WIRELESS ENVIRONMENTAL MONITORS

Similar documents
Monitoring Made Easy. October 2015 APRIL 2015

EnergyLok Environmental Monitoring System 300 Product Training. Stephanie Christensen National Account Manager 03/24/16

Automation Monitoring Control. EDN 2010 Hot 100

84 kw, Tier 3, Direct Expansion, 937 ft 2

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Ubiquiti UniFi UAP-Pro Access Point

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Recapture Capacity for Existing. and Airflow Optimization

8-Outlet eco PDU PE6208AV

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Polar PDUs POWER MANAGEMENT

Data Center Infrastructure Management (D.C.I.M.)

Comprehensive Data Center Energy Management Solutions

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Product Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)

MP7. Uninterruptible Power Supply

Thermal management. Thermal management

Supplementary Components WirelessHART products

Geist EMEA. Geist USA. Geist APAC

Technical Manual Nova: Cabinet Security Management System (CSMS)

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

GAMATRONIC, A SolarEdge Division.

Efficiency of Data Center cooling

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

CEEVA-Mesh MR Series

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

V C. Automatic Ethernet Fail-over Failover Switch ALIANT OMMUNICATIONS. 1. Product Overview

Power and Cooling for Ultra-High Density Racks and Blade Servers

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Installation Job Aid for VSP 4450GTX-HT- PWR+

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Features and Benefits: Power IQ DCIM Monitoring Solutions

PDU - Overview / Non-Intelligent PDU s

Application of TileFlow to Improve Cooling in a Data Center

ECO PDU PE7108/PE7208

G5 PDU Installation Guide

WIRELESS TRANSMITTER DUOS TEMP 868MHz

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

300Mbps Wireless N Ceiling Mount Access Point

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

ECO PDU PE5108/PE5208

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

TOXALERT MODEL AIR 2000

INNOVATE DESIGN APPLY.

Madrid, 25 y 26 de mayo de 2015 ABB Automation Days Wireless Instrumentation

INNOVATE DESIGN APPLY.

IS.3. Post Top Module (PTM)

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Installation Job Aid for VSP 4850GTS

APC Next Generation Rack ATS

Cisco MCS 7825-I1 Unified CallManager Appliance

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

A Series Enterprise WiFi that just works.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

A Series Enterprise WiFi that just works.

ECO PDU. Features. PE5220sA

Self-Contained Equipment Cabinets

Eaton Open Data Centre Solutions. Kari Koli

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

A62 Access Point. Enterprise Wi-Fi that just works. Netsurion makes Wi-Fi smarter and simpler. Diverse solutions

Data Center Infrastructure Management (DCIM) Demystified

POWER CABLES FOR MISSION CRITICAL FACILITIES

Owlet IoT Wireless Outdoor Luminaire Controller LUCO P7 CM (cellular-mesh) Datasheet. Streetlight controls for smart cities based on IoT Technology

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

WIRELESS TRANSMITTER DUOS CO 2

Monitoring system LN-VT325. Environmental Infrastructure monitoring

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Accsense Wireless System. Temperature Monitor

Fast Route to Reliable Energy Savings ZIP Economizer

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Zenith Series DPB Distributed Power Busway

300Mbps Wireless N Gigabit Ceilling Mount Access Point

Yanzi IoT for Smart Buildings From Sensor to Cloud. Marie Lassborn, VP Cloud Operations Jfokus 2018

Meter Scanner & Controller

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

MID approval no. DE-08-MI004-PTB004 Date of release

ROOM GUARD VT335. Environmental Infrastructure monitoring

Reducing Data Center Cooling Costs through Airflow Containment

Schneider Electric Easy UPS 3S

A42 Enterprise WiFi that just works.

Performance, Design, and Versatility MT8000iE XE mtv ip Series

TELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia

Zone Pressure Touch (ZPT) Sensor - Standard Range

STULZ Digitronic software Complete control for more reliability and maximum efficiency in data centers

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

Ruckus ZoneDirector 1106 WLAN Controller (up to 6 ZoneFlex Access Points)

Total Modular Data Centre Solutions

VLT Micro Drive. Ready Set Go!

