crio PN Installation Instructions V0.2/ COMSOFT

Similar documents
DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DF PROFINET IO CPCI. Installation Instructions V1.3/ KUNBUS

DF PROFI II PC/104-Plus

CPCI-PS24 24V-Power Supply

PHOENIX CONTACT - 10/2009

MINI MCR-SL-UI-2I(-SP)(-NC)

Serial PROFIBUS Interface

Type ME43. Quickstart

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL MC 2000E (SM40) LC

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Multiturn absolute encoder

MINI MCR-SL-UI-REL(-SP)

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

MINI MCR-SL-PT100-UI(-SP)(-NC)

BNI PNT Z015. IP67 Modules 16 Input User s Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

AXL E PN DI8 DO8 M12 6P

Veritas Appliance Hardware Service Procedure

GS Dupline Profinet Gateway. Benefits. Description

u::lux NetCon & u::lux NetCon Power

User Manual Gateway component for EtherNet/IP

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

AXL F BK PN. Axioline F bus coupler for PROFINET. Data sheet. 1 Description

Agilent OBSAI Protocol Tester

CP ADVANCED. Function

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

AS-i Safety Relay Output Module with Diagnostic Slave

Operating Manual FPGA-based High-Speed Micro-PLC

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Manual Industry Interfaces

Instruction Manual Power Distribution System SVS16-PN-XX

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

PHOENIX CONTACT - 05/2007

Fieldbus slave modules w/o I/Os

ICF-1150 Series Quick Installation Guide

SFP 10/100/1000Mbit Copper RJ45 Transceiver

PHOENIX CONTACT - 06/2006

PHOENIX CONTACT - 02/2007

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

IE/PB LINK PN IO. PROFINET applications

PLC PFC200 Controller PFC200 CS 2ETH RS

HEC. General Operating, Maintenance and Installation Manual

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

VME64x System Subrack 8 U

onlinecomponents.com

MGate 5111 Quick Installation Guide

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Valve island VM10 with PROFINET Interface 8, 10, 12 or 16 stations. Operation & Service Manual

CPCI System Subrack 1 U

PHOENIX CONTACT - 07/2005

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Operating Instructions VEGAMET 381

ICF-1150 Series Quick Installation Guide

P3-SCM. General Specifications

MGate 5102-PBM-PN Series

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

User Manual Digital Input Module

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

Installation Instructions

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

Encoder WDGA 58A PROFINET-IO (cov)

Installation Instructions

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TRC-190 User s Manual

LVX Control Unit. Features:

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

General Specifications. P2-SCM Serial Communications

Extension module for BACnet over Ethernet / IP and graphic Web functions

Instruction Manual Power Distribution System SVS16-EN-XX

PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04

AnyBus-PCI Profibus DPV1 Master

Digital ac/dc (24V) Input Module

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH

Transcription:

crio PN Installation Instructions V0.2/10.06.2015 COMSOFT crio PN-Installation- V0.2/10.06.2015

i:\icp\project\700391_crio_pn\anwenderdoku\installation\version_0.2\crio_pn_e.doc Revision History Version Date Description Resp. V0.2 10.06.2015 Ambient temperature changed to 0 - +50 C JK V0.1 03.02.2011 Initial Version JK COMSOFT GmbH Wachhausstrasse 5a 76227 Karlsruhe Phone +49 721 9497-0 Fax +49 721 9497-129 Copyright 2015 by COMSOFT GmbH This document includes data that shall not be duplicated, used, or disclosed - in whole or in part - for any purpose other than to evaluate this document. If, however, a contract with a customer is in force, the customer shall have the right to duplicate, use, or disclose the data to the extent provided in this contract. This restriction does not limit the customer s right to use the data in this document if it can also be obtained from another source without restriction. The data subject to this restriction are confidential in all pages of this document.

Installation Instructions Contents Contents 1 Installation of the Module... 1 2 LEDs and Connectors... 3 2.1 Position of LEDs and Connectors... 3 2.2 LED's... 4 2.3 Power connector... 4 3 Technical Data... 5 3.1 Use in hazardous locations... 5 4 CE- Conformity Declaration... 6 COMSOFT crio PN-Installation-V0.2/10.06.2015 i

Contents Installation Instructions List of Figures Figure 1: crio PN module... 2 Figure 2: LEDs and connectors... 3 ii crio PN-Installation-V0.2/10.06.2015 COMSOFT

Installation Instructions Contents List of Tables Table 1: Meaning of the LEDs... 4 Table 2: Power requirements... 4 Table 3: Technical Data... 5 COMSOFT crio PN-Installation-V0.2/10.06.2015 iii

Contents Installation Instructions Blank page iv crio PN-Installation-V0.2/10.06.2015 COMSOFT

