Technical Notes for Ocularis 5.5

Similar documents
Technical Notes for Ocularis 5.3

Technical Notes. Smarter Surveillance for a Safer World

Recorder Proxy Configuration Guide

Technical Notes for Ocularis 4.0

Technical Notes for Ocularis 5.1

Mobile User Guide. Smarter Surveillance for a Safer World

How to Configure Ocularis OpenSight

Mobile User Guide. Smarter Surveillance for a Safer World

Upgrade Manual. Smarter Surveillance for a Safer World

Ocularis Administrator. User Manual On-Net Surveillance Systems Inc.

Mobile User Guide. Smarter Surveillance for a Safer World

OnSSI C CURE 9000 Video Integration

Ocularis Administrator. User Manual On-Net Surveillance Systems Inc.

Table of Contents. Product Overview 3 System Requirements 4 Installing MicroView 5 Managing Users & Groups 8

Admininstrator User Manual

Media Server Installation & Administration Guide

Ocularis Viewer User Manual

Avigilon Control Center Standard Web Client User Guide. Version 5.6

OnView Mobile Monitoring

Maplewood ConnectEd Teacher s Manual For Secondary School

Administrator User Manual

Avigilon Control Center Enterprise Web Client User Guide. Version 5.8.4

Ocularis DS. The Platform for IP Video Management. Installation & Administration User Manual

Harvard Phone. Introduction to Contact Center CONTACT CENTER CLIENT QUICK REFERENCE QUIDE

VMS-A1 Client Software. User Manual

Central Management Software. Cam Viewer 3 Lite. User Manual

Viewer User Manual. Smarter Surveillance for a Safer World

Ocularis. Installation & Licensing Guide

Managing Your Website with Convert Community. My MU Health and My MU Health Nursing

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

RITIS Training Module 4 Script

Working with Mailbox Manager

SkyPoint Administrator. User Manual

Manual Version: V1.15. Video Management Software Guard Station User Manual

Ocularis Web User Guide

Avigilon Control Center Web Client User Guide

Managing Video Feeds. About Video Feeds CHAPTER

Video Management Software

Genie XMS Central Management Software

Quick Start Guide. Smarter Surveillance for a Safer World

S2 NetBox v4.8 Basic End-User Admin Training

Table of Contents Surveillance Center Overview...3 Log...30 Live Camera Panel...31 Live Camera Panel Explained I...32

HOSTED VOIP COMMPORTAL GUIDE

Configuring and Managing the IP Camera

ALIBI Witness 2.0 v3 Smartphone App for Apple ios Mobile Devices User Guide

Manual Version: V1.01. ISS Manager Video Management Software User Manual

NetGuard EVS Learning Guide

Scheduling Module Client Booking Quick Guide Online-Scheduling

Avigilon Control Center Enterprise Client User Guide. Version 5.8

Remedy ITSM Quick Start Guide

Creating Fill-able Forms using Acrobat 7.0: Part 1

icms Pro USER S Manual Ver 1.4

InformationTechnology

Infinova 2217 Security Management System Client User Guide

Guide VIGIL Server Quick Start Guide

Configuration Database Backup Guide

B3223P23 Release Notes. Zhejiang Uniview Technologies Co., Ltd.

CME E-quotes Wireless Application for Android Welcome

Client User Manual. Smarter Surveillance for a Safer World

Cisco Unified Personal Communicator Release 8.5

+ milestone. Milestone Systems. Milestone Mobile client 2017 R3. User Guide

Senstar Symphony. 7.1 User Guide

Setup Smart Login for Windows V2

Mirasys NVR. User s Guide


Milestone Systems. Milestone Mobile client 2017 R1. User Guide

Agent and Agent Browser. Updated Friday, January 26, Autotask Corporation

Investigator Site OC RDC PDF User Guide

ScholarOne Abstracts. Review Administrator Guide

Avigilon Control Center Standard Web Client User Guide. Version 5.4

Recorder Database Management Guide

Pro7400H1 Hybrid DVR User Manual

version 7.6 user manual

How to Use exacqvision with Hikvision Devices V2.0.1

AVID Reports. User Manager

Milestone Paxton Integration Component User s Manual

Video Monitoring. Contents CHAPTER

IP WEB User Manual V2.0

NetEVS 2.0 Getting Started Guide

Polycom Converged Management Application (CMA ) Desktop for Mac OS X. Help Book. Version 5.0.0

