IECEx Certificate of Conformity

Similar documents
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Refer to attachment for more details. Andreas Meyer

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Page 1 of 5. Increased Safety, Encapsulation and Dust

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

I Ex-Installation switch I

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

Operating Instructions

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

IECEx Certificate of Conformity

IECEx Certificate of Conformity

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Zener Barriers Bulletin 937Z

IECEx Ce ificate of Conformi

Page 1/4. CER1iATEX\EQUIP\CATI-2\P, Issue 1, Dated September 1998

Ex Certificate of Conformity

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

How to calculate an Intrinsically Safe loop approval.

IECEx Certificate of Conformity

Isolating repeater IRU 420

MTL8000-2/x Series Modular I/O

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Safety instructions VEGATOR 121, 122

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Certificate of Conformity

UIM Series Flowmeter Field Wiring Guide

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

IECEx Certificate of Conform ity

Safety Instructions Cerabar M PMC51, PMP51, PMP55

APPLICATION GUIDE. Interface Modules IM Series.

Interface and Supply module. IPC 3x0i / PSC 3x0i

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

ECE Cert.fic te of Con ormity

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

M E M O R A N D U M I.S.

IECEx Certificate of Conformity

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

IECEx Certificate of Conformity Annexe

Micro Motion, Inc. Page 1 of 6

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

Intrinsically Safe Barriers

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

MTL SD range Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling.

Trendmaster* Galvanic Isolator

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

F300 Megablock Series Fieldbus Device Couplers

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

BA414DF Fieldbus indicator Single variable

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Hazardous Area Protection

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Safety Instructions Cerabar S PMP71, PMP75

Safety instructions Overvoltage protection B81-35

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

General Specifications

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Limit switches Instrument sensors

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

IECEx OPERATIONAL DOCUMENT

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Certificate of Conformity Ex EQUIPMENT

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

General Specifications

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Status: Current Page 1 of 5 issue No.:1 Certificate history: Issue No.1 (2016-11 16) Issue No. 0 (2015-10 19) Applicant: Eaton Electric Limited Great Marlings Butterfield Luton Bedfordshire LU28DL Equipment: Optional accessory: MTL5541/ MTL5544 Repeater Power Supply, 4/20mA for 2 or 3-Wire Transmitters Type of Protection: Type of Protection 'n' Marking: Ex na IIC T4 Gc (-20 C:S Ta:S +60 C) Approved for issue on behalf of the IECEx Certification Body: Position: R.S. Sinclair Technical Manager Signature: (for printed version) Date: ~~~ t ~ f\f QJ~Ea- ~ \ G 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SGS Baseefa Limited Rockhead Business Park Staden Lane Buxton, Derbyshire, SK17 9RZ

Manufacturer: Eaton Electric Limited Great Marlings Butterfield Luton Bedfordshire LU28DL Issue No.: 1 Page 2 of 5 Additional Manufacturing location(s): MTL Instruments PVT Limited No 3 Old Mahabalipuram Road Sholinganallur Chennai 600119 India This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-15 : 2010 Edition: 4 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 15: Equipment protection by type of protection "n" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) ofthe equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/BAS/ExTR15.0267/00 GB/BAS/ExTR16.0242/00 Quality Assessment Report: GB/BAS/QAR06.0022/06 GB/BAS/QAR07.0017/06

Issue No.: 1 Page 3 of 5 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The MTL5544 Repeater Power SUpply, 4/20mA for 2 or 3-Wire Transmitters is designed to provide a floating d.c. supply for energising two conventional or 'Smart' 2 or 3-Wire 4/20mA Transmitters in the hazardous area and repeats these currents in either the non-hazardous area or zone 2, whilst restricting the transfer of energy from unspecified non-hazardous area or zone 2 mounted equipment to the connected transmitter by means of limitation of current and voltage. The equipment also allows bi-directional signal communication between the hazardous and non-hazardous area by connection of a hand-held communicator (HHC). The MTL5544 Repeater Power Supply, 4/20mA for 2 or 3-Wire Transmitters comprises four isolating transformers that provide galvanic isolation between the hazardous and non-hazardous area circuitry, zener diode chains and resistors providing voltage and current limitation. The above, together with other electronic components, are mounted on a single printed circuit board (PCB) and housed in a moulded plastic enclosure designed to be mounted on a DIN rail. Polarised plug and sockets are provided for hazardous and non-hazardous area connections. An LED is fitted to provide power on indication. The MTL5541 Repeater Power Supply, 4/20mA for 2 or 3-Wire Transmitters is a depopulated version of the MTL5544 and has only one channel populated. Both model variants are built on a common PCB. This certificate covers the installation of the MTL5541 and MTL5544 Repeater Power Supply, 4/20mA for 2 or 3-Wire Transmitters (IECEx BAS 07.0069) in a Zone 2 location. See Page 4 for electrical parameters. SPECIFIC CONDITIONS OF USE: YES as shown below: 1") The equipment must be installed in an area of not more than Pollution Degree 2 as defined in IEC 60664-1, and in an enclosure that provides a degree of protection of at least IP54 and meets the relevant requirements of IEC 60079-0 and IEC 60079-15. 2) All connections to the equipment must not be inserted or removed unless either the area in which the equipment is installed is known to be non-hazardous, or the circuit to which it is connected has been de-energised.

Issue No.: 1 Page 4 of 5 EQUIPMENT(continued): hlput / Output Parameters Power Supply Input - Terminals 13 & 14 Supply Voltage Range =20-35V d.c. 4/20mA Signal Output - Terminals 11 & 12 (Ch.1) or Terminals 8 & 9 (Ch.2 - MTL5544 only) For 20mA nominal output, the maximum load is 4500 For 24mA nominal output, the maximum load is 3600 Transmitter Inputs Terminals 1 & 2 (Ch.1) or Terminals 4 & 5 (Ch.2 - MTL5544 only) Maximum output voltage =28V d.c. Terminals 1 & 3 (Ch.1) or Terminals 4 & 6 (Ch.2 - MTL5544 only) Maximum output voltage = 1.1V d.c. Maximum input voltage = 30V d.c. Terminals 2 & 3 (Ch.1) or Terminals 5 &6 (Ch.2 - MTL5544 only) Maximum output voltage =28V d.c. Or The maximum values for the intrinsically safe circuits have to be taken from No. IECEx BAS 07.0069.

Issue No.: 1 Page 5 of 5 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 1.1 To permit the manufacturer's name to be changed on the certificate and equipment marking. No other changes are made to the equipment design. ExTR: GB/BAS/ExTR16.0242/00 File Reference: 16/0371