NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Similar documents
NEUROLOGIC RESEARCH CORPORATION MODEL 1160 INITIAL DRAFT INDOOR TEMPERATURE NETWORK TRANSMITTER

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY

MODEL 2000T Initial Draft

FEATURES DESCRIPTION MODEL 110B. Power Supply

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

CTR21, CTR22, CTR23, and CTR24 Wall Modules

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

TOXALERT MODEL AIR 2000

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TALON Network Manager- 2 & 6 Express

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

LAUREL ELECTRONICS, INC.

DESCRIPTION WIRING AND INSTALLATION. LonWorks Utility Metering Display NOTE

LTEC Heat Pump DDC Controller

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

AZ420 MINIATURE GENERAL PURPOSE RELAY

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

Model 305e OEM CO 2 concentration sensor

SERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Mini Digital Multimeter

LX Series Free Programmable Controllers

Zone Pressure Touch Sensor - Standard Range

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

LAUREL ELECTRONICS, INC.

Mini Digital Multimeter

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

USB-PDISO8 Specifications

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

BA/BS4S Temperature Sensor Installation & Operating Instructions

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Time Counters mini "h", DC Version

S66 Series Electronic Fan Speed Control

AirTest Model CN9000 Series Sensor Controller

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Zone Pressure Touch (ZPT) Sensor - Standard Range

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Environdata FA ma Converter Guide

Product data sheet accessories control and regulation Accessories AIRWIN

Andover ContinuumTM Infinet II

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

RCM Room Command Module New Style

Andover ContinuumTM Infinet II

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

DS A 10/99 MN 500 I/A SERIES MICRONET MN 500 CONTROLLERS APPLICATION SPECIFICATION

User's Guide. Digital Multimeter. Model MN42

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

CDD Carbon Dioxide Transmitter

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

H7625A, H7635A Humidity/Temperature Sensors

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Actuator Commissioning Tool

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Installation Manual for D244X Series 24-volt Power Supplies

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BACnet. b3810 Series Local Controllers

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

Trident and Trident X2 Digital Process and Temperature Panel Meter

TPE 1464 Series Pressure Transducer

Analog Voltage Combination Module

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Tempco Instruction Manual

CDD4 Duct Carbon Dioxide Transmitter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Model R5010. TRMS Digital Multimeter. Instruction Manual

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

EP-ELVCTL Elevator Control (NION-16C48M)

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

Transcription:

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication standard using LonWorks Protocol using Standard Network variable types. Can be used for humidity control as well as temperature and humidity monitoring via optional Network Interface Module or two analog voltage outputs. 110 VAC, 220 VAC 50/60 Hz., and low voltage AC/DC versions are available. On-board 110/220 VAC 10 Amp relay output with arc suppression and LED status indication. Mode switch allows testing of output relay function. Jumpers allow the humidity setpoint to be changed manually. Minimum Cycle Time, Maximum On-Time and Deadband configuration parameters protects the equipment and prevent fast on/off cycling. Configuration parameters can be accessed and modified via network. DESCRIPTION The Model 2500 Network Humistat is a standalone de-humidifier controller. It contains a temperature sensor, humidity sensor, microprocessor, measurement electronics, and an optional network communication interface. The external de-humidifier is controlled via an on-board relay. The relay has a rating of 10 Amps at 110 or 220 VAC. The temperature and humidity sensors are in a porous filter, away from the electronics. This allows a more accurate measurement of air temperature and humidity for two reasons. One, it isolates the sensors from temperature generated by the electronics. Two, it provides excellent airflow around the sensors. The sensor and configuration information is communicated to other devices via the LonWorks communication protocol. This allows multiple sensors to be used over a simple four-wire bus installation. The unit is available in 110 VAC, 220 VAC, or low voltage AC/DC versions. WIRING AND INSTALLATION The Model 2500 can be panel or wall mounted via four screws. For best results and accuracy the Model 2500 enclosure should be mounted with the filter horizontal to the ground. Correct Mounting Position NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0