Layout and display. STILOG IST, all rights reserved

1 Log into DIGIOP Control

Pro71600N3 NVR User Manual

Multi-NVR Manager. Quick Start Configuration Usage

CompleteView Admin Console User Manual. CompleteView Version 4.6

Overview CMS2. Features. Minimum System Requirements (Single site mode) Preferred System Requirements (Multi-site mode) What is CMS2?

USER MANUAL. Mac Version

Maplewood ConnectEd User Guide For AMDSB Elementary Teachers Grades 1 to 8

Unisight DVR System. Unisight DVR Manual. Ver rev1.3.4

AGENT123. Full Q&A and Tutorials Table of Contents. Website IDX Agent Gallery Step-by-Step Tutorials

Viewing Reports in Vista. Version: 7.3

Avigilon Gateway Web Client User Guide. Version 6.10

Pro7804N1 NVR User Manual

Avigilon Control Center 5.6 Release Notes

Video Monitoring. Contents CHAPTER

Using the VSOM Operator Pages

EASI MP-X Series. User Manual EASI MPR. Workstation. MPR Workstation user manual, , rev003

Web-based Configuration. First, setup motion detection windows in the web-based configuration of the camera.

Chapter 3 Operating instructions

HIP2P Network Video Camera Client Terminal User Manual

Transcription:

The purpose of this document is to provide technical details for various new features in the Ocularis 5.5 release. Topics in this Document Camera Health Status... 1 Camera Status Indicators... 2 Automatic Server Refresh... 3 Smart Event Communication... 4 Increased Security with Ocularis Recorder Proxy... 5 Ocularis Client Automatic Update... 6 Streaming On Demand... 8 Streaming - Always... 8 Streaming - On Demand - Quick Stream Start... 9 Streaming - On Demand... 10 Using Triggers to Control Streams... 10 Adjustable Column Width in Ocularis Recorder Manager... 14 Camera Health Status As you know, cameras can sometimes go offline without you realizing it. Administrators now have a way to obtain a real-time update of the health of the cameras on their system via a new System Status Tab in Ocularis Administrator. Figure 1 System Status Tab On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 1

In this tab, you'll see groupings of three statuses: Offline, Disabled and Online. This screen is updated in real-time. You can expand or collapse a group by clicking the arrow icon on the right of the group name or on the heading itself. There is a filter field in the upper right that allows you to use a keyword to help you locate a particular camera by its name. Lastly, you can export the list of cameras and their status by clicking the 'Export' button. A pop-up allows you to select which cameras you'd like included in the report. You can specify a location for the resulting.csv (comma separated values) file and then click Export. Open the file with any text editor or Microsoft Excel to view the contents. This feature is only available to the admin user or other users in the 'Administrators' user group. Is it not available to Group Administrators. CAMERA STATUS INDICATORS Another place where administrators can get an update of their system health is from the Ocularis Administrator Servers / Events tab. If you expand the Cameras list, you will see an update on the status of your cameras. Cameras that are disabled appear 'grayed out'. Cameras that are offline appear with the icon: camera is disabled camera is offline Figure 2 Camera Status Info This feature is available to only user accounts in the 'Administrators' group. The status of cameras update in real-time. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 2

