VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Similar documents
WARNING ELECTRICAL SHOCK HAZARD

Installation Guide VLT Programmable I/O MCB 115

WARNING ELECTRICAL SHOCK HAZARD

Installation Guide VLT BACnet/IP MCA 125

Installation Guide VLT PROFIBUS DP MCA 101

Installation Guide VLT DeviceNet MCA 104

Installation Guide VLT EtherNet/IP MCA 121

CI-tronic Reversing contactor Type RCI

ENGINEERING TOMORROW. User Guide. BACnet MS/TP Communication with MBS UBR-01 Router. VLT HVAC Drive FC 102 VACON 100 HVAC. vlt-drives.danfoss.

Installation Guide Modbus TCP Module

Redundancy unit CP-A RU

115/230 VAC Digital Input Module OHDI-01

Installation Guide EtherNet/IP Module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating Guide FC Series Add-On Instruction for VLT EtherNet/IP MCA 121

(Catalog Numbers 1394-FK10TS and -FK22TS)

Operating instructions. Switching amplifier DN0210 DN / / 2015

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

High Power Electronic Gear Installation and operation Guide

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Installation Guide PROFINET Module

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

24/48/120 VAC Interface Card Instruction Manual

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Table of Contents Product Overview Before using the product Installation Procedure... 5

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

MINI-PS AC/10-15DC/8

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Operating instructions. Speed monitor D / / 2014

Chameleon Stand-alone

PV Rapid Shutdown device

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

P216 Series Condenser Fan Speed Controller

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Options for ABB drives. User s manual FSE-31 pulse encoder interface module

Analog Monitor Installation Manual

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Installation Instructions

QUINT-BUFFER/24DC/24DC/40

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Installation Guide EtherNet/IP Module

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Power supply CP-E 24/0.75 Primary switch mode power supply

BACnet/IP Web Interface

MAXIMA+ Series Rotary Level Indicator

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

DeviceNet ArmorBlock Network Powered 16-input Module

FREQUENCY CONVERTER FC101 (QUICK GUIDE)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

The VLT Micro Drive Small drive maximum strength and reliability

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

VLT 8000 AQUA. Installation. Mechanical installation

PHOENIX CONTACT - 07/2006

MAXIMA + Series ROTARY LEVEL CONTROL

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

DSE2548 LED expansion module INTRODUCTION

Analog Input Installation Manual

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Power supply CP-C 24/5.0

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

CompactLogix Power Supplies Specifications

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

PanelView 600 Terminals

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

S66 Series Electronic Fan Speed Control

Operating Guide VLT AutomationDrive FC 302

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Modulating controlled actuator AME 11

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Introduction. Features. Applications DR45 SERIES AC SINGLE PHASE OUTPUT DIN RAIL MOUNT SSRS PRODUCT SELECTION

Revision to the Operating Instructions

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

Revision. Drive System for Decentralized Installation Fieldbus Interfaces, Field Distributors * _0717*

ArmorPoint I/O Field Potential Distributor, Series A

Transcription:

These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar with the instructions and safety measures described in the VLT Midi Drive FC 280 Operating Guide. Ordering Numbers Description MCC 107 for VLT Midi Drive FC 280 K1S2 1) MCC 107 for VLT Midi Drive FC 280 K2S2 1) MCC 107 for VLT Midi Drive FC 280 K1T4 1) MCC 107 for VLT Midi Drive FC 280 K2T4 1) MCC 107 for VLT Midi Drive FC 280 K3T4 1) Table 1.1 Ordering Numbers Ordering number 134B5466 134B5467 134B5463 134B5464 134B5465 1) K1 K3 is 3 enclosure sizes of VLT Midi Drive FC 280. S2 represents 1x200 240 V. T4 represents 3x380 480 V. For VLT Midi Drive FC 280 T4, only H1 version is optimized to operate with the EMC filters installed. Tools Required SZS 0.6x3.5 mm slot screwdriver for EMC filter terminals. Safety Instructions WARNING DISCHARGE TIME The frequency converter contains DC-link capacitors which can remain charged even when the frequency converter is not powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time after power has been removed before performing service or repair work can result in death or serious injury. Stop the motor. Disconnect AC mains and remote DC-link supplies, including battery back-ups, UPS, and DC-link connections to other frequency converters. Disconnect or lock PM motor. Wait for the capacitors to discharge fully. The minimum waiting time is specified in Table 1.2. Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors are fully discharged. Voltage [V] Power range Minimum waiting time [kw (hp)] (minutes) 200 240 0.37 2.2 (0.5 3) 4 380 480 0.37 7.5 (0.5 10) 4 Table 1.2 Discharge Time Danfoss A/S 05/2017, Rev. 02, All rights reserved. MI07L102

