Magnetek Material Handling IMPULSE LINK 4.1 WDS

Similar documents
Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

Magnetek Material Handling IMPULSE LINK 4.1 WDS

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

IMPULSE Link 4.1 WDS. Instruction Manual. Wireless Diagnostic System. September 2017 Part Number: R10 Copyright 2017 Magnetek

Magnetek Material Handling IMPULSE LINK 4.1 WDS

IMPULSE LINK 4.1 WDS. Instruction Manual. WDS Configurator. April 2018 Part Number: R4 Copyright 2018 Magnetek

Magnetek Material Handling IMPULSE LINK 4.1 WDS

DriveWizard Plus Instruction Manual

3700 SERIES USER MANUAL

Regenerative Power Module And Common Bus RPM Panels Instruction Manual

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Installation. Installation 1

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00

E600 VX01 Installation guide

RC-SV Configuration Guide Revision 3

USB Serial Converter

BESTCOMSPlus Software

Software Installation Guide

EMIT SIM Software Installation and User Manual

Engineering Tool for PC SDWP001 Operating Manual

RC-SV Configuration Guide (Rev 4)

Mega 100WR ADSL 2+ Router - Easy Start

DPoE Element Manager. Release Notes

QUICK START. DevCom2000 User Manual

Software Package Installation Instructions

Rev T 237

Quick Start Installation Guide

EXPRESS. Users Guide. Version 3.5

MusicTel-Net/Net+ Installation and Operation Manual

SEIKA. Trans Braille 40 Braille Display. User s Manual Version 3.36

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Rapier Series Switch Quick Install Guide

USB485 USB to RS485 Converter Card

ZCRMZNICE01ZEMG Crimzon In-Circuit Emulator

Getting Started Guide

Network Guide NPD EN

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Two Door Controller GEN-045

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

READ ME FIRST Windows 98/ME/2000

EP/2 Installation Instructions

H-UC232S USB Serial Converter

ATL20 ATL30 Automatic transfer switch controller

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Application Note (Revision NEW) Original Instructions EGCP-3 LS Using an EGCP-3 in a Single-Phase Zig Zag Generator Application

Network Controller. Installation/Troubleshooting Instructions NK220 COM1131C

MU110-6U. Analog output module 6 channel. User guide

User Manual Australia

See Clean. Installation and Set Up Guide V with Confidence. 3M Clean-Trace Data Trending Software. 3M Food Safety

Configuration Guide for Microsoft Internet Connection Sharing

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

SEIKA. Trans Braille 40 Braille Display. User s Manual

USB Server User Manual

Canlan INSTALLATION MANUAL

WebPakCS Software Version 1.0

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

PL-85PE 85Mbps High Speed HomePlug Ethernet Adapter

BCM2 Series Branch Circuit Monitors Quick Setup Guide

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE

FieldServer X-25 Start-Up Guide

CS3000 MMI SW-Version 6.1 Control and Configuration Software for FlexPak3000 V , GV3000 V and Liqui-Flo. Instruction Manual

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

5504 Thermocouple Analog Input Module

Networking the printer

Graphical User Interface V1.0.3

RTS ISDN 2002 System. Operator Manual Software Description

WVL2 Wireless Vehicle Link 2 Installation and Setup Manual

File Transfer Tool Guide Version 1.0. Revision History. Revision Date Page(s) Changed Description of Change 4/2009 All pages First edition released.

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

SolarVu Installation Guide for Sungrow SG60KU-M Inverter

8380 RPC Return Path Combiner. User s Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

P3-SCM. General Specifications

Quick Setup & Getting Started

USER MANUAL. > analyze. reduce. recover

Manual Version: V1.00. Video Decoder Quick Guide

OilCop Component Wiring Installation Manual

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Pre-Installation Information--S8700 IP Connect

PL200M. 200Mbps powerline adapter. User Manual

User's Manual. USB DOCK - Einstein. Omnidirectional Control Technology Inc.

ACTpro Single Door IP Controller. Operating & Installation Instructions

May 2016 Version 1.2.7

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CommLink IV Technical Guide

Software Installation Guide

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

PROGRAMMING INSTRUCTIONS

ED40. Development Kit. Quick Start Guide

Vision 1612, 1624, 2424 and 2448 Installation Guide

Quick Installation Guide

User s Guide A

SEIKA. Braille Display. User s Manual V3 Pro Version 1.0

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Transcription:

Magnetek Material Handling IMPULSE LINK 4.1 WDS Wireless Diagnostic System Instruction Manual May, 2008 Manual Part Number: 140-10330 Copyright 2008 Magnetek Material Handling

