DtS Data Migration to the MSA1000

Similar documents
Configuring the MSA1000 for Linux or NetWare Environments

Upgrading the MSA1000 for Enhanced Features

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

Fully integrated and tested with most ProLiant servers and management software. See list of servers with each adapter specifications.

QuickSpecs. Models HP SC11Xe Host Bus Adapter B21. HP SC11Xe Host Bus Adapter. Overview

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.5. Overview. Retired

QuickSpecs SmartStart TM Release 6.0

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)

hp StorageWorks modular SAN array 1000 Compatibility Matrix Checkmarks Microsoft indicate hyperlinks to following pages

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

QuickSpecs HP StorageWorks Modular Smart Array 20

QuickSpecs. Models ProLiant Cluster F200 for the Entry Level SAN. Overview

QuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview

QuickSpecs. Models. Overview

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

QuickSpecs. HP SANworks Storage Resource Manager. Overview. Model HP SANworks Storage Resource Manager v4.0b Enterprise Edition.

Rack-mountable 14 drive enclosure with single bus, single power supply. Tower 14-bay drive enclosure, single bus, single power supply, LCD monitor

HP D6000 Disk Enclosure Direct Connect Cabling Guide

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP StorageWorks Modular Smart Array 1500 cs application note

Microsoft Windows Server 2008 On Integrity Servers Overview

HPE ProLiant Gen9 Troubleshooting Guide

Disaster Recovery Guide for Windows 2008 and RHEL 5.x platforms with external disk support

QuickSpecs. What's New New 146GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive. HP SCSI Ultra320 Hard Drive Option Kits (Servers) Overview

HP StorageWorks Data Protector Express ProLiant Edition 3.1 SP4. Overview

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

QuickSpecs. Models. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes

Smart Array Controller technology: drive array expansion and extension technology brief

HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

HP StorageWorks Using the QLogic HBA driver for single-path or multi-path failover mode on Linux systems application notes

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP BladeSystem Matrix Compatibility Chart

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

HP MSA Family Installation and Startup Service

QuickSpecs. What's New. Models. Overview

QuickSpecs. HP StorageWorks 60 Modular Smart Array. Overview

HP Data Protector A disaster recovery support for Microsoft Windows 7 and Windows Server 2008 R2

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Retired. Currently shipping versions:

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

RAID-01 (ciss) B Mass Storage Driver Release Notes

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide

Marvell BIOS Utility User Guide

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

HP 20 Modular Smart Array Overview

QuickSpecs. HPE Library and Tape Tools. Overview. Features & Benefits. What's New

QuickSpecs. What's New. Models. Overview

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

HP ProLiant ML370 G4 Storage Server

Hot-Pluggable SCSI Hard Drive Compatibility A Word About Compaq Disk Drives Fault Prediction Quality Performance Integration

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP Storage Manager User Guide. May 2005 (First Edition) Part Number

My First SAN solution guide

QuickSpecs. PCIe Solid State Drives for HP Workstations

HP integrated Citrix XenServer 5.0 Release Notes

HPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape

Support Notes for Red Hat Enterprise Linux ES v.4.6 for HP Integrity Servers

Key results at a glance:

Available Packs and Purchase Information

HP Serviceguard for Linux Certification Matrix

QuickSpecs. HP StorageWorks ds2110. HP StorageWorks ds2110. Description HP StorageWorks Disk System 2110 (ds2110)

HP Supporting the HP ProLiant Storage Server Product Family.

