VisoVac padmount fault interrupter

Similar documents
SACE Emax 2 Specification guide

SERIES SD3800 / SD3810 SPECIFICATION

Underground Distribution Switchgear

Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser.

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

Products Portfolio. Pole mounted Vacuum Recloser

Applying branch circuit breakers and supplementary protectors in North America

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

COOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)

Effective May 2018 Supersedes October 2017

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Medium Voltage Metal-Enclosed Power Capacitor Banks

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

Innovation for MV distribution

Medium Voltage Metal-Enclosed Harmonic Filter Systems

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Solid Dielectric Switchgear Catalog S-trid13

COOPER POWER. Types GN3E and GN3VE electronically controlled, manually closed sectionalizers SERIES. Sectionalizers Catalog Data CA270001EN

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

Solid Dielectric Switchgear

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Elastimold Molded Vacuum Recloser - MVR

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

60103 Circuit Breaker

Communications Point Data Base for Communications Protocol 2179

ELSP current-limiting backup fuse

ELSP current-limiting backup fuse

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Specif ications. S&C Remote Supervisory Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv)

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

EDR-3000 Eaton Distribution Relay

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

Applying branch circuit breakers and supplementary protectors in North America

Series 2400 Paralleling Switchgear

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

Lightweight and flexible recloser control for single-phase applications

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Grid Automation packaged solutions Optimal automation of medium voltage grids

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

Eaton s SPD Series for integration into electrical distribution equipment

MP-4000 motor protection. Protection, control and diagnostics

SecTER cabinet COOPER POWER SERIES. Sectionalizing Cabinets Catalog Data CA901001EN. General. Optional features

Quantum Chargers Enhanced AC Line Transient Immunity

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

S&C Micro-AT Source-Transfer Controls PHOTO SHEET. For use in S&C Metal-Enclosed Gear

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Protection relays.

Series NRX drawout circuit breaker and cassette rejection interlocks

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

MV Network Switchgear, Protection and Control

Specification Voltage Limiting Device

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

THE NEXT BIG THING IN DISTRIBUTION AUTOMATION

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Spectra RMS Circuit Breakers with microentelliguard Trip Units

BSPD Surge Protective Devices

SECTION DISCONNECT SWITCHES

Section 4 Ground-Fault Protection Devices

Bus Bar Protection Relay B-PRO 4000

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

I.B. 29C893C. Instructions for Installation, Operation and Maintenance of Breaker Interface Module II

EDR-3000 Eaton Distribution Relay

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Types R, RV, RX, VW, VWV, W, WV time- current curves

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FP-5000 Feeder Protection

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Common Departures Interconnecting Facilities Requirements

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Vacuum-Break Switches

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Earth-fault Relay SPAJ 110 C. Product Guide

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

Description. Installation. Power supply

Current Limiting Protector

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

Benefits, offering and references

Transcription:

Network Protector Catalog Data CA024003EN New Issue VisoVac padmount fault interrupter General The medium voltage padmount vacuum fault interrupter from Eaton delivers economical, reliable and flexible solutions for your underground distribution applications. Eaton s VisoVac is a three-phase, padmounted switchgear with high-fault interrupting capability. It includes vacuum interruption with visible isolation and visible grounding. Electrical insulation medium is air (no oil or gas required). VisoVac is available in standard and custom ordered configurations suited to meet the unique requirements of your system s needs. VisoVac padmounted switchgear utilizes proven legacy vacuum fault interrupting (VFI) breaker technology that provides higher interrupting ratings and higher operations to meet your application needs. VisoVac padmount switchgear is designed and manufactured in accordance with IEEE Std C37.74-2014, IEEE Std C37.04 and IEEE C37.09 standards. This innovative vacuum interrupting device yields operation savings: No regular maintenance Gas, oil and regulation free Advanced Eaton vacuum proven breaker technology Robust, all-in-one design reduces need for extra equipment Manual and remote operation capable 10,000 mechanical operations