2008 MAGNETEK MATERIAL HANDLING All rights reserved. This notice applies to all copyrighted materials included with this product, including, but not limited to, this manual and software embodied within the product. This manual is intended for the sole use of the persons to whom it is provided, and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by any means, whatsoever, without the expressed written permission of MAGNETEK. IMPULSE LINK 4.1 Software is copyrighted by Magnetek. All rights reserved. Page 1 of 42

Table of Contents Chapter 1 - Introduction...4 Overview... 4 System Requirements... 6 Chapter 2 - Installation...7 Software Installation... 7 Installing your Hardware Key... 8 Importing your Drive Profiles... 9 Creating Communication Profiles using the Wizard... 10 Hardware Installation... 11 Wiring the Base Unit... 11 Wiring the Remote Unit... 12 Chapter 3 - Navigation...15 Chapter 4 - Parameter Maintenance...19 Read From VFD... 19 Write to VFD... 19 Parameter File Display... 20 Modifying Parameters... 20 Parameter File Comparison... 22 Custom Defaults... 23 Security / Password Protection... 24 Chapter 5 - Monitor / DataLogger Function...25 Monitor... 25 DataLogger... 25 Fault Reset... 29 Chapter 6 - Additional Menu Features...31 Print Preview... 31 Parameter File Conversion... 32 Viewing Parameters... 33 Copying to the Clipboard... 33 Chapter 7 - Troubleshooting...34 Drive Faults References-... 34 Communication Error References... 35 Communication Profile Test... 36 Show Error Log... 36 Chapter 8 - Appendices...37 Appendix A: Serial Wiring for IMPULSE LINK WDS Base Unit... 37 Appendix B: Serial Wiring for IMPULSE LINK WDS Remote Unit... 38 Appendix C: Serial Wiring for IMPULSE G+/VG+ Series 2... 40 Appendix D: Quick Reference... 41 Page 2 of 42

Warning and Caution DISCLAIMER OF WARRANTY Magnetek s Electromotive Systems, hereafter referred to as Company, assumes no responsibility for improper programming of a drive that resulted from use of this software. This software should only be used by a trained technician who has read and understands the contents of this manual. Normal use of this software may result in the drive parameters becoming modified. Improper programming of a drive can lead to unexpected, undesirable, or unsafe operation or performance of the drive. This may result in damage to equipment or personal injury. Company shall not be liable for economic loss, property damage, or other consequential damages or physical injury sustained by the purchaser or by any third party as a result of the use of this software. Company neither assumes nor authorizes any other person to assume for Company any other liability in connection with the sale or use of this software. 1. Read this user manual in its entirety before installing IMPULSE LINK 4.1Wireless Diagnostic System(WDS)or operating the IMPULSE G+/VG+ Series 2, IMPULSE G+/VG+ Series 3, IMPULSE P3 Series 2, and/or Omni Pulse DDC Variable Frequency Drives (VFD). 2. DO NOT connect or disconnect wiring, or perform signal checks while the electrical power is turned ON. 3. Improper programming of a drive through the use of this software can lead to unexpected, undesirable, or unsafe operation or performance of the drive. Failure to observe these and other precautions indicated in this manual will expose the user to high voltages, resulting in serious injury or death. Damage to equipment may also occur. NOTICE No patent liability is assumed with respect to the use of the information contained herein. Moreover, Magnetek is constantly improving its high quality product; therefore, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this document. Nevertheless, Magnetek assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. Page 3 of 42

Chapter 1 - Introduction Overview IMPULSE LINK 4.1 Wireless Diagnostic System (WDS) is a user friendly, Windows based, interactive drive communication software and wireless hardware package. It is designed for communication from your PC over your company-wide network to the following Magnetek s drives: IMPULSE G+/VG+ Series 2 IMPULSE G+/VG+ Series 3 IMPULSE P3 Series 2 Omni Pulse DDC IMPULSE LINK 4.1 WDS consists of: 1. A remote unit consisting of a wireless modem, which is wired to your IMPULSE Drives and communicates wirelessly to the base unit. 2. A base unit consisting of a wireless modem connected to a PC using company-wide network. 3. IMPULSE LINK 4.1 WDS Software that allows access to all of the cranes in your facility from one location. A hardware key must be present in the computer s USB port to enable the software to access the drives. The Wireless Base Unit Model number: WDS-EBASE Description: NEMA 4 junction box (12 x 10 ) consists of a 120-volt standard power outlet, Ethernet wireless modem, externally mounted antenna to the junction box, Ethernet receptacle built-in to the junction box, and terminal block. Along with the NEMA 4 junction box, is a 6 crossover cable with Ethernet receptacle. The Wireless Remote Unit Model number: WDS-SREMOTE Description: NEMA 4 junction box (12 x 10 ) consists of a 120-volt standard power outlet, wireless modem, externally mounted antenna to the junction box, and terminal block. Along with the NEMA 4 junction box, the remote unit comes with 50 of twisted shielded cable to connect the drives to the modem. Software and Hardware Key Model number: WDS-SWARE Description: CD containing the IMPULSE LINK 4.1 WDS software, customer s drive profiles, and the hardware key. Remote Antenna Kit Model number: WDS-ANTENNAKIT Description: Hardware and accessories to remotely mount the WDS antenna (up to 10 feet from WDS Wireless Remote Unit). Page 4 of 42

