O UT IN O UT IN O UT IN (-) NO C 12 (+) 12 NO C 1 2 3 4 5 GND IN A B A B A B T E RM I NAL I NT ERFACE O= Clear operations counter L xx=day(s) between battery load test C xx=day(s) between battery check test T=Battery load test CAUTIO N HOT RESISTOR!! S =Battery check test t akes 15 minutes?=d isply all values and selections E =exit terminal mode xx=value betw een 0 and 99 A l terminal inputs must be t erminated w ith the EN TER key S T AT US I ND I CA TOR S Bli n k in g Ch e c k Batter y LED, L oad or Check test in progress C ontinuosly iluminated Check Battery LE D, Battery Failure Bli n k in g L i ne A cti v e LE D, A C is present and unit functional C ontinuously of Line Active L ED, AC Line Failure K n if e S wit ch Cl o s e LE D, I luminated when sw itch closed T erminal S etting TTY 9600 8-N-1 F low C ontrol N one? E NTER, TO S TART C OM. OPTIONAL OPERATIONAL COUNTER LOCATION Document PC-006-3 Dimensional Data - Output Unit, Enclosure, and Cable Connector Ø 1 1/8 COMMUNICATION CABLE Ø 1/2 9 Ø 1 1/8 3 1/8 CABINET END 2 1/2 SENSOR END 11 3/4 OUTPUT UNIT 11 3/4 x 2 1/2 x 9 2 5/16 25 1/4 TYPICAL MOUNTING 23 7/8 Ø 5/8 (X5) 3 32 BATTERY TESTER 28 TYP MNTG HEATER & FAN ASSY OUTPUT UNIT 2 12V 33AH BATTERIES Ø13/16 (X3) Sample Catalog Numbers The following sample catalog numbers (with quantities) are representative of typical complete systems. A complete system includes a Sensor Unit(s), an Output Unit, an Enclosure and Power Source, and Cable(s) (01) CSVS-0550-1200, (01) CVO-001-115-01-00-00-01-00-00, 15-01-00-00-01-00-00, (01) E1-125-S, (01) CAB-0025 - One 550 BIL, 1200 amp combination current and voltage Sensor Unit, one Output Unit with 0-1A current output signal (O1 = 1A, O2 = null, O3 = null) and 0-115 VAC voltage output signal (O1 = 1.44 VA, O2 = null, O3 = null), one standard enclosure utilizing customer supplied 125 VAC, and one 25 ft cable (03) CSVS-0350-1200, (01) CVO-001-115-01-01-01-01-01-01, 15-01-01-01-01-01-01, (01) E2-024-L, (03) CAB-0045 - Three 350 BIL, 600 amp combination current and voltage Sensor Units, one Output Unit with 0-1A current output signals (O1 = 1A, O2 = 1A, O3 = 1A) and 0-115 VAC voltage output signals (O1 = 1.44 VA, O2 = 1.44 VA, O3 = 1.44 VA), one large enclosure with SEECO supplied 24 VDC power source, and three 45 ft cables 6
Document PC-006-3 Dimensional Data 115 15-500 kv,, Type CSVS Sensor units 230 kv and up are provided complete with corona suppression rings, which are not depicted here. For additional details consult the factory. Dimensions in Inches (Unless Otherwise Specified) kv 115 138 161 230 230 345 500 BIL 550 650 750 900 1050 1300 1470 A 54 1/2 63 1/2 71 1/2 89 1/2 101 1/2 115 1/2 131 1/2 B 45 54 62 80 92 106 122 5
Document PC-006-3 Dimensional Data 7.5-69 kv,, Type CSVS Dimensions in Inches (Unless Otherwise Specified) kv 7.5 15 25 34.5 46 69 BIL 95 110 150 200 250 350 A 16 18 1/2 22 1/2 26 1/2 30 1/2 38 1/2 B 7 1/2 10 14 18 22 30 4
Document PC-006-3 Catalog Numbers and Ratings To properly configure a complete sensor application, you must specify the catalog numbers for a sensor unit, an output unit, an enclosure and power source, and a communication cable. Consult the factory if assistance is needed to correctly specify the system components. Enclosure and Power Source Enclosure Size Std Large Power Source Catalog Value Supp. By Number 024 VDC Customer E1-024-S 048 VDC Customer E1-048-S 125 VDC Customer E1-125-S 120 VAC Customer E1-120-S 024 VDC Customer E1-024-L 024 VDC SEECO E2-024-L 048 VDC Customer E1-048-L 125 VDC Customer E1-125-L 120 VAC Customer E1-120-L Solar SEECO E4-024-L Enclosure catalog E1-125-S Power Source - The Output Unit will operate with customer supplied 24, 48, and 125 VDC or 120 VAC. An optional SEECO supplied 24 VDC power source complete with batteries, battery charger, and battery testing mechanism can be