Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Similar documents
Total Modular Data Centre Solutions

Thermal management. Thermal management

Rack cooling solutions for high density racks management, from 10 to 75 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Precision Cooling Mission Critical Air Handling Units

Switch to Perfection

Industry leading low energy evaporative fresh air cooling.

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Liquid Cooling Package LCP Cooling Systems

IT Air Conditioning Units

Ecotel Free Cool 5-15kW

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Liquid Cooling Package LCP Cooling Systems

Precision Cooling. Precision Cooling Advantages

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

SmoothAir Modular Precision Cooling

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Rittal Cooling Solutions A. Tropp

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Efficiency of Data Center cooling

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Overcoming the Challenges of Server Virtualisation

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. DCL up to 35 kw. Modular Rack Cooling

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

ENCLOSURE HEAT DISSIPATION

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Close-coupled cooling

RE Series Rack from Eaton Product Presentation

Reliability and extended operation

LCP Hybrid Efficient performance with heat pipe technology

How to Increase Data Center Efficiency

Liebert PCW. Cool the Cloud

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

MSYS 4480 AC Systems Winter 2015

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Liebert PDX from 15 to 120 kw

2018 Product overview

High Efficient Data Center Cooling

Data Center Energy Savings By the numbers

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

The Shared Data Centre Project

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Liebert HPM from 4 kw to 100 kw

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

A separate CRAC Unit plant zone was created between the external façade and the technical space.

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Scalable, Secure. Jason Rylands

Power and Cooling for Ultra-High Density Racks and Blade Servers

Rittal LCP T3+ High-availability IT cooling with no compromise

One Stop Cooling Solution. Ben Tam Business Development Manager

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Close Coupled Cooling for Datacentres

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

APC APPLICATION NOTE #146

Liebert PDX from 15 to 120 kw

Ecoflair Air Economizers

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

CL20 Rear Cooler. New Generation Computer Room Cooling

Liebert DCW CATALOGUE

Welcome Association of Energy Engineers to the Microsoft Technology Center

MEASURE MONITOR UNDERSTAND

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Green IT and Green DC

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Reducing Data Center Cooling Costs through Airflow Containment

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

HIGH EFFICIENCY Central Chiller

Data Center Optimized Controls

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Transcription:

Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres

Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how to achieve data centres goals and ambitions. 2 PR-2014-0005-GB Subject to modification R4-05/2016

Data centres are expanding and improving Do not let your climate limit you DencoHappel are involved and experienced in a wide variety of industries; from cooling towers and large volume air handlers to office-based comfort cooling. We use this vast pool of knowledge to supplement our extensive history within the industry to continually design, innovate, redesign and improve our products to enable your operations to thrive. Data centre design is no longer conventional or singular. With an industry focused on greater efficiency and productivity, techniques and innovations such as pre-fabrication, modular design, aisle containment and many others now have a larger prevalence. These new innovations sometimes present challenges for the cooling and control of the air. Our close control range, called DENCO Products, is created in harmony with these innovations to achieve your desires. The designs can address your requirements, whether that would be data centre redesign, need for scalability, highest performance or maximised use of freecooling. The best data centres managers not only have to account for the present demands of their site, but they also plan and prepare for any number of future demands. They need equipment that can account for today, tomorrow and the next 10 to 20 years. DENCO products are devised with this in mind by utilising EC technology, inverter compressors or other variable technologies so that they only work as hard as your servers. All these aspects help to improve the metrics that you view your data centre performance against and also help your PUE value progress towards to 1. A trusted, experienced supplier: Decades of experience in close control industry Large variety within product portfolio Components with the latest technology Efficiency focused design Simple system integration and combination In-house maintenance and service capabilities With international locations of factories, sales offices, contacts and support, we can be wherever you, your data or your site is located. PR-2014-0005-GB Subject to modification R4-05/2016 3