DMT345 and DMT346 Dewpoint Transmitters

Preconfigured SCADA solution: Easy & Powerful

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

Transcription:

Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless monitoring nodes 2 New devices automatically join 3 where you need them the network Access data instantly FEATURES Humidity Measure up to 12 temperature points per monitor Low cost per monitoring point Each monitor can cover one to 12 cabinets based on your needs Monitors temperature, differential pressure and humidity High precision measurement Monitoring that adapts to your needs The highly flexible system lets you gather temperature data from 1 to 12 points per cabinet. Increase the number of points per cabinet to gain detailed insight into high-heat cabinets and scale it back to lower monitoring costs in low-heat areas. Customize the length of the temperature probes to perfectly match your monitoring strategy or use pre-configured probe kits to maximize ease of installation; And add relative humidity and differential pressure monitoring just where you need it Probe Location AC or battery powered Enables real-time facility heat maps Scalable to thousands of monitoring points per facility Minimizes IT resource requirements Isolates monitoring devices from primary data networks Instant access to data locally or using our cloud service Easy integration with third party BMS and DCIM systems Built on wireless technology proven to work in critical facilities Low Density Cabinet: 1 probe per cabinet Standard Cabinet: 3 probes per cabinet High Density Cabinet: 6 probes per cabinet

Environmental Monitor Models E306-0000 Up to 6 temperature probes Relative humidity Dry contact status AC powered or PoE w/ splitter Packet Power Architecture E306-P000 Up to 6 temperature probes Differential pressure Dry contact status AC powered or PoE w/ splitter * MONITORS Battery E312-H000 Up to 12 temperature probes 2 year battery life Battery status reporting Optional AC power Optional relative humidity SNMP MODBUS DCIM / BMS THIRD PARTY INTERFACE 1-15m Probes Use easy to install pre-built kits or buy individual probes in lengths up to 15m * GATEWAY POWER MONITORS EMX ENERGY PORTAL Packet Power makes it easy to manage your monitoring network. The Ethernet Gateway automatically detects any new monitoring devices, seamlessly adding them to the network. The monitors communicate via a mesh network routing traffic through any nearby monitors to find the optimal path to a Gateway. This robust and resilient technology results in a wireless network that is as reliable as a wired network but much easier to install, manage and secure. Gateways, which can each support up to 300 monitoring units, can be added to expand capacity and provide redundancy. * Battery powered devices can transmit through the relay network but can not act as a relay nodes. Packet Power Wireless Monitor Family Three phase power monitor for busway, PDUs and underfloor whips Smart Cables : Three phase power cables with embedded wireless monitoring from 16 to 63A Smart Cables : Single phase power cables with embedded wireless monitoring from 10 to 63A Multi-Circuit Panel: Monitors up to 9 three phase circuits

Delivering the information you need Access monitoring data from your existing DCIM application or use Packet Power s EMX Energy Portal to quickly and easily gain insight into how your facility is performing. EMX provides useful data instantly without the need for expensive consultants or lengthy customization and can be easily tailored by you as your needs evolve over time. With full support for real-time heat maps, enterprise-level alerts, and in-depth reporting, it provides a monitoring system that is high on capability but low on complexity. You can either run EMX at your site or just sign in to Packet Power s cloud service. How Packet Power monitoring can help you Ambient and Relative Humidity Plenum Air Pressure and CRAC Ouput Air Pressure and Rack Air Pressure and Perforated Tile Air Pressure and Aisle Underfloor Air Pressure and Packet Power Environmental Monitors provide a detailed picture of heat, humidity and air flow in your facility. The information can be used to: Identify wasted or misdirected air flow Optimize flow and focus cooling on areas where most needed Verify the effects of containment systems and other air handling efficiency efforts Be alerted to changes that may indicate potential performance problems Avoid damage to equipment from overheating Safely raise ambient temperature Ensure compliance with industry guidelines Easily correlate pressure and temperature changes

