INSTALLATION MANUAL. ST-PTZIR480-22X High-Speed Intelligent Dome IR PTZ Color Camera. Copyright North American Cable Equipment, Inc.

Similar documents
ST-PTZ High-Speed Intelligent Dome PTZ Color Camera

Professional Pan Tilt Zoom Camera ST-HD-PTZ-2MP INSTALLATION MANUAL

INSTALLATION MANUAL. ST-BT1000IR2812-G Varifocal IR Bullet Camera. v1.0 8/4/14 1

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

ST-HD-TD W Varifocal IR Color HD-CVI Camera

Camera Installation Manual Ver 1.0. Pan, Tilt and Zoom Dome Camera / PTZ

Supplied Accessories.

Supplied Accessories.

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

HuddleCamHD 10X-USB2

FastCam Outdoor Speed Dome Camera

INSTRUCTION MANUAL Ver 3.0. Indoor Pan, Tilt and Zoom Dome Camera / ACD-1000-LG27

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

SDI Speed Dome Camera OSD Menu

Iris Innovations. IM-PTZ-16 Micro-PTZ Camera. Iris Innovations

HDC-SDOMEO51MIR-B USER MANUAL. HD Portable Rugged PTZ Cameras

DS-2AF7264/7268-AW. High Definition IR Wiper PTZ Dome Camera

Weatherproof IR Color Day/Night Cameras

Avonic AV-CON300. PTZ Camera Controller

ALI-TP4013R 3MP HD-TVI 130 IR Outdoor Bullet Camera Quick Installation Guide

195Z. 321Z_Manual_V0.82

DS-2AF7023I. H Series IR Analog PTZ Dome Camera

HuddleCamHD 3x USB 2.0 PTZ CAMERA INSTALLATION & OPERATION MANUAL

CM55-VCU USB 3.0 HD PTZ Camera User Manual v2.1

IR Varifocal IP66 Weatherproof Cameras

SERVICE MANUAL 1/3 SONY DSP COLOR CCD CAMERA OVER 650TVL SERIES

HuddleCamHD 3XA with Audio USB 2.0 PTZ Camera w/ built-in Mic Array Installation and Operation Manual

CM-Z2212GY. Outdoor IR Speed Dome PTZ Camera

SPD hour All-Round Surveillance PTZ (25X) High Speed Color Dome Camera

Installation and Operation Manual for High Speed Dome Camera

ALI-TP3013R 3MP HD-TVI Outdoor Bullet Camera Quick Installation Guide

SERVICE MANUAL 1/3 SONY DSP COLOR CCD CAMERA 600TVL O.S.D. WDR SERIES

ALI-TS1013R HD-TVI 3MP Mini-Turret Camera Quick Installation Guide

HD-SDI Indoor Dome Camera

DANNOVO HD USB 3.0 PTZ Video Conference Camera User Manual

Wide Dynamic Range Dome Camera WDR-D3

Speed Dome. Technical Manual

NEXPTZ364P(N)A HIGH-SPEED EXPLOSION-PROOF PTZ FEATURES.

ALI-TS3025R 5MP HD-TVI 265 ft IR Outdoor Bullet Camera Quick Installation Guide

ST-HDC2FD QUICK START GUIDE. Or contact technical

Please refer to the table below for the features of individual camera models.

HTINTD8 (2.8~12mm) HTINTD9 (5.0~50mm) HTINTD10 (9.0~22mm)

Infrared Dome CCD Camera User Manual

Low-Light Color High Speed Dome Camera

Speed Dome Camera User Manual

EPTZ9200 / EPTZ9200i Speed Dome Camera

Analog Speed Dome. New 1/4 Sensor. Privacy Masking. Multi-Protocol Telemetry. IP66 Protection. Designed For Constant Use.

Owner s Manual Motorized Dome Cameras

GV-SD2322-IR (22x) Outdoor Low Lux IR IP Speed Dome

PTZ10INTW INTERNAL PAN, TILT AND ZOOM DOME CAMERA USER MANUAL

ALI-TS4015R 5MP HD-TVI 135 ft IR Varifocal Outdoor Bullet Camera Quick Installation Guide

DS-2AF5023. H Series 5 Inch Analog PTZ Dome Camera

VZ-TVI-B3040MZVF 3MP Motorized VF EXIR Bullet Camera

Model: PTZWP12X. (Indoor / Outdoor Use) 12X Speed Dome Operation Manual

DS-2DF1-614X/604X Network Speed Dome. Technical Manual

AUTO TRACKING HIGH SPEED DOME CAMERA User s Manual

PTZPZ9 Intelligent Integrated IR High Speed Dome Installation Manual Version

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

PL Colour CCD Camera. 1,Features. Features: 1),Unique. 2) Other Feature:s: CCTV System Solutions

User s Manual for ZKSD4 Series Mini PTZ

D/N VANDAL RESISTANT ATR 700TVL VARI-FOCAL DOME CAMERA CMD6182X/6186X3.6 N/P

VITEK VTD-IR2811DN FEATURES: 1/3 Color CCD with 560 TV of Lines Resolution (600 TV Lines in B/W mode)

Installation and Operation Manual for High Speed Dome Camera

SECTION 1 GENERAL DESCRIPTION

Mini Speed Dome Camera

HuddleCamHD 30x USB 3.0 PTZ CAMERA INSTALLATION & OPERATION MANUAL

PTZ Conference Room USB Camera

Color Speed Dome Camera. Manual

Speed Dome. Technical Manual

GV-SD3732-IR (33x) 3 MP H.265 Low Lux WDR Pro Outdoor IR IP Speed Dome

Analog High Definition Micro Dome Camera

Quick Start Guide. Thank you for purchasing our products. Please read the cut-sheet carefully before operating. Safety Precaution

