InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

Similar documents
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Precision Cooling Mission Critical Air Handling Units

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

WO P-NF-L-M-407c Spec Submittal

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

CTC Low Temperature Process Chillers

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax:

SmoothAir Modular Precision Cooling

Reliability and extended operation

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

J&M Fluidics, Inc. Company Product Overview

AIR COOLED CONDENSERS

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

DCG Commercial. Submittal Data Form

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

AIR COOLED MODULAR RECTIFIER

Precision Cooling. Precision Cooling Advantages

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

GP SERIES Packaged Chillers

U-Match Series DC Inverter Service Manual PRODUCT

Free-Standing Type 12 Enclosures

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Datasheet.

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

DCG Series. Submittal Data Form. 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

This image cannot currently be displayed. Sarel Pelser. ABB Group May 27, 2014 Slide 1

DUCTED SPLIT SYSTEMS With Scroll compressors

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Sealed Enclosure Cooling Air Conditioners

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

HIGH EFFICIENCY Central Chiller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Fast Route to Reliable Energy Savings ZIP Economizer

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Model VDL 115 Vacuum drying chambers for flammable solvents

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

S66 Series Electronic Fan Speed Control

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Model KB 400 Cooling incubators with compressor technology

5000 SERIES UNINTERRUPTIBLE POWER SYSTEMS

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

PF 3100 BMS CARD PRO.FIRE

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Ecoflair Air Economizers

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

SO-LOW LAB FREEZERS TO -85 C

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

Blue e+ chillers with the principle

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

Level-Lance Model 5400A

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

ASCO SERIES 300 Manual Transfer Switch Solutions

Siemens BACnet Programmable TEC Unit Conditioner Controller

shop online:

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Wastewater Solutions. Featuring Meltric s DECONTACTOR TM Series Switch-Rated Plugs, Receptacles and Electrical Connectors. meltric.

More than 150 integrated application-specific functions

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Company, Simplex Onsite, providing nationwide load bank rentals.

Introducing the Heat Wheel to the Data Center

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

Semi-hermetic Air-cooled Condensing Units

Transcription:

Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton :: 7.0 17.5 kw Features and Benefits Built for critical applications Two-stages of cooling allows for more precise cooling as well as a 50% refrigeration backup in the event of a leak or component failure All-in-one design to allow a single point of connection 16-gauge cabinet construction for use in rugged, industrial applications Modular design allows improved maintenance and spare parts availability Form-C dry contacts for alarm outputs allow remote monitoring Standard motors are totally-enclosed and rated for Class 1 Div 2 UL 508A Listed electrical panels for safety Fully CSA certified to UL 1995 (general purpose) and 1203 (hazloc) standards Industry standard voltage configurations, including: 480V 3ph 60Hz; 3ph 60Hz; 3ph 50Hz Options and Accessories Built in NFPA-496 compliant building purge & pressurization Chemical and/or high efficiency particulate filtration Electric heat from 40kW Air quality monitoring for explosive, toxic, or corrosive gases Corrosion resistant coil coatings Corrosion resistant condenser section Low ambient controls, down to -70 F (-55 C) Fresh air stack packages Multiple unit control Designed to allow full environmental control of your building. Specific Systems InPac units are engineered and proven to stand up to the rigors and harsh conditions of corrosive and hazardous environments. The InPac line is built to demanding industrial and military specifications and features corrosion resistant coatings and inherent redundancy. Our InPac units are engineered from the ground up to make your job easier. In fact, our modular design eliminates the need for the integration of systems from multiple vendors. Instead, using a Specific Systems InPac HVAC allows for a single point of connection to perform all of the functions otherwise requiring multiple types of units. InPac systems are custom-engineered and built-to-order for each customer using a time-proven assembly method. Standard unit cabinets are manufactured of 16-gauge galvanized steel with all-welded construction. The completed cabinet is painted with a finish to help fight corrosion. Standard fan module consists of a motor and direct drive blowers. If any auxiliary (stand-by) fan is needed, it can be provided along with the necessary controls to automatically purge and pressurize the building. The auxiliary fan serves secondarily as a redundant fan should a failure occur to the primary fan. Starting with our time-proven industrial DX air conditioning system, you can include many options, including those listed at left. This all-in-one design allows quicker and more efficient integration into your structure. Form-C dry contacts for alarm outputs are standard, with full remote controls available through an optional BacNet or LonWorks compatible PLC.

