GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic locker locks from GANTNER. The control units operate in online mode and communicate with a host PC/server. The master controller serves as the communication bridge between the host PC/server and the GAT NET. Controller S 7000 slave controllers. For system flexibility, different slave controllers are available to suit the leading RFID technologies (see order information). Functional description The correct type of slave controller must be used to suit the RFID technology in operation. The slave controllers are connected to the master controllers via a serial interface. Each master controller can control up to 8 slave controllers and 192 locks over a maximum cable length of 200 m. For smaller MIFARE /ISO systems, a light version of the slave and master controllers is available (see functionality table). In online operation, the slave controllers receive data carrier information via the connected locks. This information is sent via the master controller to the PC/server for authorization. The current status of the locker system is also forwarded to the PC/server, thereby allowing the status of each locker to be visualized using, for example, GANTNER PC software. An emergency mode function for online mode ensures operation continues if communication to the PC/server is temporarily interrupted. Highlights Connection of locks via industry-standard MOLEX plugs LED status display Simple configuration with GANTNER software tools Firmware update via host interface possible Diagnostic system for detecting lock problems Integration into alarm system (locker break-in alarm) Order information Description Master controller for max. 8 slave controllers Light Master controller for max. slave controllers, no relays and no optocouplers Light ext. Light extension license for max. 8 slave controllers F/ISO MIFARE /ISO 1569 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks Part No. 25224 978541 978440 25426 Accessories Description Part No. F/ISO Light MIFARE /ISO 1569 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks 42970 GAT NET.Lock 7000 Electronic locker lock 6854 B LEGIC slave controller for max. 24 GAT NET.Lock 7000 2525 GAT NET.Lock Cable 5m 5 m connection cable for the GAT NET.Lock 7000, 4-pin MOLEX plug on both ends 7440 ICLS iclass slave control unit for max. 24 GAT NET.Lock 7000 76858 GAT NET.Lock Cable Extension m m extension cable for the GAT NET.Lock 7000 GAT NET. 20V supply unit GAT NET. Cord xxx cord for power supply unit. 494181 (EU), 494282 (UK), 511474 (AUS), 6685 (US), 6674 (D) GAT NET. Plug Plug to forward the power supply GAT Patch Kabel 5805 5 m, shielded Ethernet patch cable with 8-pin RJ45 plugs 810021 6944 See description 70426 90921 Controller functionality table (F/ISO) Number of relays Number of optocouplers Max. no. of slave units Max. no. of NET.Locks Master Standard Master Light Slave Standard Slave Light 4 0 - - 4 0 - - 8 * - - 192 (via slaves) 6 (via slaves) *expandable to 8 with additional license (Part No. 978440) 24 12 1
Technical data Nominal voltage UDC: supply unit: Reader types of slave control lers - F/ISO: - B: - ICLS: Maximum locks per slave controller: Maximum slave controllers per master controller: Memory (Master): 24 V External power supply units available (see order information) MIFARE + ISO 1569 LEGIC (Advant) HID iclass - Slave standard: 24 - Slave light: 12 - Master standard: 8 - Master light: * Internal memory for 10,000 bookings SD card slot for memory expansion, log files, firmware update or user lists Digital inputs (master controller): - Master standard: 4 - Master light: 0 Digital outputs (master contr.): - Master standard: 4 - Master light: 0 *expandable to 8 with additional license (Part No. 978440) Interface to the locks: Interface betw. slave and master: Master and server: 1 Wire (special cable for supply and data signal) Ethernet Connectors: - Master to server (Ethernet): RJ 45 - Slave to master (): RJ 45 - Locks: MOLEX, type Micro-Fit.0 TM - : MOLEX Housing material: Plastic (ABS - V0) Dimensions: 10 mm x 1 mm x 42 mm (12.2 x 5.24 x 1.65 ) Permitted ambient temperature: 0 C to +60 C Protection type: IP 40 Protection class: Weight: Environment class based on VdS 2110: I Approx. 600 g II (conditions in indoor areas) Dimensions Light 1 1.0 mm (5.24 ) 8 7 9 Light 10 2 10.0 mm (12.2 ) 6 5 4 10 Typical application 2 1. GAT NET.Controller M/S 7000 (same housing for master and slave) 2. SD card slot. Ethernet interface for PC/server connection 4. Relay outputs 5. DC 24 V output 6. Digital optocoupler inputs 7. supply input (DC 24 V) 8. in-/output (for master / slave controller connection) 9. and buttons and status LEDs 10. GAT NET.Lock 7000 connection sockets to the server/host Ethernet Master Controller Master Controller + power + power Plug GAT NET.Lock 7000 Identification with RFID data carrier Lockers 2
Installation The GAT NET.Controller 7000 master and slave controllers must be installed in the vicinity of the connected GAT NET.Lock 7000 locks to keep cable lengths to a minimum. Usually the controllers are stored on top of the lockers. Although the permanent fixing of the controllers is not required, when a controller is to be permanently mounted, e.g., on a wall, use the screw holes provided in the base of the controller. The housing does not have to be opened for this process. Measurements for installation 270.5 mm (10.65 ) 4.8 mm (0.19 ) 4.8 mm (0.19 ) 5.5 mm (0,22 ) Ø 4.8 mm (0.19 ) 0.5 mm (0.02 ) 1 mm (5.24 ) 154.8 mm (6.09 ) 154.8 mm (6.09 ) 09.6 mm (12.19 ) Installation process 1. Drill three mounting holes based on the measurements in the diagram above. Depending on the supporting surface, use the appropriate drill diameter for the screws and/or wall plugs (screws to max. M4). 2. Screw in the top two screws approximately half way.. Mount the controller housing on the top screws and push down until the housing stops against the screws. Tighten screws if necessary. 1. 2.. 4. Screw the third screw into the bottom mounting hole and tighten firmly. 1. 2. 5. Ensure the controller is secured firmly and cannot be removed.
