AMBUS IS M-Bus pulse collector

Similar documents
AMBUS ZS / Modem Signal-converter

0xc1 (Mass) 0xc2 (Flow) 0xc3 (Reserved) 0xc4 (BDE) 0xc5 (AMTRON X-50) 0xc6 (AMBILL) 0xc7 (TGR) 0xc8 (BDV) 0xc9 (DTF)

PADPULS2 M-BUS Pulse Input Modules

AB Axis Industries. Use

AMBUS Net, AMBUS ZS M-Bus remote meter reading system

Solenvis SL80 Pulse to M-Bus Converters

Temperature sensors and accessories for heat and cooling measurement points

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

CALEC energy master The benchmark in energy measurement

Technical Information VD E CALEC light. Heat calculator

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

M-Bus protocol CALEC energy master

TS2M-Bus Protocol Converter / User Manual

AEW Pulse Adapter. Building Technologies

CALEC ST Measuring of energy in heating and cooling installations

AEW36.2. Pulse Adapter. Siemeca AMR

GmbH, Stettiner Str. 38, D Paderborn

M-Bus Pulse Collector Twin-Pulse Instruction Manual

M-Bus Central Unit. Use

Communication description Page 2 29 CALEC ST II KNX TP1

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M2. Art.No.: IM003G + IM003GB. (Valid from M-Bus generation: $40)

MID approval no. DE-08-MI004-PTB004 Date of release

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

M-Bus-Logger Data Logger

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

CALEC energy master The benchmark for energy measurement technology

CALEC ST Multi-protocol heating and cooling energy calculator

M-Bus Central Unit OZW10

02/11/2015

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M4L. Art.-No. IM002G: (Valid from M-Bus generation: $12)

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Compact universal controllers

Compact Coded Magnetic Safety Interlock Switch and Control Units

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

T550 (UC50 ) 1. General. 3. Installation. 2. Safety Information Translation. en Installation Instructions

Millenium II +: general characteristics

Interface Module XC Level Converter / User Manual

Temperature Switches

WIRELESS RECEIVER WRM-TS. Rev. 1.0c

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

is then retained absolutely without interruption.

THREE PHASE ROUTER ELECTRONIC METER MET410...K Electric meter has the following functions: Technical information

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

QUICK-START EMU M-BUS CENTER ENGLISH

Pneumatic Control Unit for the integrated mounting on process valves

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Version-E Manual PR1a. Photocell. Manual. Page 1

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

M-BUS PROTOCOL for ML 311

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Z10 SN N Installation Manual Battery operated Length Measuring Unit

Electrical Actuators

Operating Instructions RMx621

Communicative controller for VAV systems

Magnetically Actuated Safety Interlock Switches

General information Engineering with Programming package. Display with display

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SK TU4-IOE-M12-C Part Number

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MCX08M2 Programmable controller

Wired M-Bus Modules. Data sheet. for MULTICAL 403 and 603

RT2Y Compact temperature switch intrinsic safety

Model Number Structure

Model Number Structure

Multifunction Transducer MT440

- Ovens - Food processing - Dryers, etc.

M-Bus Modules. Data sheet. for MULTICAL 403

Rotary Measurement Technology Absolute Encoders, Singleturn

Rotary Measurement Technology Absolute Encoders, Singleturn

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Andover ContinuumTM. b3850 Series Terminal Controllers

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

RelAir R2M PRO / HOME

Enermet RO. Ripple Control Receiver. Product Description. Load Management Ripple Control Systems

TECHNICAL DATA SHEET Member of Uponor Group

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Andover ContinuumTM Infinet II

Motor protection relays

Transcription:

AMBUS IS M-Bus pulse collector Applications Pulse collector for connecting meters with pulsers to M-Bus systems or transmitting status signals to M-Bus systems. These pulsers are equipped with a mechanical contact, open collector or a Namur output circuit (DIN 1924). With a 12...18 VAC or 12...24 VDC power supply. Features Pulse collector with an M-Bus interface Status signal input with M-Bus interface 12...18 VAC or 12...24 VDC external power supply Configuration a AMBUS Win Software Benefits Connecting meters with pulsers to M-Bus systems Recording status signals with M-Bus systems Maintenance-free, without batteries Easy start-up VD 9-823 e 09.2006