QuickSpecs. Models. Key Features. Overview. Retired

Quick Setup & Getting Started

Installing Windows Vista TM Business on HP Compaq Business 4400, 6300, 7300, 7400 notebook models

Data Protector Express Hewlett-Packard Company

HP StorageWorks Continuous Access EVA 2.1 release notes update

QuickSpecs. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter. Overview. Retired

QuickSpecs HP Insight Rapid Deployment software 6.0

HP StorageWorks Modular Smart Array Family. Simple, reliable and cost-effective storage solutions

HPE RDX Utility Version 2.36 Release Notes

QuickSpecs. HP 50 Modular Smart Array Enclosure. Overview

HP ProLiant Storage Server iscsi Feature Pack

README.TXT

Configuring RAID with HP Z Turbo Drives

HP Library and Tape Tools 4.20 Release Notes

Transcription:

White Paper September 2002 Document Number Prepared by: Network Storage Solutions Hewlett Packard Company Contents Migrating Data from Smart Array controllers and RA4100 controllers...3 Installation Notes and Prerequisites:...3 Data Drive Migration Steps:...3 Considerations...6 Appendix...7 Migration Prerequisites and Migration Limitations...7 MSA1000 fallback to RA4100 or Smart Array controllers...9 DtS Data Migration to the MSA1000 Abstract: This white paper outlines step-by-step procedures for data migration from Direct Attach Storage on Smart Array Controllers and RA4100 controllers to the MSA1000. DtS Architecture Data Migration Direct Attach Storage (DAS) to SAN (DtS) architecture is an exclusive Hewlett Packard feature that provides a quick and easy way to migrate stored data protected by Smart Array and RA 4100 controllers to a StorageWorks MSA1000 storage system. Data stored on one-inch universal disk drives (Ultra2 and Ultra3) using newer Smart Array controllers and data stored on RA4100 storage systems can be migrated to the StorageWorks MSA1000. Following a step-wise procedure, you simply remove the drives from the older systems and insert them into the MSA1000. Existing data, RAID sets, and configuration information will remain intact allowing data migration to be completed in minutes, not hours. Key features and benefits of DtS architecture include: Instant consolidation of DAS into a SAN environment DtS creates an upgrade path from Smart Array and RA4100 controlled drives and data to a SAN environment Simple redeployment of DAS to SAN environment for growth management and capacity utilization Supports up to 42 drives and 32 volumes HP Array Controllers that support DtS are: Smart Array 3100ES Smart Array 3200 Smart Array 4200 Smart Array 4250ES Smart Array 431 Smart Array 5i Smart Array 532 Smart Array 5312 Smart Array 5300 RA 4100 Controllers

DtS Migrations Linux 2 Notice 2002 HP Computer Corporation HP, StorageWorks, Smart Array, SupportPaq, and the HP logo are trademarks of Hewlett Packard Company. Other product names mentioned herein may be trademarks of their respective companies. HP shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided as is without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.

DtS Migrations Linux 3 Migrating Data from Smart Array controllers and RA4100 controllers The following steps illustrate the migration from direct attached storage to the HP MSA1000 all controlled by the same Host server. IMPORTANT: It is recommended that you record the current configuration of all arrays and note which drives are part of each array prior to performing the migration. If you need to fall back to your former configuration, you will be required to re-enter all array and volume information. Installation Notes and Prerequisites: Hardware: As the HP FCA2214 HBA is an industry standard PCI adapter; it should work in all PCI compliant slots, regardless of server vendor. During the qualification and testing phase for both the HP FCA2214 HBA and the HP Modular SAN Array 1000, several different server vendor hardware platforms were tested - including models from IBM and Dell. Refer to the compatibility matrix for more details on multi-vendor x86 platform support. Software: Operating System levels for the host computers are: Linux Red Hat 2.1 Advanced Server, Linux Red Hat 7.2 Professional, and Linux SuSE SLES. For configuration of the HP MSA1000, Microsoft Internet Explorer v5.0 (or above) with the Microsoft Virtual Machine update is required. Kernel source must be installed for the driver installation to complete. If kernel source is not installed, please see your vendor s documentation for steps on installing it Refer to the Appendix for more detailed information on Migration Prerequisites and Migrations Limitations. Data Drive Migration Steps: 1. Back up and verify all data on the drives to be migrated to tape or disk. 2. Note and record the current configuration of all arrays and note which drives are part of which array. This can be done in Array Controller Utility (ACU) by highlighting one of the arrays and noting the drives that are flashing on the current SCSI array unit. 3. Power down the server. 4. Install the HP FCA2214 HBA in the server slot and attach the fiber optic interconnect component for appropriate communication to the MSA1000. Interconnect drawings are shown on the HP StorageWorks Modular SAN Array 1000 Installation Overview poster that was shipped with the MSA1000. Ensure that all interconnect components are in place for proper communication from the FCA2214to the MSA1000. 5. Power on your server and run the server vendor's BIOS setup utility. Use the BIOS setup utility to perform the vendor-specific tasks required to install the adapter (if applicable). Save the configuration, and perform a reboot of the server. 6. Log on as root and mount the MSA1000 Support Software CD for NetWare / Linux. 7. Create a temporary directory for the HBA source code. 8. Navigate to the \HBA\LINUX directory on the CD.