Installing the Network Interface Module The Network Interface Module is an optional feature of the Model 2500. It allows temperature and humidity to be digitally monitored as well as allow changes to the factory default configuration parameters is required. Network Interface Board Network Wiring Service Button The Network Interface Module can actually be plugged into a unit to configure it and then removed before the unit is put into service. The Model 2500 will retain the configuration parameters even after the Network Interface Module is removed. The interface also includes the Service switch used to install onto a LonWorks network. Make sure power is removed from the Model 2500 before plugging the Network Interface Module. Connecting Power Input power for the Model 2500 comes into a two position terminal block labeled TB1. The terminals are not polarity sensitive. WARNING Externally fuse the AC input using a ½ Amp rated fuse. Please wire the AC input before applying electrical power. Failure to do so may result in electrical shock. Dry Contact Connections AC Power Connections NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 2

Connecting The Relay Output MODEL 2500 The dry contact or relay output is provided on the terminal block labeled TB2. The terminals are not polarity sensitive. However, any device switched via the Model 2500 s relay should be externally fused at 10 Amps or less. WARNING Externally fuse any device switched by the on-board relay using 10 Amps rated fuse. Please wire the relay output before applying electrical power. Failure to do so may result in electrical shock. Operating Modes and Testing Output Relay The Model 2500 has two operating modes: Auto and Test. The Mode LED is green and is on when in Test Mode. The default mode on power-up is Auto. When in Auto Mode, the Model 2500 executes its control function. To toggle between Test and Auto Mode, hold the Mode Switch for 10 seconds and then release. While in Test Mode, you can test the function of the output relay as well as attached equipment by pressing and releasing the Mode Switch. To go back into Auto Mode, hold the Mode Switch for 10 seconds and release. The Humidity Setpoint The Humidity Setpoint can be set either by three on-board jumpers between 20 and 80% in 10% increments or via the network. With the network option, the Humidity Setpoint can be changed between 0 and 100% with a resolution of 0.05%. Jumper Block JP 1 J1 Voltage Outputs Mode Switch Connector for Network Interface Board J2 Jumpers 1-3 on jumper block JP1 take priority over the network Humidity Setpoint, ncirhsetpoint. The jumpers are used as follows: NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 3

JP1-1 JP1-2 JP1-3 Humidity Setpoint OFF OFF OFF Network Humidity Setpoint ncirhsetpoint is used. Factory default is 40% ON OFF OFF 20% OFF ON OFF 30% ON ON OFF 40% OFF OFF ON 50% ON OFF ON 60% OFF ON ON 70% ON ON ON 80% If the network interface is installed, the actual setpoint used can also be read via the nvorhsetpoint variable. If nvorhsetpoint does not equal the ncirhsetpoint, it implies that the jumpers are being used. Controlling Humidity The Model 2500 de-humidification algorithm controls humidity by turning on an external de-humidifier when the humidity rises above the Humidity Setpoint. The de-humidifier is turned on for a minimum period of ncimincycletime. The de-humidifier is turned off for a minimum period of ncimincyletime when the humidity drops below the Humidity Setpoint minus the ncirhdeadband. ncirhdeadband defaults to 3% and ncimincycletime defaults to 150 seconds. An additional parameter, ncimaxontime, ensures that the de-humidifier is never on for more than a specified period of time before it is turned off for a period of ncimincycletime. By default, ncimaxontime is set to 0, which disables the ncimaxontime function. Voltage Outputs The Model 2500 has two analog voltage outputs available at connector labeled J1. This allows remote monitoring of temperature and humidity without using the Network Interface Module. To protect the electronics, the outputs have high output impedance. They are over voltage and short circuit protected. For maximum accuracy, use measuring devices with input impedance of 500K Ohms or above. This is common on most digital multi-meters and high quality analog input modules. The connector J1 has four positions labeled, G, 1, G, 2. The terminals labeled G are ground references. The terminals labeled 1 and 2 output a voltage as follows: Output ( J1 ) Function Range Comments 1 Humidity 0 4 volts represents 0 100% humidity 2 Temperature 0 4 volts represents -50 to 150 C Multiply voltage output by 25 to get the percent humidity. Example, 2 volts equals 50% humidity. A value of 5 volts indicates an error condition. Multiply meter reading by 50 and subtract 50 to get the temperature in C. Multiply by 90 and subtract 58 to get temperature in F. Example, 1.5 volts is 25C or 77 F. A value of 5 volts indicates an error condition. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 4

