CR3000 Copy Reader. Installation Guide

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Digital Keypad Introduction

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

MS-7000: SuperStar Reader

EP/2 Installation Instructions

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Operation and Maintenance Manual

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

the Interactive Catalog

Model 7701 Multiplexer Module

LANCNC FTP Data Server for CNC Controls Machine Mount instructions

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

MS-5000: MiniStar Reader

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

TOXALERT MODEL AIR 2000

Junos WebApp Secure 5.0 Hardware Guide

232iLM Keypad Installation and Programming Instructions

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Hardened PoE Ethernet Switch

MultiConnect Adapters

Installation Guide DRAFTMF4100

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Basketball Shot Clock Set LX2180 Manual

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

212iL Rev. 1.1

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

MODEL 8000MP LEVEL SENSOR

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

RS3000 SERIES BILL ACCEPTORS

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

ETC Installation Guide

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

A-dec 586 Ceiling Monitor Mount

BA/BS4S Temperature Sensor Installation & Operating Instructions

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

MegaTrak MCU-9000 Harness Wiring

Mounting DIGITAL DISPLAY

MBE Mounts and Adapters

Cardax Prox Plus Mifare Reader

Code Dynamics, Inc. Port Splitter

Two Door Controller GEN-045

INSTALLATION INSTRUCTIONS

INJ-24A Series Quick Installation Guide

CMSA-100 Manual. Cinema Media Server Automation

Megatouch FORCE Monitor Chassis Board Replacement

MS-3000 MicroStar Reader

Haworth Power Technical Sheets January 2018

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

MS-4000: ShootingStar Reader

INSTALLATION INSTRUCTIONS

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

ELECTRO-MECH SCOREBOARD CO.

CONFIGURATION: The Reader, LED Indicator, pin numbers for the 9-pin connector and the 25-pin adapter are shown in Figure 1-2.

AC-43 Accelerometer. User Manual

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

ImproX IXP20 Controller INSTALLATION MANUAL

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Inductive Proximity Sensors E51 Limit Switch Style, Modular

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

CHAPTER Wi r i n g NOTICE:

Industrial PoE Media Converter

MOXA EtherDevice Switch & PoE Splitter

4170 POS System Installation Guide

Model 7416LED

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

Ethernet Adapter Installation Instructions

DirectCommand Installation DirectCommand Complete Wiring Harness

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

User Manual. PCKeypad Wireless Keypad

6222 Two Door Module Technical Operations Manual

ISSPRO 3 3/8" DIAMETER PROGRAMMABLE SPEEDOMETER Air Core Version

InSight Single Implement

An ISO-9001 Certified Company

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Perle MCR200 Installation Guide

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Amano Nexus Lite Controller INSTALLATION MANUAL

Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

XPress-Pro SW User Guide

Transcription:

Copy Machine Reader Installation and Setup Guide

CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications 4 Physical Mounting 5 Copier Connections for CR1120/CR1122 Readers 5 Wiring Connections 6 Configuring the Reader Settings 6 Removing the Reader Cover 8 DIP Switch Settings 9 CR2000/CR2002 READERS INSTALLATION 9 Copier Interface 9 AC Electrical 10 Communications 10 Physical Mounting 11 Copier Connections for the CR2000/CR2002 11 Wiring Connections 13 Configuring the Reader Settings 13 Opening the Reader 16 XEROX COPIER CONNECTIONS FOR THE CR1120/CR1122 16 Wiring Connections 17 Configuring the Reader Settings 17 Removing the Reader Cover 19 DIP Switch Settings 20 XEROX COPIER CONNECTIONS FOR THE CR2002 20 Wiring Connections Copy Reader Installation Guide 1

21 Configuring the Reader Settings 23 XEROX COPIER CONNECTIONS FOR THE CR2000 23 Wiring Connections 24 Configuring the Reader Settings 26 MOUNTING STANDS 26 Stand Materials 27 Mounting Stand: CR2000/CR2002 28 Mounting Stand: CR1120/CR1122 29 Mounting Diagrams 29 Mounting Diagram for CR1120/CR1122 30 Mounting Diagram for CR2000/CR2002 Copy Reader Installation Guide 2

