Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Similar documents
Operating Manual. English. Digital-Analog Converter DACON8-UMB.

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

General Operating, Maintenance and Installation Manual

MINI MCR-SL-PT100-UI(-SP)(-NC)

Manual Industry Interfaces

FL MC 2000E (SM40) LC

MINI MCR-SL-UI-2I(-SP)(-NC)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

LVX Control Unit. Features:

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Hardware Manual RM CANview

PHOENIX CONTACT - 07/2006

MINI MCR-SL-PT100-UI-200

HEC. General Operating, Maintenance and Installation Manual

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

MINI MCR-SL-UI-REL(-SP)

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

is then retained absolutely without interruption.

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

MINI-PS AC/10-15DC/8

CPCI-PS24 24V-Power Supply

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Channel Switch CS. General Operating, Maintenance and Installation Manual

PHOENIX CONTACT - 10/2009

Serial PROFIBUS Interface

Installation & Configuration manual. InduBox GSM IV

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Modbus TCP/RTU Gateway

SoundwebTM. Installation Guide

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

GT- IRDM-9603 Product description Rev. 2 17/06/2014

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

PXR11 PXR12. System controllers DESIGO PX

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

EX-RC1 Remote I/O Adapter

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

TRIO-DIODE/12-24DC/2X10/1X20

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

MGate 4101-MB-PBS Series

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Serial/Ethernet Converter

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Media Converters. Media Converters. Product Selection Guides

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

AI561 Analog Input Module

Extension module for BACnet over Ethernet / IP and graphic Web functions

AO561 Analog Output Module

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

AS-i Safety Relay Output Module with Diagnostic Slave

MC 11 EB-2 Power supply cabinet with external bus, AC version

GS202 Encoder Switch

DI561 Digital Input Module

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Manual Fiber Optic Interfaces

ICF-1150 Series Quick Installation Guide

Technical Information Fieldgate SFG500

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Assembly instruction / User manual

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Hardware Manual RM CANview Gateway

QUINT-BUFFER/24DC/24DC/40

F1000 User's Manual. (Version: V1.01)

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Communication module to connect M-bus devices to POL6xx.xxx controllers.

DI572 Digital Input Module

MINI MCR-SL-MUX-V8-FLK 16

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PHOENIX CONTACT - 01/2007

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

Operating Manual IRS31-UMB Intelligent Road Sensor Order No.: 8510.Uxxx

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Transcription:

Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1

TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION... 11 INSTALLATION AND COMMISSIONING... 14 TROUBLESHOOTING... 17 MAINTENANCE AND CARE... 18 DISPOSAL... 18 MANUFACTURER... 18 EC CERTIFICATE OF CONFORMITY... 19 Version history: Version Date Compiled by Comments V1 15.09.2006 EES/SH 1 st edition V2 05.04.2007 EES EC Certificate of Conformity supplemented; grounded DIN rail V3 17.09.2010 EES changed picture 2 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Please read before use Before using the equipment, please read the operating manual carefully and follow the instructions in every detail. Safety instructions Installation and commissioning must only be carried out by suitably qualified specialist personnel. Never take measurements on or touch live electrical parts. Only mount the module on the DIN rail when the power is switched off. Protect the device from direct sunlight The equipment requires an adjustment period of several minutes on being moved to a location with different climate conditions. Pay attention to the technical data and storage and operating conditions. Designated use The equipment must only be operated within the range of the specified technical data. The equipment must only be used under the conditions and for the purposes for which it was designed. The safety and operation of the equipment can no longer be guaranteed if it is modified or adapted. Guarantee The guarantee period is 24 months from the date of delivery. The guarantee is forfeited if the designated use is violated. G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 3

Symbols used Important indication concerning possible hazards to the user Important indication for the correct functioning of the device 4 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Description The UMB ISO Converter (ISOCON) is an intelligent interface converter with electrical isolation for building UMB networks. The devices are easily installed on standard EN mounting rails and networked together by means of mounting rail bus connectors. The 24V feed for the power supply takes place via the bus connector. Two, 6 pole DIP switches are provided in the device for configuration of the ISOCON. Features 3-way gateway with half-duplex RS485 interface for the UMB sensors, RS232 interface for the host system and firmware updates and half-duplex RS485 interface for networking the converters together Easy mounting on standard EN mounting rails Easy networking of up to 32 subscribers via mounting rail bus connectors 24V DC power supply suitable for switchgear cabinets 12V power supply (electrically isolated) for the sensors 24V power supply for sensors ESD protection for all interfaces Easy configuration with DIP switches Functions displayed via LED s Low space requirement; width approx. 23mm/module Low energy consumption / dissipation G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 5