Electrical Data Capacity Data Preliminary Dimensions CFM @ 0.50" S.P. Nominal Capacity Model 60Hz 50Hz 60 Hz 50 Hz 624 1390 1160 24000 19920 636 1390 1160 36000 30000 648 2000 1667 48000 40000 660 2000 1667 60000 50000 Refrigerant Capacity/Circuit Model Standard w/receivers 624 4 11.5 636 4 11.5 648 4 11.5 660 4.3 12.5 Model Total Cap. @ 60Hz, 80 DB / 67 WB Entering Evap. 75 F (24 C) 85 F (29 C) 95 F (35 C) 110 F (43 C) 120 F (49 C) 624 27000 25600 24200 21900 20400 636 50800 48200 45600 41300 68400 648 54000 51200 48400 43900 40900 660 70300 66900 63300 57800 53900 Model Total Cap. @ 60Hz, 80 DB / 67 WB Entering Evap. 75 F (24 C) 85 F (29 C) 95 F (35 C) 110 F (43 C) 120 F (49 C) 624 7.90 7.50 7.10 6.45 6.00 636 14.90 14.15 13.35 12.10 11.25 648 15.85 15.00 14.20 12.90 12.00 660 20.60 19.60 18.60 16.95 15.80 Sensible Cap. @ 60Hz, 80 DB / 67 WB Entering Evap. 624 17800 17200 16600 15700 15200 636 30900 29800 28600 26800 25800 648 35600 34400 33300 31400 30400 660 45600 44100 42400 40100 38600 Sensible Cap. @ 60Hz, 80 DB / 67 WB Entering Evap. 624 5.25 5.05 4.85 4.60 4.50 636 9.01 8.75 8.40 7.85 7.50 648 10.45 10.10 9.75 9.20 8.95 660 13.40 12.95 12.45 11.80 11.30 Total Cap. @ 60Hz, 80 DB / 61.8 WB Entering Evap. 624 24600 23400 22000 20000 18700 636 46000 43700 41200 37300 34600 648 49300 46800 44100 40100 37500 660 64400 31200 58100 52900 49600 Total Cap. @ 60Hz, 80 DB / 61.8 WB Entering Evap. 624 7.25 6.90 6.50 5.90 5.50 636 13.50 12.80 12.10 10.95 10.15 648 14.50 13.75 12.95 11.75 11.00 660 18.90 17.95 17.00 15.50 14.55 Sensible Cap. @ 60Hz, 80 DB / 61.8 WB Entering Evap. 624 22000 21400 20900 19600 18700 636 37600 36500 35300 33400 32000 648 44100 42900 41500 39200 37500 660 56000 54400 52900 50100 48400 Sensible Cap. @ 60Hz, 80 DB / 61.8 WB Entering Evap. 624 6.45 6.30 6.10 5.75 5.50 636 11.00 10.70 11.35 9.80 9.40 648 12.90 12.60 12.20 11.50 11.00 660 16.40 16.00 15.50 14.70 14.20

Electrical Data Capacity Data Preliminary Dimensions 32.00 14.00 78.50 Filter Extension 94.87 30" 18.00 23.75 42" 39.50 6.00 30" 24.00 24.00 25.50 27.00 Dimensions shown are representative of our standard vertical, through-the-wall explosion proof Class 1 Div 2 HVAC and pressurization system All dimensions should be considered preliminary, and this drawing should not be used as a final construction document s are provided as standard for maintenance. Any required clearances should be confirmed with local regulations or statutes for electrical systems Electrical and capacity data provided in this document is accurate at the time of publishing, but Specific Systems reserves the right to modifiy components in future systems, thereby negating the accuracy of these numbers. Please verify all data with your sales representative and subsequent project engineer

