Johnson Controls York Acoustics

Similar documents
Position Title: H V A C T E C H N I C I A N. G.E.D. or High School Diploma required, an Associate s Degree is preferred.

CONTROLLING ROOFTOP UNIT (RTU) NOISE

Consultancy along with installation for Air Conditioning System and expertise in Clean Room Systems.

DUCTED SPLIT SYSTEMS With Scroll compressors

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Rooftop Unit System Solution. for noise, vibration, and seismic/wind effects

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

REP N BANK ST. ENVIRONMENTAL NOISE STUDY Page 1 of 14

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Impact of Sound on Computer Hard Disk Drives and Risk Mitigation Measures

YORK SOLUTION AIR HANDLING UNITS

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

The noise of cloud computing

200 kw, Tier 3, Chilled Water, 5250 ft 2

Magnitude magnetic bearing centrifugal chillers

WO P-NF-L-M-407c Spec Submittal

Magnitude magnetic bearing centrifugal chillers

Temperature/Humidity Agree vibration chambers

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions

DATA CENTER AIR HANDLING COOLING SOLUTIONS

ROOFTOP UNIT NOISE CONTROL SOLUTIONS

Samuel Tepp Engineering Seminar Topics

Cannon T4 Modular Data Center (MDC)

ECOBAY: Closed loop water cooled server cabinet for data centers

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Tier IV Standards as Specified in the TIA 942 Document

KINETICS Vibration Isolation Manual

Computational Fluid Dynamics at CERN

Temperature/Humidity, Vibration Chambers

NetShelter CX Technical Guide

Prediction of Chilled Water Plant Failures and System Optimization Using Multivariate Modeling Techniques

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

Measurement of Static Insertion Loss of Flexible Ducting

Acoustic Source Location in Vehicle Cabins and Free-field with Nearfield Acoustical Holography via Acoustic Arrays.

ACTIVE NOISE CONTROL APPLIED TO BUILDINGS COMPONENTS

NetShelter CX Performance Guide

TECHNICAL SPECIFICATION

Environmental Noise Study of. Findlay Creek Public School Findlay Creek Drive, Ottawa, Ontario. R1. Prepared for: N45 Architecture Inc.

Branch Circuit Power Systems Access Floor Modules AFm and AFm/M Series

Power and Cooling for Ultra-High Density Racks and Blade Servers

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

PRODUCT DATA. PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis. Uses and Features

Ultra Micro Cooling Device

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

CenterPoint Energy Retro-Commissioning Program Application

oom Pressurization Con

ORION Smart Vibration Monitoring Terminal. Always keep an eye on vibrations. 01dB.com

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012

Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection

FOR SALE 7325 ASPEN LANE

Towards Self-Conscious Buildings through connected products

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance.

FOR SALE 7325 ASPEN LANE

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

We have you walking on air

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

IMPACT DOT-MATRIX PRINTER

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

HVAC Energy Management System

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Electronics Cooling Using Conduction Convection Radiation from Heat Sinks to Heat Pipes - CFD Consulting Services

Buildings of the Future. Dave Hopping President, Siemens Building Technologies - Americas

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

INNOVATE DESIGN APPLY.

Facility Requirements LaserCube SYS-4x4-YLS

INNOVATE DESIGN APPLY.

Final Thesis Presentation

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building

Driving Proactive Facility Operations with Automated HVAC Diagnostics

84 kw, Tier 3, Direct Expansion, 937 ft 2

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

Room acoustic modelling of a reverberation chamber

ComEd Retro-Commissioning and Monitoring-Based Commissioning

User s Guide. Recair Smart Air Designer MagiCAD Plugin - Installation Instructions and User Guide

This document is downloaded from the Digital Open Access Repository of VTT. VTT P.O. box 1000 FI VTT Finland

Building Energy Management Training Systems

SISTINE CHAPEL STUDY & PROJECT. NAME Title Carrier HVAC Europe

The Shared Data Centre Project

5.2 MW, Pod-based build, Chilled Water, ft 2

Thermal Diffusivity Instruments DLF-2 with EM-1600

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

As a key supplier of EMC testing for the F-22 Program, D.L.S. Electronic Systems, Inc.