SPECIFICATIONS Wireless Base Unit Enclosure: NEMA 4 Dimension (H x W x D): 12 x 10 x 5 inches (30.5 x 25.4 x 12.7 cm) Temperature: 32 104 F (0 to 40 C) Humidity: 0-95% Non-condensing Voltage: 120 VAC single phase, 0.8 Amps Wattage: 1 Watt Communication: Ethernet TCP/IP 10/100 Base-T Frequency: 900 MHz, Frequency Hopping, Spread spectrum Wireless Remote Unit Environment: NEMA 4 Dimension (H x W x D): 12 x 10 x 5 inches (30.5 x 25.4 x 12.7 cm) Temperature: 32 104 F (0 to 40 C) Humidity: 0-95% Non-condensing Voltage: 120 VAC single phase, 0.8 Amps Wattage: 1 Watt Communication: RS485 4-wire, 120 Ω Nominal Characteristic Impedance (Belden 9842) Frequency: 900 MHz, Frequency Hopping, Spread spectrum Range: 300 feet (91.4 meters) line-of-sight Page 5 of 42

System Requirements Supported Drives IMPULSE LINK 4.1 WDS supports the following Magnetek drives: IMPULSE P3 Series 2 IMPULSE G+/VG+ Series 2 IMPULSE G+/VG+ Series 3 OmniPulse DDC Note: Although the IMPULSE Series 2 drives are supported, a CMG5M communication board (part #140-10261) needs to be installed on each G+ or VG+ Series 2 drive. PC Requirements 1. Pentium class or equivalent 500MHz processor or better 2. 256 MB RAM or better 3. Minimum of 100 MB free hard-disk space available 4. Windows 98 SE, 2000, XP or Vista operating system. 5. Available USB or RS232 port. Network Requirements If specified, customer-supplied IP addresses can be configured into each base unit during factory setup. A tool, the WDS Configurator, is also included on the CD to assist in scanning and configuring the Impulse Link 4.1 WDS Modems. Although multiple users (computers) may have access to the drives on an Ethernet network, only one person can be accessing a particular bay at a time using the WDS Wibu key. Note: The maximum Ethernet cable length between devices is 328 feet (100 meters). The Ethernet connector type is RJ-45. Page 6 of 42

Chapter 2 - Installation Software Installation The IMPULSE LINK 4.1 WDS CD contains: the IMPULSE LINK 4.1 WDS Software and the communication profiles for the IMPULSE Drives used in your specific application. To run the IMPULSE LINK 4.1 WDS Setup, put the IMPULSE LINK 4.1 WDS CD into your CD drive. (Run setup.exe from the CD if it does not start automatically) Select the default choices during installation. Page 7 of 42

Installing your Hardware Key Insert your WDS Wibu hardware key into any USB port on your Windows will detect the hardware and begin installing the necessary computer. drivers. Select Next, leaving the (Recommended) choice selected. Wait while the hardware is installed. Windows will find the correct driver and install it. Click Finish to close the Completing the Found New Hardware Wizard dialog. Note: If you try to run IMPULSE Link 4.1 WDS and the hardware key is not inserted into a USB port on the computer, you will receive the following error message. Also, if you are running IMPULSE Link 4.1 WDS and remove the hardware key, the same message will appear until the key is re-inserted into the USB port. Free Updates, Patches Additional features and bug fixes may be available from time to time. These may be downloaded from the Magnetek Material Handling website at www.magnetekmh.com/downloads.htm. Software Removal To remove the IMPULSE LINK 4.1 WDS Drive Interface Software, open the Control Panel s Add/Remove Programs dialog box, double-click the IMPULSE LINK 4.1 WDS entry and choose Remove All from the IMPULSE LINK 4.1 WDS Setup dialog box. Page 8 of 42