SVEX-W125 EXPLOSION PROOF CAMERA FEATURES: FEATURES:

DS-2DF1-512NS Series

HDVCPTZ TRUE HD 720P PAN, TILT & ZOOM CCTV CAMERA

High Speed in-ceiling and Outdoor PTZ Dome Cameras with multi-protocol capabilities

Contents. 1 Notes Product Introduction Product Structure

Avonic CM-CON100. PTZ Camera Keyboard Controller

Starlight V1363TIR. User Manual Version #2: Camera with ICON Menu

USER MANUAL. 1080P Eco - 4 in 1 Series

VCC-P9574S VDC-DP9584S. Pan-Focus PTZ Dome Cameras. Built-in X2.6 Motorized Zoom Pan-Focus Lens

High Resolution Bullet Camera

TURBO HD D7T Series Dome Camera

HDCAM-5090 HIGH SPEED DOME CAMERA USER S MANUAL

SVD-4120A SSNR Low Light, WDR, Day & Night Vandal-Proof Color Dome Camera

SPD High Speed Color Dome Camera

CAM-7B-21IR-WDR Weatherproof IR Color Camera

dome camera. Image Inverse feature

WARRANTY CARD. [Document subtitle] [DATE] LENOVO [Company address]

VITEK VTD-THD2RFE VTC-THT2RFE VTC-THB2RFE. 2.1 Megapixel Indoor/Outdoor HD-TVI/ AHD/CVI/CVBS IR Cameras

HD SDI 1080P ICR OSD 42 IR Vandal Dome Camera

KTC-XP1 UltraView Camera With Xposure Technology

Marshall Electronics VS-WM202-HDSDI. User Manual. Heavy Duty Exterior PTZ Camera 20x Zoom and IR LED

VITEK VTC-C680 VTC-C750. 1/3 Color Camera Series. 1/3" Super HAD CCD With 550 TVL (VTC-C750 / VTC- C750DN) & 480 TVL (VTC-C680 / VTC-C680DN)

Vandal Dome Camera. DWC-V362D DWC-V362DIR User Manual ABOUT MANUAL

CMOS HD Digital Camera User's Manual

Instruction Manual. DW5V9TVB, DW5V9TVB-1 5 Outdoor Dome With True Day/Night Gen III IR Filter Retraction

PIXIM Micro Dome Camera

SSC-CD SERIES Fixed Mini-dome Cameras SSC-CD45P SSC-CD49P SSC-CD75P SSC-CD77P.

HD-TVI 1080P (2MP) Outdoor IR PTZ Dome Camera w/ 30 Optical Zoom

Transcription:

INSTALLATION MANUAL ST-PTZIR480-22X High-Speed Intelligent Dome IR PTZ Color Camera Copyright North American Cable Equipment, Inc.

PACKAGE CONTENTS This package contains: One ST-PTZIR480-22X high-speed intelligent dome color camera. One mounting bracket. One 24VAC 3A power supply. One installation manual. PRODUCT DESCRIPTION The ST-PTZIR480-22X is a professional grade infrared intelligent dome color camera with pan, tilt and zoom (PTZ) capability and 480TVL resolution. The camera s non-volatile digital memory allows the saving of all settings. Its 200 preset positions provide versatility for cruise routes and tour functions. The ST-PTZIR480-22X s mechanical design permits continuous horizontal 360 rotation and 90 vertical flip. Temperature management is built-in. Functions and Features Non-volatile design ensures data will not be lost if power fails. Recovery function allows the camera to continue previous functions after power is restored. Support for 200 presets and 4 preset tours, each containing up to 32 presets. 4 patterns, each can be recorded for 1000 discrete PTZ controller moves. Support for 4-auto scans. Soft and hard ID settings can be edited on the DIP switch or via the OSD menu. Integrated multi-protocol control: PELCO P, PELCO D. 2 ch alarm input; 2 ch alarm relay output. Proportional zoom lens; P/T speed will decrease in proportion with depth of zoom. Can be installed indoors or outdoors. Horizontal pan speed 0.5º-82º/s. Vertical tilt speed 0.5º-30º/s. 360º continuously horizontal rotation. Complies with IP 66/CE standard. Built-in surge protection circuitry. Auto focus, manual priority. Auto iris. Auto shift from Color to B/W. Built-in OSD makes it easy to configure all settings of the camera. Built-in display for the internal dome temperature, preset status and compass direction. 330ft IR distance for long-range surveillance.

