Rack Installation Guide

Similar documents
CMA Installation Guide

Rack Installation Instructions

Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions

Rack Installation Instructions

IBM. Rack Installation Instructions

Rack Installation Instructions

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

System Storage DS3950 Quick Start Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

IBM TotalStorage NAS 200 Model 25T. Quick Start Instructions

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

2U, 4U, and 7U Systems

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

FreeNAS Mini and Mini XL Network Upgrade Kit

Installing the Cisco MDS 9020 Fabric Switch

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Dell PowerEdge R940. Upgrading the dual processor to quad processor system

IBM System Storage DCS3860 Quick Start Guide

Cable Routing Procedures for Dell PowerEdge R630 Systems

1 Getting Started Installing & Configuring

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

SCv360 Expansion Enclosure

EXN4000 Storage Expansion Unit Installation and Setup Instructions

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

EXN3000 Storage Expansion Unit Installation and Setup Instructions

Installation Job Aid for Avaya Virtual Services Platform 8400

Quick start guide for p5 520 ( )

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

120Ra-1 Pentium III Processor Installation Insert

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

N3150 Installation and Setup Instructions

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Dell SC460 Expansion Enclosure Getting Started Guide

SGI InfiniteStorage 120

Installing the Server into a Rack

Brocade VDX Four-Post Flush and Recessed Mount Rack Kit

IBM Systems. Quick start guide for IBM System p5 505 ( )

sata drive rack MODEL MAN UM

ProLiant ML350 Tower-to-Rack Conversion Guide. First Edition (September 2000) Part Number Compaq Computer Corporation

CHASSIS INSTALLATION GUIDE

Quick start guide for i5 520 ( or )

VERTIV VR RACK. Selection Guide

Dell MD1280 Storage Enclosure Getting Started Guide

RittalXpress TS IT Enclosure Assemble-to-Order Program

Lenovo 42U 1200mm Deep Racks Product Guide

ST101-SR Installation Guide

TRC-190 User s Manual

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

N3220 Installation and Setup Instructions

Heat Containment System (HCS)

Dell Wyse Client VESA Mounting Bracket for Dell P Series Monitor Installation Instructions

TRC-190 User s Manual

16Hi HARDWARE INSTALLATION GUIDE

Customer Upgrade Procedure

A-MOD DESKTOP OWNER S MANUAL

HP EVA4400 M6412 drive enclosure

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Junos WebApp Secure 5.0 Hardware Guide

E1135C PDU and Pod Upgrade Procedure

Netfinity White Paper Netfinity Technology Center

Dell Networking S4100-ON Series. Set-Up Guide

Rack Installation Guide

Quantum DXi4700 Capacity Upgrade Guide

350 East Plumeria Drive San Jose, CA USA February

Eaton Heat Containment System (HCS) Installation Guide

Dell SC7020 Storage Controller Getting Started Guide

Installation guide. for Cisco TelePresence MX700 Dual Camera mounted on the wall

Before you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installing IDS-4235 and IDS-4250

S5048F-ON. Set-up Guide

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Hard Drive user manual

Privileged Access Appliance Hardware Installation

HAW-SIBU. Rack Installation Guide. Version 1.0.1

Remote Support Appliance Installation

Installing the Cisco SFS 3504 Server Switch

Extra Large Full Motion TV Mount for Televisions

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

Hard Drive user manual

Dell Networking C9010 Getting Started Guide

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

INSTALLATION INSTRUCTIONS

350 East Plumeria Drive San Jose, CA USA May

Server Rack Cabinet Compatibility Guide

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

DIGITAL Server Rackmount Installation Guide

Rackmount Console quick install guide

Spare Parts Replacement Guide. for Cisco TelePresence MX800 Dual

N3240 Installation and Setup Instructions

Transcription:

Rack Installation Guide This document provides important information about the Toolless Slide Rail and the Toolless Slide Rail Kit with 1U/2U MA. Each slide rail kit package contains the following items: One left rail One right rail Two M6 screws Toolless Slide Rail Toolless Slide Rail Kit with 1U/2U MA 730 mm (28.74 inches) 818 mm (32.20 inches) You might have either the Toolless Slide Rail or the Toolless Slide Rail Kit with 1U/2U MA. If you have purchased the Toolless Slide Rail, you can purchase the 1U/2U MA Upgrade Kit for Toolless Slide Rail to help you manage your cables. If you have purchased the Toolless Slide Rail Kit with 1U/2U MA, a MA kit is delivered with the rail kit. To install the MA, refer to the installation guide provided with the MA. You can also remove the MA mounting brackets to reduce the length of the rails so that the rails can adapt to shallow racks or racks with rear vertical power distribution units (PDUs). To remove the brackets, see Removing the MA mounting brackets on page 7. A quick response (QR) code for a video of the installation process is provided to help you install the rail kit. You can scan one of the following QR codes to access to the installation video. Youtube: Youku: 1