COPY MACHINE READER INSTALLATION Overview This manual provides general installation instructions for Blackboard s Copy Machine Readers CR1120, CR1122, CR2000, and CR2002. Instructions are included to set baud rate, address, loop, copier specifications and mounting diagrams. READER OVERVIEW Blackboard s Copy Machine Reader is space-saving and easily mountable with a swipe style card slot. The rugged metal construction makes the reader tamper resistant and lets it withstand the abuse of high-traffic environments. The CR1120/CR1122 Reader features a one-line by 24 character liquid crystal display. The CR2000/2002 Reader with keypad features a two-line by 20 character vacuum fluorescent display. It also provides a 20-key keypad that allows account overrides or departmental charges. Each reader is engraved with a diagram to help the user properly insert the magnetic-striped card. An inactive time-out value, set through the Optim9000 System software, indicates the amount of time a Copy Machine Reader remains active while a card is still inserted but no copies are being made. Copy Machine Readers allows the Optim9000 System control the use of a copy machine and to enter information at the time of the transaction. Copy Machine readers connecting to a Universal Edition Host require an IP Converter (IPC). Reader Specifications READER COMMUNICATIONS Asynchronous, full duplex Up to 9600 bits per second RS-485 multidrop 4,000 feet per line; 16 readers per line Copy Reader Installation Guide 1

POWER CR1120/CR1122: Wall mount style transformer Input: 120 VAC, 6 W CR2000/CR2002: Voltage: 120 VAC single phase Current: 1A PHYSICAL CHARACTERISTICS CR1120/CR1122 Dimensions: 11.7 inches wide x 6 inches deep x 2.5 inches high CR2000/CR2002 Dimensions: 7.1 inches wide x 7.5 inches deep x 4.4 inches high ENVIRONMENTAL CHARACTERISTICS Operating: Temperature: 0 to +60 degrees C Relative humidity: 0 to 95 percent non-condensing Altitude: 0-10,000 feet Non-operating: Temperature: -20 to +70 degrees C Altitude: 0-35,000 feet Copy Reader Installation Guide 2

CR1120/CR1122 INSTALLATION CR1120/CR1122 reader installation is divided into four areas: Copier Interface (page 3) AC Electrical (page 3) Communications (page 3) Physical Mounting (page 4) Copier Interface The CR1120/CR1122 has an interface cable that must be connected to the copier. Signals that enable the machine and count the number of copies made are carried in this cable. The cable is 11 feet long, with a connector near the copier end for ease of removing or replacing readers and copiers. The installer must know where to connect the CR1120/CR1122 to the copy machine to receive these signals. The copier dealer or service provider must provide this information. We recommend the copier dealer or service provider install the interface cable to avoid any machine warranty or service agreement issues which may arise. A trained electronic technician should complete all wiring.the interface cable has a pigtail on the copy machine end. It is the responsibility of the installer to provide the correct connector or splices to attach to the machine. AC Electrical Every CR1120/CR1122 requires an 120 VAC (5 15R) receptacle for the AC adaptor. The cable length between the AC adaptor and the reader is five feet. Communications Communications to the Optim9000 System host is accomplished through the Optim9000 reader network. The CR1120/CR1122 is shipped with a 10-foot cable terminated with an RJ-45 connector. The reader Copy Reader Installation Guide 3

address and baud rate are set via DIP switches inside the CR1120/CR1122. See Configuring the Reader Settings (page 13) for instructions on how to set the baud rate and address. RJ-45 Connector Communications Cable Connector Interface Cable AC Adaptor Physical Mounting The mounting location for the CR1120/CR1122 should not interfere with operating or servicing the copier. Patrons who use the CR1120/CR1122 must be able to see the display and insert their cards easily. Two threaded mounting holes on the bottom are provided to secure the CR1120/CR1122 to a shelf or mounting stand. Ensure that mounting screws do not penetrate more than 1/2" into the unit or damage to the circuit board may result. For CR1120/CR1122 mounting dimensions, see (Mounting Stand: CR1120/CR1122 (page 28). Copy Reader Installation Guide 4