SPECIFICATIONS ST-PTZIR480-22X Specifications (Typical) 1. Image Sensor Samsung SDM-270 with ¼ SONY CCD 2. Resolution 480TVL 3. Lens Auto Iris; F=3.5 to 94.5mm; 22X Optical Zoom, 10X Digital Zoom 4. Illumination 0.1 Lux 5. Pan Range 360º continuous 6. Tilt Rotation Range 0º - 90º flip 7. Manual Speed Pan 0.1º - 82º/sec 8. Manual Speed Tilt 0.1º - 30º/sec 9. Preset Speed 82º/sec 10. Preset Accuracy ±0.10 11. Preset Positions 200 12. Function Display Yes 14. Pan & Tilt Position Display Yes 15. MAX IR Distance 330ft 19. Patterns 4 programmable (pan/tilt/zoom and each tour is 120 seconds) 20. Sequences (Tours) 4 programmable (dwell time speed preset point) 21. Protocol Pelco-D, Pelco-P selectable 22. Auto Scan With programmable variable speed 23. High Efficient 3-Dimension Scan Yes 24. Long-Focus Speed Limited Yes 26. Home Position Yes 27. Camera Menu Operation Yes 28. IP66 for Outdoor Use Yes 29. Operating Humidity 95% 30. Heater Operation 42ºF on; 57ºF off 31. Operating Temperature -40ºF - 122ºF 32. Video Connection BNC coaxial 33. Power 24VAC @3A, 35W 34. Communication RS485

Dimensions 4 1/8 4 1/8 6 1/8 3 ¾ 5 ½ 6 10 1/8 Wall Mount Dimension 7 ¾ 6 5 ¼ 5 ½ 6 ½ Picture 2

INSTALLATION AND OPERATION This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions. This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock. CAUTION: To reduce the risk of electrical shock do not remove the cover or back of this unit. No user serviceable parts are inside. CAUTION: To prevent electric shocks and risk of fire hazards, do not use other than specified power source. 1. UNPACKING and HANDLING Each unit is shipped partially assembled factory tested. Ensure that all accessories are removed from the container before discarding packing materials. a. Use the mounting arm as a template to mark the holes for your mounting hardware.

b. Feed the cable assembly up through the smaller end of the mount and out the rear opening. c. Assemble the camera dome to the mounting arm using the 4 supplied allen-head cap screws and allen wrench. 2. MECHANICAL INSPECTION Inspect the entire camera for shipping damage. Make sure the equipment is clean, and no connectors are broken, damaged, or loose. If equipment appears to be damaged or defective please contact your distributor or SecurityTronix at 1-610-429-1511 for assistance. 3. SPECIAL ATTENTION a. The installer must comply with electrical safety standards. There must be sufficient space between the camera s power supply and video line and any high voltage equipment and/or cables. b. To help ensure the camera s life and proper operation do not point the camera towards the sun or strong light. c. Do not install the camera in an environment where the temperature is above 122 F. d. Do not install the camera near a magnetic field or a high-power motor. e. Do not mount the camera near a radiator or heater. f. The installation site and material must fully support the weight of the product. g. Only use a dry cloth to clean the camera. If there is dirt that is difficult to remove wipe gently with a mild detergent. Never use strong or abrasive detergents. h. The included 24VAC at 3A power supply must be used. Using a DC or other incorrect power supply will damage the camera. i. Only qualified installers are allowed to install, test and disassemble the camera. j. The camera is a low voltage product. If installed outdoors proper safety and lightning grounding are required. k. Before installing be sure the grounding, wiring, input power, voltage, DIP switches, communication protocol and baud rate are correctly set prior to powering up and using.

4. CAMERA SETUP BAUD RATE & PROTOCOL SETUP DIP Switch Settings Baud rate Setting SW2(B7~B8) Protocol Setting SW2(B1~B2)

DOME ADDRESS SETUP System Setup DIP Switch SW1 ON = 1 OFF = 0

9

5. WIRING CONNECTIONS 6. FUNCTIONS and OPERATION Menu Operation Several functions can be accessed directly without using the camera s on screen menu display. Note the following dedicated preset functions: Special Use Preset Numbers Call PRESET 95 Enter into main OSD menu Call PRESET 96 Run pattern 1 Call PRESET 97 Run Sequence 1 Call PRESET 92 Set Left limit point for L/R scan Call PRESET 93 Set Right limit point for L/R scan Call PRESET 99 Run Left-right scan NOTE: If Left limit point and Right limit point are set to the same position, calling preset 99 will execute a 360 scan. Call PRESET 33 Swing 180 Call PRESET 34 Return to Zero point The on screen menu provides access to all camera functions through the use of a standard RS485 connection and PTZ controller. As shown above, use the PTZ controller to CALL PRESET 95 and the camera s OSD menu will appear overlaid upon the video output of the camera, as shown below. 10

Menu Guide MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PAN TILT ` SETTING DISPLAY ` SYSTEM SETTING DOME ID TITLE LANGUAGE SELECT CHANGE PASSWORD FACTORY DEFAULT SYSTEM RESTART SYSTEM INFOMATION CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE BACKLIGHT MODE PANTILT SETTING PAN TILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP HOME ACTION DISPLAY CONFIGURATION DOME TITLE : OFF PRESETS TITLE : OFF ZOOM POSITION : OFF DIRECTION INDICATOR : OFF ENVIRONMNT INDICATORS OFF ALARMS SETUP INPUT CHANNEL : 001 ALARM ACTION : DISARM INPUT MODE : NO ALARM LINKAGE : OFF RELAY OUTPUT : OFF RESET DELAY : 30 11

