Safety controller unit B1 /

Similar documents
Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

Multi-axial miniature joystick based on Hall Effect technology

AS-Interface Safety at Work

Float switch 298. Use. Variants. + Sturdy construction with very few moving parts. + Standard flange with different hole patterns

Phone: Fax: Web: -

Ergonomic joystick for parallel arrangement in the tightest installation spaces

CONFIGURABLE SAFETY RELAYS

Fingertip Joystick. Single-axis joystick for easy and ergonomic actuation. Use. Variants

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

Safety Temperature Limiter TT-STL 50

with extraction and return pipe

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Non-Contact Safety System CES-AZ

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

SafeC S to MSR127 Conversion

Safety. Detection. Control. MAGNUS RFID ENG - REV

Magnetic Style Safety Interlock Switches

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Phone: Fax: Web: -

Phone: Fax: Web:

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Analog micro push button

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Joystick base J2... Multi-axis, small version. Use. Options. + space-saving design

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

SMARTSCAN INFORMATION

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

ITEM ESM-BA301

ø13,4 58,5 31 Resistant to chemicals of the rubber material: International abbreviation EPDM (APTK) ter polymer Resilience at 20 C:

PSR DC/ESP4/2X1/1X2

MSR178DP. Description. Features. Specifications

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Multifunctional joystick handle 341/342G...

Safety module - PSR-SCP- 24DC/TS/S

Inductive sensor BI5-EM18-Y1X-H1141

RCMB20/RCMB Series

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Time Counters mini "h", DC Version

Datasheet SRB301ST 24V (V.2)

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

The safety control of the next generation

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Hiperface DSL Combined with Safety

E-STOP relays, safety gate monitors

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Inductive sensor BI1.5-EG08-Y1-H1341

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02

Datasheet - SRB 402EM-24V

Magnetically Coded Safety Switches CMS

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

PHOENIX CONTACT Features

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Datasheet - SRB 301LC/B-24V

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

AS-i Safety Analog Input Module, IP20

Micro push button 145MR/MG... with function and night illumination. Use. Types. + 2 selectable illumination colours

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Safety system - Vital Supervision of dynamic safety signals

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Inductive sensor BI1.5-EG08-Y1-H1341

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Contact expander modules

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

E-STOP relays, safety gate monitors

XPSMCMMX inputs 2 output pairs expansion module with screw term

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Series Single and double-pole rocker switches

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

HR1S-AC Safety Relay Modules

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Transcription:

Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring For sensors with 2-N.O. system Connection via codable pluggable 4-pin screwless terminals Optional double terminals or screw terminals available Thin design Up to 16 sensors can be connected via an external interface LED status display Automatic start or manual start via start push button Use Types 470111B1 and 470115B1 are used for evaluating the signals from safety sensors. All elobau sensors with a 2-N.O. system can be connected to the unit. This unit can be used in any machine safety application requiring SIL 2, PL d. Variants Types 470111B1 and 470115B1 differ in respect to their operating voltages of 24 V DC or 100 240 V AC. Available with optional double terminals or screw terminals. Safety controller unit 47011.B1 Version 1.1 Page 1 of 6

Mechanical assembly Installation dimensions Housing 120 x 100 x 22.5 mm (without terminals) 120 x 130 x 22.5 mm (with terminals) Installation On DIN rail TH35 acc. to DIN EN 60715 Key mechanical data Technology Control unit for 2-16 2-N.O. sensors* Material PA (polyamide), PC (polycarbonate) Weight 470111B1: approx. 150 g 470115B1: approx. 240 g Operating temperature range 0 C to 55 C Storage temperature -25 C to 85 C Housing protection class IP30 DIN EN 60529 Color Black * 2 sensors can be directly connected, and up to 16 with an additional interface Safety controller unit 47011.B1 Version 1.1 Page 2 of 6

Approvals and safety-relevant technical specifications Safety-relevant technical specifications Approvals SIL CL 2 (EN IEC 62061) PL d (EN ISO 13849-1) Category 3 (EN ISO 13849-1) PFH D 470111B1: 1.85e -8 1 / h (EN IEC 62061) PFH D 470115B1: 3.05e -8 1 / h (EN IEC 62061) Service life: 20 years TÜV / ETL (470111B1 only) Key electrical data 470111B1 470115B1 Operating voltage 24 V DC ±10% 100 240 V AC Current consumption Max. 120 ma Max. 40 ma Status indication 3x LED Monitoring External contactor / start push button Operating time 3 s Switching voltage Switching current Switching power Safety output 1 2 250 V AC / 30 V DC 3 A 750 VA / 90 W Wiring 100-240 V AC/24 V DC Input Logic Output K1 K2 6 5 8 7 10 9 12 11 14 2 1 13 - - - Sensor Sensor Safety 12 1-2 1 Sensor 21 Start-Push- push button Button/ / external contactor & Ready Ready Power UUB B 4 3 15 16 K2 K1 Circuit diagram in de-energized state. Sensors not actuated. Safety controller unit 47011.B1 Version 1.1 Page 3 of 6

Connection type Connection terminal 0.2-2.5 mm 2 Double terminal (optional) 0.2-1.5 mm 2 Screw terminal (optional) 0.2-2.5 mm 2 The pluggable screwless terminals can be coded via coding pins. If the device is then exchanged, the plug connections cannot be confused during installation. Optionally, double terminals or screw terminals are also available (see adjacent figure). Terminals 5-8: sensor 1 Terminals 9-12: sensor 2 Terminals 1 13: U B Terminals 2 14: external contactor / start push button Terminals 3 15: safety output 1 Terminals 4 16: safety output 2 The integrated LEDs signal if the operating voltage is switched on and which sensors are connected. After switching on the operating voltage, an automatic or monitored start is possible if all sensors are operating properly. Two sensors can be connected directly to the control unit. When using the following elobau interfaces, the monitoring can be extended to up to 16 sensors: 363V99 363.97 Safety controller unit 47011.B1 Version 1.1 Page 4 of 6

Fax: 49 (0) 7561 970-100 E-Mail: info@elobau.de Specifications of your safety controller unit Version 470111B1 (U B = 24 V DC) 470115B1 (U B = 100 240 V AC) Terminals Standard Double terminals* Screw terminals* * Additional costs accrue Safety controller unit 47011.B1 Version 1.1 Page 5 of 6

Fax: 49 (0) 7561 970-100 E-Mail: info@elobau.de Your product enquiry Quantity Batch size Name / first name Company Address Postal code / town Country E-Mail Notes, questions, other Safety controller unit 47011.B1 Version 1.1 Page 6 of 6