MEASUREMENT Relative Humidity Dry Contact COMMUNICATIONS Operating Frequency Wireless Network Protocol Data Output Firmware Updates Typical Transmission Range Antenna Monitoring Unit to Gateway Radio Multi-site Support Encryption System Status ±1 C at 0.1 C resolution with readings in C or F. From 0 to 100% RH at ±2 % RH at 0.1% resolution Contact Packet Power for specific sensing devices ±500 Pa (±2 H 2 0), 0.2Pa or ±3% accuracy full span OPERATING ENVIRONMENT / MECHANICAL / POWER SUPPLY Operating Operating Humidity Water and Dust Resistance Module Size and Weight (E306) Module Size and Weight (E312) Batteries (E312 only) External AC Power Supply Power Supply Plug Types 860 to 920MHz and 2.4 GHz (frequencies vary by region) Frequency hopping self-configuring load-balancing mesh SNMP and Modbus TCP/IP protocols Wireless 10 to 30 meters indoors between any two devices in mesh network Fully enclosed, fixed configuration Up to 300 monitoring units per gateway and unlimited Gateways per site Yes 128-bit Local LCD display on E306 models Monitoring Unit: 0 to +40 C (+32 to +104 F) probes: -40 to +85 C (-40 to +185 F) 10% to 90% non-condensing NEMA 1 / IP20 (indoor use) 65 mm (2.6 ) x 65 mm (2.6 ) x 28 cm (1.1 ), 90 g (3 oz) 80 mm (3.1 ) x 53 mm (2.1 ) x 40 cm (1.6 ) (3 oz; 5 oz with batteries) 2 x AA (included) 100-240 VAC input voltage, 50-60Hz / 5 VDC output ; 0.5 W power consumption C14, NEMA 1-15, Euro CEE 7/16, ANZ AS 3112, China GB 2009, UK BS1363, India BS546 MONITORING MODULES Max. Relative Differential Power Mounting Model Probes Humidity Pressure AC Battery Bracket E306-0000 6 N N Y N Optional E306-H000 6 Y N Y N Optional E306-P000 6 Y Y Y N Optional E312-0000 12 N N Opt. Y Standard E312-H000 12 Y N Opt. Y Standard TEMPERATURE PROBE ASSEMBLIES Probes Racks Per Total Use with Model per Rack Monitor Probes Probe Lengths Monitor TP03-01X6 1 6 6 1x 3m, 4x 4m, 1x 5m E306 TP03-02X3 2 3 6 1x 2m, 3x 3m, 2 x 4m E306 TP03-03X2 3 2 6 1x 1m, 2x 2m, 2x 3m, 1x 4m E306 TP03-06x1 6 1 6 2x 1m, 2x 2m, 2x 3m E306 TP03-06X2 6 2 12 2x 1m, 5x 2m, 3x 3m, 2x 4m E312 TP03-04X3 4 3 12 2x 1m, 4x 2m, 2x 3m, 4x 4m E312 TP03-03X4 3 4 12 1x 1m, 3x 2m, 4x 3m, 4x 4m E312 TP03-02X6 2 6 12 1x 1m, 2x 2m, 4x 3m, 4x 4m, 1x 5m E312 INDIVIDUAL TEMPERATURE PROBES PROBE EXTENDERS Model Length Model Length TPP3-001M 1 m TPP3-X02M 2 m extension cable TPP3-002M 2 m TPP3-X04M 4 m extension cable TPP3-003M 3 m TPP3-X09M 9 m extension cable TPP3-004M 4 m Maximum probe length is 15m Packet Power, 2716 Summer St. NE, Minneapolis, MN, 55413 USA Tel: 877-560-8770 - Fax: 866-324-2511 www.packetpower.com

From installation to monitoring in minutes Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. The wireless and battery powered monitors let you can locate sensors exactly where they are needed. Installation is further simplified by a self configuring network that automatically adds new devices. 1 Place monitoring nodes where you 2 New devices automatically join 3 need them (wireless) the network Immediate access to data FEATURES Humidity Measure up to 12 temperature points per monitor Low cost per monitoring point Captures up to 12 sensor readings per monitor Monitors temperature, differential pressure and humidity High precision measurement (±1 C, ±2% RH, 3% pressure) Multi-zone thermal monitoring advantages Traditional rack thermal monitors look at only a single point, missing the true thermal picture of your rack. Using the Packet Power multi-point sensor system, you can reveal critical hot spots and accuractely identify your thermal range. These temperatures are instantly translated to an easy visual reference using the Packet Power EMX Portal. AC or battery powered options Enables real-time facility heat maps; easy mapping of temperature readings to facility layout diagrams Scalable to thousands of monitoring points per facility Minimizes IT resource requirements Isolates monitoring devices from primary data networks Server Rack (side view) 3D Thermal Map showing rack temperatures for each zone Pre-configured probe kits simplify installation by providing the correct lengths of probes for your specific installation. A single monitor can measure one to 12 racks depending on the required sensor density. High Resolution: 6 probes per cabinet Standard: 3 pobes per cabinet Low Heat: 2 probes per cabinet Instantly connects with EMX monitoring solution (cloud based or local application) Easy integration with third party BMS and DCIM systems (ModBus TCP/IP or SNMP output) Built on wireless technology proven to work in critical facilities