Main Menu Function Setting Main menu SYSTEM SETTING CAMERA PARAMETERS PAN TILT SETTING DISPLAY System Setting MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PAN TILT SETTING DISPLAY CONFIGURATION SYSTEM SETTING DOME ID : 001 TITLE LANGUAGE SELECT: ENGLISH CHANGE PASSWORD FACTORY DEFAULT SYSTEM RESTART DOME ID The camera supports both hard addressing and soft addressing. Hard addressing is achieved by setting the address DIP switches to the desired address. When this is done, soft addressing is disabled. When all address DIP switches are set to OFF, the soft-addressing option becomes available in the OSD menu. Procedure: 1. Set all ADDRESS DIP switches to zero (off). 2. Call preset 95 to enter the main menu. 3. Using the up & down PTZ controls, choose [SYSTEM SETTING] and press [OPEN] to confirm and enter the system setting menu. 4. Under [SYSTEM SETTING] choose [DOME ID] and press [OPEN] to confirm. 5. Using the up/down and left/right PTZ controls, enter the 12 character serial number shown at the top of the menu and press [OPEN] to move to the next menu. 6. Enter the new dome ID# and press [OPEN]. The menu will show the new dome ID and prompt to press [OPEN] to accept. 7. Set your PTZ controller to the dome s new address and press [OPEN]. TITLE SETTING: 1. Call preset 95 to enter the main menu. 2. Using the up/down cursor, choose [SYSTEM SETTING]. Press [OPEN] to confirm the selection. 3. Under [SYSTEM SETTING], choose [TITLE] and press [OPEN] to confirm the selection. 4. Use up/down to choose letters and numbers for the name, and L/R to navigate to the next character of the name. 5. When the name is complete, press [OPEN] to save and exit the title menu. Press [CLOSE] to exit without saving. 12

Notes: 20 characters can be set. Characters include: 0-9 A-Z :<>-. Other text-entry menus follow this same procedure. LANGUAGE SELECT 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [SYSTEM SETTING] and press [OPEN] to confirm the selection. 3. Under [SYSTEM SETTING] choose [LANGUAGE SELECT] and Press [OPEN] to confirm the selection. The language will be flashing. 4. Use up/down to choose a language. 5. Press [OPEN] to save and exit this menu item; Press the [CLOSE] key to exit immediately without saving. CHANGE PASSWORD 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [SYSTEM SETTING] and press [OPEN] to confirm the selection and enter the system setting menu. 3. Under [SYSTEM SETTING] choose [CHANGE PASSWORD] and press [OPEN] to confirm the selection. 4. Use the up/down controls to choose letters and numbers for the name, and L/R to navigate to the next character of the name. 5. When the name is complete, press [OPEN] to confirm. This will save and exit the title menu. Press [CLOSE] to exit without saving. 6. If there is already a password in place you will be prompted to enter it first. Input the old password and press the [OPEN] key. Input New Password will be shown on the screen. Input the new password, then re-enter it once more to confirm. Password Modification Succeed will be shown on the screen. 7. CAUTION: For security reasons, there is no way for users to bypass or reset the password settings. If a password is entered incorrectly or forgotten it will be impossible to access the camera s OSD menu. In order to regain access in the event of a lost or forgotten password, the camera must be re-initialized by the factory. Note: The factory-set original password is 000000. If you set the dome password as 000000, then no password will be required to access the camera. FACTORY DEFAULT 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [SYSTEM SETTING] and press [OPEN] to confirm the selection and enter the system setting menu. 3. Under [SYSTEM SETTING] choose [FACTORY DEFAULT] and press [OPEN] to reset the camera to the factory default settings. SYSTEM RESTART 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [SYSTEM SETTING] and press [OPEN] to enter the system setting menu. 3. Under [SYSTEM SETTING] choose [SYSTEM RESTART] and press [OPEN] to begin the reset. This process is the same as power-cycling the camera, so the camera will perform its startup function check. SYSTEM INFORMATON 13

Under [SYSTEM SETTING] choose [SYSTEM INFORMATION] and press [OPEN] to confirm the selection. The dome s present system information will be shown on the screen CAMERA PARAMETERS MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PAN TILT SETTING DISPLAY] CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE BACKLIGHT MODE LENS PARAMETER Use this menu to set the camera's zoom speed, electronic zoom, and focus and preset points limit. CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE LENS PARAMETER ZOOMING SPEED : HIGH DIGITAL ZOOM : ON FOCUS LIMIT : 30cm ZOOMING SPEED 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [CAMERA PARAMETERS] item, press [OPEN] to confirm the selection and enter [LENS PARAMETER] menu. 3. Under [LENS PARAMETER] choose [ZOOMING SPEED] item and press [OPEN] to confirm the selection and the parameter setting will blink. 4. Up/Down P/T to change the value. 5. Press [OPEN] to save and exit this item setting; Press [CLOSE] to exit immediately without saving. DIGITAL ZOOM SETTING 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [CAMERA PARAMETERS] and press [OPEN] to confirm the selection, then enter the [LENS PARAMETER] menu. 3. Under [LENS PARAMETER] choose [DIGITAL ZOOM] and press [OPEN] to confirm the selection and enter electronic zoom set. The setting will blink. 4. Up/Down P/T to choose ON or OFF. 5. Press [OPEN] to save and exit this item setting; Press [CLOSE] to exit immediately without saving. FOCUS LIMIT SETTING Use this to limit the focal distance of the camera in order to improve the performance of the lens focus. For example: With a minimum focus distance of 1 meter, the camera will not try to focus on dust, dirt, water etc. on the camera dome itself. 14