Automatic Server Refresh Whenever a change is made on a recorder that requires a refresh in the Base, Ocularis Administrator will perform an automatic refresh of the affected server. This is actually controlled by the Ocularis Recorder Proxy (formerly called 'Ocularis Event Proxy') and is equivalent to a user right-clicking a server name and selecting 'Refresh Server' in the Ocularis Administrator 'Servers / Events' tab. Once a recorder change is made (e.g. a new camera is added, camera name changed, etc.), the Ocularis Recorder Proxy is aware of this change. It will then instruct Ocularis Administrator to refresh the applicable server. The recorder changes that will cause the Base to automatically refresh include: Adding a device or adding an additional camera from a multi-channel device Renaming a device (at the top level name only; does not apply to renaming a camera name for a multi-channel device) Deleting a device Adding, modifying or deleting a camera stream, however, will be silently updated by the Ocularis Recorder Proxy. These do not require a recorder refresh on the Base. When the first change is made, a refresh is immediate. On larger systems, however, this could take up to a minute. If the Ocularis Administrator application is open and you want to see the change either click the 'Resync' button in the Events pane or switch tabs. To prevent too many automatic refreshes, subsequent recorder changes will not immediately force a refresh if performed within five minutes of the first change. Once the second change is made on the recorder, a five minute timer starts and a blue highlight will pulse over the server name in the Servers / Events tab to indicate that a Recorder refresh is pending (see Figure 4 below). If another change is made on the recorder, the timer is reset at five minutes from that point on and so on. You can wait until the system does the refresh automatically or you can perform a manual refresh by right-clicking the server name and selecting 'Refresh Server'. If a manual refresh is performed, the scheduled automatic refresh is cancelled. Figure 3 Recorder refresh is pending In order for this feature to work, the checkbox 'Auto Update Recorder on Ocularis Base' must be checked inside the Ocularis Recorder Proxy, under Base Settings for each server. This feature is enabled by default. Note: If a camera name is changed on the recorder, this feature will automatically update it in the Servers pane of Ocularis Administrator. However, the camera name change will not be reflected in the Events pane. The event will continue to work, however, even with the outdated name. To correct this, restart the Recorder Proxy. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 3

Smart Event Communication In addition to changing its name, there have been additional important changes to the Ocularis Recorder Proxy. The way the Proxy communicates with Ocularis Base is now more intelligent and efficient. When you select one or more events in the 'Event Selection' list on the Ocularis Recorder Proxy, the Proxy is able to determine whether Ocularis Base actually has any of the selected events configured. Figure 4 Ocularis Recorder Proxy Event Selection For instance, in the example shown above, we've selected five events: Camera Offline - Initial Camera Side Generic Events Camera Side Motion Detection Camera Tampering - Camera Based Camera Tampering - Server Based Based on the selections in this list the Ocularis Recorder Proxy then checks with Ocularis Base to see if any cameras have mappings associated with these events. In other words, do any cameras have Camera Offline - Intial configured, Camera Side Generic Events configured and so on. If they do, the Proxy will send ONLY these events. If, for example, there are no cameras mapped to the 'Camera Tampering - Server Based' event, even though it is selected here, the Proxy will not send any data to the Base regarding this event. In prior versions, the data would be sent even if the event was not configured on any camera on the Base. This can significantly improve performance on the Base. It can also result in huge savings in network bandwidth, especially in larger systems. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 4

Increased Security with Ocularis Recorder Proxy The Ocularis Recorder Proxy now requires account credentials to authenticate permission with Ocularis Base. This prevents just anyone from configuring a rogue recorder to transmit events (and streams, etc.) to any Base. When you configure the Ocularis Recorder Proxy for the first time or when you upgrade, you need to provide a Username, Password and Authentication type for an administrative account on that Base. You must validate the credentials by clicking the 'Test Authentication' button. Only then are you able to continue with the Proxy configuration. Figure 5 Authenticate Ocularis Base Keep in mind that credentials must be provided for each Base configured. In the case of an upgrade, you'll be asked to provide these credentials before the upgrade software is installed. If the credentials are incorrect or you elect not to provide them during the upgrade, the software installation will be aborted. The existing Proxy software remains intact. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 5