provided, which requires customer supplied 120 VAC. A solar power source can also be supplied for geographically remote applications. Enclosure - The Output Unit is provided complete with an enclosure. The standard enclosure is provided for most typical applications and is sized to accommodate the output device, terminal blocks for output signal wiring connections, up to three circular, MS connectors and power source inputs. A larger enclosure is available and is sized to accommodate the above material plus the optional SEECO supplied 24 VDC or solar power source, or other customer equipment. Communication Cable Catalog Number Base Length CAB -XXXX Note: To complete the Communication Cable catalog number, add the required cable length to the base catalog number. Add leading zeroes where necessary to create a four digit length value, i.e. a 175 foot linear length would be specified as CAB-0175. Communication from the Sensor Unit to the Output Unit is digital not analog, providing a maximum cable length of up to 4,000 feet. The cable length can be specified in 10 foot increments. One cable is required per Sensor Unit. The cable has a UV protected black PVC jacket, which is sunlight resistant, impervious to moisture and vapor penetration and is suitable for installation in both wet and dry locations. Each end of the cable is pre-terminated with a circular, MS connector for quick and easy connection to both the Sensor and Output Unit devices. Cable is suitable for direct burial. Cable catalog CAB-0045 3
Document PC-006-3 Catalog Numbers and Ratings To properly configure a complete sensor application, you must specify the catalog numbers for a sensor unit, an output unit, an enclosure and power source, and a communication cable. Consult the factory if assistance is needed to corrrectly specify the system components. Sensor Unit Voltage Catalog Number Nom BIL Wght, kv kv 600 Amp 1200 Amp 2000 Amp Lbs 7.5 95 CSVS-0095-0600 CSVS-0095-1200 CSVS-0095-2000 30 15 110 CSVS-0110-0600 CSVS-0110-1200 CSVS-0110-2000 32 23 150 CSVS-0150-0600 CSVS-0150-1200 CSVS-0150-2000 34 34.5 200 CSVS-0200-0600 CSVS-0200-1200 CSVS-0200-2000 37 46 250 CSVS-0250-0600 CSVS-0250-1200 CSVS-0250-2000 40 69 350 CSVS-0350-0600 CSVS-0350-1200 CSVS-0350-2000 44 115 550 CSVS-0550-0600 CSVS-0550-1200 CSVS-0550-2000 54 138 650 CSVS-0650-0600 CSVS-0650-1200 CSVS-0650-2000 59 161 750 CSVS-0750-0600 CSVS-0750-1200 CSVS-0750-2000 64 230 900 CSVS-0900-0600 CSVS-0900-1200 CSVS-0900-2000 75 230 1050 CSVS-1050-0600 CSVS-1050-1200 CSVS-1050-2000 80 345 1300 CSVS-1300-0600 CSVS-1300-1200 CSVS-1300-2000 139 500 1470 CSVS-1470-0600 CSVS-1470-1200 CSVS-1470-2000 156 Specify the catalog number that corresponds to your BIL and continuous current requirements. Output Unit Output Signal Format Catalog Number Current Outputs Voltage Outputs Current Voltage Base O1 O2 O3 O1 O2 O3 0-.5A/0-1A 0-67/0-115 CVO-001-115 -XX -XX -XX -ZZ -ZZ -ZZ 0-10 VAC CVO-001-010 -XX -XX -XX -WW -WW -WW 0-10 VAC 0-67/0-115 CVO-010-115 -YY -YY -YY -ZZ -ZZ -ZZ 0-10 VAC CVO-010-010 -YY -YY -YY -WW -WW -WW Note: To complete the Output Unit catalog number, add the required value to each of the six output signal fields of the base catalog number. If no output signal is required for the second or third current and voltage fields use 00 to represent null value. For current outputs XX use values.5 (0-.5A) or 01 (0-1A); for current outputs YY use 01 (1.44A). For voltage outputs WW use 01 (1.44 VA); for voltage outputs ZZ use 01 (1.44 VA), 15 (15 VA) or 25 (25 VA). Output Signal Formats - Current output signals are available with a standard format of 0-1 amp and optional formats of 0-.5 amp or 0-10 VAC (1.44 VA). Standard burden range is 0 to 2 ohms. Voltage output signals are available with standard formats of 0-115 or 0-67 and an optional 0-10 VAC. Standard VA is 1.44 but optional 15 