1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [CAMERA PARAMETERS] and press [OPEN] to confirm the selection, then enter [LENS PARAMETER] menu. 3. Under [LENS PARAMETER] choose [FOCUS LIMIT] and press [OPEN] to confirm the selection and enter focus limit set. The setting will blink. Use up/down P/T to change the setting. 4. Press [OPEN] to save and exit this item setting; Press [CLOSE] to exit immediately without saving. EXPOSURE MODE Use this menu to set exposure mode, shutter speed, aperture, gain, brightness, back light compensation, fast/slow shutter, exposure compensation, wide dynamic range and other parameters to maximize the camera s image quality. CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE EXPOSURE MODE EXPOSURE MODE : AUTO IRIS LEVEL : F5.6 SHUTTER SPEED : 1/60 AGC LEVEL : 0dB BRIGHT LEVEL : 016 DIGI-SLOW SHUTTER: AUTO Exposure Mode Setting 1. Call preset 95 to enter the main menu. 2. Use the up/down PTZ controls to choose [CAMERA PARAMETERS] and press [OPEN] to confirm the selection. 3. Under [CAMERA PARAMETERS] choose [EXPOSURE MODE] and press [OPEN] to confirm the selection which enters the exposure sub-menu set. 4. In the Exposure Mode menu choose the [EXPOSURE MODE] line item and press [OPEN] to confirm the selection and enter the exposure mode selection setting. EXPOSURE MODE: The 5 available choices are: 1) IRIS, 2) SHUTTER, 3) BRIGHT, 4) USER and 5) AUTO. When the exposure mode is set to AUTO, all exposure settings are handled by the camera automatically. This is the recommended setting, as several parameters are dynamically adjusted to obtain the best image output. When the exposure mode is set to USER the IRIS, SHUTTER, and BRIGHT parameters can be set manually to fixed values, which will all be used to control exposure. When the exposure mode is set to IRIS, then the exposure will be set by the iris level ONLY and the other values will be ignored. When the exposure mode is set to SHUTTER, then the exposure will be set by the shutter speed ONLY and the other values will be ignored. When the exposure mode is set to BRIGHT, then the exposure will be set by the bright level ONLY and the other values will be ignored. 15

AGC (Auto Gain Control): This is set individually. There are 16 settings from -3dB through 28dB. DIGI-SLOW SHUTTER: This can be turned either on or off. Turning this ON allows the camera to increase gain by slowing down the shutter digitally. DAY/NIGHT MODE: This can be set to either DAY, NIGHT or AUTO. The AUTO setting is recommended. In AUTO mode the camera will change back and forth from day to night mode automatically, turning the IR LEDs on or off as needed. The DAY setting manually turns off the IR LEDs and the camera will produce a color image. The NIGHT setting manually turns on the IR LEDs and the camera produces a black & white image. WHITE BALANCE MENU: Use this function to set various white balance modes, both auto and manual. The red gain and blue gain settings can also be set manually. CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE WHITE BALANCE White Balance Mode : AUTO Red Gain : 000 Green Gain : 000 WHITE BALANCE SETTING: 1. Call preset 95 to enter the main menu. 2. Choose [CAMERA PARAMETERS] and press [OPEN] to confirm the selection. 3. Choose [WHITE BALANCE] and press [OPEN] to confirm the selection and enter the white balance menu settings. 4. The [WHITE BALANCE] parameters can be set as bellow: [AUTO]: This is the default mode. White balance sensors automatically detect the environment to restore the true color. [USER]: The user manually adjusts Red Gain and Blue Gain values. [ATW]: Automatic tracking modes [OPW]: Single-lock mode [Outdoor]: Outdoor mode, colder colors [Indoor]: Indoor mode, warmer color 5. Use up/down to select the desired white balance mode. 6. Press [OPEN] to save and exit this item setting; Press [CLOSE] to exit immediately without saving. Attention: The Red Gain and Blue Gain values can only be changed when White Balance mode is set to USER. BACKLIGHT MODE SETTING 16

Use this setting to help compensate for lighting conditions where there is a strong light visible behind the object you are trying to observe with the camera. CAMERA PARAMETERS LENS PARAMETER EXPOSURE MODE WHITE BALANCE BACKLIGHT MODE BACK LIGHT MODE : ON BACKLIGHT MODE 1. Under [CAMERA PARAMETERS] choose [BACKLIGHT MODE] and press [OPEN] to enter BLC mode set. 2. Use up/down PT to choose ON or OFF. 3. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. PAN TILT SETTING MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PAN TILT SETTING DISPLAY CONFIGURATION PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP HOME ACTION PANTILT Set Menu PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP HOME ACTION PANTILT SET AUTO FLIP JOYSTICK RECOVER SPEED PROPORTIONAL INFRARED LIGHTING INFRARED ARRAY SET NORTH DIRECTION GOTO ZERO POSITON Auto-flip Auto-flip allows the camera to rotate 180 horizontally and upward 90 vertically after the tilt is positioned straight down. This allows the camera to operate as if it had 180 vertical tilt capability. 2. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu and press [OPEN] to confirm the selection. 3. Under [PANTILT SETTING] choose [AUTO FLIP] and press [OPEN] to confirm the selection 17