Ocularis Client Automatic Update Certain changes made on the recorder or Base require that Ocularis Client be restarted. This is done by the operator selecting 'Log off' and then logging back on. The automatic update feature provides the flexibility to have Ocularis Client be restarted for you. Figure 6 Server Update Behavior This behavior is configured on each Ocularis Client PC and will affect all users logging in to that PC. Configure the setting in Ocularis Client by selecting Views...Client Setup. The options are located in the drop-down list on the 'Display' screen under 'Server Update Behavior' and include: Ignore Auto-Restart Inform Ignore If 'Ignore' is selected, the operator will not be notified of any potential changes that require an Ocularis Client restart. This is the behavior that existed pre-version 5.5. Auto-Restart If 'Auto-Restart' is selected, a pop-up appears stating that a change was made and Ocularis Client must be restarted to take advantage of the change. Figure 7 Auto Restart If you do nothing, the Client will close and restart by itself when the timer runs out. You can click 'Restart Now' to immediately initiate the restart. Clicking 'Cancel' aborts the restart. The message will not reappear unless additional changes are made that would require a restart. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 6

Note: Inform Technical Notes for Ocularis 5.5 If there is an export in progress, this pop-up will not appear right away. The message 'Server Settings Have Changed' is displayed in the upper left portion of the screen. Once the export is complete the pop-up will appear, allowing you to restart the Client to take advantage of any server based changes made. This is the default setting. When a change is made on the recorder or Base that could affect the operator's use of Ocularis Client, a message 'Server Settings Have Changed' appears in the upper left portion of the Ocularis Client screen. The change could be anything from a new view, a new camera in an existing view, a new camera stream, PTZ presets and more. The actual change is not displayed in the message. The operator has the option to restart Ocularis Client (i.e. log off and log back in) in order to take advantage of the new settings. The message appears for about 10 seconds and then disappears. It will reappear every ten minutes until the Client is restarted. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 7

Streaming On Demand Some new settings have been introduced on the recorder related to a camera's stream. Through the Stream audio/video option on the camera configuration screen you can determine whether a camera's stream is always streaming to the device manager or whether you want to reduce network traffic and only stream video when you need it. Similarly, you have the option to stop the stream as well. This feature is commonly used in interview or interrogation rooms or anytime a meeting needs to be completely private. Not streaming video from a camera can also reduce network traffic and is especially useful in LTE environments. This feature applies to all streams from the camera. When a stream is stopped, video is not recorded nor available live to any client user. Audio is also not recorded or transmitted. There are three options for the Stream audio/video field: Always (introduced in v5.0) On Demand - Quick Start (introduced in v5.3) On Demand (introduced in the August 2017 recorder patch update for R10) Figure 8 Stream audio/video STREAMING - ALWAYS When the Stream audio/video drop-down is set to 'Always', the default value, live video streams from the camera to its assigned device manager. If Standard Recording is set to 'Yes' and the recording period is set to 'Always', the camera streams 24/7/365 and cannot be turned off manually. If configured, video is recorded to its corresponding zone(s) and sent to any authorized client (Ocularis Client, Ocularis 5 Web or Oculari 5 Mobile) seeking to view it. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 8

Figure 9 Streaming - Always STREAMING - ON DEMAND - QUICK STREAM START When the option On Demand - Quick Stream Start is selected, video streams from the camera to its device manager but is then discarded. In Ocularis Client, a view pane with this camera appears empty with the message 'Camera connection lost' when a view with the camera is displayed. If an operator wants to view video from that camera, he/she must manually request it from a client by alarm scenario or executing a manual event (such as a trigger). Once the stream is enabled, it can be recorded (if configured to do so) or displayed to any client requesting it. The stream remains active until disabled via another event (either manual or automated). Figure 10 Initally, device manager discards video data On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 9

Figure 11 Operator can manually request video via trigger Figure 12 Once requested, video flows to clients and/or recorded to zone(s) STREAMING - ON DEMAND When the option On Demand is selected, video does not stream from the camera to its device manager. A view pane with this camera appears empty with the message 'Camera connection lost' when a view with the camera is displayed. If an operator wants to view video from that camera, he/she must manually request it from a client by alarm scenario or executing a manual event (such as a trigger). Once the stream is enabled, it can be recorded (if configured to do so) or displayed to any client requesting it. The stream remains active until disabled via another event (either manual or automated). Since the video when using the 'On Demand' option does not stream from the camera to the device manager by default, network traffic is reduced. This feature is also useful if transmitting camera video via wireless over broadband. USING TRIGGERS TO CONTROL STREAMS In order to take advantage of the On Demand streaming function, you need a mechanism to be able to start or stop the live stream. This is done by using a trigger or alarm scenario. Triggers may be camera specific or global. Camera Specific Triggers Camera specific triggers may be used to disable or enable a stream set to 'On Demand' or 'On Demand Quick Stream Start'. These triggers are available for use (given permission) with Ocularis Client, Ocularis Web and Ocularis Mobile. They are On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 10