600 Series Electrical Data MODEL 624 Compressor Motor RLA 8.3 5.1 6.1 5.1 5.1 3.3 20kW, Amps (Actual kw) 53.3 (20.1) 26.0 (21.6) 53.3 (20.6) 31.2 (22.4) 29.3 (18.8) 21.7 (21.6) 15kW, Amps (Actual kw) 37.8 (13.8) 18.5 (15.4) 37.3 (13.8) 22.5 (14.9) 24.9 (15.6) 15.5 (15.4) 10kW, Amps (Actual kw) 26.0 (10.3) 13.0 (10.8) 26.0 (10.3) 16.0 (11.2) 14.7 (9.4) 10.8 (10.8) w/o Auxiliary Fan 26.5 12.2 18.8 11.6 11.6 9.3 w/auxiliary Fan 32.25 14.7 23.8 13.8 13.8 11.3 MCA w/o Aux Fan 28.6 21.9 41.4 22.1 22.1 17.9 MOP w/o Aux Fan 35.0 25.0 45.0 25.0 25.0 20.0 MCA w/aux Fan 34.3 21.9 46.4 24.3 24.3 19.9 MOP w/aux Fan 40.0 25.0 50.0 25.0 25.0 20.0 MCA w/o Aux Fan 29.2 55.2 33.9 33.9 23.7 MCA w/aux Fan 29.2 60.2 36.1 36.1 25.7 MODEL 636 Compressor Motor RLA 13.5 3.5 7.8 4.4 4.4 2.9 20kW, Amps (Actual kw) 53.3 (20.1) 26.0 (21.6) 53.3 (20.6) 31.2 (22.4) 29.3 (18.8) 21.7 (21.6) 15kW, Amps (Actual kw) 37.8 (13.8) 18.5 (15.4) 37.3 (13.8) 22.5 (14.9) 24.9 (15.6) 15.5 (15.4) 10kW, Amps (Actual kw) 26.0 (10.3) 13.0 (10.8) 26.0 (10.3) 16.0 (11.2) 14.7 (9.4) 10.8 (10.8) w/o Auxiliary Fan 35.1 14.1 28.3 15.3 15.3 11.8 w/auxiliary Fan 40.8 16.6 33.3 17.5 17.5 13.8 MCA w/o Aux Fan 48.6 21.9 41.4 22.1 22.1 17.9 MOP w/o Aux Fan 60.0 25.0 45.0 25.0 25.0 20.0 MCA w/aux Fan 54.3 21.9 46.4 24.3 24.3 19.9 MOP w/aux Fan 60.0 25.0 50.0 25.0 25.0 20.0 MCA w/o Aux Fan 29.2 55.2 34.4 3 23.7 MCA w/aux Fan 29.2 60.2 36.4 36.4 25.7

600 Series Electrical Data MODEL 648 Compressor Motor RLA 8.3 5.1 6.1 5.1 5.1 3.3 20kW, Amps (Actual kw) 53.3 (20.1) 26.0 (21.6) 53.3 (20.6) 31.2 (22.4) 29.3 (18.8) 21.7 (21.6) 15kW, Amps (Actual kw) 37.8 (13.8) 18.5 (15.4) 37.3 (13.8) 22.5 (14.9) 24.9 (15.6) 15.5 (15.4) 10kW, Amps (Actual kw) 26.0 (10.3) 13.0 (10.8) 26.0 (10.3) 16.0 (11.2) 14.7 (9.4) 10.8 (10.8) w/o Auxiliary Fan 34.8 17.3 19.5 16.7 16.7 12.6 w/auxiliary Fan 40.5 19.8 24.5 18.9 18.9 14.6 MCA w/o Aux Fan 36.9 21.2 41.4 22.1 22.1 17.9 MOP w/o Aux Fan 50.0 25.0 45.0 25.0 25.0 20.0 MCA w/aux Fan 42.6 23.7 46.4 24.3 24.3 19.9 MOP w/aux Fan 60.0 25.0 50.0 25.0 25.0 20.0 MCA w/o Aux Fan 29.2 55.2 34.4 3 23.7 MCA w/aux Fan 29.2 60.2 36.4 36.4 25.7 MODEL 660 Evaporator Fan Motor FLA 5.7 2.5 5.0 2.2 2.2 2.0 Condenser Motor FLA 11.0 3.1 6.2 2.8 2.8 2.5 Compressor Motor RLA 15.4 6.0 11.5 5.1 5.1 4.3 20kW, Amps (Actual kw) 53.3 (20.1) 26.0 (21.6) 53.3 (20.6) 31.2 (22.4) 29.3 (18.8) 21.7 (21.6) 15kW, Amps (Actual kw) 37.8 (13.8) 18.5 (15.4) 37.3 (13.8) 22.5 (14.9) 24.9 (15.6) 15.5 (15.4) 10kW, Amps (Actual kw) 26.0 (10.3) 13.0 (10.8) 26.0 (10.3) 16.0 (11.2) 14.7 (9.4) 10.8 (10.8) w/o Auxiliary Fan 47.5 19.1 35.7 16.7 16.7 14.6 w/auxiliary Fan 53.2 21.6 40.7 18.9 18.9 16.6 MCA w/o Aux Fan 52.9 21.2 41.4 22.1 22.1 17.9 MOP w/o Aux Fan 70.0 25.0 50.0 25.0 25.0 20.0 MCA w/aux Fan 58.6 23.7 46.4 24.3 24.3 19.9 MOP w/aux Fan 80.0 25.0 50.0 25.0 25.0 25.0 MCA w/o Aux Fan 28.2 55.2 34.4 34.4 23.7 MCA w/aux Fan 30.7 60.2 36.6 36.6 25.7 MOP w/aux Fan 35.0 70.0 40.0 40.0 30.0 MCA w/o Aux Fan 37.5 74.6 39.6 39.6 31.5 MCA w/aux Fan 40.0 79.6 41.8 41.8 33.5 MOP w/aux Fan 50.0 80.0 50.0 50.0 35.0