C OPIER CONNECTIONS FOR CR1120/CR1122 READERS COPIER CONNECTIONS FOR CR1120/CR1122 READERS This section explains the connections and DIP switches settings for most copy machines. Xerox copiers require a different approach, as described in Xerox Copier Connections for the CR1120/CR1122 (page 16). Wiring Connections CONNECTING THE WIRE HARNESS The copy machine must be designed to be enabled by a connection of two wires or terminals. The CR1120 enables the machine by a dry contact relay closure. The CR1122 enables the machine by a dry contact closure or an open relay contact. The green and white wires are for a machine that requires a contact closure to enable the machine. The green and brown wires are for a machine that requires a contact closure to disable the machine. GREEN Relay common (C) contact WHITE Relay normally open (NO) contact BROWN Relay normally closed (NC) contact (Available on CR1122 only) The copy machine must have a signal that is used to indicate that a copy has been made. This can be a +24V pulse, +5V pulse, a ground pulse, or a relay contact pulse. Pulse Type Wire Connection +24V pulse RED Connect to +24V pulse signal of copy machine 1 BLACK Connect to logic ground of copy machine +5V pulse RED Connect to +5V pulse signal of copy machine BLACK Connect to logic ground of copy machine +Ground pulse Relay contact pulse RED Connect to +5V or +24VDC supply in copy machine BLACK Connect to ground pulse signal of copy machine RED Connect to relay (sourced by CR1120/CR1122 +9V) BLACK Connect to relay (to opto in CR1120/CR1122) 1. Observe polarity or the count pulse may be invalid. Copy Reader Installation Guide 5

Set DIP switches for the correct input pulse, as described later in this section. 3x3 Molex Connector Red Black Green White Brown To Copier Pulse (+) To Copier Pulse (-) To Copier Enable (C) To Copier Enable (NO) To Copier Enable (NC) (*CR1122 Only) CONFIGURING THE READER SETTINGS The circuit board inside the CR1120/CR1122 has two banks of DIP switches. DIP switch S1 is configures the type of copy machine interface. DIP switch S2 configures the reader address and baud rate. DIP switch S1 is preset at the factory for a +24VDC pulse interface. To access the DIP switches, remove the top cover. Removing the Reader Cover To open the reader, follow these steps: 1 Remove the four tamper screws to loosen the cover piece. 2 Lift the cover from the reader. Copy Reader Installation Guide 6

Tamper Screws There is a chart on the bottom of the cover that indicates the DIP switch settings and their functions. 3 Set the DIP switches according to the chart inside the reader cover, or use the tables on the next page. S1 R9 S2 4 Plug in the CR1120/CR1122 with the cover removed and set the display s viewing angle by turning R9 with a non-conductive screwdriver. 5 Replace cover and reattach it with the tamper screws. Copy Reader Installation Guide 7

DIP Switch Settings Switch 1 settings based on the interface type are Position: 1 2 3 4 5 6 7 8 +5V Pulse Off Off Off ON Off Off ON Off +24V Pulse Off Off Off ON Off ON Off Off Dry Contact Off ON ON Off ON Off Off Off Switch 2 settings based on net type, baud rate, and address are: Position: 1 2 3 4 5 6 7 8 Standard Net Type Remote Net Type Off ON 1200 Baud Off Off Off 2400 Baud Off Off Off 4800 Baud Off ON Off 9600 Baud Off ON ON Address 0 Off Off Off Off Address 1 Off Off Off ON Address 2 Off Off ON Off Address 3 Off Off ON ON Address 4 Off ON Off Off Address 5 Off ON Off ON Address 6 Off ON ON Off Address 7 Off ON ON ON Address 8 ON Off Off Off Address 9 ON Off Off ON Address 10 ON Off ON Off Address 11 ON Off ON ON Address 12 ON ON Off Off Address 13 ON ON Off ON Address 14 ON ON ON Off Address 15 ON ON ON ON Copy Reader Installation Guide 8

