User Guide - HyTronic Faucet S. Clearwater Dr. Schachenstrasee 77 (800) (0) Commander

Similar documents
Electronic Control Software User Instructions

For Palm TM Handhelds. Version 1.2. User s Guide

Cashbook. User Guide. User Guide

Roland CutChoice. Ver. 1 USER S MANUAL

Upgrading BMDM and BMRG Software and MPM, BDS and DCM Firmware

DME-N Network Driver Installation Guide for M7CL

MEEM Memory Ltd. User Guide ios

EAGLE-200. Intelligent Control Gateway. User Manual

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

Power. Document Part Number: This guide explains how the computer uses power. December 2005

GARNET. SEELEVEL II TM Tank Monitor INSTRUMENTS LTD. Model 709 Owner s Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: SERIAL NUMBER:

SP-400 Portable Water Analyzer Operation Manual. Rev. A Firmware version 1.02

PTDT V Quick Installation & Reference Guide. Ver Battery Management Solutions by. PowerDesigners

TotalShredder USB. User s Guide

Model 3000 Series Bluetooth User s Manual. May 2017 Revision 2

Ludlum Lumic Data Logger Software Manual Version 1.1.xx

Professional Edition (Release version 3.11x)

ProntoPro Intelligent Remote Control. User Guide

menu of icons which you can select which item you want to use to startup the computer.

INTELLEX SOFTWARE VERSION 3.1 UPGRADE

MODEL 3100 DISSOLVED OXYGEN ANALYZER MODEL 30 OPTICAL DISSOLVED OXYGEN SENSOR

UniLinc PC and PDA Application User Instructions

HP Video Over Ethernet. User Guide

XO SITE SECURITY SERVICES

FirePoint 8. Setup & Quick Tour

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

FarStone One. Users Guide

Streaming Smart Stick. Quick Start Guide

Power. Document Part Number: This guide explains how the computer uses power. March 2006

Dell EM+S Intune. Android Enrollment Guide. Version 1.5

Quick Setup & Getting Started

Getting Started (No installation necessary) Windows On Windows systems, simply double click the AntGram icon to launch the program.

Mobile Banking and Mobile Deposit Terms & Conditions

MegaStat Installation Instructions

Multipoint Temperature NET Data Logger

GX-2009 Data Logger Management Program Operator s Manual

Network-MIDI Driver Installation Guide

PRODUCT GUIDE. L e p i d e S o f t w a r e P r i v a t e L i m i t e d

TA Instruments New Features in TAM Air Assistant TM and TAM Assistant TM Software

R227. Terms Code Discount per Sales Code Qty Ordered AR-1227

TA Instruments New Features in DSCRun TM Software

Aimetis Thin Client 2.7. User Guide

End User License Agreement

Temperature & Humidity SMS Alert Controller

Beta Testing Licence Agreement

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009

TA Instruments New Features in TAM Air Assistant TM and TAM Assistant TM Software

Bluetooth Virtual Keyboard For Smartphone User Guide v1.7

Stellar Phoenix Windows Data Recovery - Pro

FlukeView Forms. Documenting Software. Getting Started

InfoRad SNPP-Connect. InfoRad, Inc.

Uploading Files Using File Drag and Drop

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d

EMU-2. Energy Monitoring Unit. User Manual

TOUPCAM QUICK GUIDE INSTALLATION MANUAL

Datalogging Conductivity/ TDS Meter. Instruction Manual

Oracle Enterprise Single Sign-on Kiosk Manager. User Guide Release E

GENERATOR BACKUP Web Server

SOFTRAID FOR THUNDERBAY. Quick Start Guide

Network tester for RFC-2544 LE-580FX-F2544. Users manual. The first edition

GX-2009 Data Logger Management Program Operator s Manual

Getting Started (No installation necessary)

INSTRUCTION MANUAL Data transfer software for VM-82A

OneControl PROGRAMMING MANUAL. Rev: Page 1 OneControl Programming Manual

User Manual Version 1.0

AhnLab Software License Agreement

MICROSOFT WINDOWS SERVER 2016 FOR EMBEDDED SYSTEMS STANDARD AND DATACENTER. the server manufacturer that distributes the software with the server; or

Bluetooth USB Adapter TALUS. User Guide

TA Instruments TA Update. Getting Started Guide

Eagle 2 Data Logger Management Program Operator s Manual

SOFTWARE GUIDE. ATP-based cleaning verification and tracking system for the health care industry

This guide describes features that are common to most models. Some features may not be available on your computer.