NETWORK INTERFACE Configuration Network Variables Name Type Default Description ncitempoffset SNVT_temp_p 0 Offset for calibrating nvotemp if needed ncirhoffset SNVT_lev_percent 0 Offset for calibrating nvorh if needed. ncitempdelta SNVT_temp_p 0.3C Change of nvotemp before a new value is sent ncirhdelta SNVT_lev_percent 5% Change of nvorh before a new value is sent nciminsendt SNVT_time_sec 5 seconds Minimum amount of time between updates to nvorh, nvotemp, and nvorhsetpoint ncimaxsendt SNVT_time_sec 5 seconds Maximum amount of time between updates to nvorh, nvotemp, and nvorhsetpoint ncirhsetpoint SNVT_lev_percent 40% Humidity setpoint. This value is used only if all jumpers on JP1 are off. ncimincycletime SNVT_time_sec 150 seconds Minimum amount of time the output relay will be turned off and on. ncimaxontime SNVT_time_sec 0 seconds Maximum amount of time the output relay will be energized. Set to 0 to disable maximum on-time function. ncirhdeadband SNVT_lev_percent 3% The output relay is turned off when the humidity drops below the Humidity Setpoint minus ncirhdeadband. Output Network Variables Name Type Description nvotemp SNVT_temp_p Measured temperature nvorh SNVT_lev_percent Measured humidity nvorhsetpoint SNVT_lev_percent Actual humidity setpoint used. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 5

GENERAL SPECIFICATIONS Temperature Sensing Element Accuracy Temperature Range Resolution Solid State +/- 0.5 C typical 15 C to 55 C : +/- 1.0 C typical entire operating range -20 to 70 C 0.1 C Relative Humidity Sensing Element Solid State Capacitive Accuracy / Resolution +/- 2% RH, 5-95% RH, 0-50C - +/-3% RH 0 to 70C - Resolution is 0.04% Maintenance No routine maintenance required Sensor Stability +/-1% RH typical at 50% RH in 5 years Voltage Outputs RH Voltage Output 0 to 4 volts represents 0 100%. 5 volts indicates fault condition. Resolution is 0.5%, accuracy is 1% Temperature Voltage 0 to 4 volts represents 50 to 150C. 5 volts indicates fault condition. Resolution is 1 C, accuracy is 2 C. Output Temperature / RH Voltage 1500 Ohms. Should be read with a device that has a minimum input impedance of 500,000 Ohms. output impedance Electronics Operating Environment CPU Input Power (Low Voltage AC/DC version) Input Power (110 VAC version) Input Power (220 VAC version) Power Transformer (110/220 VAC versions) Input Power Protection Dry Contact / Relay Output Network Transceiver Type Terminal Blocks -20 to 70C, 0-95% RH non-condensing 3120 Neuron 15 to 32 VDC or 12 to 26 VAC at 50 ma typical 110 VAC +/- 15% 50/60 Hz. at 1 VA. Must be externally fused using 0.5 Amp fuse. 220 VAC +/- 15% 50/60 Hz. at 1 VA. Must be externally fused using 0.5 Amp fuse. UL / VDE rated Sealed, 4000 VAC isolation Low voltage ac/dc input power is fused and transient voltage protected. (Fuses do not need to be replaced). 110 / 220 VAC versions must be fused using an external 0.5 Amp fuse. 110/220 VAC at 10 Amp maximum or 30 VDC @ 10Amp. 2500 VAC isolation. Service life 20 million operations minimum. Contact resistance is 30 milliohm. UL and CSA rated for 250 VAC, 10 A, general purpose at 100,000 cycles Relay contacts have arc suppression. Output must be fused using an external 10 Amp fuse or less. Echelon FTT-10A transceiver at 78 kbps. DC blocking capacitor for LPT10 network. Screw-less terminal blocks. Accepts up to 16 GA wire. Input power is polarity insensitive. Network wiring is polarity insensitive. Relay output is polarity insensitive. Dimension and Materials Overall Dimensions 2.8 W x 6.8 L x 2.25 H Mounting Holes 4 holes on a 3.25 square grid Housing Material ABS Plastic NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 6

ORDERING INFORMATION 2500 Model 2500 Network Humistat Code Network Transceiver Option -0 TP/FTT-10A Network Interface Module -1 No Network Interface Code Input Power Option -0 Low Voltage AC/DC Model -1 110 VAC 50/60 Hz. -2 220 VAC 50/60 Hz. 2500-0 -1 Model 2500 Network Humistat with FTT-10 Network Interface Module and 110 VAC power input option. Echelon, LON, LonWorks, Neuron, 3120, 3150, LONMARK are trademarks of Echelon Corporation. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2002 Rev 0 Page 7