CR2000/CR2002 READERS INSTALLATION CR2000/CR2002 Copy Machine Reader installation is divided into four areas: Copier Interface (page 9) AC Electrical (page 9) Communications (page 10) Physical Mounting (page 10) Copier Interface The CR2000/CR2002 has an interface cable that must be connected to the copier. Signals that enable the machine and count the number of copies made are carried in this cable. The cable is 11 feet long, with a connector near the copier end for ease of removing or replacing readers and copiers. Required signals are listed in the Copier Connections for the CR2000/CR2002 section. Required signals for Xerox Copy machines are listed in the Xerox Copier Connections for the CR2000 or Xerox Copier Connections for the CR2002 section. The installer must know where to connect the CR2000/CR2002 to the copy machine to receive these signals. The copier dealer or service provider must provide this information. We recommend the copier dealer or service provider install the interface cable to avoid any machine warranty or service agreement issues which may arise. A trained electronic technician should complete all wiring. The interface cable has a pigtail on the copy machine end. It is the responsibility of the installer to provide the correct connector or splices to attach to the machine. AC Electrical Every CR2000/CR2002 requires an 110VAC (5 15R) receptacle for the AC adaptor. The AC adaptor box has two cables: one to the wall receptacle (three feet), and the other to the reader (five feet). Copy Reader Installation Guide 9

Communications Communications to the Optim9000 System host is accomplished through the Optim9000 reader network. The CR2000/CR2002 ships with a 10-foot cable terminated with an RJ-45 connector.. RJ-45 Connector Interface Cable Connector Communications Cable AC Adaptor Physical Mounting The mounting location for the CR2000/CR2002 must not interfere with operating or servicing the copier. Patrons who use the CR2000/CR2002 must be able to see the display and insert the card from the top of the card slot. Two threaded mounting holes on the bottom are provided to secure the CR2000/CR2002 to a shelf or mounting stand. For CR2000/CR2002 mounting dimensions, see Mounting Stands (page 26) and example mounting stands are included in this manual. Copy Reader Installation Guide 10

C OPIER CONNECTIONS FOR THE CR2000/CR2002 COPIER CONNECTIONS FOR THE CR2000/CR2002 This section explains the connection and DIP switch settings for most copy machine readers. Xerox copiers require a different approach which is described in Xerox Copier Connections for the CR2000 (page 23), or see Xerox Copier Connections for the CR2002 (page 20) for CR2002 readers. Wiring Connections CONNECTING THE WIRE HARNESS The copy machine is designed to be enabled by a connection of two wires or terminals. The CR2000/ CR2002 enables the machine by a dry contact closure of a relay: BROWN - Relay common (C) contact RED - Relay normally open (NO) contact BLACK - Relay normally closed (NC) contact (CR2002 only) The copy machine must have a signal that indicates a copy was made. This can be a +24V pulse, +5V pulse, a ground pulse, or a relay contact pulse. Pulse Type Wire Connection +24V pulse GREEN Connect to +24V pulse signal of copy machine BLUE Connect to logic ground of copy machine +5V pulse GREEN Connect to +5V pulse signal of copy machine BLUE Connect to logic ground of copy machine +Ground pulse Relay contact pulse GREEN Connect to +5V or +24VDC supply in copy machine BLUE Connect to ground pulse signal of copy machine GREEN Connect to relay (sourced by CR2000 +24V) BLUE Connect to relay (to opto in CR2000) Be sure to set DIP switches for the correct input pulse, as described later in this section. Copy Reader Installation Guide 11

C OPIER CONNECTIONS FOR THE CR2000/CR2002 3x3 Molex Connector Green Blue Brown Red Black To Copier Pulse (+) To Copier Pulse (-) To Copier Enable (C) To Copier Enable (NO) To Copier Enable (NC) (CR2002 Only) Copy Reader Installation Guide 12

