or for cnecti of an RFID read/write head. The cnectis are set via the hardware cfigurati of the Profibus DP master. UK Pin Cnecti 5 1 2 4 3 1 L+ 2 switching input (I/Q) 3 L- 4 switching output (C/Qo) or input (C/Qi) 5 not used The evaluati unit has to be discnected before field units are cnected. Please note that the total current csumpti of the device must not exceed the value of 3 A. 6.4.1 Use as input/output to IEC 61131 Ensure the following settings in the Profibus master: Applicati Example Cfigurati in the Profibus DP master Input sensor input Output actuator output 13

6.4.2 Use with RFID read/write heads There are various operati modes when an RFID read/write head of type ANT51x is cnected: Operating mode Acyclic executi of commands via PIB Read UID from tag or write UID to tag Cyclic executi of commands Cfigurati in the Profibus DP master PIB state RWH UID RWH STRG You can find detailed informati about the available operating modes in the device manual at: www.ifm.com data sheet search DTE100 Operating instructis 14

6.5 Functial earth cnecti. To ensure trouble-free operati the device must be cnected to an earth potential free from external voltage. 6.5.1 Mounting DIN rail The cnecti is made automatically via the DIN rail. Note that the DIN rail must be cnected with the earth potential. UK 6.5.2 Mounting plate When the device is fixed a mounting plate, cnecti is made via the left fixing screw. Note that the plate must be cnected with the earth potential. 15

7 Operating and display elements 7.1 Reset to factory settings Profibus address and Ethernet parameters can be reset to the factory settings. Take the following steps: Remove all cable cnectis from the device. Insert an electrically cductive bridge between pin 1 and pin 3 the process cnecti IO-3. Cnect device with the voltage supply and wait until the yellow LED indicati AUX and IO-3 flashes at approx. 8 Hz. Discnect the device from the voltage supply and cnect it again. > > The settings are reset. 7.2 LED indicators The device indicates the current status of the interface via the status LEDs. 7.2.1 LED AUX LED green LED yellow Status Note off off no voltage supply U AUX < 5 V flashes at 2 Hz voltage supply too low 5 V U AUX 18 V off voltage supply OK 18 V U AUX 36 V flashes at 8 Hz voltage supply too high U AUX > 36 V 16

7.2.2 LED PROFIBUS LED red LED green Status Note off off flashes at 2 Hz no cnecti to the Profibus DP master cnecti to Profibus DP master exists, no cyclical data exchange cnecti to the Profibus DP master exists, cyclical data exchange running Profibus DP protocol stack in the device does not run or no cnecti to the DP master device is in the "WAIT_PRM" or "WAIT_CFG" state device is in the "DATA_EXCH" state" UK 7.2.3 LED COM LED green LED yellow Status Note off off off flashes sporadically no cnecti to another Ethernet counterpart cnecti to Ethernet counterpart exits, no data exchange cnecti to Ethernet counterpart exists, data exchange running link status "no link" link status "link", "no traffic" link status "link", "traffic" 17

7.2.4 LEDs IO1... IO4 The LED indicatis of the process cnectis differ with each cnecti cfigurati. Use as input to IEC 61131 LED green LED yellow Status Note off off interface deactivated interface in DP master not cfigured off interface activated, input L level (0 V) - interface activated, input H level (24 V) - flashes at 8 Hz flashes at 8 Hz overload or short circuit - Use as output to IEC 61131 LED green LED yellow Status Note off off interface deactivated interface in DP master not cfigured off interface activated, output L-active (0 V) - interface activated, output H-active (24 V) - flashes at 8 Hz flashes at 8 Hz overload or short circuit - 18

Use with RFID read/write heads LED green LED yellow Status Note off off interface deactivated flashes at 2 Hz flashes at 8 Hz off off flashes at 8 Hz interface activated, antenna off interface activated, tag not in the field interface activated, tag in the field overload, short-circuit or communicati error interface in DP master not cfigured - - - - UK 7.2.5 Special device- LED indicatis LED Status Note green AUX LED yellow AUX LED flashes at 8 Hz yellow IO1...IO4 LEDs flash at 8 Hz green AUX LED yellow AUX LED flashes at 8 Hz green IO1...IO4 LEDs flash at 8 Hz yellow IO1...IO4 LEDs flash at 8 Hz Device is in the service mode "emergency system started". Major error, device has to be returned. A firmware update is necessary and can be executed via the web server. Hardware fault or permanent data in the device are corrupt. 19

LED Status Note green AUX LED yellow AUX LED flashes at 8 Hz Reset to factory settings - yellow IO3 LED flashes at 8 Hz 8 Diagnosis Errors occurring during operati can be evaluated via the Profibus DP diagnostics and via the LED status indicatis (chapter 7). 9 Technical data 9.1 Data sheets Data sheets can be found at: www.ifm.com data sheet search DTE100 9.2 Device manual The device manual can be found at: www.ifm.com data sheet search DTE100 operating instructis 10 Maintenance, repair and disposal Dispose of the device in accordance with the natial envirmental regulatis. 11 Approvals/standards The EC declarati of cformity and approvals can be found at: www.ifm.com data sheet search DTE100 Approvals 20

12 Scale drawing 85 46,2 75 32,2 UK M12x1 M4 57,5 115 M12x1 43,5 21