Catalog Data CA024003EN Features and construction VisoVac padmount switchgear utilizes a stored-energy spring charged mechanism for OPEN and CLOSE operations. The gear comes standard with a spring charging motor on all VFI-ways with optional spring charge motors for all switched-ways. VisoVac also comes standard with a manual spring charge handle that allows for dead-start closing with out the need for control power. Each way comes with OPEN and CLOSE pushbutton controls and spring charge indication. The switchgear is available with visible isolation and visible grounding capability. These features are mechanically interlocked internally. The switchgear is available in the most commonly used ac and dc voltages for control power and comes pre-wired to reduce on-site field install time. Figure 1. V3 Series front viewing window VisoVac padmount fault interrupter V3 Series visible isolation A three-pole, group-operated, non-load break, air insulated, isolation switch is included internal to the enclosure. This feature also includes a viewing window to confirm a physical disconnect between the switchgear and underground cable. A mimic diagram physically linked to the operating mechanism shows exactly what position the isolation switch is in. The isolation switch is mechanically interlocked internally with the vacuum interrupting mechansim. The isolation switch is also mechanically interlocked internally with the grounding switch to prevent the grounding switch from being operated while the isolation switch is in the CLOSED position Figure 2. V3 Series front mimic diagram Figure 3. V3 Series VisoVac internal layout Front mounted position indicator Control power & voltage sensing Deadbreak bushing internal CTs Visible ground Visible disconnect Vacuum interrupter Vacuum interrupting mechanism 2

VisoVac padmount fault interrupter V3 Series visible grounding A three-pole, group-operated grounding switch is included internal to the enclosure. This feature also includes a viewing window to confirm a physical ground connected to the underground cable. The grounding switch is equipped with mechanical interlocks located internal to the enclosure to prevent operation of the grounding switch while the visible isolation switch is in the CLOSED position. A mimic diagram physically linked to the operating mechanism shows exactly what position the grounding switch is in. Vacuum interruption VisoVac fault interrupter s vacuum interrupting mechanism utilizes proven Eaton technology which allows for an exceptional 25 ka or 40 ka interrupting rating. Eaton s environmentally friendly medium voltage interrupters are capable of reliably switching highstress currents robustly and carrying their rated continuous current without forced cooling. The interrupting mechanism was designed for applications where space is a premium such as padmount environments. The load break mechanism is available with up-to a 900 A continuous current rating and comes with a mechanical endurance of 10,000 operations. The three-phase vacuum interrupter can be opened manually or remotely via SCADA, protective relaying or pendant. The vacuum interrupter is equipped with a mechanical indicator and nonresettable operations counter. Eaton vacuum interrupters are the industry standard in quality. Catalog Data CA024003EN Each Eaton vacuum interrupter is tested throughout the manufacturing process and once again before packaging A dielectric withstand test and a vacuum assurance test are performed on every interrupter Additionally, Eaton also incorporates a sequential bar code that allows us to track material lots, as well as the operators involved with building each interrupter in a database With well over three million Eaton vacuum interrupters in service around the world, our customers testify that our vacuum interrupters are one of the most critical and reliable components Spring charge mechanism VisoVac utilizes legacy Eaton vacuum breaker fault interruption technology. Each VFI way comes standard with a spring charge motor operator located internal to the gear. When springs are fully charged the switch is capable of an O-C-O operation via the pushbutton control without the need for control power. The gear also includes an integral manual charging handle to allow recharging the stored energy mechanism if power is lost and springs are discharged. The manual spring charge handle is front plate mounted and easily accessible without the need for any tools. Figure 4. Vacuum interrupter status indicator. Left image shows status indicator in the closed position, the image on the right shows the status indicator in the open position. Charged Display 3

