Key Features and Benefits

Similar documents
BCPro System Product Bulletin

Satchwell MicroNet. Building Management System MicroNet 50 Series

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre

The Simply Smart Way to Optimize Building Control and Performance

Control systems. Efficient room control

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory

Discussion Topics. Integrated System Definition. Two Primary Characteristics. Understanding and Specifying Open Protocol Syracuse, NY April 2009

Andover ContinuumTM. Family of Controllers. BACnetTM

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

Supervisory Controllers

Sir Walter Scott may not have been thinking of building automation systems. How BACnet. Is Connecting At ASHRAE s Headquarters

System Controls Suggested Specification

The Scalable Building Management System

Trane Controls. Smart Solutions for Smart Buildings

Andover ContinuumTM. b3850 Series Terminal Controllers

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Wall-Mounted Air Conditioners with PLC Technology. Let Logic Control The Flow

Leveraging Building Automation Systems to support ongoing commissioning

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

TALON Network Manager- 2 & 6 Express

Building Energy Management Training Systems

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

Ethernet Networking The evolution of your building

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Data Center Infrastructure Management (D.C.I.M.)

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

30 top tips to tackle HVAC challenges No.15 - BACnet

Fall 2015 Release: Now Shipping!

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Everything you need to monitor and control your building

KMC Product Overview

BACnet. b3867 Terminal Controllers

Product Overview. KMC Controls Building Geniuses since Learn more about our entire product line at: KMCControls.com

Carrier Hong Kong Limited. Carrier Comfort Network. - optimizes the performance of HVAC Systems & is the premier solution for Building Control

Simplifying Device and System Integration Specifications for Building Automation Systems

Commercial Controls. Advanced control for saving time and money

Room Automation Solutions. Freeing up space in building automation.

Presented By: Tim McLaughlin, Director of Business Development - Engnuity and Richard Theron, Product Manager FieldServer Agenda: Introduction Who is

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

The Bard BrightStat Room Controllers

Automation Monitoring Control. EDN 2010 Hot 100

Built-in features Built-in simplicity Built for fans & pumps

Mr. Ed Merwin. Tridium

Underfloor Controllers

BACnet. b3810 Series Local Controllers

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Siemens BACnet VAV Actuator

Overview. Applications. Features

AUTOMATION. NETx BMS Server 2.0

Rochester Institute of Technology Control Best Practices

Transformative Wave Technologies Kent, Washington

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

ADAM-6000 Series. Features. The Path to Seamless Integration. Why Smart I/O? Why Web I/O? Control Strategy Moves to Field Devices. Why Mixed I/O?

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

BUILDING AUTOMATION YORKLAND

Comprehensive Data Center Energy Management Solutions

75F Smart VAV with Reheat

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Pow-R-Command System Overview

Delivered the Way Yo u Want

BACnet Controller for General-purpose Building Applications

Efficient. Innovative. Sustainable.

INTELLIGENT SOLUTION MANAGING AUTOMATION

J-201 Resource Capacity Guidelines and Sample Application Analysis

Metasys System Extended Architecture

SEZ7000 Series. Wireless Commercial Zoning System

Wireless Metasys System

Building Technologies. Desigo RXC Room automation system System description. Version 5 and later

TC Modular Series for BACnet Networks

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Smart Equipment Controls (SEC)

Building Control GAMMA instabus

Andover ContinuumTM Infinet II

The BACnet history He has a real problem...

Siemens BACnet Programmable TEC Unit Conditioner Controller

Andover ContinuumTM Infinet II

VZ7000 Series. BACnet Commercial Zoning System

UCOS User-Configurable Open System

Saia PCD1.Room is for applications in the field of room automation and HeaVAC. PCD1.M2110R1 with Ethernet TCP/IP for room automation applications

1.5 PCD1 modular, expandable, compact CPU

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Now available to pre-order from Distech Controls

Marketing Guide Tracer Summit WebOPS Version 1.2

LDALI ME204-U, LDALI ME201 U

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Modicon programmable logic and automation controllers

You wanted it...you ve got it.

Building Management System Application Datasheet

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

the HVAC controller range for OEMs siemens.com/buildingtechnologies-oem

FCU-4 FAN COIL CONTROLLER

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

Building Management Solutions. for Data Centers and Mission Critical Facilities

LDALI ME204-U, LDALI ME201 U

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

Transcription:

System Description Since its beginning, Automated Logic has focused on one objective: to develop innovative building automation systems with the latest technologies, which advance operational freedom, flexibility and ease of use. With the introduction of the Internet, the capabilities for building control combining our technologies with a global communications platform reached new levels: Ability to access information and control buildings from anywhere Ability to access information with a variety of devices, from desktop PCs to web-enabled cell phones Elimination of multiple databases, minimizing management needs These capabilities are yours with WebCTRL, Automated Logic s webbased building automation system. Unlike other systems merely adapted to the web, WebCTRL adopted emerging web technologies, creating the industry s most open, integrated and full-featured system. Yet building automation is just part of the story. Combined with its reporting, trending and scheduling capabilities, WebCTRL can help you better analyze your energy consumption, develop more effective conservation strategies and ultimately save on your operating costs. WebCTRL supports major communications protocols including BACnet, LonWorks, MODBUS and SNMP. With its ability to run on Java2-compliant server platforms such as Windows, Linux and Sun Solaris, WebCTRL can operate with many JDBC-compliant databases including Access, SQL and Oracle. And since it supports XML/SOAP, WebCTRL can easily share data with enterprise or thirdparty software to accomplish a range of tasks including: Generation of bills for tenants off-hours usage Automatic generation of building systems maintenance work orders Real-time usage pricing and/or system operating responses With these capabilities and more, you ve never had such potential to configure, network and manage building control systems in ways that best serve your operating needs and budget.