Quick Start Guide. Model 0260 Secondary Electronics

For ClassPad 300. ClassPad Manager. (ProgramLink) Limited Version. User s Guide. RJA

MANUAL. ENGLISH Odin Editor. Highlit e I nt ernat ional B.V. Vest ast raat EX K erkrade t he Net herlands

Daniel MeterLink Software v1.40

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

PM1703MO-1BT/PM1401GNB USER SOFTWARE GUIDE

BLUETOOTH SHUTTERBOSS. User Manual

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d

GX-6000 Data Logger Management Program Operator s Manual

Version /13/2014. User Manual. mydlink Home Smart Plug DSP-W215

PRODUCT GUIDE. L e p i d e S o f t w a r e P r i v a t e L i m i t e d

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

Users Manual OPN Pocket Memory Scanner

SysInfoTools NSF Duplicate Remover

ABB Network Partner. User s Manual CAP/REx 500*2.0

This guide describes features that are common to most models. Some features may not be available on your tablet.

TOOLS for n Version2 Update Guide

CX Recorder. User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

Statement of Volatility Wide Format 6604/6605 Solution

ios App User Manual Fill in the serial number (case insensitive), login (used to recover password), and choose a password.

03 Series Data Logger Management Program Operator s Manual

Computer Paging Software

Veeam Universal Application Item Recovery

HP ipaq rz1700 series. How Do I...? Look inside to find answers to frequently asked questions about product setup, features, and more.

Mind-Sight Lab-Volt Multimedia etraining System

USB-FC-110 LYNX USB FOCUS CONTROLLER USER MANUAL

Professional Benchtop Conductivity meter BC3020

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

Transcription:

Chicago Faucets Geberit International AG User Guide - HyTronic Faucet 2100 S. Clearwater Dr. Schachenstrasee 77 Des Plaines, IL 60018 CH-8645 Jona (800) 323-5060 +41 (0) 55 221 63 00 Commander

1.0 Overview Geberit Commander software allows tool-free faucet control for the Hytronic Series Electronic Faucets. Geberit Commander s quick and easy infrared control makes troubleshooting, maintenance and operational changes easy. The patented Geberit Commander system uses wireless technology to communicate with the faucet to provide: Error diagnosis Maintenance scheduling Faucet history Current faucet status Battery information Ability to change faucet operating modes and ranges Activation of Clean, Hygiene and Smart Power Modes Ability to increase or decrease delay times Troubleshooting help On hand Parts List and Contact Information 1.1 Geberit Infrared Embedded Intelligence The Geberit Infrared embedded intelligence in the faucet controls the faucet and makes it works. Geberit Infrared delivers advanced I.R. features and trouble-free electronic water control of all types, shapes and sizes in almost any environment. This new cutting-edge technology not only delivers advanced features such as digital reflection filtering and adjustable power output range, but also provides two-way interaction between Chicago Faucets Infrared-enabled appliances and the Palm-based hand-held Geberit Commander. 2.0 Getting Started NOTE: Do not attempt to use Geberit Commander on the Palm computer under the faucet. The water will activate if you are too close to the faucet. This will damage the Palm and void your Palm warranties. Turn the Palm on to access the Geberit Commander icon. If you do not see the icon, tap the Applications icon until you see the Geberit Commander icon or tap the triangle in the top right corner of the screen to display the pick list. Select ALL from the pick list at top right. Tap the Geberit Commander icon shown in Figure 1. Figure 1 Geberit Commander Icon Revision 1.0 Page 1 10/29/2006 JB

2.1 Communication Distance Requirements In order to start using the Geberit Commander software you must first tap the Accept button, shown in Figure 2, indicating that you have read and agree to the license agreement published on the Chicago Faucets web page as well as on the back of this user manual. Figure 2 License Agreement Notice 2.2 Communication Distance Requirements The Get Faucet Data or Adjust Faucet functions work from 9-24 inches away from the faucet sensor. Fresh or charged batteries in the Palm computer optimize the communication distance. 3.0 Geberit Commander Main Menu Scan Geberit Fitting retrieves and stores faucet and/or flush valve data. View Your Palm Scans provides all previously scanned faucet and/or flush valve data without having to scan the fitting. View General Information allows access to five different information areas for a desired product without having to scan the fitting. These areas include: 1) Review Palm Scans, 2) Contact Geberit, 3) Accessories, 4) Replacement Parts and 5) Troubleshooting Quit allows the user to exit Geberit Commander Application. Figure 3 Geberit Commander Main Menu Revision 1.0 Page 2 10/29/2006 JB