Importing your Drive Profiles When you receive IMPULSE LINK 4.1 WDS, your profiles have been pre-configured for you and reside on the installation CD. When IMPULSE LINK 4.1 WDS is installed, the profiles will be imported automatically for you. Run IMPULSE LINK 4.1 WDS by double-clicking the L icon found on your desktop. A splash screen will appear for a few seconds while the subsystem loads. To import the profiles manually: 1. Select Communication from the Settings Menu. 2. Right-Click on the Communication Profiles Folder and select Import From File 3. Browse to your CD-ROM drive, select the files (*.CPX) and choose Open. 4. There will be a profile for each drive (Crane 1 Hoist, Crane 1 Bridge, etc.) 5. After the profiles are imported, select OK to save your communication profiles. Page 9 of 42

Creating Communication Profiles using the Wizard If you need to create a communication profile, there is a wizard to assist you. In the Settings Menu, click Communication, and then Right-click on the folder Communications Profile and choose Add Crane Profile. Enter the name of your crane for the folder. Right-click on this new folder and choose Add Profile. You will then see the following screen appear: Highlight the IMPULSE DRIVE, WM-E for the standard Wireless Ethernet Modem, and then click Select. The wizard will then take you through the following four steps to set up a new communication profile. Step 1: Name, Description, Crane and Motion Step 2: IP Address Step 3: Slave Address (01H to 1FH) and Parity (0:None) Step 4: Finish Page 10 of 42

Hardware Installation Mounting Be sure that the base and remote units are mounted in a location protected against the following conditions: Extreme cold or heat. Use within the ambient temperature range of: o Base Unit 32 to 104 F (0 to 40 C) o Remote Unit 32 to 104 F (0 to 40 C) Direct sunlight Direct rain, moisture High humidity o 0 to 95% Non-condensing Oil sprays, splashes Salt spray Corrosive gases The base and remote units should be mounted on a flat, non-flammable vertical surface using four mounting screws. Line of sight should be maintained from both the remote unit s and base unit s antennas to avoid communication dropouts. Wiring the Base Unit The Base Unit contains an Ethernet wireless modem. The Base Unit has an Ethernet receptacle at the bottom of the enclosure. A 6 cross-over cable with Ethernet connector is provided with the Base Unit. This 6 crossover cable can simply be plugged into the Ethernet port on a computer and then the opposite end can be plugged into the Base Unit s Ethernet receptacle. The Ethernet field connector kit (shown below) provides strain relief and can be cut-off from the 6 cross-over cable and connected to an alternative cable of desired length when connecting to an Ethernet switch or hub. At the bottom, right of the Base Unit enclosure is a cable grip for running the 115V control power wiring. The Ethernet receptacle is built in to the bottom left of the enclosure. Ethernet and control power wiring should never be run together. The typical wiring diagram for the Base Unit can be found in Appendix A. Page 11 of 42

Wiring the Remote Unit The Remote Unit contains two cable grips on the bottom of the enclosure. It is important that control and serial wiring are run separately. The Remote Unit comes with 50 feet of twisted shielded cable (Belden 9842) for wiring to your drives. IMPULSE G+/VG+ Series 2 drive: The IMPULSE G+ and VG+ Series 2 require a CMG5M serial option board. Connect multiple IMPULSE G+/VG+ Series 2 drives, using terminals 1 4 on the CMG5M board as shown in Appendix B. OmniPulse DDC drive: The OmniPulse DDC supports the 2-wire RS485 interface only. Wiring to the Drives When wiring the IMPULSE P3 Series 2, IMPULSE G+/VG+ Series 3 or OmniPulse DDC drives, the serial communication terminals are located on the control interface board. 1. Locate the correct terminals. 2. Use the twisted shielded wire provided with your Remote Unit for connecting as indicated in the table below. Wireless Remote Unit Terminal Block IMPULSE G+/VG+ Series 2 CMG5M Board Terminals IMPULSE G+/VG+ Series 3 and IMPULSE P3 Series2 Control Terminals OmniPulse DDC Description 8 or R+ 1 R+ T1-9 RS485B (T/R+) RS-485 signal 2 or R- 2 R- T1-8 RS485A (T/R-) RS-485 signal 7 or S+ 3 S+ N.C. RS-485 signal 3 or S- 4 S- N.C. RS-485 signal Shield TC2 TB4 Chassis Ground Shield connection 3. Set the terminating resistor. Note: Reference the drawings included in the WDS Remote unit or the wiring diagrams in the Appendix of this document for more information. Page 12 of 42

Terminating Resistor There is a dipswitch that is used to connect a terminating resistor (120 Ohms) to the serial communications for proper network balancing. (See next page for location). This terminating resistor needs to be ON at the beginning and end of the line for the RS485 communications. The Impulse Link Remote Unit has the terminating resistor enabled from the factory. Use a daisy-chain wiring configuration for connecting multiple drives. The terminating resistor should be turned ON, for one-to-one connections or on the last drive, when multiple drives are wired in parallel. Below is an overview of the daisy-chain configuration. One-to-one connection Multiple drive connection Page 13 of 42

