X47.CE Product Guide

Similar documents
PC485.S5 Module Product Guide

MCM4 Product Guide Table of Contents

ST7 ICP Tool Product Guide

Modular Room Control (MRC) Series Expansion Board

Designer Series Product Guide

E528 Smart Digital Thermostat Product Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Temperature controller Ducted systems

THERMOSTATS & CONTROLLERS

Custom Controller Installation Instructions

S5XX Switch Series Product Guide

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Wireless General Purpose Adapter (WGA100) Installation Instructions

ETM-2050/ETM-2051 Service Manual

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

LTEC Heat Pump DDC Controller

ETM-2040 Service Manual

rcc.1081 Installation Instructions

NSD/M1 Installation Instructions

EP/2 Installation Instructions

FX Input/Output (I/O) Modules XM07 and XM14

TC-9102 Terminal Controller

ECON-ZIP-BASE. ZIP Economizer Base Module

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

TF243 Series Digital Thermostat Fan Coil Unit Control

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

4-step Chiller and Heat Pump Controller

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

Fast Route to Reliable Energy Savings ZIP Economizer

Smart Equipment Controls (SEC)

Infosystem Remote Touchscreen Installation Instructions

Thermoelectric Cooler Controller TED1000

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

Rack Input Module Installation Instructions

SE7600E Series Application Guide

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

LTEC Unit Ventilator DDC Controller

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

RWD68U Universal Controller

Installation & Operation Guide

FCU-MULTI Modbus Fan Coil Unit Controller

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

EX-RC1 Remote I/O Adapter

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Temperature Controller (Heat Pumps)

Product Manual. TZ Centurion Port Links. TZ Centurion Port Link 7101CL TZ Centurion Multi Port Link 7105CL

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

TEC Unit Conditioner Controller

Installing VO2 Analog Output Boards

Dip Switch settings.

SmartStruxure Lite Solution

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC

clarity 3 Programmable Controller

Electrical Actuators

Ethernet Adapter Installation Instructions

Heating Circuit Controller

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

T775S Series 2000 Expansion Module

Wireless Sensor Adapter (WSA10) Installation Instructions

Casambi CBU-ASD. Bluetooth 4.0 Wireless Control Unit for LED Drivers. Features. 1 Description

TECHNICAL PRODUCT DATASHEET

Room Controllers. SC3000 Relay Pack

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

RDF Series Room Temperature Controllers

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

ASI Systems ML5720A Series

ASI Systems ML5740A Series

basicdim Wireless Wireless module for basicdim

NCH-1000 (Multiple Breaker Types) Installation Instructions

PSC-WCM-050-XX Single Channel Wireless Fixture Control Module

TEC Terminal Box (VAV) Controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Expansion Module HZS 541-1S

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Semi flush-mounted room temperature controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD

Installation & Operation Guide

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Tstat8. Bacnet Thermostat

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Measure & Control Temperature & CO2 levels with analog & digital I/O

Transcription:

X47.CE Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Features... Page 2 Technical Overview... Page 3 Installation... Page 5 Commissioning... Page 5 Wiring Specifications... Page 6 Technical Specifications... Page 7 Ordering Specifications... Page 8 References... Page 9 Document Revision History... Page 9 Rev. 3.0 Date 3/17/2017 1

Overview and General Concepts The X47.CE Universal Relay Pack (PN 201-147.CE) is an INNCOM Integrated Room Automation System (IRAS) device designed for guestroom controls. The X47.CE provides five relay outputs used to switch a variety of loads, including fan coil units (FCU) and light-duty general loads. The X47.CE can integrate with and receive data from multiple points throughout the IRAS using low-voltage wired communication (S5bus) or radio frequency (RF) communication (when connected to a PC502). The X47.CE is a 220-240 VAC line power controller. Figure 1. X47.CE Features Controls a full range of FCU systems, complex light-duty lighting circuits, and other guestroom applications from 24 277VAC Supports three communication modes: S5bus, IR, and RF Installs inside FCU/HVAC enclosures Connects to remote thermistor (04-1096, 04-1096.MOD 04-1095) for external temperature sensing (+/- 1%temperature accuracy at 25 C) Enclosed to protect sensitive circuitry Complies with agency-approved recommendations for worldwide usage X47.CE FCU Controller: In combination with the INNCOM e4 Smart Digital Thermostat, the X47.CE FCU controller is a feature-rich, costsaving energy management tool. Communication using RF or INNCOM s IR Eye5 Infrared Transceiver adds to its installation versatility. (See the References section of this document for information on INNCOM's Energy Management System.) Rev. 3.0 Date 3/17/2017 2

