Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Similar documents
INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Installation Guide (ver 1.0)

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

Installation Guide (ver 1.0)

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

IP based Fingerprint Access Control. Installation Guide.

Manual er under oversettelse til norsk.

BioEntry W. Installation Guide. Compact Outdoor Fingerprint Reader/Controller EN BEW V1.20.

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

GENERAL QUICK START GUIDE

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

INSTALLATION GUIDE BioEntry Plus English Version 2.11 EN BEP V2.11A

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A

EX8. User Manual. Ver 1.0

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Digital Keypad Introduction

Connecting a Cisco Reader Module

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

Zodiac FR100 TM INSTALLATION MANUAL

User Manual. Before using this device, read and follow all instructions for safety

Single Door Standalone Access Control User Manual

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

INSTALLATION GUIDE BioEntry W2 English Version 1.00 EN BEW2 V1.00A

Fingerprint Access Control F1. User Manual

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

User Manual. EMC compliance Ltd. FCC TEST REPORT Report No.: EMC-FCC-R0170

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

iface Series Installation Guide

Operation manual For NG BIOSINGLE Version 1.1

INSTALLATION GUIDE BioStation L2 English Version 1.00 EN BSL2 V1.00A

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

GV-AS Controller. Installation Guide

INSTALLATION GUIDE Xpass S2 English Version 2.2 EN XPS2 V2.20A

C5S120 Installation and Connection Guide

INSTALLATION GUIDE BioStation 2 English Version 1.3 EN BS2 V1.30A

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

iclock Access control Installation

REX F-0-9 Standalone or Access Controller

CM-110SK Standalone Keypad Installation Instructions

TFT screen Fingerprint Machine

Waterproof. Keypad/Reader/Controller

Fingerprint Access Standalone User s Manual

SCR100 User Manual. Version:1.1 Date:Dec 2009

iclock serial Time & Attendance and Access Control Terminal Installation Instructions

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

F & SC Serial Access Control Station. Installation Guide

GV-Card Reader. User s Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

EL-ST100 KEYPAD CONTROLLER

_ Access control SISTEMAS DE SEGURIDAD

User Manual. Split access control with intelligent secured power supply.

Fingerprint Door Lock OPERATOR S MANUAL

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

B100-SA Standalone Biometric Reader

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

BIO-PRO Standalone / Weigand fingerprint reader

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

M5 User Manual (V1.0)

3.2 No records found though staff have clocked in/out The machine cannot connect with PC Clock s time works fine, but FP scanner

Click Save to return to the main Setup screen.

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

GV-RK1352 and GV-R1352 Card Reader

Installation Instruction

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com

Innovative Fingerprint Terminal Installation Guide

GV-AS200 Controller. Hardware Installation Guide

Quick Start Guide. GV-CS1320 Camera Access Controller

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

Installation Instructions (KF-2000)

User Manual. PCKeypad Wireless Keypad

GV-AS/EV Controller. User s Manual

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

Fingerprint Door Lock User MANUAL

Installation Instructions 4291 and 4292 Keypads

Two Door Controller GEN-045

Installation & User Manual

Pegasus Equipments Export Limited. Local Contact:

Installation Guide & User Manual. FR1300 Version: Date: November, 2014

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Connecting a Cisco Input Module

Installation & User Manual V2.08

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

Access control panel U-Prox IC E (Elevator control)

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Fingerprint Access Control Card Reader User s Manual

GV-AS/EV Controller. User s Manual

DOLXFD1000B. Waterproof Access Control/Reader

Transcription:

www.zkaccess.com

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection PC RS485 Connection FR1200 RS485 Connection Relay Connection Digital Input Connection Weigand Input Connection Weigand Output Connection Installation Reference Specifications Electrical Specifications 1 03 04 07 09 11 12 13 14 15 17 18 19 21 24 25 26 29 31

Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully before installation. Do not install the device in an area subject to direct sunlight, humidity or dust Do not place a magnet near the product. Magnetic field from magnets, CRT, TV, monitor or speaker may damage the device. Do not place the device next to heating equipment. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it 2 Do not let children touch the device without supervision.

Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully before installation. Do not drop the device. Do not disassemble, repair or alter the device. Do not use the device for any other purpose than specified. Do not damage the device In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. 3 Contact your nearest dealer in case of a trouble or problem.

4 How to Place a Finger ZkTeco s fingerprint readers will give optimal results for fingerprint matching if the following recommendations and suggestions are followed. Select a finger to enroll It is recommended to use an index finger or a middle finger. Thumb, ring or little finger are relatively difficult to place in the correct position How to place a finger on a sensor Place a finger such that it completely covers the sensor area with maximum contact. Place core of the fingerprint at the center of the sensor. The core of a fingerprint is a center where the spiral of ridges is dense. Usually core of fingerprint is the opposite side of the lower part of a nail. Place a finger such that the bottom end of a nail is located at the center of a sensor. If a finger is placed as shown in the right, only a small area of a finger is captured. So it is recommended to place a finger as shown on the left.

5 How to Place a Finger Tips for different fingerprint conditions ZKTeco s fingerprint products are designed to verify fingerprints with highest security irrespective of the conditions of the skin of the finger. However, in case a fingerprint is not read on the sensor, please refer to the followings tips. If a finger is stained with sweat or water, scan after wiping moisture off. If a finger is covered with dust or impurities, scan after wiping them off. If a finger is way too dry, please blow some warm air from your mouth on the finger tip. Tips for fingerprint enrollment In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place the finger correctly with utmost care. In case of low acceptance ratio, the following actions are recommended. Delete the enrolled fingerprint and re-enroll the finger. Enroll the same fingerprint again. Try another finger if a finger is not easy to enroll due to scar or cuts. In case of an enrolled fingerprint cannot be used due to injury or if the hand is full, it is recommended to enroll more than two fingers per user.

6 How Does Reader work Register finger Identification Feature extraction Open door Thank you! Verified successfully Verify feature Door closed Please try again! Verification failed Fingerprint database Event logs Create Stored

7 Basic Contents Product Contents Screw Driver 1 pc. Wall Mounting Screws 3 pcs. Wall Plugs 3 pcs Star-shape Screw for Mounting Plate -2 pcs Mini-USB Cable -1 pc Software CD 2 pin, 5 pin, 7 pin, 10 pin cables each 1 pc Mounting Paper TF1700 Installation Guide

8 Optional accessories Product Contents Weigand Card Reader FR1200 Slave Fingerprint Reader 12VDC, 3A Power Adaptor K1-1 Exit Button RS485 Convertor Prox Card

9 Product PIN Diagram Front View Side View OLED Screen 3 x 5 Keypads Doorbell/LED USB-host Reset ZK Fingerprint Reader

10 Product PIN Diagram Bottom View Back View Star-shaped screw hole for fixing reader to the back plate Tamper switch (Magnetic Contact) Cables and Connectors

11 Product Dimension 62.5mm (2.46in.) 65mm (2.56in.) 185mm (7.28in.) 185mm (7.28in.) 132mm (5.20in.) 41.5mm (1.63in.)

Cables and Connectors Aux. input and Relay output 1 10 Weigand input and Power out 1 7 Weigand Output and RS485 1 5 Ethernet 1 4 Power In 12 1 2

13 Mounting the reader on the Wall Stick the mounting template on the wall and make holes as per the markings. Mount the rubber gasket and the back plate on the wall with the help of the supplied screws. 1 2 Mount TF1700 terminal on the Back plate Secure the TF1700 by fixing two screws at the bottom. 3 4

14 Power Connection PIN PIN DESCRIPTION WIRE 1 +12V DC RED 2 GND BLACK UPS (Optional) DC Power Supply 12V DC (Red) GND (Black) Recommended power supply Regulated 12VDC, 1A Comply with standard IEC/EN 60950-1. To power other devices from the power supply of TF1700, use a power supply with higher current rating.