Installation Instructions Safety information 1 Safety information WARNING: Disregarding this warning may result in damage to equipment and/or serious personal injury. Only qualified personnel may start up and operate this device. According to the safety instructions in this text, qualified personnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment according to the standards of safety technology. In addition, these persons must be familiar with all warning instructions and maintenance measures in this text. WARNING: The crio PN is designed exclusively for PELV operation according to EN 60950/EN 60204/VDE 0805-1. Only protective extra-low voltages according to the defined standards may be used to supply. i i Shielding The shielding ground of the connected twisted pair cables is electrically connected to the female connector. When connecting network segments, avoid ground loops, potential transfers, and voltage equalization currents via the braided shield. NOTE: Electrostatic discharge! The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD), in accordance with EN 61340-5-1 and EN 61340-5-2, as well as IEC 61340-5-1 and IEC 61340-5-2. Housing Only staff authorized by COMSOFT is permitted to open the housing. COMSOFT crio PN-Installation-V0.2/10.06.2015 1

Installation of the Module Installation Instructions 2 Installation of the Module The crio PN module is a PROFINET IO Device module for National Instruments CompactRIO system. The configuration entirely takes place by means of the delivered software. Thus, no jumpers or DIP-switch adjustments are necessary. To mount the module in the CompactRIO system, please proceed as follows: Switch off the CompactRIO system Plug the crio PN module into slot 1 until it snaps in Pay attention to a proper adjustment of the board in the guidance (avoid canting!). Important note: The crio PN module requires 1.7 W of power, so you must use it in Slot 1 while leaving Slot 2 empty. Important note: The crio PN module is supported only in CompactRIO reconfigurable chassis, such as an NI crio-911x, and NI Single-Board RIO devices. Figure 1: crio PN module 2 crio PN-Installation-V0.2/10.06.2015 COMSOFT

Installation Instructions LEDs and Connectors 3 LEDs and Connectors 3.1 Position of LEDs and Connectors PWR - Power indication LED SF System Fault LED SPI - Activity LED BF - PROFINET Fail LED Power Power supply connector (plug within scope of delivery) Port 2 RJ 45 Profinet IO Realtime switch Ethernet port 2 Port 1 RJ 45 Profinet IO Realtime switch Ethernet port 1 Figure 2: LEDs and connectors COMSOFT crio PN-Installation-V0.2/10.06.2015 3

LEDs and Connectors Installation Instructions 3.2 LED's LED Colour State Function PWR Green OFF No power supply connected ON Power supply connected SPI Green OFF SPI bus not active ON SPI bus active SF Red OFF No system fault active ON System fault active Possible reasons: SPI bus failure PROFINET Alarm active BF Red OFF PROFINET O.K ON PROFINET Bus fail Possible reasons: Configuration error PROFINET controller not active PROFINET controller gone PROFINET controller not connected Table 1: Meaning of the LEDs 3.3 Power connector Parameter Nominal value Input range Power consumption Table 2: Power requirements Value 24 Volts DC 12 36 Volts DC 1.7 W in Active mode (Receiving and Transmitting) 4 crio PN-Installation-V0.2/10.06.2015 COMSOFT

Installation Instructions Technical Data 4 Technical Data Parameter Functionality PN IO Conformance classes Processor Memory SPI Interface Ethernet interface Ethernet Connection Format Ethernet Connection medium Ethernet Cable impedance Ethernet Transmission speed Ethernet max. network segment expansion Ethernet Function Power Requirements Storage Temperature Range -40 C +85 C Ambient Temperature Range 0 C +50 C Table 3: Technical Data Value PROFINET IO Device LLDP supported SNMP MIB2 Physical Device Max. 254 bytes input and 254 bytes output data 16 PROFINET IO slots supported Min. 1 ms cycle time with RT Min. 250 us cycle time with IRT Acyclic communcation Read/Write Record with max. 256 Bytes Supported alarm types: Process Alarm, Diagnostic Alarm, Plug Alarm, Pull Alarm NRT, RT, IRT ARM 9 at 150 MHz 32 Mbyte SRAM 4 Mbyte Flash Type Memory SPI Slave up to 4 MBit/s 2 Port PROFINET IO Realtime switch 8-pin RJ45-female connector Twisted pair cable with a conductor cross-section of 0,14 mm²..0,22 mm² 100 Ω 100 MBit/s 100 m 100 Base-T(X) 1.7 W Active Mode (Transmitting and Receiving) 4.1 Use in hazardous locations The module is only suitable for use in nonhazardous locations. PROFINET IO with 100 MBit/s may not be used in hazardous locations. COMSOFT crio PN-Installation-V0.2/10.06.2015 5

CE- Conformity Declaration Installation Instructions 5 CE- Conformity Declaration We herewith declare that the CompactRIO Module crio PN corresponds to the requirements stated in the EU standards 89/336/EWG and 92/31/EWG. The interface corresponds to the following standards: EN 50082-1, EN 50082-2 and EN 50081-1 Manufacturer: COMSOFT GmbH Wachhausstr. 5a D-76227 Karlsruhe 6 crio PN-Installation-V0.2/10.06.2015 COMSOFT