CONFIGURING THE READER SETTINGS The interface board inside the CR2000/CR2002 has two banks of DIP switches for configuring the type of copy machine interface. It is preset at the factory for a +24VDC pulse interface (or ground pulse using +24VDC supply). The DIP switches are on the board attached to the inside of the bottom cover. The installer must open the reader to access them. Opening the Reader To open the reader, follow these steps: 1 Place the reader upside down on a non-abrasive surface. 2 Remove the 10 tamper screws that hold the base to the face plate. 3 Carefully lift the bottom of the reader as illustrated below. Do not pull on the ribbon cable that connects the base to the face plate. Lift at the narrow end, using the wide end as a pivot. The DIP switches can be accessed once the reader is open. They are located in the base near the ribbon cable that connects the two halves of the reader together. Copy Reader Installation Guide 13

S1 S2 The DIP switch assembly area is as shown in this diagram. Relay ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 RJ-12 Jack S1 S2 4 Follow the guidelines in the table below to set DIP switches for the CR2000/CR2002. Pulse Type Switch 1 2 3 4 5 6 7 8 +24VDC pulse 1 S1 Off Off Off ON Off ON Off Off S2 Off Off Off Off Off Off Off Off Copy Reader Installation Guide 14

Pulse Type Switch 1 2 3 4 5 6 7 8 +5VDC pulse 2 S1 Off Off Off ON Off Off ON Off S2 Off Off Off Off Off Off Off Off Relay contact pulse S1 Off Off ON Off ON Off Off ON S2 Off Off Off Off Off Off Off Off 1. Or ground pulse using +24VDC supply. 2.Or ground pulse using +5VDC supply. 5 Adjust DIP switches and reassemble. Copy Reader Installation Guide 15

XEROX COPIER CONNECTIONS FOR THE CR1120/ CR1122 This section explains the connection and DIP switch settings for Xerox copiers. All Xerox copiers with a DB15 foreign device interface are supported using the supplied Xerox adapter cable. Refer to Copier Connections for CR1120/CR1122 Readers (page 5) or contact Blackboard Technical Services if the Xerox machine does not have a DB15 interface connector. Wiring Connections CONNECTING THE WIRE HARNESS Use the Xerox adapter cable (P/N 044-042-030) in place of the pigtail adapter to connect to the machine. The information below is for reference only. Wire Color Connection Red To Xerox DB-15 interface connector pin #8 Copy count + Black To Xerox DB-15 interface connector pin #9 Copy count - Green White To Xerox DB-15 interface connector pin #1 Copier enable To Xerox DB-15 interface connector pin #3 Copier enable Be sure to set DIP switches for the correct input pulse. Copy Reader Installation Guide 16

3x3 Molex Connector Red Black Green White Brown To Copier Pulse (+) To Copier Pulse (-) To Copier Enable (C) To Copier Enable (NO) Not Connected Xerox DB-15 8 9 1 3 CONFIGURING THE READER SETTINGS The circuit board inside the CR1120/CR1122 has two banks of DIP switches. DIP switch S1 configures the type of copy machine interface. DIP switch S2 configures the reader address and baud rate. To access the DIP switches, remove the top cover. Removing the Reader Cover To open the reader, follow these steps: 1 Remove the four tamper screws to loosen the cover piece. 2 Lift the cover from the reader. Copy Reader Installation Guide 17

Tamper Screws There is a chart on the bottom of the cover that indicates the DIP switch settings and their functions. 3 Set the DIP switches according to the tables below. S1 R9 S2 4 Plug in the CR1120/CR1122 with the cover removed and set the display s viewing angle by turning R9 with a non-conductive screwdriver. 5 Replace cover and reattach it with the tamper screws. Copy Reader Installation Guide 18