accessible via the 'aux' menu on the camera pane in Ocularis Client. For Ocularis Web, they appear when the trigger icon in the camera's pane is selected. For Ocularis Mobile, a list of camera specific triggers appears when the camera is selected (you may have to swipe left or right in portait mode to view the list). To Create a Camera Specific Trigger These steps assume that the camera's stream mode is already set to 'On Demand' or 'On Demand Quick Start'. (see Figure 9). 1. Using Ocularis Recorder Manager, select 'Triggers' from the Control Bar and create a new trigger by clicking the 'Create new object' tool. 2. Provide a name for the trigger. Keep in mind this is the label that is visible in a client. It should be as descriptive as practical and will be listed in the order in which it is created. You will create a trigger to start or enable the stream as well as to stop or disable the stream. Click OK. 3. If you want to change the icon that will appear adjacent to the trigger in Ocularis Recorder Manager, select it from the Icon drop-down menu. This is optional. 4. Click the checkbox for 'Specific camera'. 5. Select the camera you are configuring. 6. Next, select 'Action' on the left panel. 7. Select the 'Perform action' radio button which enables a Select button. 8. Click the Select button. 9. Expand the camera you are configuring. You should see an entry to 'Disable stream' and to 'Enable stream'. Select one of these and click OK. 10. Click Save to save changes and close the tab. 11. Repeat these steps to create a second trigger to start or stop the stream. 12. Once all triggers have been created, perform a manual refresh on the recorder within Ocularis Administrator (rightclick and select 'Refresh Server'). To Use a Camera Specific Trigger From Ocularis Client, select the 'aux' overlay icon in the camera's view pane to access the enable or disable stream trigger. From Ocularis Web, the trigger appears when the trigger icon is clicked from within the camera pane. From Ocularis Mobile, select the camera and view the camera specific triggers after selecting a camera for viewing. Note: Since a camera set to 'On Demand' or 'On Demand Quick Start' will initially be disabled, the 'aux' overlay icon in Ocularis Client will not be initially visible. Therefore, it is recommended to also set a Global Trigger to enable a camera. See instructions below. Global Triggers Global triggers may also be used to disable or enable a stream set to 'On Demand' or 'On Demand Quick Stream Start'. These triggers are available for use (given permission) with Ocularis Client and Ocularis Web. They are accessible via the 'Triggers' menu in Ocularis Client. For Ocularis Web, they are accessed from the Triggers icon in the Task Bar. To Create a Global Trigger These steps assume that the camera's stream mode is already set to 'On Demand' or 'On Demand Quick Start'. (see Figure 9). 1. Using Ocularis Recorder Manager, select 'Triggers' from the Control Bar and create a new trigger by clicking the 'Create new object' tool. 2. Provide a name for the trigger. Keep in mind this is the label that is visible in a client. It should be as descriptive as practical and will be listed in alphabetical order in the menu list. Therefore, you may want to prepend the name of the trigger with the name of the camera such as: Camera 1234 - Start Stream On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 11