4.0 Scan Geberit Fitting Tapping the Scan Geberit Fitting button on the main menu initiates the data retrieval process from the faucet. The user is being notified that the scanning is in process by displaying the following scanning message (figure 4a). Figure 4a. Scanning in Process If no fitting is seen in 10 sec, the Commander software will time out, prompting the user to try again (figure 4b). Adjusting the distance and angle to the faucet can provide a better chance of a complete successful scan. 4.1 Get Faucet Data Figure 4b. Scan Time Out Tapping the Scan Geberit Fitting button on the main menu retrieves all the information about the faucet you select and saves all that information to the Palm automatically. The faucet data can also be reviewed and edited. The Get Data Menu displays the faucet data as shown in Figure 4c. It displays battery status, unique faucets serial number as well as the model number. After retrieving faucet information, the user is able to adjust faucets settings and parameters. Tapping on the Scan Next will allow the user to continue scanning other fittings and exit button will allow him to return to Geberit Main Menu. Revision 1.0 Page 3 10/29/2006 JB

Figure 4c Get Data Menu 4.2 Current Settings Menu Tapping on Current Settings button from Get Data Menu the user be able to determine how the current faucet settings compare to original factory settings (Figure 4d). In addition, the user would be able to reset the unit to original factory settings or just reset the unit without affecting any of the faucet settings. 4.2a Reset to Factory Settings Figure 4d Current and Factory Settings Tapping on the Reset to Factory Settings button will result in resetting all the faucet parameters back to original values. The Reset Caution screen will appear (Figure 4e) that will ask for the conformation that this is a desired operation. After the unit has been reset it will go in a calibration sequence. Revision 1.0 Page 4 10/29/2006 JB

Press Reset to continue with Resetting the faucet to Factory Settings and Cancel to return back. NOTE: The faucet will activate while in recalibration sequence! 4.2b Reset Unit Figure 4e Reset to Factory Caution Screen From Current Settings Screen if this button is activated it is for the reasons of resetting the unit and recalibrating the faucet without changing any of the settings on the unit. The Reset Caution screen will appear (Figure 4f) to insure that this is a desired operation. Press Reset to continue with Resetting the faucet to Factory Settings and Cancel to return back. NOTE: The faucet will activate while in recalibration sequence! Figure 4f Reset Unit Screen Revision 1.0 Page 5 10/29/2006 JB

4.2c Clean Mode From Get Data Menu tapping on the Clean Mode button will allow the user to activate this mode and disable the faucet for pre-determined amount of time. During the Clean Mode the water will not flow and the unit will indicate the Cleaning Mode by flashing the LED. Factory setting is set to 2 minutes, but the custom setting allow user to specify this time anywhere from 1 to 10 minutes. Tapping on the Set button will initiate communication with a faucet. 4.2d Note Screen Figure 4g Clean Mode Screen If from Get Data Menu, the Note button is tapped, the user will be able to add comments regarding this particular faucet as well as the location of the installed faucet. Added comments must be followed with tapping the Save button in order for the information to remain in the Commander software. Cancel button will take the user back to Get Data Menu. Clear button will erase any existing comments, while Restore button will place the comments back. Figure 4h Clean Mode Screen Revision 1.0 Page 6 10/29/2006 JB

4.2e Fitting History Menu Tapping Faucet History button from Get Data Menu will allow user to take a look at the detailed information regarding the faucet that was scanned (entering Review Data section). By tapping on left and right arrows ( < > ) the user can scroll to all the previously scanned faucets. Note button will allow user to add location and comments information. Search button will allow user to search for a particular faucet scan by either serial number or location. If serial number search is used and the exact serial number is not found the software will display the closest number available in Commander data base. User can review faucet data that were grouped under 4 different tabs (Power, Settings, Time and Uses) shown in Figures 4i 4l. Note: The Date Scanned is taken from Palm clock. Please make sure that Palm s time is set correctly. Figure 4i Power Tab Figure 4j Setting Tab Figure 4k Time Tab Figure 4l Uses Tab Revision 1.0 Page 7 10/29/2006 JB

5.0 Adjust Fitting Adjusting Faucet is easily done from the Get Faucet Data Menu. Tap the Adjust Fitting button and drop down menu will appear as shown in Figure 5a. There are 3 possible options that the user can pick. Factory Settings, Adjust Mode Settings and Adjust Sensor Settings. 5.1 Factory Settings Figure 5a Adjust Fitting Drop Down Menu Choosing this option the user will be able to evaluate and /or quickly remove any changes that were made to the faucet mode or ranges and set the unit back to factory settings. The screen is shown in Figure 5b. Figure 5b Factory Settings If any of the Reset options is chosen the unit will recalibrate. NOTE: The faucet will activate while in recalibration sequence! Revision 1.0 Page 8 10/29/2006 JB