15 Ethernet Connection Ethernet Connection PIN PIN DESCRIPTION WIRE 1 RJ45-1 YELLOW 2 RJ45-2 GREEN 3 RJ45-3 RED 4 RJ45-6 BLACK TCP/IP TCP/IP

15 Ethernet Connection Direct connection with PC To connect TF1700 with a PC directly, connect both devices with a straight CAT-5 cable. As the TF1700 supports auto MDI/MDIX feature, it is not necessary to use a crossover cable. PIN PIN DESCRIPTION WIRE 1 RJ45-1 YELLOW 2 RJ45-2 GREEN 3 RJ45-3 RED 4 RJ45-6 BLACK TCP/IP

17 PC RS485 Connection PC RS485 Connection PIN PIN DESCRIPTION WIRE 1 WD0 GREEN 2 WD1 WHITE RS232 3 GND BLACK 4 485+ BLUE 5 485- YELLOW RS485- RS485+ GND Important Notes Do s and Dont s for RS485 connection 1. RS485 communication wires should be a shielded or twisted pair cable. RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflection during communications. 2. Adjust the communication speed as needed, The signal quality vary depending on wiring conditions, and it maybe necessary to lower the baudrates. 3. The GND Signal may be omitted if and only if the GND potential difference is less than ±5V

18 FR1200 RS485 Connection PC RS485 Connection Power Supply PIN PIN DESCRIPTION WIRE 1 WD0 GREEN 2 WD1 WHITE 3 GND BLACK 4 485+ BLUE 5 485- YELLOW GND +12V GND 485+ 485- Weigand Out RS485- RS485+ GND Menu -> Options-> Access Options-> 485Reader -> 485Reader (Master) 1 2 3 4 1.Steps to activate the master and salve functionality between TF1700 and FR1200 as shown in the diagram on the left. 2. There are six DIP switches on the back of FR1200, Switches 1-4 is for RS485 address, switch 5 is reserved, switch 6 is for reducing noise on long RS485 cable. 3. If FR1200 is powered from TF1700 terminal,the length of wire should be less than 100 meters or 330 ft. 4. If the cable length is more than 200 meters or 600 ft., the number 6 switch should be ON as below 5.If the 485Reader set as Salve, it will be used as inbio-series reader, check page 28 to know more. Distance More than 200 meters

19 Lock Relay Connection For Normally Open Lock PIN PIN DESCRIPTION WIRE 1 NO1 BLUE 2 COM1 RED 3 NC1 YELLOW 4 NO2 ORANGE 5 COM2 GREEN 6 BELL- PURPLE DC Power Supply - + Electric Strike 7 BELL+ BROWN 8 SEN WHITE 9 GND BLACK 10 BUT GARY + - (1) (2) NO1 (BULE) COM1 (RED)

20 Lock Relay Connection For Normally Closed Lock PIN PIN DESCRIPTION WIRE 1 NO1 BLUE 2 COM1 RED 3 NC1 YELLOW 4 NO2 ORANGE 5 COM2 GREEN 6 BELL- PURPLE DC Power Supply - + Electric Strike 7 BELL+ BROWN 8 SEN WHITE 9 GND BLACK 10 BUT GARY + - (2) (3) COM1 (RED) NC1 (YELLOW)

21 Aux. Input Connection PIN PIN DESCRIPTION WIRE 1 NO1 BLUE 2 COM1 RED 3 NC1 YELLOW 4 NO2 ORANGE 5 COM2 GREEN 6 BELL- PURPLE 7 BELL+ BROWN 8 SEN WHITE 9 GND BLACK 10 BUT GARY Exit Button Door Sensor (8) (9) (10) SEN GND BUT (WHITE) (BLACK) (GARY)

22 Aux. Output Connection PIN PIN DESCRIPTION WIRE 1 NO1 BLUE 2 COM1 RED 3 NC1 YELLOW 4 NO2 ORANGE 5 COM2 GREEN 6 BELL- PURPLE DC Power Supply - + Alarm 7 BELL+ BROWN 8 SEN WHITE 9 GND BLACK 10 BUT GARY (4) (5) NO2 (ORANGE) COM2 (GREEN)

23 Aux. Output Connection PIN PIN DESCRIPTION WIRE 1 NO1 BLUE 2 COM1 RED 3 NC1 YELLOW 4 NO2 ORANGE 5 COM2 GREEN 6 BELL- PURPLE DC Power Supply - + Door Bell 7 BELL+ BROWN 8 SEN WHITE 9 GND BLACK 10 BUT GARY (6) (7) BELL- BELL+ (PURPLE) (BROWN)