and enter auto flip set. 4. Use Up/down P/T to select and change this function to ON or OFF. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. JOYSTICK RECOVER ALL: When ALL is selected, both the focus and iris will return to automatic operation after any joystick command is received from the camera. NONE: When NONE is selected, the focus and iris will remain under manual control only. The camera will not attempt to auto-focus the camera or operate the iris automatically. FOCUS: When FOCUS is selected, just the focus function will return to automatic mode when the joystick is moved after a manual adjustment has been made. The iris will remain under manual control. IRIS: When IRIS is selected, just the iris function will return to automatic mode when the joystick is moved after a manual adjustment has been made. The focus will remain under manual control. 2. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu, press [OPEN] to confirm the selection and enter pan parameter set. 3. Under [PANTILT SETTING] choose the [JOYSTICK RECOVER] menu and press [OPEN] to confirm the selection. 4. Up/down P/T to change the setting. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. SPEED PROPORTIONAL This function causes the speed at which the camera pans to decrease proportionately with the amount of zoom applied; When the camera is zoomed out wide, it will pan at full speed. When the camera is zoomed in far, the camera will pan slower. 2. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu, press [OPEN] to confirm the selection and enter pan parameter set. 3. Under [PANTILT SETTING] choose the [SPEED PROPORTIONAL] menu and press [OPEN] to confirm the selection. 4. Up/down P/T to change the setting. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. INFRARED LIGHTING The IR LEDs can either be turned on manually or set to turn on and off automatically as lighting conditions change. 2. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu, press [OPEN] to confirm the selection and enter pan parameter set. 3. Under [PANTILT SETTING] choose the [INFRARED LIGHTING] menu and press [OPEN] to confirm the selection. 4. Up/down P/T to change the setting. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. INFRARED ARRAY 18

The IR LEDs can be set to switch from low power to high power when the zoom lens is zoomed to a certain amount. For example, setting this to 3X will change the LEDs to the higher power setting when the lens is zoomed to 3X optical magnification or more. 6. Call preset point 95 to enter the main menu. 7. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu, press [OPEN] to confirm the selection and enter pan parameter set. 8. Under [PANTILT SETTING] choose the [INFRARED ARRAY] menu and press [OPEN] to confirm the selection. 9. Up/down P/T to change the setting. 10. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. SET NORTH DIRECTION By using this function, the system will automatically save the current position of the dome camera as the north direction and it will be regarded as the zero point of direction, i.e. 0 level position.. 2. Under [PANTILT SETTING] choose the [PANTILT SETTING] menu, press [OPEN] to confirm the selection and enter pan parameter set. 3. Under [PANTILT SETTING] choose [SET NORTH DIRECTION] menu and press [OPEN] to confirm the selection and prepare to aim the camera. 4. Use the PTZ controller to aim the camera lens to the North. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. GOTO ZERO POSITON This function causes the camera to calibrate itself to a zero position which can be used to realign the camera to its original preset positions in the event of a physical misalignment or power failure. 2. Under [PANTILT SETTING] choose [PANTILT SETTING] and press [OPEN] to confirm the selection and enter pan parameter set. 3. Under [PANTILT SETTING] choose [GOTO ZERO POSITION] menu, press [OPEN] to confirm the selection and enter to the zero point setting. The camera will move to the zero position. 4. Press [CLOSE] to return to the previous menu. Preset Point Setting Menu PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP PRESETS SETUP PRESET NUMBER : 001 TITLE : SET NEW PRESET SHOW NEXT PRESET DELETE CURRENT This camera supports 200 preset points. 19

Preset Number Setting 2. Use Up/Down P/T to choose [PANTILT SETTING] and press [OPEN] to confirm the selection and enter preset set menu. 3. Under [PANTILT SETTING] choose the [PANTILT SETTING] sub-menu and press [OPEN] to confirm the selection. 4. Under [PANTILT SETTING] choose [PRESET NUMBER] menu to enter to the preset point setting, and the parameter will blink. 5. Use Up/Down P/T to choose a preset number. 6. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. Note: If the preset point already contains data, the dome camera will call the position to alert you that the preset will be written over. TITLE SETTING 1. Under [PANTILT SETTING] choose [TITLE] for entering into the title change menu, Edit title of the preset point will be shown on the screen and the parameter will blink. 2. Use Up/down P/T to set the characters of the preset name. 3. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. SET NEW PRESET 2. Up/Down cursor to choose [PANTILT SETTING], press [OPEN] to confirm the selection and enter pan set menu. 3. Under [PANTILT SETTING] choose [PANTILT SETTING] menu, press [OPEN] to confirm the selection. 4. Under [PANTILT SETTING] choose [SET NEW PRESET] to enter into the preset point setting. The display will show Press IRIS OPEN. First move the camera to the position you would like to set for the preset, and then press IRIS CLOSE. Instruction: The preset point number should be selected first before defining, displaying and deleting the preset point or editing the title. SEQUENCE SETUP Individual preset points can be strung together to create a sequence, also known as a tour. Each sequence can contain up to 32 preset points and each preset can have the dwell time set individually. PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE NUMBER SETUP PATTERN SETUP 20 SEQUENCE SETUP SEQUENCE NUMBER : 001 DEFAULT DWELL : 001 EDIT SEQUENCE RUN CONTINUOUSLY DELETE CURRENT

2. Use the Up/Down cursor to choose [PANTILT SETTING], press [OPEN] to confirm the selection and enter sequence set menu. 3. Under [PANTILT SETTING] choose [SEQUENCE SETUP] and press [OPEN] to confirm the selection. 4. Under [SEQUENCE SETUP] choose [SEQUENCE NUMBER] to enter the sequence number setting and the parameter will blink. 5. Up/down P/T to choose a sequence number. 6. Press [OPEN] to confirm the selection. 7. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. Note: The sequence number to be edited must be chosen prior to making any changes to the sequence. EDIT SEQUENCE 2. Use the Up/Down cursor to choose [PANTILT SETTING] and press [OPEN] to confirm the selection. 3. Under [PANTILT SETTING] choose [EDIT SEQUENCE] and press [OPEN] to confirm the selection. The list of sequence steps will be shown on screen and the first point will blink, indicating it can be changed. 4. Use the Up/down and L/R PTZ controls to assign a preset for each step of the sequence. If a preset is not assigned to a step, the sequence will skip that step. 4. Once all steps are set, press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. Note: Each group of parameters has two numbers, the first represents the preset point number and the second is the dwell time. The dwell time for every preset point is decided by the default time when it is not changed. The user can also set the dwell time of every preset point individually. Each sequence supports a maximum of 32 presets. PATTERN SETUP The dome camera can record 1000 different PTZ actions continuously, including pan, tilt and zoom control, iris and focus settings etc. The dome will retrace those movements when the recorded pattern is played back. 4 patterns can be stored. PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP PATTERN SETUP PATTERN NUMBER : 001 TITLE :PAT1 RECORD NEW PATTERN RUN CONTINUOUSLY DELETE CURRENT RECORD NEW PATTERN 2. Use the Up/Down cursor to choose [PANTILT SETTING] and press [OPEN] to confirm the 21

