modunet292: novanet-ethernet interface

Similar documents
Sauter Systems

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

I/O module, digital outputs (open collector), modu551

I/O module, analogue outputs and universal inputs

EY-EM : Remote I/O module, ecolink

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

EY-RU : Room operating unit, ecounit

I/O module, digital outputs (relays), modu550

EY-SU 358: Push-button unit for room operating unit, ecounit358

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

modu : Local override and indicating units

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-RU 355: Room operating unit, ecounit355

I/O module, digital and universal inputs, modu530

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

I/O module, universal, digital, S0 inputs, modu533

EYE 200: DDC single-room controller, ecos200

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

PLC PFC200 Controller PFC200 CS 2ETH RS

ecounit : Room operating unit with EnOcean wireless technology

HEC. General Operating, Maintenance and Installation Manual

PXR11 PXR12. System controllers DESIGO PX

Extension module for graphic Web functions for one automation station

EY-RC 208, 209: Room automation stations, ecos208, 209

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Manual operation and local visualisation. with SAUTER EY-modulo.

Content. Product Description

Extension module for Web functions generic

Extension module for BACnet over Ethernet / IP and graphic Web functions

PAS 300, PROFIBUS Slave Interface Module

ES-313 ETHERNET TO SERIAL DEVICE SERVER Ethernet 2 Port RS422/485

RTU560 Remote Terminal Unit Connections and Settings

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH

Manual Industry Interfaces

M-Bus Central Unit. Use

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

OnRISC. OnRISC Baltos ir 2110

IPC194. ipconv Protocol Converter

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

ES-413 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 2 Port RS422/485 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

CPC 01/02. Description. x86 Computer Module. Datasheet

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

ES-446 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 1 Port RS232 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES.

IP gateway, MDRC IG/S 1.1, GH Q R0001

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Short Instructions CG-S / IP-Router

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Installation and Configuration Guide

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

F1000 User's Manual. (Version: V1.01)

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

BACnet/IP Web Interface

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

SK CU4-EIP-C Part number:

Modular controllers CECX

IntesisBox Modbus Server Panasonic

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

SK CU4-PNT-C Part number:

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

FieldServer X-25 Start-Up Guide

JetBox 9300/9310 User Manual. Hardware

5.2 CP0201, CP0291, CP0292

IntesisBox Modbus Server Fidelio IP

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

R70 Ethernet to CAN interface Manual (1.4 EN)

Product and Applications Description

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

LVX Control Unit. Features:

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision


SAUTER EY-modulo. Compatibility for a secure investment.

Quick Start Installation Guide

DF PROFI II PC/104-Plus

ES-257 ETHERNET TO SERIAL DEVICE SERVER Ethernet 2 Port RS232

TM221CE24R controller M IO relay Ethernet

UK +44 (0) // USA // JAPAN //

User Manual. cmt-svr Startup Guide

NetBiter Serial Server User Manual

TM221CE40R controller M IO relay Ethernet

ED-549. Ethernet to Analogue In ED-549. Connect, Configure, Control ED-549 ETHERNET TO ANALOGUE 8 INPUTS

SK TU4-CAO-C Part number:

User Manual. cmt-svr Startup Guide

TM251MESC controller M251 Ethernet CAN

R60 USB to CAN interface Manual (1.4 EN)

SW-504 Industrial Unmanaged Ethernet Switch 4 Ports

Feature and Benefits. Certifications

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

UK +44 (0) // USA // JAPAN //

Transcription:

SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation of EY-modulo 2 and EY3600 stations via -based internet protocol. Access device for management-level software and all SAUTER novapro visualisations and OPC servers. Features Bus access device for system bus with interface To integrate stations (EY3600, EY-modulo 2) in IP networks based on (LAN/WAN) For SAUTER CASE Suite applications To download programmes onto the stations For SAUTER novapro visualisations For remote monitoring via Internet Part of the SAUTER EY-modulo 2 system family TCP/IP communication Communication with 2-wire system bus Technical description Power supply: 230 V~, 115 V~ Mounted on DIN rail (F001), desktop model (F002) a/b plug (F001), RJ-11 (F002) for RJ-45 plug for 10 Base-T (10 MBit/s) Fixed IP addressing RS-232 interface for parameterisation and updating 5 LEDs for Error, Send, Power, Activity, Link Products Type Description Weight (kg) EY-BU292F001 - interface (MCC model) 0.65 EY-BU292F002 - interface (desktop model) 0.70 Technical data Electrical supply Installation Power supply 230 V~ +10%, -15%, Dimensions W x H x D (mm) 115 V~ +10%, -15% (50/60 Hz) F001 193 131 41 Power consumption 6 VA, < 7 W F002 228 131 41 Weight (kg) Interfaces, communication F001 0.65 F002 0.70 F001 1 a/b terminals F002 1 RJ-11 socket Standards, guidelines and directives 1 RJ-45 socket Type of protection IP 00 (EN 60529) 10Base-T 10 MBit/s Protection class I (EN 60730-1) Serial interface 1 DB-9 (male) CE conformity as per RS-232 to DTE (57k6, 8n1) EMC Directive 2004/108/EC EN 61000-6-1 EN 61000-6-2 Standard settings EN 61000-6-4 TCP/IP address 192.168.10.20 Directive 2006/95/EC EN 60950-1 Subnet mask 255.255.255.0 Software class A EN 60730-1 annexe H TCP port (App 1) 51806 (nova292-server) TCP port (App 2) 51807 (nova291 emulation) Additional information Fitting instructions P100002338 Permitted ambient conditions Material declaration MD 96.015 Operating temperature 0...45 C (32...113 F) Storage and transport temperature -25...70 C (-13...158 F) Dimension drawing Humidity 10...85 % rh F001 M10445 no condensation F002 M10448 Wiring diagram F001 A10543 F002 A10544 www.sauter-controls.com 1/5

Accessories Type Description Software GZS100F599 292 driver software, current version on CD (CASE Tools DVD) 1) Connecting cable 0367862001 RJ11 RJ11, 1.5 m 0367862002 RJ11 RJ11, 2.9 m 0367862003 RJ11 RJ11, 6.0 m 0367842002 RJ45 RJ45, 1.5 m 0367842003 RJ45 RJ45, 2.9 m 0367842004 RJ45 RJ45, 6.0 m 0386301001 Serial cable for firmware update and software reset (DB 9) 0386507001 crossover RJ45 RJ45, 3 m General 0374509001 Power supply connector, 3-pin (supplied with F001) 001024005 Cable housing for 0374509001, cable tension relief 0374677001 Installation kit for 2-DIN rail mounting (for F001) 1) DVD must be ordered separately or can be obtained from the extranet. Function The can be used for various tasks and applications, such as: 1. Access unit for including CASE Monitor (for time programmes): The is an access unit for for parameterising and programming EY-modulo 2 and EY3600 automation stations (modu, nova), compact controllers (moduflex, novaflex) and room controllers (ecos). The runs as a nova292 server. Up to five s can use a at the same time. 2. Interface for novapro32, novapro Open, novapro and OPC server: The can be used together with the additional Windows novavport driver as a 291 router. For novapro visualisation, the EY3600 driver is configured for the novavport virtual COM-port driver. The runs as a nova291 emulation. Up to six novavport drivers can be set up on one computer. However, only one EY3600 driver can communicate from novapro via novavport with a. 3. Interface for novamit29x for monitoring and inspecting the system bus. Notes on operation: The nova291 emulation of cannot emulate a 291 router in dial-up mode (no remote operation [router] and no remote monitoring [routel] via analogue/isdn modem). The is ideal for laptops and PCs that do not have a serial interface or an ISA slot. An interface is needed on the computer for this purpose. The applications can also be run in parallel. A located in the motor control centre enables the technician to connect into the system with CASE and, for example, to make FBD modifications or check bus loads without having to disconnect the higher-level management system (such as novapro ). (Topology c) 2/5 www.sauter-controls.com