24 Weigand Input Connection PIN PIN DESCRIPTION WIRE 1 +12V RED 2 GND BLACK 3 INWD1 WHITE 4 INWD0 GREEN 5 RLED BLUE 6 GLED GARY 7 BEEP PURPLE DC+(6-14V) GND WD1 WD0 (1) (2) (3) (4) +12V (RED) GND (BLACK) INWD1 (WHITE) INWD0 (GREEN) Green LED Beeper (6) (7) GLED (GARY) BEEP (PURPLE) RFID Reader

25 Weigand Output Connection PIN PIN DESCRIPTION WIRE 1 WD0 GREEN 2 WD1 WHITE 3 GND BLACK 4 485+ BLUE 5 485- YELLOW 0 1 (1) (2) (3) (4) (5) WD0 (GREEN) WD1 (WHITE) GND (BLACK) 485+ (BLUE) 485- (YELLOW) Access Control Panel

26 Installation Reference Standalone Reader Installation LOCK Door Sensor Exit button Alarm Door

27 Installation with C3 Panel Third Party Controller Weigand Output Connection Weigand Output Weigand Output Weigand Output Weigand Output LOCK LOCK Outside Door Door Sensor Inside Door Inside Door Door Sensor Outside Door

28 Installation with inbio Panel inbio-series Controller RS485 Connection EXT RS485 EXT RS485 EXT RS485 EXT RS485 LOCK LOCK Outside Door Door Sensor Inside Door Inside Door Door Sensor Outside Door

29 Specification Item Specification Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform CPU Memory Fingerprint Sensor Display LED Indicator Communication Weigand signal Identification speed FAR ZEM720 ZK 6001, 400Mhz 128MB Flash, 32MB SDRAM ZK optical sensor 128*64 OLED screen Red, Green Ethernet(10/100M), RS485, USB-HOST, Wiegand Input and Wiegand Output 1 sec 0.0001% FRR 1% Operating Temperature -10 C~50 C(14 F~50 F) Operating Humidity 20%-80% Language Power Supply Access control interfaces Dimension English, Spanish, Portuguese, French, Thai and many more 12V DC, 3A Electric lock, alarm, exit button, wired door bell 62.5*185*41.5mm (L*W*D)

Electrical Specification Min. Typ. Max. Notes Working power supply Voltage(V) 9.6 12 14.4 Use regulated DC power adaptor only Current(A) 2 Electronic lock relay output Switching voltage(v) 36V Use regulated DC power adaptor only Switching Current(A) 2 Switch Aux. input VIH (V) VIL (V) TBD TBD Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors WEIGAND Input Voltage(V) 10.8 12 13.5 Current(mA) 500 TTL/WEIGAND Output VoH (V) 5 VoL (V) 0.8 Pull-up resistance (Ω) 4.7K The output ports are open drain type, pulled up with 4.7k resistors internally ZK Electronic lock Voltage(V) 10.8 12 13.2 Current(mA) 500 30

Troubleshooting 31 Fingerprint can not be read or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly wet cloth. If a fingerprint is way too dry, blow on the finger and retry. Fingerprint is verified but authorization keeps failing. Check whether the user is restricted by group or time zone. Check with administrator whether the enrolled fingerprint has been deleted from the device for some reason. Authorized but door does not open. Check whether the lock duration is set to appropriate minutes which opens the lock. Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit. Why device display system broken and the alarm is ringing. Check whether the device and back plate are securely connected to each other. If not, a tamper switch is activated which triggers the alarm and keeps it ringing.

Copyright 2013 ZKTeco Inc. All right reserved. ZKTeco may, at any time and without notice, make changes or improvements to the product and services offered and/or cease production or commercializing them. ZK USA Office: 201 Circle Drive North, Suite 116 Piscataway, NJ 08854, USA Tel: +1 732-412-6007 Fax +1 732-412-6008 sales@zkaccess.com zkaccess.com Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry for the product, please contact ZKACCESS.