Summary RS485 Sensor Interface (SS3-1) Sensor Voltage Output 12V/24V (SS3-2) Power Supply & RS485 Bus Interface RS232 Interface Status LED s Sensor Voltage Output 12V/24V (SS3-2) RS485 Sensor Interface (SS3-1) 6 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

RS232 9 pole SUB-D socket Pin Designation Description 1 n.c. Not used 2 TxD Transmit data 3 RxD Receive data 4 DTR *1) DEE operational readiness 5 GND Operational earth 6 DSR *1) Operational readiness 7 CTS Readiness to transmit 8 RTS Switch on transmission 9 RI Ring signal *1) Pins 4 and 6 are internally bridged. This connection serves to connect the UMB network to the host system. As the UMB system works according to the master-slave principle, only one master may be connected on a UMB network. The RS232 interface is configured via DIP switch DIP1. G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 7

Sensor Power Supply and RS485 Sensor Connection SS3-2 Pin 1: +12V Switchable electrically isolated power supply for all 12V sensors Pin 2: GND1 Electrically isolated earth for all 12V sensors Pin 3 +24V Switchable power supply for all 24V sensors Pin 4: GND2 Earth for all 24V sensors SS3-1 Pin 1: A 2 wire RS485 A Pin 2: B 2 wire RS485 B Pin 3: A 2 wire RS485 A, internally bridged with Pin 1 Pin 4: B 2 wire RS485 B, internally bridged with Pin 2 A terminator of approx. 120 Ohms is recommended between terminals A & B on long lines (>300m). 8 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Mounting Rail Bus Connector Earth 24V Power Supply, Feed Earth 24V Power Supply, Feed +24V Power Supply, Feed B1, Internal Bus A1, Internal Bus NOTE: The assembly must take place on a grounded DIN rail! G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 9

Status LED s There are 2 LED s on the front side of the device in order to display the correct configuration and functioning of the ISOCON. Their meanings are as follows: Red LED: - If this LED lights up permanently after switch-on there is a configuration fault. Check the DIP switch - If this LED lights up during operation, the reset function for interrupting the sensor power supply is activated. Green LED: - This LED flashes briefly (20ms) every 10 seconds to display the function of the device. - If this LED lights up for a longer period (>500ms), data is being received from the connected sensor. 10 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Configuration In order to configure the device, unscrew the top of the housing on the left and right (see Ill. 1). Pull the printed circuit board out of the housing until the end stop. Set the desired configuration on both DIP switches (see Ill. 2), in accordance with the following tables for DIP1 and DIP2. Next close the housing (housing top and bottom sections must engage together) and install the ISOCON on the mounting rail bus connector. Static discharge can damage electronic equipment. Discharge the electrical charge of your body before opening and configuring the equipment: To do this, touch an earthed surface, e.g. the metal housing of the control panel. fig. 1: Unscrew housing top fig. 2: DIP switch G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 11

DIP 1 The host communication can be configured with the aid of DIP switch DIP1. Meaning DP1 DIP Switch 1 2 3 4 5 6 Factory Setting *1) OFF OFF OFF OFF OFF OFF 1200 Baud *2) ON OFF OFF X X OFF 2400 Baud *2) OFF ON OFF X X OFF 4800 Baud ON ON OFF X X OFF 9600 Baud OFF OFF ON X X OFF 19200 Baud ON OFF ON X X OFF 38400 Baud OFF ON ON X X OFF 57600 Baud ON ON ON X X OFF Host Comm. RS232 X X X OFF OFF OFF Host Comm. RS485/2D X X X OFF ON OFF Watchdog RS232 *3) X X X ON OFF OFF Diagnostic mode, for internal use only 1) Host communication: RS232, baud rate 19200 baud 2) Firmware updates for the USB sensors are not possible at these baud rates X X X X X ON 3) If the Watchdog RS232" function is activated, the ISOCON monitors the data traffic on the RS232 interface. If there is no data enquiry for more than 45 minutes, the12v/24v output is reset in accordance with DIP2. This function can be used to reset a modem, for example. 12 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

DIP2 DIP Switch DIP2 can be used to activate various modes which contribute to data security. The table provides a summary of the various settings. Meaning DP2 DIP Switch 1 2 3 4 5 6 Factory Setting *1) ON ON ON ON ON ON Automatic Routing *2) OFF x x x x ON Reset Function 12V *3) x OFF x x x ON Reset Function 24V *4) x x OFF x x ON Diagnostic Mode, for internal use only 1) 12V/24V reset functions activated. 2) Function not currently available. x x x x x OFF 3) Switches the 12V power supply on/off cyclically if communication with the sensor is not possible. 4) Switches the 24V power supply on/off cyclically if communication with the sensor is not possible. X : any desired setting possible G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 13