Product Overview Number of phases 1 3 Illustration 1.1 and Illustration 1.2 show the typical circuit diagram of the EMC filters. Illustration 1.1 Circuit Diagram for 1-phase EMC Filter Rated voltage [V] 1x200 240 ±10% 3x380 480 ±10% Rated frequency [Hz] 50 60 EMC filter ordering number 134B5xxx 466 467 463 464 465 Frequency converter enclosure size K1S2 K2S2 K1T4 K2T4 K3T4 Rated current in [A] 11 15 5 11.6 16 Power loss [W] 6.0 9.1 3.8 9.4 12.4 Maximum leakage 0 0 187 124.8 124.8 current [ma] 1) Maximum leakage current [ma] 2) 0 0 19.5 13 13 High-voltage test 2100 Line-neutral 2780 Line-line [V-] 2700 Line-case 2780 Line-case Table 1.4 Technical Data 1) Calculated for maximum line voltage tolerance, by loss of 2 phases (typical @ 50 Hz). 2) Maximum allowed voltage fluctuation in accordance with IEC 38 ±10%. Illustration 1.2 Circuit Diagram for 3-phase EMC Filter Table 1.3 and Table 1.4 show the operating conditions and technical data of the EMC filters. Enclosure protection rating Ambient temperature Climatic category Type of cooling Operating conditions Derating > 50 C (122 F) Derating > 1000 m (3281 ft) IP20 50 C (122 F) 25/085/21 [in accordance with EN 60068-1] Ambient natural air Continuous -3% / K 5% / 1000 m (3281 ft) Table 1.3 Operating Conditions 2 Danfoss A/S 05/2017, Rev. 02, All rights reserved. MI07L102

Mechanical Installation The EMC filters support 2 mounting styles. Footprint installation Side-by-side installation Footprint installation 1. Mount the EMC filter on the wall, and mount the frequency converter on the EMC filter. Fasten with recommended screws. Refer to Illustration 1.3. Side-by-side installation 1. Mount the frequency converter and the EMC filter on the wall side by side, and fasten with recommended screws. Refer to Illustration 1.4. 1 Frequency converter 1 Frequency converter 2 EMC filter 3 Recommended screws: 4 pieces M5 screws 4 Recommended screws (length: 10 20 mm/0.39 0.79 in): 4 pieces M4 screws for K1T4/K1S2, or 4 pieces M5 screws for K2T4/K2S2/K3T4 2 EMC filter 3 Recommended screws: 4 pieces M4 screws for K1T4/K1S2, or 4 pieces M5 screws for K2T4/K2S2/K3T4 4 Recommended screws: 2 pieces M5 screws Illustration 1.4 Side-by-side Installation Illustration 1.3 Footprint Installation MI07L102 Danfoss A/S 05/2017, Rev. 02, All rights reserved. 3

Electrical Installation 1. Connect the cables and fasten the screws as shown in Illustration 1.5 and Illustration 1.6. Refer to Table 1.5 for the tightening torque of EMC filter terminals. 1a 1b 1c 1d 1e 1f Connect the EMC filter mains output cable to the frequency converter mains input terminal block (terminals N (91) and L (92) for single-phase, or terminals L1 (91), L2 (92), and L3 (93) for 3-phase). Connect the frequency converter mains input terminal block to the frequency converter mains input. Secure the cable with the cable clamp. WARNING ELECTRICAL HAZARD Touching the wires of the mains input while they are not switched off can result in death or serious injury. Before continuing, use an appropriate voltage measuring device to make sure that the mains input is switched off. Ensure that the mains input cannot be switched on by a third party, while you are working. Connect the wires of the EMC filter mains input cable to the EMC filter mains input terminal block (terminals N (91) and L (92) for single-phase, or terminals L1 (91), L2 (92), and L3 (93) for 3-phase). Connect the EMC filter mains input terminal block to the EMC filter mains input. Connect the ground wire of the EMC filter mains input cable to the EMC filter PE terminal. 1 Frequency converter 2 EMC filter 3 Cable connecting the frequency converter with the motor 4 EMC filter PE terminal 5 EMC filter mains output cable 6 EMC filter mains input cable 7 EMC filter mains input terminal block 8 Cable clamp 9 Frequency converter mains input terminal block Illustration 1.5 Cable Connections for Footprint Installation 4 Danfoss A/S 05/2017, Rev. 02, All rights reserved. MI07L102