Topologies The following network topologies are supported by the : a) Directly at PC with crossover cable ("PTP") b) With supply line and one /hub c) With supply line and two es/hubs novamit29x Crossover Notes on topologies: The more es or hubs there are fitted in the network, the longer are the times needed to transmit the telegrams on the network. Experience shows that the PC network still works well with 'ping times' of about 30 ms. There should be no telegram time-outs on the network. For the, which is always used together with an application on the PC, it is advisable to structure the network in such a way that the integration of process data, i.e. the communication between PC and, is carried out in 'isolation'. When installed in an MCC with type EY-BU292F001, it is also advisable to fit a small so that a service technician has access on site. More information on these notes and the supported topologies can be found in the help file that is installed with the 292 software. Wiring a) : With the link from the to an automation station, the maximum extended network time constant should not exceed 120 µs. This means that a segment of a modunet cable can have a maximum time constant of 30 µs. (max. 300 / 200 nf) Note: When using a, a resistor of 1000 (1/4 Watt, 10%) is required. If it does not exist, it should be fitted at a position between a and b in the in order to reduce the interference from incorrectly-fitted communication subscribers (e.g. due to inadequate earthing) or from wiring that is susceptible to interference. b) : The connection of the is a 10Base-T connection and can be used with standard cables, preferably CAT-5. 10Base-T (IEEE 802.3i) runs via four cores (two twisted pairs) of a CAT-3 or CAT-5 cable. A hub or is in the middle and has one port for each subscriber. The transmission speed is 10 Mbit/s and the maximum length of any segment is 100 metres. c) Serial interface: The serial interface on the, as an item of data terminal equipment (DTE), is laid out as follows:- Pin 2: Pin 3: Pin 5: Pin 7: Pin 8: Pins 1, 4, 6, 9: RD (Receive Data: line which receives one data bit) TD (Transmit Data: line which sends one data bit) GND (Ground: "earth", reference potential to 0 V) RTS (Request To Send:device indicates something is to be sent) CTS (Clear To Send: ready to send) NC (Not connected: not used) The connection with a PC COM interface can be made using a serial null-modem cable (accessory no.: 0386301 001) For further information, consult the fitting instructions, P100002338. Hardware : The - interface is available in two different versions. Type EY-BU292F001 is designed for fitting to a top-hat rail (EN 60715) in an MCC in a plant. Type EY-BU292F002 is a desktop variant of the. Normally used in training centres, by commissioning engineers or service technicians etc. The unit has an interface (RJ-45, 10Base-T) and a interface (a/b plugs as screw-type plug-in terminals on the EY-BU292F001, RJ11 plugs on the EY-BU292F002). There is a serial interface (DB-9, male) available for firmware updates, support purposes and for carrying out an IP reset of the configuration. The unit can run on either 230 Volt~ (50 Hz) or 110 Volt~ (60 Hz) power supplies. On type EY-BU292F001, the power supply is via a screw-on plug, while type EY-BU292F002 has a square connector with three slits for the mains, and an ON/OFF. In operation, the unit has a power consumption of max. 7 Watt. The is an embedded Linux platform based on a Samsung ARM7 processor (S3C44B0; 66MHz) and has 16 Mbyte flash PROM and 16 Mbyte DRAM. Various LEDs are provided to indicate the status of the unit. www.sauter-controls.com 3/5

LED display and diagnostics Designation Colour Status (speed) Inactive Denotes Operating correctly Flashing In the start-up phase Ready for use after approx. 30 seconds Error Red Flashing: To indicate an operating fault: Every 1 No novavport communication second (flashes after is interrupted for about 30 seconds) No telegrams ( Receive Rx) Every ¼ second Yellow Active Sending a telegram ( Send Tx) Power Green Flashing Device ed on (mains power present) Activity Green Active Receiving (Rx-Receive) and sending (Tx-Transmit) an telegram Link Yellow Active connection established (physically) and connection to network or network card of the PC. 292 software The 292 software is supplied with CASE Suite or novapro32 for CASE Suite. However, the latest 292 software can be downloaded as a single installation from the SAUTER Extranet. Furthermore, a Tools-DVD containing the 292 software is available to order (accessory no.: GZS100F599). Minimum PC requirements: CPU clock speed: 800 MHz (more recommended) RAM: 256 MB (more recommended) Hard disk memory: 1 GB (more recommended) Installation of the 292 software requires about 9.5 MB interface with cross-over cable Serial interface (or standard USB-COM converter) for firmware updates Operating system requirements: Windows XP Pro., Server 2003 (recommended with Service Pack).NET-Framework 2.0 Further details on the installation of the 292 software, on the 292 Configurator and the novavport virtual COM-Port driver can be found in the help file (292.chm). The latest help files (in German, French and English) are installed and can also be downloaded from the Extranet. Dimension drawing EY-BU292F001 EY-BU292F002 131 M10445 M10448 4/5 www.sauter-controls.com

Wiring diagram EY-BU292F001 L RJ 45 DB 9 RS232 b a b a A10543 EY-BU292F002 ON/ OFF I O RJ 11 6/6 RJ 45 DB 9 RS232 b a 54321 A10544 Printed in Switzerland Fr. Sauter AG Im Surinam 55 CH-4016 Basle Tel. +41 61-695 55 55 Fax +41 61-695 55 10 www.sauter-controls.com info@sauter-controls.com www.sauter-controls.com 71960150035/5 02