Locating the Terminating Resistor The following diagrams illustrate the location of the terminating resistor for each family of drives. IMPULSE G+/VG+ Series 2: Dipswitch SW1 is found on the left side of the CMG5M RS485 option card. (Notice the ON position is on the left side of the switch.) Note: A typical wiring diagram for the IMPULSE G+/VG+ Series 2 drives is shown in Appendix C. S1 IMPULSE G+/VG+ Series 3: Dipswitch S1 is located on the interface board, as shown to the right. (Notice the ON position of S1 is with the switch to the right side.) Terminals R+, R- S+, S- S2 IMPULSE P3 Series 2: Dipswitch SW2 is located above the control terminals, as shown to the right. (Notice the ON position SW2 is with the switch to the right side.) OMNI PULSE DDC: Terminal jumpers LK2, are located near the center of the control board. With the jumper on pins 1 and 2, the terminating resistor is connected. With the jumper on pins 2 and 3, the terminating resistor is not connected. Display Connector LK2 1 Pins 1 and 2 120 Ohm Connected Pins 2 and 3 120 Ohm Not Connected Page 14 of 42

Chapter 3 - Navigation The IMPULSE LINK 4.1 WDS Software is a Windows-based software with easy to use menus and drop-down functions. The user is able to access utilities for uploading/downloading parameters, comparing parameters, saving parameters to a file, accessing the DataLogger function and more from the easy to navigate toolbar. The main screen allows the user to access more commonly used features at click from the main screen. New Displays the controller properties dialog to create a new factory default parameter set, based on the drive type, software number, model, and kva. Open Opens or finds a file containing a parameter set for a specific drive type and software number. Profile Shows the selected profile. Save Saves the active file with its current file name and location. Print Prints the active parameter set. Select Print options, in the Print window/dialog box. Print Preview Shows how a file will look when you print it. Show Error Log shows the status of IMPULSE LINK 4.1 WDS. IMPULSE LINK Help Provides information on communication profile settings and troubleshooting, complete Index of VFD fault codes, and a Search function. Write to VFD - Saves all parameter values from memory to the VFD. Read from VFD - Loads all parameter values from the VFD to memory. Properties Displays the properties box to view the properties of the active file. Page 15 of 42

The following gives a brief summary each of the functions that can be accessed from the navigation toolbar. New Displays the controller properties dialog to create a new factory default parameter set, based on the drive type, software number, model, and kva. Open Opens or finds a file containing a parameter set for a specific drive type and software number. Save Saves the active file with its current file name and location. Save As Saves the active file with a different file name or location. Print Preview Shows how a file will look when you print it. Print Prints the active parameter set. Select Print options, in the Print window/dialog box. Properties Displays the properties box to view the properties of the active file. Exit Closes this program after prompting you to save any unsaved files. Communication Allows communication profiles to be added, removed, edited, copied, imported and exported. Preferences IMPULSE LINK 4.1 WDS settings for access level. Custom Defaults Contains screen for maintaining custom default parameter files. Page 16 of 42

Write Flash - Allows a binary file to be written to VFD flash memory. (FACTORY USE ONLY) Read from VFD - Loads all parameter values from the VFD to memory. Write to VFD - Saves all parameter values from memory to the VFD. Convert Allows for parameter files to be converted from one software/flash ID to another (must be within the same drive serie). Compare Parameters - Allows for comparison of sets of parameter files. Communication Test performs a communication test with the VFD. Monitor Displays a select number of monitor parameters (U-parameters), updated continuously. DataLogger Opens the DataLogger function (described in more detail in Chapter 5). Keypad Simulator Emulates the keypad and allows for navigating the keypad menu remotely (this is not available unless hardwired to the keypad port). Show Error Log shows the status of IMPULSE LINK 4.1 WDS. Page 17 of 42

Window - Allows for easy parameter window recall and organization. All open files are enumerated at the bottom of this menu for switching between files more easily. Users Manual Displays the User Manual. (Acrobat Reader must be installed) IMPULSE LINK Help Provides information on communication profile settings and troubleshooting, complete Index of VFD fault codes, and a Search function. Electromotive on the Web provides a link to the Magnetek Material Handling website. Check for Updates provides a link to the download software page of the website that offers updates. About - Displays the version number of this Electromotive Systems product, copyright and legal notices. Page 18 of 42