Catalog Data CA024003EN VisoVac padmount fault interrupter Ratings and specifications Table 1. General Specifications Feature 25 ka 40 ka Rated Maximum Voltage, 50/60 Hz Maximum Design Voltage, kv 15.5/17.5 15.5/17.5 Impulse Withstand Voltage Line to ground (kv BIL) 95 95 Open Contact (kv BIL) 95 95 Withstand Voltage, 60 Hz 1 min withstand, ac kv 35 35 5 min withstand, dc kv 53 53 Continuous Current, 50/60 Hz (A) 600/900 600/900 Load Break Current, 50/60 Hz (A) 600/900 600/900 Momentary Withstand (asym pk.) 65 104 1s sym withstand rating, ka 25 40 Sym interrupting rating, ka 25 40 Fault Close (asym pk.) 65 104 5s withstand in ground position, ka 15 15 0.2 withstand in ground position, ka 45 45 Mechanical Operations 10,000 10,000 4

VisoVac padmount fault interrupter Eaton standard control front/cable rear padmount offerings 1 V1 Series One line diagram MODEL 5-V1 Nominal voltage (kv) Style code* VP5162201X5T Product details Catalog Data CA024003EN 1 V1 Series models provided with vacuum fault interruption and switching 2 V3 Series models provided with vacuum fault interruption, switching, visible isolation and visible ground Location of visible isolation and ground on V3 Series models. MODEL 6-V1 VP5162221X5T VFI SW Isolation Isolation Ground Ground MODEL 9-V1 VP5162222X5T VFI-Way Switched Way MODEL 5W2-V1 VP5162223X5T Control front/cable rear models are designed with control access and switch operators on the front with cable terminations in the rear. Available in V1 and V3 Series. MODEL 6W2-V1 VP5162224X5T Double-sided models are designed with control access, switch operators, and cable terminations on the front with the same configuration in the rear. Only available in V1 Series, consult your local Eaton representative for details. Single-sided models are designed with control access, switch terminations and cable terminations on the front with no access in the rear. Only available in V1 Series, consult your local Eaton representative for details. 2 V3 Series One line diagram Nominal voltage (kv) Style code* *Style code examples listed include the following standard VisoVac features: All models are control front/cable rear and dead-front MODEL 5-V3 VP5162201Y5T Padmount enclosures are painted Munsell Green 7.0GY3.29/1.5 All VFI-Ways include Eaton Digitrip 1150V and Eaton current sensors MODEL 6-V3 VP5162221Y5T All Ways include stored energy operation and include a spring charge motor. Capable of remote operation without the need of additional motor operators. All Ways are rated 600A continuous with 25kA sym RMS fault interruption and withstand capability MODEL 9-V3 VP5162222Y5T One internal CPT provided for 120VAC control power MODEL 5W2-V3 VP5162223Y5T MODEL 6W2-V3 VP5162224Y5T S Source T Tap SW Switched-ways (loadbreak) VFI Vacuum Fault Interrupting Ways 5

Catalog Data CA024003EN Applications Underground distribution sectionalizing VisoVac fault interrupters are an ideal solution for underground distribution sectionalizing. VisoVac fault interrupters can be installed to provide local isolation and three-phase overcurrent protection for radial loads. Alternatively, VisoVac fault interrupters can be used for single-ways or up to six-way switching configurations with or without the visible isolation and visible grounding. Utilizing Eaton s configured-to-order services, a solution can be designed to tailor fit the end user s requirements. VisoVac fault interrupters can be placed inside an enclosure for pad-mounted applications. Enclosures conform to the security requirements of IEEE Std C57.12.28-2005 standard. VisoVac padmount fault interrupter VisoVac fault interrupters are also available with an Eaton Digitrip controller that allows for unique control settings, overcurrent protection and the ability to communicate with utility feeder automation systems such as Eaton s Cooper Power series Yukon Feeder Automation platform. Consult your local Eaton representative for more information. Figure 9. Underground distribution sectionalizing applications 6