Read these guidelines first Review the documentation that comes with the rack for safety and cabling information. Before you install the server into a rack, review the following guidelines: Install the server in a rack that meets the following requirements: Minimum depth of 70 mm (2.76 inches) between the front mounting flange and inside of the front door. Minimum depth of 214 mm (8.43 inches) between the chassis rear wall and inside of the rear door. The maximum distance between the front mounting flange and the rear mounting flange is 864 mm (34.00 inches). If you want to install the rails and a 0U PDU into the same rack, the rack must meet the following height and depth requirements: - 42U or higher - At least 1000-mm (39.37-inch) deep if no MA is to be installed - At least 1200-mm (47.24-inch) deep if a MA is to be installed Install the server only into a rack that has perforated doors. Remove the rack doors and side panels for easier access during installation. Plan the device installation starting from the bottom of the rack. Install the heaviest device in the bottom of the rack. See the server Maintenance Manual or Setup Guide for the requirements on room air temperature. Do not block any air vents, usually 15 cm (6 inches) of air space provides proper airflow. Do not leave open space above or below an installed server in your rack. To help prevent damage to server components, always install a filler panel to cover the open space and to help ensure proper air circulation. Do not extend more than one device out of the rack at the same time. Do not overload the power outlet when multiple devices are in the rack. AUTION: Use safe practices when lifting. 18 kg (39.7 lb) < 32 kg (70.5 lb) 32 kg (70.5 lb) < 55 kg (121.2 lb) 55 kg (121.2 lb) < 100 kg (220.5 lb) AUTION: Do not place any object on top of rackmounted devices. 2

Installing the slide rail kit This topic provides instructions on how to install a server into a rack using the Toolless Slide Rail Kit with 1U/2U MA. The installation procedure also applies to the Toolless Slide Rail. 1. Install the rear mounting bracket of the left rail from the front of the rack. Attention: You must install the rear mounting brackets of the rails before installing the front mounting brackets. There are two rails, left rail (marked with L) and right rail (marked with R). You can install the rails into racks with square holes or round holes. Follow the steps to install each rail onto the flanges. Fully slide the outer rail toward the rear of the rack. Line up the pins on the rear of the rail with the corresponding holes in the rear mounting flange of the rack. Attach the rear mounting bracket to the frame by pushing the rail toward the outside of the rack as shown until the rear latch opens. Push the rail backward until the pins are inserted into the corresponding holes and the rear latch rotates back to the closed position. Left rail Rear Front 1U Square hole rack (viewed from the rear of the rack) Round hole rack (viewed from the rear of the rack) 3

2. Install the front mounting bracket of the left rail. Slide the inner rails all the way back so that the front latch can be opened. Rotate the front latch and line up the pins on the front of the rail with the corresponding holes in the front mounting flange of the rack. Pull the entire rail forward until the pins protrude through the holes. Release the front latch to lock the rail into position. 3. Repeat steps 1 and 2 to install the right rail to the opposite side of the rack. 4. If you want to ship the rack with the server installed or place the rack in a vibration-prone area, install the M6 screws into the rear of the rails. 4

5. Install the server onto the inner rails. Pull the rails forward until the inner rails click two times into place. arefully lift the server and tilt it into position over the rails so that the mounting studs on the server line up with the mounting holes in the inner rails. Slowly lower the server down until the rear mounting studs slide into the rear mounting holes, and then the front mounting studs go into the corresponding mounting holes in the rails. Ensure that the mounting studs are locked into position so the server is firmly secured. aution: Ensure that two people are lifting the server together. Their hands must be positioned as illustrated. 2 2 43 1 1 6. Slide the server into the rack. Lift the locking levers on both sides of the rails. Push the server all the way into the rack until it clicks into place. 7. Secure the server before you move the rack, or if you place the rack in a vibration-prone area. Open the latches in the front of the server, and then tighten the screws. 2 1 5

To remove the server from the rails, do the following: Press the blue touch points at the front of both the inner rails. arefully rotate the server upward. Lift the server out of the rails. 6

Removing the MA mounting brackets To remove the MA mounting brackets from the Toolless Slide Rail Kit with 1U/2U MA, perform the following steps before you install the rails onto the rack. 1. Fully extend the rails as shown in the following illustration. D E D E D E D E DE D 2. Remove the MA mounting brackets from the rails using a T9 Torx screwdriver. E E E D D D 7

Second Edition (June 2017) LIMITED AND RESTRITED RIGHTS NOTIE: If data or software is delivered pursuant to a General Services Administration GSA contract, use, reproduction, or disclosure is subject to restrictions set forth in ontract No. GS-35F-05925. Product and service names appearing herein are trademarks or service marks of their respective owners. Printed in hina (1P) P/N: 00YD900 *1P00YD900*