Camera 1234 - Stop Stream This naming convention will group the triggers for the camera together. Technical Notes for Ocularis 5.5 You can create a trigger to start or enable the stream as well as to stop or disable the stream. Click OK. 3. If you want to change the icon that will appear adjacent to the trigger in Ocularis Recorder Manager, select it from the Icon drop-down menu. This is optional. 4. Next, select 'Action' on the left panel. 5. Select the 'Perform action' radio button which enables a Select button. 6. Click the Select button. 7. Expand the camera you are configuring. You should see an entry to 'Disable stream' and to 'Enable stream'. Select one of these and click OK. 8. Click Save to save changes and close the tab. 9. Repeat these steps if you want to create a second trigger to start or stop the stream. 10. Once all triggers have been created, perform a manual refresh on the recorder within Ocularis Administrator (rightclick and select 'Refresh Server'). To Use a Global Trigger From Ocularis Client, select the 'Triggers' menu when in Live mode. Expand 'Global Triggers'. Select the global trigger from the displayed list. From Ocularis Web, the trigger appears when the global trigger icon is clicked from the Task Bar at the bottom of the screen. Using Global Triggers to Control Multiple Cameras You may wish to enable or disable a group of cameras at the same time. For instance, if you have multiple cameras in a conference room and have a private meeting, there is a way to disable all cameras in one step. (Conversely, you can enable them in one step as well). In this case, you need to configure an alarm scenario to disable or enable the cameras and then create a trigger for each scenario. 1. The first step is to create the alarm scenario. From Ocularis Recorder Manager, select 'Alarms' from the Control Bar and create a new alarm scenario by clicking the 'Create new object' tool. 2. Provide a name for the scenario such as 'Conference Room A - Enable All Cameras' and click OK. 3. If you want this feature available at only designated times, change the 'Validity' period by selecting another Time profile. Otherwise, it will be available 'Always'. 4. Click 'Server' from the left panel. 5. Click the Edit button under 'Actions at start of alarm'. 6. For each camera you wish to configure, expand it in the pop-up and select 'Enable stream'. This assumes that you have already configured the camera's stream mode to 'On Demand' or 'On Demand Quick Start'. (see Figure 9). You may select as many cameras as necessary. When done, click OK. 7. Click Save. 8. Repeat the above steps for an alarm scenario to disable the same cameras. 9. When done, create a new Trigger for each alarm scenario. Select 'Triggers' from the Control Bar and create a new trigger by clicking the 'Create new object' tool. 10. Provide a name for the trigger. Keep in mind this is the label that is visible in a client. It should be as descriptive as practical and will be listed in alphabetical order in the menu list. Therefore, you may want to prepend the name of the trigger with the name of the camera such as: Conference Room A - Disable All Cameras Conference Room A - Enable All Cameras This naming convention will group the triggers for the camera together. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 12

You can create a trigger to start or enable the stream as well as to stop or disable the stream. Click OK. 11. If you want to change the icon that will appear adjacent to the trigger in Ocularis Recorder Manager, select it from the Icon drop-down menu. This is optional. 12. Next, select 'Action' on the left panel. 13. Select the 'Start alarm scenario' radio button which enables a drop-down menu. 14. Select the corresponding alarm scenario from the list. 15. Click Save to save changes and close the tab. 16. Repeat these steps if you want to create a trigger to start or stop the streams. 17. Once all triggers have been created, perform a manual refresh on the recorder within Ocularis Administrator (rightclick and select 'Refresh Server'). Alerts with Streams If you want to be notified when a camera stream is enabled or disabled, you may do so using a new event for this in the 'Event Filters' list of the Ocularis Recorder Proxy. Under 'Camera Events' you can select 'Disable Stream' and / or 'Enable Stream'. You still need to configure the event using Ocularis Administrator as you would any other event (i.e. map a camera to the event in the Servers / Events Tab and designate event distribution rules in the Distribution Groups Tab.) On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 13

Adjustable Column Width in Ocularis Recorder Manager Technical Notes for Ocularis 5.5 If a camera name or label of any entity in the Ocularis Recorder Manager is longer than twenty-one characters, the item was truncated and only visible using a horizontal scroll bar. Figure 13 Lengthy Text is not visible With v5.5, you can now manually adjust the width of the control bar to accommodate lengthy labels. Position the mouse on the edge between the main screen and the control bar until you see a double-arrow cursor. Click and drag left or right to adjust the width of the panels. On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 14

Figure 14 Adjust the width of the control bar The width of the panes will remain in place for all users on the local PC until manually changed again. 00001092018-1641-5.5.0.238 On-Net Surveillance Systems Inc. One Blue Hill Plaza, PO Box 1555, Pearl River NY 10965 T 845-732-7900 www.onssi.com page 15