WebCTRL not only saves energy -it saves on expenses. Unlike other systems that require costly custom programming and are more difficult to use, our energy-saving features are fully integrated at installation. Features like: Setpoint Optimization - calculates optimum setpoint values based on actual operating requirements Optimum Start - assures comfortable settings at time of occupancy based on building conditions and system capacity Demand Reduction - reduces energy use on a short-term basis in response to utility pricing, billing criteria, regional consumption, etc. These energy-saving functions are combined with a wealth of other standard operating features, some of which include: Thermographic Color Floor Plans - convey a quick understanding of facility-wide comfort and operating conditions Hierarchical and Group Scheduling - supports customized, graphically displayed schedules for building, floors, zones or equipment groups to flexibly manage energy use Trending - enables operators to track and troubleshoot building conditions Logging/Reporting extracts and formats operating data from a browser to Acrobat, Excel and other applications with a single click Logical Alarming generates alarms and notifies users following a specified sequence of events

System Components: WebCTRL Software and User interface Automated Logic s WebCTRL is a building automation system that offers an intuitive user interface and powerful control features. Your building can be accessed from anywhere in the world using a standard web browser, eliminating the need for special software on the workstation. Through a browser you can access all building management functions including: Setting and changing schedules, Adjusting setpoints and other control properties, Graphically trending important building conditions, Viewing and acknowledging alarms, and Running preconfigured and custom reports on energy usage, occupant overrides, tenant billing, and much more. Developed entirely around proven open standards and web technologies, WebCTRL s server software runs on a variety of major platforms, including Windows, Sun Solaris and Linux. Major databases are supported by the server, such as MS SQL Express, MS SQL Server, PostgreSQL and Oracle. Intuitive, comprehensive building operation with dynamic, interactive graphical access Completely designed around open standards Uses the language of the web (HTTP) to communicate over the Internet or intranet without special software or plug-ins Runs on multiple platforms including Windows, Linux, and Sun Solaris Advanced alarm management capabilities including email, pagers, network printers, etc. Uses sophisticated alarm escalation system protection with multi-level passwords and Secure Sockets Layer with 128-bit encryption for security Monitors and controls a wide variety of third party HV-ac and electrical equipment through a browser Fully compatible with legacy ALC Systems

LGR line High Speed Ethernet Router The LGR is an extremely powerful, high-speed router/gateway that can connect hundreds of control modules to a BACnet /IP backbone. Support for BACnet/IP, BACnet-over- Ethernet, ARCNET 156 Kbps, MS/TP, and BACnet PTP communications are standard. A wide range of open and proprietary protocol translator drivers allow the LGR to also serve as a gateway to other manufacturers equipment. Fully programmable, the LGR can also execute complex control strategies for high-level system integration. 10/100Base-T Fast Ethernet allows modules to serve as a BACnet router between BACnet/IP system backbone and field devices subnetwork. Native BACnet communications to field devices over a high-speed ARCNET 156 Kbps or BACnet MS/TP network. Can route messages from BACnet/IP to BACnet-over-Ethernet, providing compatibility with older BACnet systems. A wide range of open and proprietary protocol translator drivers allow the LGR to also serve as a gateway to other manufacturers equipment. Designed with a high-speed true 32-bit microprocessor with cache memory, Fast Ethernet controller, high performance 32-bit serial communications co-processor, and ARCNET communications co-processor, LGR routers have the horsepower to serve the most demanding translation and communications functions. 16 MByte battery-backed SDRAM (32 bit wide), with 12 MBytes available for use, stores application programs, trends and other data when power is lost. 8 MByte Flash memory (32 bit wide) for easy field upgrades over the network. Battery backed real-time clock provides true standalone capabilities. LGRs recover from power failures providing full continuity of operations, even when communications are disrupted.