5.2 Adjust Mode Settings If from Adjust Fitting Drop Down Menu user chooses Adjust Mode Settings, the Adjust HyTronic Modes Menu will appear (Figure 5c). This Menu allows user to activate and / or change any mode setting. 5.2a Adjust Normal Mode Figure 5c Adjust HyTronic Modes Menu Normal mode water flows within 1/4 second after activating sensor (i.e., putting hands in front of window) and continues to stay on as long as hand presence is detected. Maximum factory ON time is 40 seconds. This is the factory default setting. The user can adjust Maximum Run Time by choosing the Custom Setting option and selecting the time ON in the range from 30 180 seconds. The time can be selected by either using the scroll bar or + / - buttons. By tapping the set button the specified value is sent to the faucet. (Figure 5d). Figure 5d Adjust Normal Mode Revision 1.0 Page 9 10/29/2006 JB

5.2b Adjust Scrub Mode Scrub mode water continues to flow for 60 seconds (default) after deactivating the sensor (i.e., removing hands). Other factory-preset times are 120 and 180 seconds. Custom setting can be set to any second value between 1-180 sec. The time can be selected by either using the scroll bar or + / - buttons. By tapping the set button the specified value is sent to the faucet. (Figure 5e). Figure 5e Adjust Scrub Mode 5.2c Adjust Metered Mode Metered mode the 10-second on time (default) starting from first hand detection. Custom setting can be set to any second value between 3-180 sec. Delay time 0-5 sec is the time range that the faucet user must leave detection area before another metered water flow is initiated. The time can be selected by either using the scroll bar or + / - buttons. By tapping the set button the specified value is sent to the faucet. (Figure 5f). Figure 5f Adjust Metering Mode Revision 1.0 Page 10 10/29/2006 JB

5.2d Adjust Water Saver Mode Water Saver mode 10-second maximum on time starting from first hand detection and fast turnoff when hands are removed. Custom setting can be set to any second value between 3-180 sec. Delay time 0-5 sec is the time range that the faucet user must leave detection area before another metered water flow is initiated. The time can be selected by either using the scroll bar or + / - buttons. By tapping the set button the specified value is sent to the faucet. (Figure 5g). 5.2e Adjust Hygiene Flushing Mode Figure 5g Adjust Water Saver Mode Hygiene mode if activated this mode turns on the faucet automatically after predetermined time set by the user after the last time the faucet was used. This time is determined with Interval between Activations and it ranges between 1 and 168 hours. The duration of the activation is predetermined by the user with Duration of Activation ranging anywhere 3-180 seconds. By tapping the set button the specified value is sent to the faucet. (Figure 5i). Figure 5i Adjust Hygiene Mode Revision 1.0 Page 11 10/29/2006 JB

5.2f Adjust Manual Teach In Mode Manual Teach In mode this function is factory disabled and by enabling it the user would be able to activate Clean Mode. 5.2g Adjust Smart Power Mode Figure 5j Manual Teach In Mode Smart Power mode if activated for any user predetermined time if the faucet is not activated for that time the unit will reduce the frequency of scans from 4 times per second to 1 time per second. The unit returns back to normal operations once activated again. This conserves on battery consumption. The time can be selected by either using the scroll bar or + / - buttons. By tapping the set button the specified value is sent to the faucet. (Figure 5k). Figure 5k Smart Power Mode Revision 1.0 Page 12 10/29/2006 JB

5.3 Adjust Sensor If from Adjust Fitting Drop Down Menu user chooses Adjust Sensor Settings Screen (Figure 5l) will appear. This menu allows user to change detection sensor range between Short, Normal, Far and Maximum together in combination with offset bar (+2 to -2 inches) providing a great number of possibilities. In addition if there are any interferences from either sink or lights, mirrors the upper or the lower beam can be turned off in order to compensate. By tapping the set button the specified value is sent to the faucet. 6.0 Review Date Figure 5l Adjust Range Settings From Get Data Screen, the user can chose the option to review all previous scans that are stored in Commander Software. Tapping onto Review Data pull down menu, the user will have 3 options to review data. Sort by Scan Data sorts all the scans in Commander library of scans by the dates when the units were scanned. Sort by Serial # will sort all the previous by serial number order (low to high). Sort by location option will sort the previous scan by alphabetical order. Figure 6 Get Data Screen w/review Data Menu Revision 1.0 Page 13 10/29/2006 JB