VisoVac padmount fault interrupter Accessories Automatic transfer control Eaton s ATC-900 brings intelligence, adaptability, supervisory and programming capabilities to automatic transfer switch equipment. Extreme reliability makes the ATC-900 ideal for mission critical applications where VisoVac is used for auto transfer switching. Typically used for utility-to-utility, utility-to-generator, generator-togenerator and three source transfer systems, the ATC-900 can address virtually any system requirements. Ease-of-use is a major benefit of the ATC-900 controller. With a simple, powerful user interface, many intuitive operating features are included. LED indications and a TFT based color display provide high visibility. Simple arrow keys are used for quick screen navigation. No codes or abbreviations are used to avoid potential confusion and/or slow operation, and data screens are grouped for ease of viewing and edits. The ATC-900 is available in one standard model that offers a variety of monitoring and control features such as selective and automatic load shedding, remote load testing, and event logging/ recording. Flexibility is another important benefit, allowing field configurability and expandability in the future with add-on accessory modules and hardware. The ATC-900 is available with Open (break-before-make) and Close (make-before-break) transition switching. For more information please reference Eaton ATC-900 Instruction Bulletin - IB140012EN. Figure 10. Automatic transfer control interface Catalog Data CA024003EN Digitrip 1150 V controller Eaton s Digitrip 1150 V is used for advanced current and voltage protections, metering and communication functions. The Digitrip 1150V comes standard with energy harvesting overcurrent protection capability, during the loss of power or voltage sag from a fault the Digitrip can use the energy of the fault to maintain protection and initiate a trip in the absence of control power. The controller continuously analyzes secondary current signals from the current sensors and when preset current levels and time delay settings are exceeded, sends a trip signal to the trip actuator of the vacuum interrupter. The trip actuator causes tripping of the vacuum interrupter by providing the required mechanical force for tripping. The trip actuator is automatically reset each time the vacuum interrupter opens. The current sensors, controller and vacuum interrupter are fully tested as a system for time-over-current response over the entire current range up to the interrupting rating of the vacuum interrupter. The Digitrip 1150V trip unit can provide the following protection and metering functions: 51 Phase Long Delay 50T Phase Short Delay 50 Phase Instantaneous 51/50G Ground Fault 37 Phase Loss (Current Based) 46 Current Unbalance 27 Undervoltage 59 Overvoltage 81U Underfrequency 81O Overfrequency 47 Voltage Unbalance 32 Reverse Power Thermal Memory analyses the thermal loading of VFI Metering - I, V, kva, kvar, kw, THD, PF *Voltage sensors required for power and voltage related functions Eaton CH-Type current sensors are provided on Ways using the Digitrip 1150V. CH-Type sensors come standard with 1A secondaries and are available with the following primary current ratings: 100A, 200A, 300A, 400A, 600A, 800A & 1000A. For more information please reference Eaton Digitrip 1150V Instruction Bulletin - I.L. 66A7535H02 Figure 11. Digitrip 1150 V controller 24 character LED display LSIG mimic curve Cause of trip LED Rating plug Manual selection interface Real time LED indicators 7

Catalog Data CA024003EN VisoVac padmount fault interrupter Arc reduction maintenance system (ARMS) Eaton s Arcflash Reduction Maintenance System technology is based on the realization that when working on energized electrical equipment, a fault that occurs within the gear or downstream needs to be cleared as quickly as possible. While this seems obvious, in actual installations, intentional delays are included in upstream devices to ensure selective coordination with downstream devices. This means that if a fault were to occur inside the equipment the downstream breaker may never clear the fault regardless of how much delay is or isn t programmed in the upstream device. While other Eaton arcflash technologies are available, the Arcflash Reduction Maintenance System comes standard with the Digitrip 1150V. This patented technique provides faster than instantaneous clearing times. When the Arcflash Reduction Maintenance System is enabled, the internal digital logic is bypassed by a faster than instantaneous analog trip circuit based on user preset values. In this mode, the Digitrip is set to hair trigger and issues subcycle tripping. Total clear is estimated within 4 cycles. When properly used, PPE requirements can be considerably reduced. Communications module A communications module is used for remote and secure access to view or change the Digitrip settings, remote control of the VisoVac fault interrupter and gain status of the vacuum interrupter, isolation and grounding positions. The communications module provides easy to configure data communications with seamless integration into the user s central control system. Supports secure DNP3 and INCOM protocols. Configured-to-order protection and control options Eaton can provide a customized protection and control package configured to meet each user s unique application requirements. Protective relays like Eaton s Cooper Power series Edison Idea relay, relays from Schweitzer Engineering Laboratories or General Electric, or other suppliers can be designed and come ready to install. Please consult factory for details. 8