DtS Migrations Linux 4 9. Copy msainstall to the temporary directory. 10. Extract the contents of the FCA2214 HBA driver source to the temporary directory using the following command: # tar xvzf qla2x00src-v6.0.1.tgz C <dir> where <dir> is the path and name of the temporary directory created above. 11. Navigate to the temporary directory. 12. Run the provided script to rebuild a new kernel for use with the driver by entering: #./msainstall -b This script will compile a new kernel image, which allows Linux to detect the MSA1000 Controller and its configured LUNs. Without it, only the MSA1000 Controller will be recognized. The boot loader will be configured to boot to this new kernel. This process may take awhile. 13. Once this has completed, you will need to reboot. Eject the MSA1000 Support Software CD for Netware / Linux and reboot. 14. One the system s OS is backup up, log on as root again. 15. To load the driver, type: # insmod qla2300 NOTE: The install process does NOT put the HBA drivers in the startup scripts or in initrd. If this is desired, it will have to be done manually. 16. Shut down the Server and its attached storage (if it is external). 17. Physically migrate the drives from the existing arrays (for example, RA4100 or Smart Array controllers) to the MSA1000. Drive order is not important although it is recommended that drives be moved to the same bay position in the new unit. Note and record the locations of the drives and their corresponding arrays in case that information is needed for later use. 18. Make sure all drives are fully seated in the MSA1000 and power it on. When the startup process of the MSA1000 is complete, the following message displays: 01 COMPAQ MSA1000 STARTUP COMPLETE 19. Scroll back through the messages on the MSA1000 display and verify that the number of volumes (arrays) you intended to migrate are detected. This can be verified by the message: 120 Configured Volumes: X (where X is the number of volumes migrated/detected) 20. After the MSA1000 reports the correct number of migrated volumes, power on your server. 21. As the Operating System loads, most of the volumes should mount based on etc/fstab settings. If necessary, perform the command # mount a Which will mount all volumes listed in etc/fstab. However, you may want to modify etc/fstab so these volumes will mount automatically. If etc/fstab is modified to mount the volumes (changing from Smart Array or RA4100 to MSA1000). Make a copy of etc/fstab (such as etc/fstab.old) in case a fall back is needed to the old controller see Fall Back section

DtS Migrations Linux 5 22. The volumes should now be mounted and controlled by the MSA1000.

DtS Migrations Linux 6 Considerations If multiple servers are accessing a single StorageWorks MSA1000, best practices would dictate that you enable SSP (Selective Storage Presentation). SSP is an access control feature that allows multiple hosts running multiple applications on the SAN to have controlled access to MSA1000 storage on the SAN. This selective access allows policies to be set to determine which servers can access which storage, down to a logical volume level. For more Information, please read: MSA1000 User Guide MSA1000 SAN Configuration Guide