Installation and Commissioning 1. First configure all the modules in accordance with your requirements. 2. Clip the required number of mounting rail bus connectors onto the DIN rail and then connect all the ISOCON modules. 3. Connect one UMB sensor to each ISOCON module. Pay attention to the different voltage ranges (12V/24V) of the UMB sensors and the correct polarity on the power supply and bus connection. 4. Now connect the 24V power supply to the mounting rail bus connectors. 5. Connect your host system to any desired RS232 interface of an ISOCON or to the RS485 interface of an additional ISOCON converter. Please note that, in this case, the host communication of this ISOCON converter must be set to RS485/2D. The equipment is now ready for operation. ATTENTION: Only mount or remove modules from the DIN rail when the power is switched off The assembly must take place on a grounded DIN rail! Connecting the ISOCON modules to the DIN rail 14 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Technical Data Power supply Power supply 24VDC +/- 10% Power consumption < 50mA at 24V; excluding sensor Connection Phoenix bus connector, gold, 5 pole Function display Green LED, flashes every 10 seconds RS232 interface Transmission type Configuration Transmission rates Transmission length Connection Protocol-transparent, 8 data bits, 1 stop bit, no parity DIP switch 1200, 2400, 4800, 9600, 19200, 38400, 57600 baud 0... 15 m, from 38400 baud max. 5 m recommended 9 pole SUB-D socket RS485 Interface Sensor Standard RS485 2 wire, half-duplex Transmission type Protocol-transparent, 8 data bits, 1 stop bit, no parity Tri-State 2 bit after stop bit edge Transmission rate 19200 baud Transfer size 0... 1200 m, twisted pair, screened Function display LED green on data reception, on for approx. 0.5 s Connection COMBICON plug-in connector 0.2 2.5 mm² (AWG 24 12) G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 15

RS485 interface internal bus Standard RS485 2 wire, half-duplex Transmission type Protocol-transparent, 8 data bits, 1 stop bit, no parity Tri-State 2 bit after stop bit edge Transmission rate 19200 baud Connection Phoenix bus connector, gold, 5 pole, maximum 8A Sensor power supply 12 V output max. 150 ma, electrically isolated 24 V output max. 2 A (observe the maximum current of the internal bus) Storage conditions Permissible ambient temp. -40... 70 C Permissible rel. humidity 0... 95% RH (non-condensing) Operating conditions Permissible operating temp. -30... 60 C Permissible rel. humidity 0... 95% RH (non-condensing) Housing Material PA-V0, green Width x Height x Depth 22.5 x 99 x 118.6 mm Protection class IP20 Weight approx. 120 g Connections COMBICON plug-in connectors 0.2 2.5 mm² (AWG 24 12) 16 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Troubleshooting Description Red LED permanently lit Red LED lights briefly Cause / Correction - Check DIP switch setting - Sensor connected incorrectly G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 17

Maintenance and Care The product is designed in such a way as to require no maintenance. It does not contain any parts (e.g. batteries) requiring maintenance or exchange. Disposal The device must be disposed of in accordance with European Directives 2002/96/EC and 2003/108/EC (waste electrical and electronic equipment). Waste equipment must not be disposed of as household waste! For environmentally sound recycling and the disposal of your waste equipment please contact a certified electronic waste disposal company. Manufacturer For matters of guarantee or repair please contact: G. Lufft Mess- und Regeltechnik GmbH Gutenbergstraße 20 D-70736 Fellbach Postfach 4252 D-70719 Fellbach Germany Tel: +49(0)711-51822-0 Fax: +49(0)711-51822-41 E-mail: info@lufft.de 18 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

EC Certificate of Conformity Product: Type: UMB ISO Converter ISOCON UMB (Part No.: 8160.UISO) We herewith certify that the above mentioned equipment complies in design and construction with the Directives of the European Union and specifically the EMC Directive in accordance with 89/336/EC and the Low Voltage Directive in accordance with 73/23/EC. The above mentioned equipment specifically conforms to the following EMC Standards: EN 61000-6-2:2005 Part 6-2: Generic Standards - Immunity for industrial environment EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 ESD RF Field Burst Surge Conducted RF Magnetic Field 50Hz EN 61000-6-3:2001 Part 6-3: Generic standards - Emission standard for residental, commercial and lightindustrial enviroments EN 55022:1998 +A1:2000 +A2:2003 Conducted Interferences pren 50147-3:2000 Radiated Emission Fellbach, 27.03.2007 Axel Schmitz-Hübsch G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 19