and 25 VA are available for the 0-115 and 0-67 outputs. The 1.44 and 15 VA can be provided on all three outputs but the 25 VA can be provided for up to two outputs only. Other formats may be supported. Please contact the factory if your device requirements are other than the standard formats listed here. Inputs/Outputs - The Output Unit accepts up to three current inputs and three voltage inputs and provides up to six analog outputs. This allows a single Output Unit to support up to three Sensor Units of the same or different ratings. Alternately, the input signal from a single Sensor Unit can be used to provide up to three output signals for three separate load devices (meters, relays, rtu s, etc.). 2
Document PC-006-3 Combination Current and Voltage Sensor Type: CSVS (current and voltage) Mounting Orientation: Any direction Continuous Current: 600, 1200, 2000 Amp Voltage: 7.5-500 kv (line to line) BIL Rating: 95-1470 kv Accuracy: +/-.15% (current); +/- 5% (voltage) Description A light weight monitoring insulator (data collection device) capable of reproducing in phase proportional sinusoidal current and voltage waves for communication to customer devices (meters, relays, rtu s, etc.). Application Replaces conventional oil-filled CT/PT devices and optical sensors in applications such as voltage and current monitoring, relaying, fault detection (with direction), and autosectionalizing or SCADA operation of switches SEECO 69 kv 1200 amp current and voltage sensor, catalog CSVS-0350-1200 (wght 44 lbs) Ordering Information Standard Equipment Type CSVS current and voltage sensors consist of four major components; a Sensor Unit, Communication Cable, an Output Unit and an Enclosure. The Sensor Unit monitors both phase current and voltage and generates digital current and voltage output signals. The Sensor Unit consists of a silicon polymer insulator, current sensing coil, voltage sensing rod, line and base unit electronic cards and fiber optic cabling and potting. The Communication Cable transmits the Sensor Unit output signal to the Output Unit. The Communication Cable is provided in length as specified by the customer. Each end of the cable is terminated with a circular, MS connector. One cable is required per sensor unit. The Output Unit receives the digital current and voltage outputs from the Sensor Unit(s) and converts them to analog values for interface with the customer s devices. One Output Unit can support up to three different Sensor Units or provide up to three output signals for one sensor. Features & Benefits Small footprint, compact size Less than 10% of the weight of oil-filled devices Can be mounted in any orientation; provides flexibility in areas with limited clearances No CT saturation or PT Ferro Resonance No catastrophic failure; cannot overheat or explode Environmentally friendly, no oil or SF6 used as a dielectric; no special handling or disposal procedures No galvanic connection between potential and ground Generates safe, low voltage and low current outputs To Be Specified on Order A checklist is available to assist you in organizing and completing the information required; the following minimum information must be specified: Sensor Unit Catalog Number and quantity BIL Rating (kv) and Continuous Current Rating Mounting structure w/ details and dimensions Output Unit Catalog Number Required output (current): 0-.5A, 0-1A, or 0-10 VAC Required output (voltage): 0-67, 0-115 or 0-10 VAC Required VA of each signal output: 1.44, 15 or 25 Communication Cable Catalog Number and quantity Power source for Output Unit: 24, 48, 125, or 120 Enclosure Catalog Number Optional equipment or non-standard features An Enclosure is provided for each Output Unit and includes terminal blocks for digital and analog output signal wiring connections, power inputs and circular, MS connectors. 1