Chapter 4 - Parameter Maintenance IMPULSE LINK 4.1 WDS software provides flexibility in programming, uploading, downloading, and saving parameters. With full parameter descriptions and visual programming, modifying parameters from your computer has never been easier. Read From VFD This function allows you to load the parameter values from the drive s memory. This can be accomplished through the VFD drop down menu or the Read Icon (as shown below). Write to VFD This function saves all parameter values from memory to the VFD. This can be accomplished via the drop down on the VFD menu or using the Write Icon as shown here. Writing to the VFD may result in undesirable operation of your crane, causing danger, personal injury or death! To proceed with the write to VFD function you will need to accept that you acknowledge the warning message as shown here. Once you have checked the I Accept button, the Continue write to VFD button will be available. Page 19 of 42

Parameter File Display Parameter Value Text Color Modified Constant A parameter with blue text implies that its value is different than its default setting. - This list should match the modified constants list in the drive, with the exception of A1 parameters. Read-Only A grayed-out, highlighted parameter implies that it cannot be modified. - The Access Level of the current parameter set is lower than what is needed for this specific parameter (i.e. Changing this parameter from the drive keypad would not be allowed with the current access level.) Over Maximum A parameter with red text implies that its value is greater than its maximum. An invalid value in the PAR file could result in this error. Under Minimum A parameter with green text implies that its value is less than its minimum. An invalid value in the PAR file could result in this error. Modifying Parameters 1. Begin modifying a parameter by double-clicking on the row of the parameter. 2. A drop-down list or edit box will appear in the Setting column. 3. Press Enter to accept the change or Escape to cancel. Drop-down List Example. This is displayed for drive parameters with a finite list of options. Edit Box Example This is displayed for drive parameters with a numeric range. Notes: 1. If a change is made, ENTER is not pressed to accept it, and the user clicks on another row or column, the value will revert back to what it was before the change. 2. If a parameter is changed to an invalid value, under the minimum value or over the maximum value, an appropriate message will be displayed and the value being edited will revert back to what it was before the change. Page 20 of 42

Visual Programming An additional editing option targeted towards more complicated parameters or parameters with extended settings that require using a table to calculate the value. Parameters with a Visual Programming option display an icon. To Edit: 1. Left-click once on the Visual Programming icon 2. Click on the appropriate selections. 3. Choose OK to accept the change or Cancel to abort. Page 21 of 42

Parameter File Comparison The Parameter File Comparison function found in the Tools drop-down menu allows for comparison of two sets of parameter files. Use the Load button to select the file you want to view on the left and right side. Once the parameter files are loaded, you can use the Show drop-down to compare: - all parameters of each file, - only parameters with equal values. - or only parameters with different values, Parameters shown in Red are parameters with different values. Page 22 of 42

Custom Defaults This function allows for the comparison of your current drive parameters to a custom, alternate set of parameters. This allows for a quick analysis of incorrect or non-uniform parameter setting within a file, without having to compare multiple files. Setting Up Your Custom Defaults: Custom Defaults are organized into Groups and Files. Each Group contains files with a unique combination of drive type, flash ID and model. Maintenance screens are provided for adding and removing these files. Alternatively, the user may also copy the entire CustomDefaults sub-directory from computer to computer. When Impulse Link 4.1 first loads, it scans the CustomDefaults sub-directory for valid PAR files. Note: The default Impulse Link 4.1 WDS path is C:\Program Files\Electromotive Systems\Impulse Link 4.1\ Using Custom Defaults: Using Custom Defaults is not much different than viewing Modified Constants. If the selected PAR file matches the drive type, flash ID and model within one of the Groups, the Group will appear in the drop-down. When a Group is selected, an additional column is displayed and the parameter file is filtered by whether the value matches the custom default. (rather than the factory default) Page 23 of 42

Security / Password Protection The Preferences drop-down menu in IMPULSE LINK 4.1 WDS software allows you to set the access level, username and password. By logging out of the Advanced mode, you will be in the User mode. While in the User mode, the drives can only be monitored. Write to VFD and Reset functions are NOT available. Page 24 of 42

Chapter 5 - Monitor / DataLogger Function Monitor There is a Monitor function in the Tools drop down, which displays a select number of monitor parameters (U-parameters) that are continually updated. DataLogger The DataLogger function provides monitoring of multiple IMPULSE drives simultaneously while it also records run, fault and alarm events to file. Note: A displayed fault may be clicked on to bring up corresponding help content. A DataLogger file (DS3) contains a limited number of events. When the maximum has been reached, the oldest entry is replaced. For each event, there are corresponding voltages, currents and frequencies recorded at the time the event occurred. For faults and alarms, additional data that occurred just prior to the event is also logged. This is known as Trace data. Available Events: 1400 run events 200 alarm events 200 fault events. A DataLogger file may be e-mailed for additional troubleshooting assistance. Note: The DataLogger function does not support data logging of IMPULSE P3 Series 2 drives. Page 25 of 42