1 Frequency converter mains input terminal block 2 Cable connecting the frequency converter with the motor 3 Cable clamp 4 EMC filter mains output cable 5 EMC filter mains input cable 6 EMC filter mains input terminal block 7 EMC filter PE terminal 8 EMC filter 9 Frequency converter Illustration 1.6 Cable Connections for Side-by-side Installation Mains input terminal PE terminal 0.5 0.8 Nm (4.4 7.1 in-lb) 2.0 2.5 Nm (17.7 22.1 in-lb) Table 1.5 Tightening Torque for EMC Filter Terminals EMC filter ordering number 466 467 463 464 465 134B5xxx Frequency converter enclosure size K1S2 K2S2 K1T4 K2T4 K3T4 Input [mm 2 (AWG)] 3x4 (12) 1.5 0.75 4 (12) (16) (18) 1.5 (16) 4 (12) Cable length for L1 /L2 /L3 (L1 /N ): 280±5 Output [mm 2 (AWG)] mm (11.0±0.2 in). Cable length for PE terminal: 220±5 mm (8.7±0.2 in). Mains input terminal M3 PE terminal M4 Table 1.6 Specifications for EMC Filter Terminals MI07L102 Danfoss A/S 05/2017, Rev. 02, All rights reserved. 5

Mechanical Data EMC filter ordering number 134B5466 134B5467 134B5463 134B5464 134B5465 Frequency converter enclosure size K1S2 K2S2 K1T4 K2T4 K3T4 Dimensions A [mm (in)] 250 (9.8) 312.5 (12.3) 250 (9.8) 312.5 (12.3) Dimensions a1 [mm (in)] 234 (9.2) 303 (11.9) 234 (9.2) 303 (11.9) Dimensions a2 [mm (in)] 19.5 (0.77) 21.3 (0.84) 19.5 (0.77) 21.3 (0.84) Dimensions am [mm (in)] 198 (7.8) 260 (10.2) 198 (7.8) 260 (10.2) Dimensions B [mm (in)] 75 (2.95) 90 (3.54) 75 (2.95) 90 (3.54) 115 (4.53) Dimensions b1 [mm (in)] 55 (2.17) 70 (2.76) 55 (2.17) 70 (2.76) 90 (3.54) Dimensions bm [mm (in)] 60 (2.36) 70 (2.76) 60 (2.36) 70 (2.76) 90 (3.54) Dimensions C [mm (in)] 50 (1.97) Dimensions c1 [mm (in)] 22.7 (0.89) Dimensions D1 [mm (in)] Ø5.3 (Ø0.21) Dimensions Dm [mm (in)] M4 M5 M4 M5 Dimensions e1 [mm (in)] 6.5 (0.26) 5 (0.20) 6.5 (0.26) 5 (0.20) Dimensions f1 [mm (in)] 10 (0.39) 12.5 (0.49) Dimensions fm [mm (in)] 7.5 (0.30) 10 (0.39) 7.5 (0.30) 10 (0.39) 12.5 (0.49) Mounting screws for EMC filter M5 Mounting screws for frequency converter M4 M5 M4 M5 Weight [kg (lb)] 1.10 (2.43) 1.50 (3.31) 1.20 (2.65) 1.90 (4.19) 2.10 (4.63) Illustration 1.7 Mechanical Data Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss A/S Ulsnaes 1 DK-6300 Graasten vlt-drives.danfoss.com 130R0801 MI07L102 05/2017, Rev. 02, *MI07L102*