DtS Migrations Linux 7 Appendix Migration Prerequisites and Migration Limitations The Smart Array 5304 and 4200 controllers have 4 channels that can control up to 4 external chassis. While the MSA1000 also has 4 channels, only two are available external as two are used for the internal 14-drive shelf. If migrating from a Smart Array 5304 or 4200 to an MSA1000, only three of the channels can be migrated to a single MSA1000. The fourth channel will have to be migrated to a second MSA1000. Please Note: Once the drives have been migrated to the MSA1000, you cannot fall back to the Smart Array controller and have the controller recognize the array / volume structures. The RAID Information Service (RIS) will be overwritten by the MSA1000, and the Smart Array controller cannot interpret it to recreate the array and volume structure ALL DATA WILL BE LOST. All arrays and volumes controlled by either a Smart Array controller or an RA4100 controller must be moved during the migration process. The DtS Architecture does not support a partial migration. Furthermore, do not attempt a server consolidation or operating system upgrade during the migration. Perform the DtS Migration first, verify that all volumes are available, perform and verify another Full Backup, then carry on with the server consolidation or operating system upgrade. Do not attempt a migration if one of the drives is marked as FAILED. Replace the failed drive, and let the array rebuild before the migration. Do not attempt a migration if there are unconfigured drives in either the MSA1000 or attached StorageWorks Enclosures (Model 4314R / 4354R). These drives must either be configured or removed from the chassis for the migration to occur successfully. If you are migrating from multiple Smart Array controllers or RA 4100 s, migrate one Smart Array controller or RA 4100 at a time. Move the drives or the drive shelf, and power on the MSA1000. Ensure that the MSA1000 (after full power up) detects the appropriate number of volumes. Power down the MSA1000, and migrate the next set of Smart Array / RA 4100 controlled drives or drive shelf. Again ensure that the MSA1000 (after full power up) detects the appropriate number of migrated volumes. Please note and record drive and shelf location as well as array configurations (via ACU) before the migrations. If migrating from an RA 4100 to the MSA1000, there will be two open drive slots. These slots can be filled with more drives, and a separate logical volume created on them. If you have spare drives configured in your arrays, you may have to reassign the spare to your array (via HP ACU) after the migration procedure. In certain cases, Selective Storage Presentation (SSP) may have to be reconfigured when migrating from an RA4100 to the MSA1000. Secure Path is not supported by the MSA1000 in an external boot (SAN boot) environment.

DtS Migrations Linux 8 Dual Bus vs. Single Bus Drive Enclosures If you are migrating a dual bus drive enclosure that enclosure will occupy both external SCSI buses on the HP MSA1000. Please ensure which models you are migrating from and plan accordingly prior to the migration. Supported enclosures include the following HP models: StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the MSA1000) 190209-001 190209-B31 (Int l) 190209-291 (Japan) StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the MSA1000) 190211-001 190211-B31 (Int l) 190211-291 (Japan)

DtS Migrations Linux 9 MSA1000 fallback to RA4100 or Smart Array controllers Follow these steps to restore your former configurations (HP Smart Array controlled volumes or HP RA 4100 controlled volumes) from the MSA1000: 1. Modify etc/fstab (back to original rename if saved) 2. Install drivers for legacy controller 3. Power down the server. 4. Remove the FCA2214 HBA. 5. Install the legacy controller (either the HP StorageWorks 64-bit/66-Mhz Fibre Channel Host Adapter or the HP Smart Array controller). 6. Migrate the disk drives back to the legacy RA 4100 or Smart Array controller, taking care to restore the drives to their position prior to the migration. 7. Power up the server. 8. After the reboot, you must reassign and recreate the Array and Volume information through HP Array Configuration Utility (ACU). 9. The legacy controller will not be able to read the restored Array and Volume information correctly. Therefore, you MUST enter the Array and Volume information EXACTLY as it was set up before the migration to the MSA1000 via HP ACU. This is why it is imperative that you note and record the Array information and Volume information PRIOR to performing the migration. 10. A reboot of the server may or may not be required.