7.0 Troubleshooting From Get Data Screen (Figure 7a) tap on Troubleshooting line and Troubleshooting Flowchart Screen will appear. Answer the question and tap on solve to get a faucet diagnostic. 8.0 Information Figure 7a Get Data Screen Figure 7b Troubleshooting Screen From Get Data Screen tap on the Information drop down menu (Figure 8a). Contact Geberit (Figure 8b), HyTronic Parts List (Figure 8c) and HyTronic Accessories List screens are options that user can select. Figure 8a Clean Mode Screen Figure 8b Clean Mode Screen Figure 8c Clean Mode Screen Figure 8d Clean Mode Screen Revision 1.0 Page 14 10/29/2006 JB

9.0 Bypass Menu View Palm Scans and General Information From Main Menu (Figure 9a) the user is able to Review Previously Scanned fittings (Figure 9b), as well as access General Information for each product (Figure 9c) that includes Contact Geberit Information, Product Accessories and Replacement Parts Lists as well as Troubleshooting Information (Figure 9d). Figure 9a Main Menu Figure 9b View Palm Scans Figure 9c View General Information Figure 9b Product Information 10.0 Back Up Data It is extremely important that you follow a strict backup routine to avoid the loss of any scanned data. Your scanned faucet data is automatically backed up to your desktop computer when you HotSync. For more information on the HotSync operation, refer to the Palm User Guide you received with your Palm. 11.0 License Agreement END-USER LICENSE AGREEMENT The GEBERIT COMMANDER software (the "Software") is owned exclusively by The Chicago Faucet Company ( CFC ). You may obtain a copy of the Software by downloading the Software via the Internet from designated Revision 1.0 Page 15 10/29/2006 JB

download locations. THIS END USER LICENSE AGREEMENT ( AGREEMENT ) GOVERNS YOUR INSTALLATION AND USE OF THE SOFTWARE FOR FREE ON A NON-EXCLUSIVE BASIS. ACCEPTANCE OF THE TERMS OF THIS AGREEMENT DOES NOT GRANT TO YOU ANY OTHER RIGHTS NOT EXPRESSLY GRANTED IN THIS AGREEMENT AND DOES NOT CONSTITUTE A TRANSFER OF TITLE TO THE SOFTWARE TO YOU. THE SOFTWARE IS LICENSED TO YOU FOR USE UNDER THE TERMS AND CONDITIONS CONTAINED HEREIN. YOU MUST CONSENT AND AGREE TO ALL OF THE TERMS AND CONDITIONS OF THIS AGREEMENT PRIOR TO USE OF THE SOFTWARE. PLEASE READ THIS ENTIRE AGREEMENT CAREFULLY BEFORE YOU ACCEPT THIS AGREEMENT. YOU WILL BE DEEMED TO HAVE ACCEPTED ALL OF THE TERMS AND CONDITIONS OF THIS AGREEMENT AS FOLLOWS: By clicking on the ACCEPT button; or By downloading, installing and/or using the Software. If you do not agree to all of the terms and conditions of this Agreement you should proceed as follows: Click the DO NOT ACCEPT button; and Uninstall the Software from your computer hard drive and do not use the Software. 1. LICENSE GRANT (a) License. Upon acceptance of this Agreement, and subject to your continued compliance with the terms and conditions of this Agreement, CFC grants you a limited, non-exclusive, nontransferable, terminable license to use the Software solely for internal business purposes and solely on one Designated Terminal (the "Standard License"). (b) Registration of Software. Once you have downloaded and installed the Software, you are required to register your contact information with CFC. (c) Scope of Use. Upon registration of the Software, you may operate and store the Software in machine readable form on one CPU solely for the purposes of using the Software in accordance with this Agreement. You may also make one copy of the Software in machine-readable form solely for backup purposes provided that you reproduce all copyright and proprietary notices that are on the original copy of Software. You may also use any documentation which accompanies the Software. You agree not to modify, translate, adapt, enhance, create derivative works, reverse engineer, decompile, disassemble, network, rent, lease, or otherwise distribute or transfer, or request or assist others to modify, translate, adapt, enhance, create derivative works, reverse engineer, decompile, disassemble, network, rent, lease or otherwise distribute or transfer the Software except as expressly set forth in this Agreement. (d) Support. CFC may provide limited customer and technical support to registered users for the then current version of the Software in its sole discretion. CFC shall have the right to reduce or modify the level of support, or discontinue support at any time without notice. CFC will have no obligation to provide support for any previous version of the Software. Nothing contained in this Agreement shall obligate or require CFC to furnish or license to you any updates, modifications, enhancements, bug fixes or derivative works of the Software. Revision 1.0 Page 16 10/29/2006 JB