DIP Switch Settings Switch 1 settings are: 1 2 3 4 5 6 7 8 Off ON ON Off ON Off Off Off Switch 2 settings based on net type, baud rate, and address are: Position: 1 2 3 4 5 6 7 8 Standard Net Type Remote Net Type Off ON 1200 Baud Off Off Off 2400 Baud Off Off Off 4800 Baud Off ON Off 9600 Baud Off ON ON Address 0 Off Off Off Off Address 1 Off Off Off ON Address 2 Off Off ON Off Address 3 Off Off ON ON Address 4 Off ON Off Off Address 5 Off ON Off ON Address 6 Off ON ON Off Address 7 Off ON ON ON Address 8 ON Off Off Off Address 9 ON Off Off ON Address 10 ON Off ON Off Address 11 ON Off ON ON Address 12 ON ON Off Off Address 13 ON ON Off ON Address 14 ON ON ON Off Address 15 ON ON ON ON Copy Reader Installation Guide 19

XEROX COPIER CONNECTIONS FOR THE CR2002 This section explains the connections and DIP switches settings for Xerox copiers. All Xerox copiers with a DB15 foreign device interface are supported using the supplied Xerox adapter cable. Refer to Copier Connections for the CR2000/CR2002 (page 11) or contact Blackboard Technical Services if the Xerox machine does not have a DB15 interface connector. Wiring Connections CONNECTING THE WIRE HARNESS Use the Xerox adapter cable (P/N 044-042-030) in place of the pigtail adapter to connect to the machine. The information below is for reference only. Wire Color Connection Blue To Xerox DB-15 interface connector pin #8 Copy count + Gray To Xerox DB-15 interface connector pin #9 Copy count - Red Brown To Xerox DB-15 interface connector pin #1 Copier enable To Xerox DB-15 interface connector pin #3 Copier enable Set DIP switches for the correct input pulse, as described later in this section. Xerox DB-15 1 3 8 9 Red Brown Blue Gray 3x3 Molex Connector Copy Reader Installation Guide 20

CONFIGURING THE READER SETTINGS The interface board inside the CR2002 has two banks of DIP switches for configuring the copy machine interface. It is preset at the factory for a +24VDC pulse interface (or ground pulse using +24VDC supply). The DIP switches are on the board attached to the inside of the bottom cover. The reader must be opened to access the DIP switches. To open the reader: 1 Place reader upside down on a non-abrasive surface. 2 Remove the ten tamper screws that hold the base to the face plate. 3 Carefully lift as illustrated below. Do not pull on the ribbon cable that connects the base to the face plate. Lift at the narrow end, using the wide end as a pivot. DIP switches are in the base near the ribbon cable that connects the two halves. The DIP switches can be accessed when the reader is open. S1 S2 Copy Reader Installation Guide 21

The DIP switch assembly area is as shown in this diagram. Relay ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 RJ-12 Jack S1 S2 4 Follow the guidelines in the table below to set the DIP switches. Switch 1 2 3 4 5 6 7 8 S1 Off ON ON Off ON Off Off Off S2 Off Off Off Off ON Off Off Off Copy Reader Installation Guide 22

XEROX COPIER CONNECTIONS FOR THE CR2000 This section explains the connection and DIP switches settings for Xerox copiers. All Xerox copiers with a DB15 foreign device interface are supported. Refer to the General Copier Connections for the CR2000 or contact Blackboard Technical Services if the Xerox machine does not have a DB15 interface connector. Wiring Connections CONNECTING THE WIRE HARNESS Use these guidelines to connect the colored wires to the interface connector. Wire Color Connection Blue To Xerox DB-15 interface connector pin #8 Copy count + Gray To Xerox DB-15 interface connector pin #9 Copy count - Red To Xerox DB-15 interface connector pin #1 Copier enable Brown To Xerox DB-15 interface connector pin #3 Copier enable Violet To green wire Green To violet wire Set DIP switches for the correct input pulse, as described later in this section. Copy Reader Installation Guide 23

Xerox DB-15 1 3 8 9 Red Brown Blue Gray 3x3 Molex Connector Violet Green Connect violet and green wires together The interface cable has a pigtail on the copy machine end. It is the responsibility of the installer to provide the correct connector or splices to attach to the machine. CONFIGURING THE READER SETTINGS The interface board inside the CR2000 has two banks of DIP switches for configuring the copy machine interface. It is preset at the factory for a +24VDC pulse interface (or ground pulse using +24VDC supply). The DIP switches are on the board attached to the inside of the bottom cover. The DIP switches can be accessed when the reader is open. To open the reader: 1 Place reader upside down on a non-abrasive surface. 2 Remove the ten tamper screws that hold the base to the face plate. 3 Carefully lift as illustrated below. Do not pull on the ribbon cable that connects the base to the face plate. Copy Reader Installation Guide 24