Product description AMBUS IS is a converter for an M-Bus interface proding binary signals to the M-Bus network. The following two applications are availae: Pulse collector application Counter M-Bus... S/N 12345678 Measuring point Counter reading When parameterised as pulse collector, AMBUS IS collects the incoming impulses from a single de-ce in a counter and allows to read the counter through an M-Bus Network. One AMBUS IS is required for every dece connected to the M-Bus in order to ensure that the measuring point is identifiae and unique. The text field (or tag) for the measuring point can easily be stored in the AMBUS IS. The M-Bus then identifies the measuring point either by the 8-character serial number of the AMBUS IS (secondary address) or by a primary address ich can be set by the operator. The input of the AMBUS IS is for a pulser with a potential-free contact, an open collector or Namur output circuit conforming to DIN 1924. A filter to eliminate the bounce of the input signal can be activated as required. This is especially recommended for pulsers with mechanical contacts (e.g. reed switches). The settings and readout are carried out using the M-Bus. The AMBUS IS itself has no display or operating keys and requires no maintenance since no alkaline or rechargeae batteries are re quired to operate it. Alarm or status collector application When parameterised as alarm collector, AMBUS IS reads a single binary signal from an dece and allows to read signal status and overall number of events through an M-Bus Network. AMBUS AS Counter... S/N 12345678 Measuring point Contact: OPEN M-Bus General features AMBUS IS can read input from a mechanical contact or an open collector or Namur output-circuit (DIN 19234). An input filter can be activated to debounce the signal (recommended for reed contacts). The measuring point designator can be entered, so it can be read by M-Bus. The data can be identified by the parametrisae primary M-Bus address, or by using the 8-digit AMBUS IS serial number as secondary M-Bus address. AMBUS IS prodes no local display or controls. Parameters can be set with a SW-tool through the M-Bus-Interface (e.g. M-Bus-Tool). 2

2 Parameters and specification Data backup With AMBUS IS, an EEPROM is used for data backup. An internal backup is performed each full hour and also on voltage interruption. This concerns mainly the counter reading, the date and the time. Parametrization AMBUS IS can be configured by means of the Software AMBUS Win, ich is availae on www.aquametro.com / Downloads with the corresponding user instruction. After completion of parametrization, this may be protected from manipulation by setting the so-called 'stop bit', and then sealing the housing cover. This prevents the stop bit from being reset. To re-parameterize a protected AMBUS IS, the stop bit may be temporarily reset. To do this, the dece must be opened. This involves breaking the safety seal and shorting the position designated as 'stop bit' on the PCB. Following reparametrization or after the change of date to the next day, AMBUS IS is automatically disaed. Parameter settings Parameter Range Default value, equivalent to alarm collector application Impulse value/unit [l for m 3 ] * 0,00001 0,0333. 10 000 1 (exclusively) Physical unit * m3, kwh, MJ oder no units no units (exclusively) Debounce filter * Activated / deactivated As for AMBUS IS Medium * Water Others Hot water Heat / hot side (The combinations "no units" and "others" define Heat / cold side the AMBUS AS) Steam Electricity Gas Oil Pressurized air Heating cost allocation scheme Others Not known Define start counter status * 0 1'000 000 ** 0 (exclusively) Text field for description of measuring Max. 32 ASCII-characters ** As for AMBUS IS point Primary bus address 0 250 As for AMBUS IS Baud rate 300 / 2400 / 9600 As for AMBUS IS Stop bit * Set / not set As for AMBUS IS Billing date DD.MM. 30.06 As for AMBUS IS Date/time DD.MM.YY hh:mm ** As for AMBUS IS Bold type designates factory default setting. * protected en stop bit set. ** Data depend on production process. 3

M-Bus data record Detailed information on the M-Bus protocol and the size of the data record returned by the standard readout (Req_UD2) of an AMBUS IS can be found in the 'M-Bus data selection' puication. Internal clock / serce hour meter AMBUS IS is equipped with a clock with calendar function and serce hour meter. The serce hour meter begins the summation as soon as AMBUS IS is connected to the grid. At this point, the clock is switched on, commencing with the time last recorded. All clocks in the appliances connected to the M-Bus can be synchronized with the AMBUS Data program. Billing date At 24.00 hours on the day designated as the billing date, the counter reading, the date and the time are recorded. This information can be read out a M-Bus. Error messages Error 7: Other error messages: Voltage too high or too low Dece failure Voltage supply The pulser is connected to a 2 pole contact. The appliance is connected to the M-Bus a the RJ-11 socket. AMBUS IS is connected to the M-Bus installation in the building, either with an M-Bus ANS-1/4 terminal point using the oval cae, or with a bus connection box using the RJ-11 round cae. When using an Aquametro M-Bus central unit and 4 pole wiring, in addition to the M-Bus connection, AMBUS IS/AS has a separate voltage supply. AMBUS ZS 62 26 27 63 230V ANS-1 ANS-4 Slave Slave Slave The instructions for installation and operation are included with each appliance. For additional informa-tion on planning an M-Bus installation, please refer to our M-Bus planning folder. 4