Safety: The X47.CE is intended for indoor use only. To comply with industry standards in the U.S., Canada, Europe, and Asia, the device is equipped with an enclosure that protects the relays and circuitry from the environmental. The X47.CE can be installed in a NEMA-type electrical box in the field and is permanently wired according to guidelines from the National Electrical Code. The X47.CE has agency approval from FCC, IC, CE Mark, and CQC. Technical Overview The X47.CE has five power relays and a local logic controller card combined in one assembly. Other features include Blade connectors for 220VAC 240VAC Four screw openings in the bottom enclosure for mounting in a NEMA enclosure LED: The X47.CE has one diagnostic LED, which will blink on and off to indicate activity. It also signals during startup and the commissioning process (see below). Headers: The X47.CE contains the following headers: H1: In Circuit Programming Header H2: Digital Input/Output 0V or 5V H3/4: External temperature sensor headers; Pin 1, 2-GND, Pin 3-10k NTC H5 IR Eye5 header H6: 100VAC power and relay output header H8: Analog output header; Pin 1-GND, Pin 2 Analog output 0 10VDC, Pin 3 Analog output 0 10VDC H9: 5 pin S5bus I/O header H10: ES1 header H11: RS485 adapter header (PN 203-250) Relays: Tables 1 and 2 show the Relay Output specifications for the X47.CE; Table 3 shows the relay functions for typical applications. Rev. 3.0 Date 3/17/2017 3

Table 1: X47.CE Relay Output Specifications, 220-240VAC Input model K1 K2 Rating 3A, 277VAC Gen. Purpose 3.6FLA, 21.6LRA 3A, 277VAC, Gen. Purpose, 2.2FLA, 13.2LRA, 0.7A sealed, 7A inrush Pin Assignment P8 P9 K3 3A, 277VAC, Gen. Purpose, 2.2FLA, 13.2LRA, 0.7A sealed, 7A inrush P10 K4 3A, 277VAC, Gen. Purpose, 2.2FLA, 13.2LRA, 0.7A sealed, 7A inrush P2 K5 3A, 277VAC, Gen. Purpose, 2.2FLA, 13.2LRA, 0.7A sealed, 7A inrush P3 Common 1 K1, K2, K3 P5 Common 2 K4, K5 P4 Table 2. X47.CE Relay Functions for Typical Installations 4 Pipe, 3 Fan, Heat/Cool FCU 2 Pipe, 3 Fan, Cool Only FCU Heat Pump, 2 Fan 2 nd Stage Heat Heat Pump, 3 Fan Speeds PTAC, 2 Fan with Heat Strip K1 High Fan High Fan High Fan High Fan High Fan K2 Medium Fan Medium Fan W2 2 nd Stage Heat Medium Fan Not Connected K3 Low Fan Low Fan Low Fan Low Fan Low Fan K4 Cool Signal Cool Signal Y-Compressor Y-Compressor Y-Compressor K5 Heat Signal Not Connected B/O-Reversing Valve B/O-Reversing Valve W-Heat Rev. 3.0 Date 3/17/2017 4

Installation CAUTION!! The X47.CE installer must be a trained, experienced service technician. All wiring must comply with local codes and ordinances. The X47.CE is intended for indoor use only. Failure to follow the instructions provided with the product could damage the product or cause a hazardous condition. The ratings given in the instructions and on the product should be checked to make sure the product is suitable for the application. Table 1 gives relay functions for the line-power version; Table 2 provides relay functions for typical installations. To install the X47.CE: Use four 6/32 ½ sheet metal screws to mount the X47.CE inside a NEMA enclosure or FCU using the four screw holes in the bottom enclosure. See Figure 2 for line-voltage and 24VAC power supply connectors See Figure 3 for X47.CE headers Note: The instructions above describe the typical installation of the X47.CE. Commissioning To participate in the network, the X47.CE must be commissioned by teaching it identification information. The following commissioning instructions use an X47.CE connected to a PC502 on the S5bus (for 2.4 GHz wireless RF communications) and an E529 thermostat: 1. Power up the X47.CE (LED blinks rapidly). 2. Enter the Service Mode on the e529 thermostat (press and hold the F/ C button; press and release the OFF/AUTO button; press and release the DISPLAY button; release the F/ C button). 3. On the E529 LCD, scroll to Adr and press OFF/AUTO. 4. Set the address to teach the X47.CE (typically 14). 5. Press OFF/AUTO. The display will show bnd. 6. Use a small point (e.g., the end of a straightened paper clip) to press the Bind switch on the X47.CE once. This sends a Bind request toward the thermostat. Rev. 3.0 Date 3/17/2017 5