selection and enter pan set menu. 3. Under [PANTILT SETTING] choose [PATTERN SETUP] and press [OPEN] to enter route recording mode. 4. Under [PATTERN SETUP] choose [RECORD NEW PATTERN] and press [OPEN] to enter mode route recording setting. 5. Press [OPEN] and pattern recording will begin immediately. Recording Mode Route will be shown on the screen. Operate the dome camera following the desired route. All movements at this time are being recorded. 6. To finish recording, press [OPEN] and the pattern recording will automatically be saved. 7. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. AUTOSCAN SETUP a) This cameral supports auto scan. The camera will scan horizontally between user-defined left and right points, with steady speed and zoom levels. b) The machine will scan a 360 rotation if the left and right points are set to the same position. PANTILT SETTING PANTILT SETTING Auto Scan Number PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP AUTOSCAN NUMBER : 001 TITLE :SCAN1 SET LEFT LIMIT SET RIGHT LIMIT DEFAULT SPEED RUN CONTINOUSELY 2. Use the Up/Down cursor to choose [PANTILT SETTING] and press [OPEN] to confirm the selection and enter pan set menu. 3. Under [PANTILT SETTING] choose [AUTOSCAN SETUP] and press [OPEN] to confirm the selection. 4. Under [AUTOSCAN SETUP] press [AUTOSCAN NUMBER] and choose 1 of the 4 autoscan routes to be edited. Use the Up/down P/T to choose a scan route. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. SET LEFT LIMIT 1. Under [PANTILT SETTING] choose [SET LEFT LIMIT] and press [OPEN] to prepare for setting the left limit point. 2. Operate the PTZ control to guide the camera to the location desired for the left limit point. 3. Press [OPEN] when the scan left point has been set and the system will automatically record the current position as the left edge for scanning. 4. Press [CLOSE] to exit the left limit setting. Note: The scan left limit point can be set at any point on the horizontal axis. The right edge setting utilizes the same method as the left point. DEFAULT SPEED 22

Adjusts the L/R scan speed. The speed range is adjustable from 1 to 64. 2. Move cursor to choose [PANTILT SETTING] choose [AUTOSCAN SETUP] and press [OPEN] to confirm the selection to enter scan function set item. 3. Under [AUTOSCAN SETUP] choose [DEFAULT SPEED] item and press [OPEN] to confirm the selection to enter default scan speed set item. 4. Up/down P/T to change speed value, the speed can be set from 1 to 64. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. HOME ACTION If the camera does not receive any commands for a set time, it can perform a specific action set on this screen. The time can be set from 5 to 255 and the action to perform can be to call any of the 200 presets, 4 sequences, 4 scans or 4 patterns. PANTILT SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PRESETS SETUP AUTOSCAN SETUP HOME TIME HOME ACTION HOMETIME : 255 HOME ACTION : OFF 2. Use the Up/down cursor to choose [PANTILT SETTING] choose [HOME ACTION] item and press [OPEN] to confirm the selection. 3. Under [HOME ACTION] choose [HOME TIME] item and press [OPEN] to confirm the selection and enter into the home time setting item. 4. Use Up/down P/T to modify the delay time, from 5 to 255 seconds. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. HOME ACTION 6. Call preset point 95 to enter the main menu. 7. Use the Up/down cursor to choose [PANTILT SETTING] choose [HOME ACTION] item and press [OPEN] to confirm the selection. 8. Under [HOME ACTION] choose [HOME ACTION] item and press [OPEN] to confirm the selection and set the home action item. 9. Use Up/down P/T to modify the home action. The action to perform can be to call any of the 200 presets, 4 sequences, 4 scans or 4 patterns. 23

10. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. INFORMATION DISPLAY CONFIGURATION This menu sets whether or not various information is displayed within the camera s video output and if so, the time duration of the display. MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PANTILT SETTING DISPLAY CONFIGURATION ALARMS SETUP DISPLAY CONFIGURATION DOME TITLE : ON PRESETS TITLE : ON ZOOM POSITION : ON DIRECTION INDICATOR : ON ENVIRONMENTAL INDICATORS : ON GLOBAL SETTING DOME TITLE 2. Use the Up/Down cursor to choose [DISPLAY CONFIGURATION] and press [OPEN] to confirm the selection. Under [DISPLAY CONFIGURATION] choose [DOME TITLE] and press [OPEN] to confirm the selection. 3. Up/down P/T to modify Camera Title Display time. If OFF is chosen, the Dome Title will not be displayed on the OSD. If ON is chosen, the title will always be displayed. If a time is chosen (in seconds), the title will be displayed on the OSD for that amount of time, then it will stop being displayed and not be displayed again until a PTZ command is received from a controller. 4. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. Note: Preset Title, Zoom Position, Direction Indicator and Environmental Indicators are all set using the same method as Dome Title. GLOBAL SETTING 1. All of the OSD data displays can be set simultaneously by choosing this option and pressing [OPEN] to engage the global setting to turn all data displays on or off. Alarms setup Alarm function setting menu. MAIN MENU SYSTEM SETTING CAMERA PARAMETERS PANTILT SETTING DISPLAY CONFIGURATION ALARMS SETUP INPUT CHANNEL: 001 ALARM ACTION : DISARM INPUT MODE : NO ALARM LINKAGE: OFF RELAY OUTPUT : OFF RESET DELAY : 30 24