To Begin 1. Click the check box of the drive(s) you want to monitor 2. Click the play button. The left window will change to show a button for each of the drives you selected and the overall status of the drive after it initializes connection. Each button will display a different color base on the status of the drive profile. White background with black text normal operation of the drive. Yellow background with black text there is an alarm present on the drive. Red background with white text there is a fault present on the drive. Page 26 of 42

This button also contains a brief description of the status. The following table lists these brief text messages displayed along with a description for each. Brief Text Displayed Alarm Communication Error <error code> Connected! Connecting Disconnected Drive Not Supported Faulted Forward Initializing Reverse Stopped Zero Spd Description Drive has an Alarm IMPULSE LINK is having trouble communicating with the drive. An error code will be shown to further assist IMPULSE LINK has established connection to the drive IMPULSE LINK is preparing the communication with the drive Communication has been lost between IMPULSE LINK and the drive The drive selected is not supported by the DataLogger function Drive has a fault Drive is being issued Forward command to run. IMPULSE LINK is trying to establish communication with the drive Drive is being issued Reverse command to run. Drive is stopped Drive is at Zero Speed Clicking the button in the left window for the drive, the right window will show the profile of the drive selected at the top along with continually updated information. There are 4 main areas displayed. 1) Profile of the drive selected showing 2) Summary 3) Monitor, and 4) Status Summary Displays current status of drive including last fault or alarm Profile - Displays the drive profile and other information about the drive Monitor Displays selected monitor parameters (U-Parameters). Status Shows the status of input and output terminals along with a visual of the drive status. Page 27 of 42

In the summary window if a Fault or Alarm condition occurs, the DataLogger allows you to click on the Alarm or Fault, and displays troubleshooting information (as shown here). The Status window allows for the viewing of input and output terminal status. By using your mouse, you can roll over the LED to view the meaning. See the example below. Terminal 5 is ON Page 28 of 42

Fault Reset In the event of a fault condition, you will see the fault icon on either the DataLogger window or the Monitor window as indicated below. Fault Reset Icon Note: You can reset a fault in the Monitor window or DataLogger window, as long as the drive doesn t have a Run command and the fault condition no longer exists. Once you click on the fault reset icon (as shown above), a warning message will prompt you to accept that you acknowledge the warning. When resetting a drive remotely, you need to be sure that all personnel and/or operators are notified. Once you have checked the I accept box, the Continue Fault Reset button will be available. Page 29 of 42

Fault / Alarm / Run history Click on any one of the three icons (Fault/Alarm/Run) at the top of the DataLogger will change the view to show three new tabs. Each tab will allow you to view either Fault, Alarm, or Run history for the drive. In this window you can view the History for each tab. Clicking on the plus (+) sign will show additional information related to the fault or alarm. Page 30 of 42

Chapter 6 - Additional Menu Features Print Preview IMPULSE LINK 4.1 WDS provides a compact printing mode that displays all drive parameters in only 1-2 pages. It also prints a more detailed mode that lists descriptions as well as units for each parameter. Compact Parameter Print Preview Detailed Parameter Print Preview Print Printer Name Allows the user to select from any printer installed on his/her system. The user s default printer is initially selected. Print Mode - Allows the user to choose the printing style. o Compact mode (1-2 pages) provides parameter name and setting value. o Detailed mode provides parameters, descriptions, setting, o values and units as well as modified information. As shown prints all of the information as shown on the screen. OK Button Prints the active parameter set to the selected printer in the chosen format. Cancel Closes this dialog box without printing. Changes to Customer Name, Application and Job Number are not saved. Text placed in the Customer Name, Application and Job Number fields appear on the printout. NOTE: Only parameters that are viewable in the Parameters Window will be printed. Page 31 of 42

Parameter File Conversion Convert under the Tools menu allows for parameter files to be converted from one software/flash ID version to another (within the same drive series). Source Specifies the file to be converted. Flash ID Specifies the software type that the file will be converted to. Destination Filename Specifies the Destination filename. Convert - Converts the parameter file specified in Source to the format specified in the software version in the Flash ID. The converted file is saved to the filename and path specified in Destination Filename. Keypad Emulator The keypad emulator communicates with an IMPULSE drive exactly as the physical keypad does. This allows for remote keypad menu navigation. Note: This function is only available when IMPULSE LINK 4.1 WDS is connected via the drive s keypad 1CN connector (instead of the standard RS485 connection) primarily for training purposes. If you attempt to run the keypad simulator while connected via the standard RS485 connection a CF00 Comm Error will occur. Digital Operator Emulator NOTES: 1. To Activate, Select the correct drive profile from the dropdown and click the button. 2. The Keypad will automatically close if any communication function, such as Upload and Download, or a new offline parameter set is created from the Controller Properties window. 3. The RUN command has been disabled for safety reasons. 4. If the drive is put into Program Mode and not returned to Run Mode, the user will be unable to run the drive. Page 32 of 42