7. The thermostat will send a Bind offer to the X47.CE. If it is accepted, the thermostat will buzz loudly. The X47.CE will reset. 8. Test the X47.CE functionality. After binding, use the E529 to set Room ID, PAN ID and RF Channel. See property-specific instructions for further guidance. Wiring Specifications Figure 1 shows the X47.CE line-voltage connectors; Figure 2 shows the headers; and Figure 3 shows a typical connection to a Fan Coil Unit Figure 2 Connectors Line-Voltage Connections: The phase, neutral, earth, and relay output connections are defined on the product label. Low-Voltage Power/Communications Connection: The X47.CE can provide 12VDC 240mA output class-2 power and S5bus for IRAS devices. Figure 3 X47.CE headers Rev. 3.0 Date 3/17/2017 6

FCU Typical Fan Coil Unit Connections HEAT X07 Earth COOL M LOW FAN MED FAN HIGH FAN P10 P9 P8 P1 P2 P3 P4 P5 P6 LOW MED HIGH P7 GND HEAT COOL VCOM FCOM NEU LINE LOGIC BOARD * NEUT/L2 LINE/L1 *Note: Typically Valve and Fan Power use L1/Line Power Figure 4 Typical FCU Connections Technical Specifications Table 4. Technical Specifications 201-147.CE Class-2 Output Voltage/Power Parameter Memory Temperature range, Operating Storage Mounting Dimensions 12VDC, 240mA (See table below to determine final output power) Non-volatile 32 to 140 degrees F (0 to 40 degrees C) -40 to 158 degrees F (-40 to 70 degrees C) 15 to 99 percent RH 4 hole mounting 6/32 bit, ½ screw 2 ¾ W x 3 ½ H (excluding screw tabs) x 1 ½ D (at deepest part) 70 mm W x 88 mm H x 38 mm D Approvals FCC, IC, CE MARK, CCC Current consumption is determined using the following formula: 30mA + (n 20mA) where 30mA is the current consumption of the logic board and n= the number of actuated relays. Table 5. Current Consumption Configuration Maximum Load (including logic board) All relays actuated 130mA Rev. 3.0 Date 3/17/2017 7

Note: Current consumption values of the X47.CE with actuated relays should be deducted from class-2 output power rating in Table 1 in order not to overdrive the power supply. The X47.CE should not be used to provide more than 70mA of external class-2 power. Ordering Specifications Table 6: X47.CE Ordering Model # 201-147.CE Description X47.CE 220-240VAC 50/60Hz w/ 5 relay actuator and Power Supply, HVAC Logic, Grey Housing Table 7: X47.CE Harness Ordering Model # 62-1464.R X47.CE 24VAC Harness 62-1465.B X47.CE Low-voltage cable (H3, H4, H8, H9) 62-1511.A X47.CE Low-voltage cable (H2, H5) No harness is supplied for the X47.CE with line voltage power supply option. Table 8: Thermistor Ordering Model # 04-1094.MOD External Thermistor 04-1096 Ruggedized Thermistor Table 9: RS-485 Adapter Ordering Model # 203-250 RS-485 Communication Module Rev. 3.0 Date 3/17/2017 8

References INNCOM s Standalone Energy Management System e4 Smart Digital Thermostat Model e528 e529 Users Guide X47.CE Programming Application Note Document Revision History REVISION DATE ISSUED REASON 1.0 30-Aug-2013 First issue 2.0 14-Nov-2013 Added Ordering tables; revised binding procedure 3.0 17-Mar-2016 Rebrand as per Honeywell Standards The material in this document is for information purposes only. The content and the product it describes are subject to change without notice. Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell. Copyright 2017 by Honeywell International, Inc. All Rights Reserved. Honeywell l 277 West Main Street l Niantic, CT 06357 l Phone: 1.860-739-4468 l www.inncom.com Rev. 3.0 Date 3/17/2017 9