Lift at the narrow end, using the wide end as a pivot. DIP switches are in the base near the ribbon cable that connects the two halves.the DIP switches can be accessed when the reader is open. S1 S2 The DIP switch assembly area is as shown in this diagram. Relay ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 RJ-12 Jack S1 S2 4 Follow the guidelines in the table below to set the DIP switches. Switch 1 2 3 4 5 6 7 8 S1 Off Off Off ON Off ON Off Off S2 Off Off ON Off Off ON Off ON Copy Reader Installation Guide 25

M OUNTING STANDS The CR1120/CR1122 or the CR2000/CR2002 Copy Machine Readers can be mounted on a separate stand to avoid drilling holes in the copy machine. This stand can be created by using the materials and construction shown on the next pages. Stand Materials Parts for either stand must be welded together. CR1120/CR1122 STAND MATERIALS Material needed to create the stand for the CR1120/CR1122: 2-1/8" thick Steel Plates: 1-8 1/2" x 12" Steel Plate 1-11 3/4" x 6" Steel Plate 1-3-foot Length of Steel Tubing (1 1/2 Outside Diameter) CR2000/CR2002 STAND MATERIALS Material needed to create the stand for the CR2000/CR2002: 2-1/8" thick Steel Plates: 1-8 1/2" x 12" Steel Plate 1-6" x 6" Steel Plate 1-3-foot Length of Steel Tubing (1-1/2 Outside Diameter) Copy Reader Installation Guide 26

M OUNTING STAND: CR2000/CR2002 MOUNTING STAND: CR2000/CR2002 6 } 1/8" thickness 6" 8 1/2" 3/4 View Materials: 2 Steel Plates 1/8" thick 1-8-1/2" x 12" 1-6" x 6" Tubing, 1-1/2 outside diameter 30" overall length, bent at 90 degree angle at the 1/3 mark to create an L shape, with one leg at 10", the other at 20" The tube is welded to the center lines of the steel plates All materials should be painted flat black. 20" 4" 6" } 1/8" thickness 2" 8-1/2" 1/8" thickness { " Side View 12" } 4" 1/8" thickness 6" 6" Top View Copy Reader Installation Guide 27

M OUNTING STAND: CR1120/CR1122 MOUNTING STAND: CR1120/CR1122 6 } 1/8" thickness 12" 10" 12" 8-1/2" 3/4 View 20" Side View 4" 6" Materials: 2 Steel Plates 1/8" thick 1-8-1/2" x 12" 1-6" x 11-3/4" Tubing, 1-1/2 outside diameter 30" overall length, bent at 90 degree angle at the 1/3 mark to create an L shape, with one leg at 10", the other at 20" The tube is welded to the center lines of the steel plates All materials should be painted flat black. 2" 1/8" thickness { Top View 11-3/4" } 1/8" thickness 8-1/2" 4" 1/8" thickness } 6" 11-3/4" Copy Reader Installation Guide 28

M OUNTING DIAGRAMS MOUNTING DIAGRAMS This section contains a diagram of where the mounting holes are located on the bottom of the CR1120/ CR1122 and CR2000/CR2002 Copy Readers. These mounting holes allow the reader to be bolted to a mounting plate. Mounting Diagram for CR1120/CR1122 2.000 7.600 2.000 2. Front of Reader 2. 2X 10-32 UNC.375 Maximum Mounting Screw Penetration Copy Reader Installation Guide 29

M OUNTING DIAGRAMS Mounting Diagram for CR2000/CR2002 6.400 Bottom of Reader Shown 10-32 X.250 Deep Threaded Holes 6.250 3 3.125 Front of Reader 1.700 3.000 1.700 Copy Reader Installation Guide 30