Electrical connections - GAT NET.Lock 7000 connections 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 Note: The F/ISO Light has 12 lock connection ports and network connections to the GAT NET.Lock 7000 locks supply GAT NET. (or power plug - see description below) From master controller or from previous To the next GAT NET.Lock 7000 connections The locks are connected using a GAT NET.Lock Cable 5m (Part No. 7440). The 5 m cable can be extended using the GAT NET.Lock Cable Extension m (Part No. 810021) or to max. 10 m using the GAT NET. Lock Connector (Part No. 44212) and another GAT NET.Lock Cable 5m. The numbers on the determine the channel assignment for the locks. The GAT NET.Lock 7000 locks must not be connected to the GAT SMART.Controller S 7000! Network connections - bus connection to slave controllers via RJ 45 jacks. On the, connect the incoming line (server/master side) to the socket and the outgoing line (to next slave controller) to the socket. Recommended cabling : min. CAT 5 (STP), 200 m maximum cable length per line. LED signaling supply There are two possibilities for power supply: is connected to the MOLEX socket labeled. Use the supplied power supply unit (see technical data). 1. A power supply is connected to every in a line. 2. A power supply is connected to a few controllers that forward power on to the remaining controllers in the line. For the controllers that are not directly supplied, a power plug (see order information) must be plugged into the socket. Note: A power supply must always be connected to the first slave controller. If five or more slave controllers are used, the fifth controller must also be supplied in addition to the first controller. From master controller Plug yellow green - (yellow): Connection to the master controller - (green): communication active - (blue): Lock action - (green/red): Status information (see manual) for the line must be forwarded in the correct direction. Use the socket to continue supply to the next controller as shown above. Reset and mode buttons - : 1. Reset of controller (see manual) 2. Delete configuration = reset to default (see manual) - : Perform automatic antenna adjustment (see manual) 4
Electrical connections - Ethernet connection (to host) Note: The GAT.NET Controller M 7000 F/ISO Light does not have any relays or optocouplers and slave controller connections SLAVES ADD-ON Ethernet to host supply GAT NET. (or power plug - see description below) To the first Network connections - Ethernet to host via RJ 45 jacks. - bus connection to slave controllers via RJ 45 jacks. - 200 m max. cable length per line. The must be connected to the SLAVES socket! Recommended cabling Ethernet: min. CAT 5 (STP) : min. CAT 5 (STP), 200 m max. cable length per line. LED signaling yellow SLAVES green ADD-ON supply is connected to the MOLEX socket labeled. Use the supplied power supply unit (see technical data). Note: For a tidy installation, the power supply can be stored in the designated slot in the bottom of the controller housing. The WEEE symbol on GANTNER products and their packaging indicates that the corresponding material must not be disposed of with normal household waste. Instead such marked waste equipment must be disposed of by handing it over to a designated electronic waste recycling facility. Separating and recycling this waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. Please contact your local authority for further details of your nearest electronic waste recycling facility. - (yellow): Connection to the slave controller - (green): communication active - (blue): For future use - (green/red): Status information (see manual) Reset and mode buttons - : 1. Reset of controller (see manual) 2. Delete configuration = reset to default (see manual) - : Reserved for future use Safety instructions - This device must be installed by qualified personnel only. - The applicable safety and accident prevention regulations must be observed. - Safety devices must not be removed. - Please observe the technical data of the device specified on the data sheet. - The device must be disconnected from the power supply prior to installation, assembly or dismantling. 5