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Energy Performance Contracting

Dual Duct Controller - One Air Velocity

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

Engineering Services

Why Should We Care? Building Intelligent Solutions 2

RT4F-120V/20A-WAC RECTIFIER

Chloride CROSS Rack 16 A, 32 A and 63 A

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Pathfinder AWV air-cooled screw chillers

Transcription:

Johnson Controls York Acoustics If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the Home ribbon (next to the font choice box) If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the Home ribbon (next to the font choice box) R. Troy Taylor Sound and Vibration Engineer CAV Spring Conference 2017

Acoustics Team at Johnson Controls York About me BS Physics, Brigham Young University 2011 MS Acoustics, Penn State University 2014 2.5 years as an acoustics engineer at Johnson Controls About our Team Engineering services team led by Pat Marks Sound and Vibration team managed by Dale Unger Four full-time engineers Two part-time consulting engineers (retired JCI employees) Two full-time technicians Air handling unit acoustics team led by Curt Eichelberger Two full-time engineers 2

Johnson Controls creates intelligent buildings, efficient energy solutions, and integrated infrastructure that work seamlessly together to deliver on the promise of smart cities and communities. Power Solutions Buildings Batteries HVAC Equipment Distributed Energy Storage Security and Fire Safety 3

The acoustics and vibration team performs research, product development, testing and evaluation geared to creating and sustaining quiet and reliable chillers and air handling systems for our customers. Variable Geometry Diffuser Varies Width to Match Changing Flow Pin & Diffuser-Ring Motion 4

At our current York facility we have a variety of test facilities for acoustic testing of water-cooled chillers, air-cooled chillers and air handling units 5

Two hemi-anechoic chambers used for testing water cooled chillers Laboratory Specifications: Large Hemi-Anechoic room: Volume: 41,000 cu-ft. 3000 TR loading capability Door clearance: 18 wide x 16 high. Room floating on 41 ½ static deflection isolators. 1.7 million pound building weight. Room Qualification to 50 Hz. Small Hemi Anechoic Room: Volume: 18,000 cu-ft. 400 TR loading capability Mechanical Support Equipment Isolation. Special capability: Simultaneous testing of thermal and sound performance in a hemi-anechoic environment. Noise signature testing for US Navy chillers. 6

Water cooled chiller measurements done according to AHRI 575 using Mueller BBM data acquisition system AHRI 575 is a method of measuring machinery sound within an equipment space 7

There is also a hemi-anechoic room used for acoustic testing of aircooled chillers Laboratory Specifications: Hemi-Anechoic room: Volume: 38,000 cu-ft. 340,000 CFM Quiet Air Supply Support Equipment > 400 TR loading capability Mechanical Support Equipment Isolation Special capability: Simultaneous testing of thermal and sound performance in a hemi-anechoic environment Measurements done according to AHRI Standard 370 8

Statistical Energy Analysis models are used for noise predictions of products in development and for changes to existing products SPL Measured Predicted Frequency (Hz) Software: ESI VA One Internal compressor pulsation measurements used as inputs to the model 9

Air-handling unit testing Laboratory Specifications: Reverberation room: Volume: 105,000 cu-ft. Apertures: 12 x 12 and 8 x 8 (for duct connections). Door clearance: 14 wide x 14 high (for casing radiated sound). Silencers sized to pass air through the Rev. Rm. (< 0.2 iwg pressure at 100,000 cfm). Analyzer with dual rotating microphone booms for sound measurement. Code Testers: 100,000 cfm code tester, rated at 9 iwg, turn-down to 10% of flow. 30,000 cfm code tester, rated at 9 iwg, turn-down to 10% flow. Special capability: Simultaneous testing of air and sound performance. Test fully assembled AHUs. Test packaged equipment (rooftops, floor-by-floors) Test Standard AHRI 260 10