VisoVac padmount fault interrupter Dimensions V1 Series double-sided Catalog Data CA024003EN A C D E B Table 2. Dimensional information Style kaic A B C D E 1 way 3 way 4 way 5 way * 6 way 25kA 60 80 18.5 25 80 40kA 65 80 18.5 25 80 25kA 60 80 18.5 25 80 40kA 65 80 18.5 25 80 25kA 60 80 18.5 25 80 40kA 65 80 18.5 25 80 25kA 60 80 18.5 25 80 40kA 65 80 18.5 25 80 25kA 60 80 18.5 25 80 40kA 65 80 18.5 25 80 *Dimensions subject to change based on control power requirements 9

Catalog Data CA024003EN Dimensions V3 Series control front/cable rear VisoVac padmount fault interrupter A 1 WAY E 3 WAY F 4 WAY G 5 WAY H 6 WAY I VT ACCESS VT ACCESS A C D B NNote: V1 Series control front/cable rear models have the same dimensions as V3 Series control front/cable rear models 10

VisoVac padmount fault interrupter Catalog Data CA024003EN Table 3. Dimensional information Style kaic A B C D E F G H I 1 way 3 way 4 way 5 way 6 way 25kA 60 68 25 32 54 40kA 65 68 25 32 56 25kA 60 68 25 32 80 40kA 65 68 25 32 80 25kA 60 68 25 32 107 40kA 65 68 25 32 107 25kA 60 68 25 32 128 40kA 65 68 25 32 128 25kA 60 68 25 32 149 40kA 65 68 25 32 149 Table 4. Ordering information Style code 1 VisoVac Voltage Rating Voltage Impulse rating Continous current rating Fault withstand rating Enclosure color Switched ways 2 VFIways 2 VP 5 1 95kV 6 600A 2 25kA 1 ANSI 70 - Gray 0 N/A 1 one Y 7 17.5kV 9 900A 4 40kA 2 Munsell Green 7.0GY3.29/1.5 1 one 2 two X 2 two 3 three W 3 three 4 four V Visble isolation/ ground Series model 3 Required V3 control front/ cable rear N/A V1 control front/ cable rear N/A V1 double-sided N/A V1 single-sided Control voltage 1 24 VDC A 2 48 VDC C 3 110 VDC T 4 125 VDC Z Accessories 5 ATC-900 automatic transfer control Communication module Control power transformer Customized relay panel 6 4 four 5 five 5 120 VAC V Voltage sensing 6 six 6 220 VAC X None 7 240 VAC Notese: 1. Style Code for general reference only, consult factory with specific application requirements 2. Single and Multi-way options available in different arrangements, consult factory with specific application requirements 3. V3 Series are only available in control front/cable rear models; V1 Series are available in control front/cable rear, double-sided and single-sided models. Consult factory for V1 single-sided model dimensions. 4. Switched ways available with mechanical interlocking used for Open Transition (break-before-make) applications. 5. Eaton Digitrip 1150V provided on all VFI-Ways as standard unless a customized relay panel is specified. Eaton current sensors required with Digitrip. 6. Consult factory with application requirements for customized relay panels 11

Catalog Data CA024003EN VisoVac padmount fault interrupter Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton's Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. CA024003EN December 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's VisoVac fault interrupter product information call 1-877-277-4636 or visit: www.eaton.com.