Key Features: Rear to front airflow with multiple configurations available: no raised floor or suspended ceiling required for airflow leaving plenty of space for your services. Direct expansion (R410A) and chilled water variants available. White panels to improve room illumination, black panels are available as an option. Hot Swap fan technology: replaceable even during operation. Row-DENCO Meeting your future demands, today The data centre industry is no longer static; designers and managers must consider both the existing requirements for performance and output. They must predict the future for the data centre. They need scalability, adaptability, dependability, consistency and simplicity to allow for their data centre to grow and evolve efficiently. Scalable Row-DENCO is small, effective and due to its airflow design, it can be grouped with sets of servers. This allows you to order and install just in time for your data centre s growth and with multiple airflow configurations, it can grow in any direction. Adaptable Row-DENCO is a highly adaptable method for expansion of an existing data centre. The design requires no floor or ceiling void and has a small footprint (between 0.30 and 0.36 m²). It includes easy and simple connection points that allow for fast installation from either above or below. 4 PR-2014-0005-GB Subject to modification R4-05/2016

Slim design Electronic expansion valve Graphics based display SHR = 1 Small footprint High EER Inverter compressors EC Fans Dependable Row-DENCO is easy for finding space for an N+1 configuration. The units can be networked together, allowing for a duty-standby configuration setup. The fans, as standard, operate an internal running redundancy, therefore if a fan needs replacing, the others can increase their speed to cover the cooling requirement whilst you can perform a hot swap. Consistent Row-DENCO is available as both direct expansion and chilled water units, but share the same design principles and features: mechanical connections available at the top and bottom, humidifier available for both, casing sizes and airflow configurations are the same for both types. Simple Row-DENCO units make the delivery, installation, commissioning and maintenance as straight-forward as possible. Whether by using integrated wheels to give easy positioning on your site or good accessibility to all internal components for maintenance. Row-DENCO, by design, helps lower risks to the room s performance with each airflow localised to particular servers. PR-2014-0005-GB Subject to modification R4-05/2016 5

Accessories available: Humidifer Dual power supply Interface cards Water leakage detection Smoke detection Floor clamping kits Flexible water connections Shut off valves Power transducer Compressor sound attenuation 6 PR-2014-0005-GB Subject to modification R4-05/2016

Row-DENCO Technical Data Direct Expansion Cooling & Power 051 071 121 Total cooling duty 1 kw 10.63 16.59 28.62 Sensible cooling duty kw 9.61 15.67 27.37 EER kw 3.43 3.1 3.2 Power consumption 3 kw 3.10 5.31 8.95 Airflow m 3 /h 1500 2700 4200 No. of circuits 1 1 1 Weight and Dimensions Height mm 2100 2100 2100 Width mm 300 300 300 Depth mm 1000 1000 1000 Weight 4 Kg 175 190 193 Chilled water Cooling & Power 020 025 035 036 Total cooling duty 2 kw 16.14 20.52 24.60 20.95 Sensible cooling duty kw 16.14 20.52 24.60 20.95 Water pressure drop kpa 14 21 29 55 Power consumption 3 kw 0.51 0.68 0.86 0.86 Airflow m 3 /h 2520 3360 4200 4200 No. of circuits 1 1 1 2 Weight and Dimensions Height mm 2100 2100 2100 2100 Width mm 300 300 300 300 Depth mm 1000 1000 1000 1000 Weight 4 Kg 190 193 195 205 Direct Expansion Limitations Max inlet temperature C 40 Min inlet temperature C 23 Max inlet relative humidity 5 % 53 Min inlet relative humidity 6 % 20 Max outdoor temperature (Standard) C 45 Min outdoor temperature (Standard) C -20 Max outdoor temperature (Winter kit) C 45 Min outdoor temperature (Winter kit) C -35 Chilled Water Limitations Max inlet temperature C 55 Min inlet temperature C 16 Max inlet relative humidity 5 % 82 Min inlet relative humidity 7 % 7 Max water inlet temperature C 16 Min water inlet temperature C 6 Max temperature difference C 10 Min temperature difference C 3 We reserve the right to make technical modification without prior notice. 1 Return air conditions: 35 C / 27 % RH and 35 C ambient 2 Return air conditions: 35 C / 27 % RH and 10 / 15 C water temperature. 3 Power consumption for compressor (if applicable), fans outdoor (if applicable) and fans indoor 4 Weight is an approximation and representative of the 1000 mm deep configuration only 5 At 23 C air inlet temperature 6 At 40 C air inlet temperature 7 At 55 C air inlet temperature PR-2014-0005-GB Subject to modification R4-05/2016 7