The camera supports 2 alarm inputs and 2 alarm outputs. When an alarm input is triggered, the following actions can be executed: An alarm input trigger can cause the dome to immediately go to any preset for surveillance. Either alarm output channel relay can activate external alarm equipment. Automatic alarm priority system (1st is the higher-priority the 2 nd is the lower-priority). The dome will automatically utilize the high and low priority to receive 2 alarm signals at the same time. Alarm inputs can be set either Normally Open or Normally Closed. For details please refer to the procedure below. ALARMS SETUP 2. Use the Up/Down cursor to choose [ALARMS SETUP] and press [OPEN] to confirm the selection and enter alarm set items. 3. Under [ALARMS SETUP] choose [ALARM ACTION] item, press [OPEN] to confirm the selection. 4. Use the Left/right P/T controls to choose arming or disarming the alarm function. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. INPUT MODE Setting Methods: NC: Normally Closed. The normal alarm-off state of the input is a closed circuit. Opening the circuit triggers the alarm. NO: Normally Open. The normal alarm-off state of the input is an open circuit. Closing the circuit triggers the alarm. Note: This camera may be wired for 2 alarm inputs or 4 alarm inputs. This model supports 2 alarm inputs and the wiring for inputs 3 and 4 are not utilized on this model. 2. Use the Up/Down cursor to choose [ALARMS SETUP] and press [OPEN] to confirm the selection and enter alarm set items. 3. Under [ALARMS SETUP] choose [INPUT MODE] and press [OPEN] to confirm the selection. Use the Left/right P/T controls to choose (normally) open or (normally) closed. 4. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. 25

ALARM LINKAGE This function is used to select which action is taken by the camera when an alarm input is triggered. E.g., Auto Scan 1 thru 4,Preset Point 1 thru 200, Sequence 1 thru 4 etc. 2. Use the Up/Down cursor to choose [ALARMS SETUP] and press [OPEN] to confirm the selection and enter Alarms Setup. 3. Under [ALARMS SETUP] choose [ALARM LINKAGE] and press [OPEN] to confirm the selection. 4. Use the Left/right P/T controls to change alarm function linkage, E.g, Auto Scan 1 thru 4, Preset Point 1 thru 200, Sequence 1 thru 4 etc 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. RELAY (AUX) OUTPUT This sets whether or not to link the alarm output relays to alarm events generated by the camera. Note: The alarm output relays are configured for N.O. (Normally Open) operation. Please ensure all equipment for use with the alarm outputs can be configured for N.O. operation. 2. Use the Up/Down cursor to choose [ALARMS SETUP] and press [OPEN] to confirm the selection and enter alarm set items. 3. Under [ALARMS SETUP] choose one of the 2 alarm inputs to link to a relay (AUX) output. 4. Select [RELAY OUTPUT] and press [OPEN] to confirm the selection. 5. Use the Up/Down P/T controls to choose relay output 1, 2 or off. 6. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. RESET DELAY This function sets how long an alarm takes to reset itself after it has been triggered. The time range is 1-255 seconds. 2. Use the Up/Down cursor to choose [ALARMS SETUP] and press [OPEN] to confirm the selection and enter alarm set items. 3. Under [ALARMS SETUP] choose [RESET DELAY] and press [OPEN] to confirm the selection. 4. Use the Left/right P/T controls to change the rest time. 1-255 seconds can be selected. 5. Press the [OPEN] key to save and exit. Press the [CLOSE] key to exit directly without saving. 26

TROUBLESHOOTING a. No picture after applying power (i) check all plugs and cables are connected to the proper connectors: (ii) ensure your power supply is providing the correct voltage and enough current. b. The picture has ripples (i) Check to see if the power supply is experiencing AC ripple. If so, a filter may be required. (ii) Determine if the monitor is faulty. (iii) Determine if other peripheral equipment is causing the ripple and if so make the necessary adjustments. c. The picture background continuously changes color A fluorescent lamp s magnetic field may cause color roll. If possible, increase the distance between the camera and any fluorescent lamps in the vicinity. d. The picture appears smeared (i) The power supply voltage level may be unstable. Try another power supply. (ii) Ensure the cables are correctly connected and of the right impedance. e. Other interference may require the use of a SecurityTronix ground loop isolation filter. f. Power is on but the controller does not work (i) Check to make sure the DIP switches are all set correctly for address, baud rate and protocol. (ii) Check that the RS485 wires at the camera and controller have correct polarities. (iii) Check the integrity and continuity of the Unshielded Twisted Pair (UTP) cable. Additional troubleshooting assistance can be found online at www.securitytronix.com or email us at support@securitytronix.com or call (610) 429-1511 on the east coast or (702) 308-4220 on the west coast. 27