ME line Powerful Multi-Equipment Controller ME controllers have the speed, power, memory, and I/O flexibility to handle the most demanding control applications in the industry. Capable of controlling multiple pieces of equipment simultaneously, these robust BACnet controllers can support complex control strategies with plenty of memory for trends and schedules. Battery backed RAM and a real-time clock make these controllers ideal for critical applications, where the ability to recover from power outages and network interruptions is crucial. Multi-equipment capabilities support general HV-ac applications including complex central plants. Native BACnet communications to field devices over a high-speed ARCNET 156 Kbps or BACnet MS/TP network. Controller units include an expansion port for MEx I/O expanders or previous generation MX expanders. Up to six MEx expanders can be mounted in a stack or remotely mounted for scalable control solutions. Designed with a high-speed true 32-bit micro-processor with cache memory, high performance 32-bit serial communications co-processor, ARCNET communications coprocessor and CAN (Control Area Network) co-processor, ME controllers have the horsepower to serve the most demanding control applications. 16 MByte battery-backed SDRAM (32 bit wide), with 12 MBytes available for use, stores application programs, trends and other data when power is lost. 8 MByte Flash memory (32 bit wide) for easy field upgrades over the network. Battery backed real-time clock provides true standalone capabilities. Control modules recover from power failures providing full continuity of operations, even when communications are disrupted.

SE6166 /SE6104 Rugged Flexibility for Single Equipment Applications Automated Logic s powerful SE line provides a rugged solution for single equipment applications. Designed to operate in a wide range of environmental conditions, SE controllers can be used in rooftop units, mechanical rooms, equipment closets, or almost any other weather tight location. Fully programmable using the EIKON -LogicBuilder graphic programming language, SE controllers use native BACnet communications over either a high-speed ARCNET 156 Kbps network or a medium speed MS/TP network to provide maximum flexibility and interoperability. Native BACnet communications to field devices over a high-speed ARCNET 156 Kbps or BACnet MS/TP network. 12-bit Analog to Digital converter provides extreme precision on all inputs. Pulse counting capability up to 40 Hz is available on selected inputs. Uses a high-speed microprocessor with 1 MByte Flash memory and 1 MByte of RAM for unparalleled programmability. Firmware upgrades can be downloaded remotely no chip replacement necessary. Battery backed real-time clock provides true stand-alone capabilities. Control modules recover from power failures providing full continuity of scheduled operations, even when communications are disrupted.

ZN341v+/ZN141v+ VAV Controller Automated Logic s ZN341v+/ZN141v+ are designed for a variety of pressureindependent VAV applications. These advanced controllers feature an integral actuator, advanced precision air-flow sensor, flexible connectivity to the full line of RS sensors, and easy-to-use air balance routines. Sophisticated pre-engineered control algorithms reduce energy consumption, maximize actuator life, and ensure occupant comfort. The ZN series controllers are fully programmable and provide networked peer-to-peer communications using native BACnet-over-ARCNET 156 Kbps or MS/TP. Optimized design for all types of pressure independent VAV applications including cooling only, cooling with modulated hot water re-heat, cooling with electric re-heat, constant volume boxes and dual duct boxes. Uses a high speed 16-bit microprocessor with 1 MByte Flash memory and 512 KByte of RAM for graphical programming, diagnostic trends, and easy firmware upgrades using remote downloading - no chip replacement necessary. Built-in 0-10 V-dc AO for baseboard or re-heat valve actuator. Compact and rugged design for easy mounting and an integral brushless actuator for reliability and longevity. The combination of the precision air flow sensor and advanced VAV algorithm assures occupant comfort both at minimum and maximum design air flows, while maximizing actuator life. Compatible with the ZASF integral air flow sensor/actuator assembly for dual duct applications. Rnet port supports Automated Logic s line of RS room sensors and provides local access to the system.

ZN551 Zone Controller Automated Logic s ZN551 provides unprecedented power and flexibility through fully programmable networked controllers. The ZN551 controllers connect to the Building Automation System (BAS) network using BACnet over ARCNET 156 Kbps or MS/TP. The ZN551 supports a line of RS room sensors using Rnet port. Powerful zone controller for VAV, heat pump, unit ventilator and other packaged HVac applications. Native BACnet communications to field devices over a high speed ARCNET 156 Kbps or BACnet MS/TP network. Uses a high speed 16-bit microprocessor with 1 MByte Flash memory and 512 KByte of RAM for unparalleled programmability. Firmware upgrades can be downloaded remotely no chip replacement necessary. The ZN551 is part of a full line of ZN controllers which include a variety of Universal Inputs, Binary Outputs and 0-10V-dc Analog Outputs. Other ZN models with built-in flow sensors and/or integral damper actuators are available as well as optional single/dual air flow sensors for pressure independent VAV applications. An extensive library of pre-engineered control routines provides proven solutions for most zone control applications. Custom programs can be easily written in EIKON - LogicBuilder, ALC s legendary graphic programming language.

Third Party Integration This list of manufacturers shows just some of the equipment to which we re connected. WebCTRL 's open architecture and support for industry standards makes integration with third party mechanical and electrical building sub-systems easy. The WebCTRL system is capable of supporting multiple protocols over a TCP/IP network allowing many equipment items to be connected directly to the main WebCTRL backbone. Equipment using BACnet can be connected to an IP, ARCNET, MS/TP, or Point to Point (PTP) network segment. Automated Logic's Open Systems Integration allows for seamless interconnection to equipment using BACnet, Modbus, N2, JBUS, or LonWorks, as well as an extensive list of proprietary protocols. Automated Logic continually develops innovative third party integration solutions to add to our Integration resume. Contact your local Automated Logic dealer for a current listing of integration applications or to discuss your custom integration requirements