What you need, only when you need it Direct and scalable Designed to be considerate for the future By placing a Row-DENCO unit amongst or alongside your servers, it allows for a shorter air path which helps increase the number of air exchanges per hour and allows for a higher temperature gradient. Scalability is a key benefit of Row-DENCO. Data centre designs may evolve and expand, Row-DENCO allows for incremental increases in cooling requirements. 8 PR-2014-0005-GB Subject to modification R4-05/2016

Unit configuration and air paths To suit your needs Front Discharge Left and Right Discharge Front discharge is possible using either a 1,000 mm casing or 1,200 mm casing (shown above). Warm air is drawn from the hot aisle and then cold air is delivered directly out of the front of the unit, allowing for the air to diffuse back to the servers. Left and right discharge uses a 1,200 mm deep case. As the Row- DENCO unit extrudes into the cold aisle, the air is delivered across the face of the servers through grilles on the side panels. The front door has no grille, therefore the air is forced horizontally. Left Discharge Right Discharge Left discharge uses a 1,200 mm deep case. It is similar to the left and right discharge design except with one grille is blocked. Typically these designs would be used for the end of a server rack. Right discharge uses a 1,200 mm deep case. It is similar to the left and right discharge design except with one grille is blocked. Typically these designs would be used for the end of a server rack. PR-2014-0005-GB Subject to modification R4-05/2016 9

Supporting your cooling requirements Outdoor units A condensing unit would perfectly compliment your direct expansion indoor unit. It comes with inverter driven hermetic scroll compressors that use R410A to provide excellent energy saving. Part load operations represent 75 % of operation time, therefore being able to operate relative to this demand provides excellent energy efficiency when compared to traditional ON/OFF technology. Other equipment includes filter drier, oil separator, sump heater, EC fans (optional) and anti-vibration mounts (optional) to ensure a quiet, smooth and efficient operation. Winter start kits are available to enable operation as low as -35 C. Condensing unit Condensing Units Data Power 051 071 121 Fan power consumption 1 kw 0.31 0.60 1.20 Compressor power consumption 1 kw 2.63 4.56 7.19 Airflow m 3 /h 6400 8640 15768 Weight and Dimensions Height mm 1240 1200 1700 Width mm 900 1450 1450 Depth mm 420 550 550 Weight 2 mm 108 190 255 We reserve the right to make technical modification without prior notice. 1 Max power consumption 2 Net weight approximation; may vary depending on options selected We have a vast portfolio of products that can support your system. Whatever you require; indoor or outdoor installation, air or water based cooling, with a cooling capacity range from 4.9 kw to 2,749 kw, we can offer a wide range of models with or without heat pumps and complimented with an extensive variety of accessories. Chiller Our chillers are distinguished by their great potential for energy saving. They are also characterised by highly efficient performance and very low noise emissions. With chillers and heat pumps with reversible cycles, you can provide energy not only for cooling, but also for heating. With all these options available, we can provide you with the ultimate choice for your chiller needs. 10 PR-2014-0005-GB Subject to modification R4-05/2016

Type code Indoor and Outdoor Units Indoor Unit Type code D R C 3 036 A 5 D R C X DENCO Products Row-DENCO Chilled water Split system 3 300mm Wide unit DRX DRC 020 025 035 036 Unit size 051 071 121 A Series 5 230 V / 1Ph / 50Hz Outdoor Unit Type code D R O U D 051 A 5.N D R O U D DENCO Products Row-DENCO Outdoor units Condensing unit R410A 051 071 Unit size 121 A Series design 5 230V / 1Ph / 50 Hz (Size 051 Only) 1 400V / 3Ph / 50Hz / +N (Size 071 & 121 Only) N W Standard configuration Winter start kit configuration PR-2014-0005-GB Subject to modification R4-05/2016 11

DencoHappel is a globally operating company with great expertise in air treatment, air conditioning and filtration technology. Our nearest consulting and service teams will be glad to discuss ideas and develop creative and effective solutions with you. www.dencohappel.com