Technical data Supply voltage 12-18 VAC, 50/60 Hz or 12-24 VDC Current consumption <20mA Pulse input for contact open collector Namur pulser according to DIN 19234, galvanically connected to the supply Mark: <1mA / space: >2.2mA / short circuit current ca. 8mA Input frequency 0-1000 Hz Pulse duration >0.5ms, debouncing filter disaed >25ms, debouncing filter enaed Pulse line length max. 30m Contact cross-section 0.14 2.5mm 2 rigid or flexie Cae diameter max. 7.5mm Communication interface M-Bus according to EN 1434.3, potential-free Communication baudrate 300, 2400*, 9600 baud, *standard Mounting Wall mounting with two screws Ø3.5x30mm or adhesive tape Housing ASA-PC, red (UL V0) Ambient temperature 5-55 C Protection class / weight IP40 / 0.065kg Dimensions H=67, W=60, D=28mm (see dimensional diagram) Functional elements and connections 7 8 10 1 2 12 3 4 5 6 1 Reserve 2 12..18VAC 3 M-Bus 4 M-Bus 5 12..18VAC 6 Reserve (-) ws (-) tk (-) (+) (+) (+) 3 4 CH-4106 THERWIL Impulssammler Art.Nr: 93533.00 Input: Namur (DIN 19234) Output: M-Bus (EN 1434-3) S/N: 1234567 ; 1998 6 11 1234567 9 5 4 10 Legend 1 Housing cover 2 Lower housing 3 Housing screw 4 Retaining holes 5 Safety seal (applied to housing screw) 6 Labeling 7 Pulser cae entry 8 M-bus connection entry 9 Pulse input terminal 10 RJ-11 socket, M-Bus connection 11 'Lock bit' switching area (LOCK) 5

Overall dimensions 60.0 67.0 48.0 Impulssammler CH-4106 THERWIL Art.Nr: 93533.00 Input: Namur (DIN 19234) Output: M-Bus (EN 1434-3) S/N: 1234567 ; 1998 28.0 max. Ø 7.5 mm M-Bus 9.5 10.0 40.0 Ordering information AMBUS IS Art. No. 93533 Oval cae 1.5m with RJ-11 connectors at both ends Art. No. 81589 Aquametro M-Bus accessories for installation ANS-4/DIN ANS-4/AP ANS-1/AP ANS-1 RJ-11 cae M-Bus distributor M-Bus distributor, M-Bus M-Bus cae 4x RJ-11 sealae connecting box connecting box 1x RJ-11 2x4pole terminals 4x RJ-11 1x RJ-11 1x RJ-11 2x RJ-11 2x4pole terminals CH-4106 Therwil ANS-4/AP ANS1/AP Vi tk ws CH-4106 Therwil Aquametro M-Bus software AMBUS Data: Readout and data export from M-Bus installations For further information on the above products, please contact our sales department. 6

Maintenance This equipment requires no maintenance. Standards All appliances are certified according to CE and product standards requirements. Data transmission accords with EN1434-3:1997. 7

Änderungen vorbehalten / Sous réserve de modifications Modification rights reserved / Copyright AquametroAG AQUAMETRO AG AQUAMETRO SA AQUAMETRO AQUAMETRO AQUAMETRO s.r.o. MESSTECHNIK GmbH BELGIUM SPRL Ringstrasse 75 Rue du Jura 10 Zum Panrepel 24 Dallaan, 67 Prosecká 811 / 76a CH-4106 Therwil CH-1800 Vevey D-28307 Bremen B-1933 Sterrebeek CZ-190 00 Praha 9 Phone 061 725 11 22 Phone 021 923 51 30 Phone 0421 / 871 64-0 Phone 02 / 241 62 01 Phone 02 / 86 88 77 78 Fax 061 725 15 95 Fax 021 922 58 44 Fax 0421 / 871 64-19 Fax 02 / 216 22 63 Fax 02 / 86 88 95 59 info@aquametro.com info@aquametro.com info.amd@aquametro.com info.amb@aquametro.com info.amc@aquametro.com www.aquametro.com A0 5 09 2006 Art Nr 11747