Viewing Parameters The View drop-down box allows filtering of parameters based on parameter group organization and the parameter value (modified from factory defaults or from custom defaults). Copying to the Clipboard Impulse Link 4.1 provides the ability to copy displayed parameter information to a preferred word processor or spreadsheet. To do this, select one or more rows and either press Ctrl-C or right-click to display the context menu, shown to the right. The copied information is available to be pasted in either HTML format or Ascii text. Tip: Change from full row selection mode to single cell selection mode by doing the following. 1. Click and hold the left mouse button over any row. 2. Drag the mouse down while the left-mouse button is still being held. An icon will replace your mouse pointer 3. While still holding the left mouse button, click the right mouse button. The icon will become skinnier and you will no longer be restricted to selecting the whole row. Repeat to return to full row mode. Page 33 of 42

Chapter 7 - Troubleshooting The IMPULSE LINK 4.1 WDS Help section provides the following: Reference to Drive faults and corrective actions. Reference to Impulse Link error codes and corrective actions. Communication profile settings overview. Drive Faults References- IMPULSE LINK 4.1 WDS offers built-in Help screens for the drive faults and/or alarms. The Help screens provide advanced diagnostics allowing you to troubleshoot your drive from your PC. When you click on the fault, the help screen provides the fault code, fault name/description, and the corrective action. Or you can simply go to the Help Icon and go to the Drive Fault References for a complete list of P3 Series 2, G+/VG+ Series 2 and 3 drive faults, as shown below: Page 34 of 42

Communication Error References The Help function provides an overview of the possible errors that could occur while running IMPULSE LINK 4.1 WDS, as shown here: By clicking on the type of error, you will be provided the fault code with description and correction action. Page 35 of 42

Communication Profile Test The Communication Profile Test Utility is a tool to assist in troubleshooting communication difficulties. It performs the following sequence: 1. Opens the communication port with the selected settings. If the port opens successfully, the port exists and Impulse Link has access to it. 2. Sends a loop-back test message to establish whether a valid device exists with the settings in the profile. If the loop-back fails, the device may not be powered, present or supported. 3. Identfies the drive model and version. If the discovered type is unknown, Impulse Link does not support it. Note: If any of the above steps fail, an error message is prompted to the user with an error code (i.e. CE100). For further troubleshooting reference the error code in the help section. Show Error Log This function also found in the Tools drop-down menu, brings up an additional window showing various status details of IMPULSE LINK 4.1 WDS. Page 36 of 42

Chapter 8 - Appendices Appendix A: Serial Wiring for IMPULSE LINK WDS Base Unit Page 37 of 42

Appendix B: Serial Wiring for IMPULSE LINK WDS Remote Unit (G+/VG+ Series 3, P3 Series 2, G+/VG+ Series 2) Page 38 of 42

Wiring for IMPULSE LINK WDS Remote Unit (OmniPulse DDC) Page 39 of 42

Appendix C: Serial Wiring for IMPULSE G+/VG+ Series 2 R+ R- S+ S- RS-485 Shielded Sheath Connection TC1 1 2 3 4 SW1 TC2 Ground Connection 2CN CMG5M BOARD 6CN TC1 1 2 2CN Shielded Sheath Connection 3 4 SW1 TC2 Ground Connection CMG5M BOARD 6CN Page 40 of 42

Appendix D: Quick Reference G+/VG+ Series 3 R+ R- S+ S- Shield: TB4 Parameter Modbus Address H5-01 Baud Rate H5-02 Parity Select H5-03 Typical Setting ( 01 ~ 1F ) 3: 9600 Baud 0: No Parity OmniPulse DDC RS485B (T/R+) Baud Rate G16 9600 X1: RS485A (T/R-) 1 2 3 4 5 6 7 8 9 10 RS232/RS485 Select Serial Format G17 G18 RS485 8N1 Shield: Chassis Ground Modbus Address G19 ( 1 ~ 247 ) 1 2 3 4 G+/VG+ Series 2 (SI-K2 option card) R+ R- S+ S- Shield: TC2 Slave Address H5-01 Baud Rate H5-02 Parity Select H5-03 ( 01 ~ 1F ) 3: 9600 0: No Parity P3 Series 2 R+ R- S+ S- Shield: Chassis Ground Slave Address Baud Rate Parity Select n253 n254 n255 ( 01 ~ 1F ) 2: 9600 2: No Parity Note: 2 = 9600 3 = 19200 Page 41 of 42