SQM5 Reversing Actuator with Analog Input Signal

Similar documents
SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return

Terminal Equipment Controller Enclosure

N20, N34 Series Non-Spring Return Direct Coupled Actuators

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

COMMERCIAL. VAM24-90-(A) Series

RDF Series Room Temperature Controllers

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Actuator Commissioning Tool

Installation & Operation Guide

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

LCx-xxxAx-8.08 Linear. Installation. Contents. Mounting: Short Instruction LCx-xxxAx Connecting Power and Signal

SED2 Variable Frequency Drives

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

Room Pressurization Controller Pneumatic Output

ASI Systems ML5740A Series

ASI Systems ML5720A Series

PXC Compact Unitary Equipment Controller (UEC)

Screw. Nut Guide. Features

Replacement Instructions

Room Pressurization Controller Electronic Output

ColorMaxLP Label Roll Rewinder

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Power Supply, 17-inch

Installation, Maintenance and Operating Instructions

S05, S10, S20 Series Spring Return Direct Coupled Actuators

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Field Service Procedure - Pol Motor Kit, XX97, XX97A, XX97B, XX00 & XX00B

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

Rev 7 January DR5x1, 6DR5x2 (x = 0,1,2,3,5,6)

RCx-xxxAx Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

SERIES 5 TABLES/BENCH

Print Head Replacement and Adjustment Guide for the CD Printer Revision C

II. Programming and Adjustments

JAN 16 Rev B

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Siemens TEC Extended I/O Controller

DUTY, UNIVERSAL ON/OFF & MODULATING ELECTRIC ACTUATORS

MicroTorque Precision Electric Rotary Actuator. Instruction Manual

Power Cable. Low-Voltage Cable

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Rack Installation Instructions

Peel/Rewind Upgrade Kit

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Assembly Instructions: ASUS* Z62F

Power consumption In operation At rest For wire sizing

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

Written By: John Sutton

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

LED Maintenance Instructions

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

OLPC XO-4 Touch Touchpad Controller Replacement

Upgrade Instructions Printer Terminal Holder

PD Way Pan/Tilt Head. You re on steady ground

Hard Drive, 20-inch. Replacement Instructions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

To connect the AC adapter:

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

In-Sight 7000 Series Vision System. Optional Configurations

VMC Touch: Mounting Monitor Bracket Ports Connection And Cables Installation

IBM. Rack Installation Instructions

Removal and Installation 8

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

MG586 Calibration and Maintenance

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Removing and Replacing Parts

Removal and Installation8

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

LTEC Heat Pump DDC Controller

A-dec 584 Monitor Mount on a Central Cabinet

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Air damper actuators

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Dell Inspiron 1521 Display Assembly

Stepper Motor Driver Board. Instruction Note

G12/G12x USER S MANUAL

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Contents. MicroDome Recess Mount Installation. Arecont Vision MicroDome Installation Manual

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Replacing the Power Supply

User Manual CS-SA Series 'SUPER ANALOG' Time Fade Stations JOHNSON SYSTEMS INC.

Transcription:

Document o. 129-4 June 1, 25 SQ5 Reversing Actuator with Analog Input Signal Product Description Reversing actuator used to position flow control valves, butterfly valves, dampers, or any application requiring rotary motion with an analog input signal. Product umbers SQ5x.xxxRxGx for 4 to 2 ma input signal SQ5x.xxxRxHx for to 135 ohm input signal SQ5x.xxxRxKx for to 1 Vdc input signal Actuator Torque: SQ5.2 SQ5.3 SQ5.4 SQ53.4 SQ56.5 SQ56.6 9 in/lb 9 in/lb 14 in/lb 2 in/lb 31 in/lb 4 in/lb ax Shaft Torque: AGA58.1 AGA58.3 AGA58.4 AGA58.7 2 in/lb 22 in/lb 27 in/lb 4 in/lb SQ motors allow torque on either end of the AGA58.3 and AGA58.4 shafts. For detailed information, see Technical Instructions 155-517P25. Caution otations CAUTIO: Installation Cover Removal Equipment damage may occur if procedures are not followed as specified. Use a Phillips screwdriver to loosen the two screws on the actuator cover corners. See Figure 1. Lift the screws and raise the cover. See Figure 2. EA564R1 EA568R1 Figure 1. Figure 2. Rotational Direction Verification Actuator model numbers that end with R are factory configured for clockwise (cw), minimum to maximum rotation when facing the gear end of the actuator, or counterclockwise (ccw) rotation when facing the other end of the actuator. The gear end of the actuator is the side opposite of the visual position indicator. Actuator ounting SQ5 actuators can be mounted in any orientation. Optional base mounting brackets are available. SQ5 actuators can also be face-mounted using self-tapping screws in combination with the various holes on the face of the actuator gear end. Switch Adjustment SQ5 actuators are factory-wired with Switch I (maximum), Switch II (fully closed/economy position) and Switch III (minimum/low-fire). The individual switch cams I, II, and III are factory set to 9, and 1, respectively. See Figures 3 and 4. Item umber 129-4, Rev. 1 Page 1 of 5

Document o. 129-4 June 1, 25 ACTUATOR POSITIO SCALE ACTUATOR POSITIO IDICATIG POITER SWITCH CA I SET AT IU SWITCH CA II SET AT ZERO ("ECOO") SWITCH CA III SET AT IU CA DRU DIAL POITER ASZ... (1 Ohm) FEEDBACK POTETIOETER ACTUATOR POSITIO IDICATIG DIAL CA DRU RELEASE BUTTO 1 1 5 3 5 3 5 3 3 5 7 1 1 1 GEAR ED SIGLE SWITCH CA POITER DOUBLE SWITCH CA POITER EA561R3 Figure 3. Component Identification on the Cam Drum Side of the SQ5 Actuator. The single switch cam pointers are used together with the black scales when configured for ccw operation. The double switch cam pointers are used together with the red scales when configured for cw operation. The individual switch cams can be adjusted by hand or with the use of the tool attached to the outside of the hinged switch terminal protection lid. The adjustable range of the switches is limited by the potentiometer range. SQ5x.xxxRxx3 actuators have a 9 potentiometer and the switches must be adjusted between and 9. SQ5x.xxxRxx4 actuators have a 135 potentiometer and the switches must be adjusted between and 135. Shaft Adjustment The actuator shaft can be disengaged by pressing the silver shaft release button. The shaft release button is located above the grounding screw, under the hinged terminal protection cover, and to the right of the auto/manual switch. After pressing the shaft release button in and slightly upward, the shaft can be manually rotated. After the shaft has been manually Page 2 of 5 aligned to the closed position, re-engage the shaft by pushing the shaft release button downwards. Cam Drum Adjustment Once the shaft has been set to the closed position, the cam drum must be manually aligned by pressing and holding the black cam drum release button (see Figure 3). Rotate the cam drum until the mark on the actuator position scale (left scale on the cam drum) is aligned with the gray actuator position indicating pointer. Position Indicating Dial Adjustment The actual position of the SQ5 actuator is indicated by the gray actuator position indicating pointer (see Figure 3). The position is also displayed by the indicating dial through the housing s window. Ensure that the actuator position indicating dial is aligned with the actuator position scale. If necessary, rotate the dial in the clockwise direction. CAUTIO: Turning the dial in the counterclockwise direction may loosen the potentiometer locking screw. Siemens Building Technologies, Inc.

Document o. 129-4 June 1, 25 Electrical Connection SQ5 actuators are equipped with two removable conduit connection plates located on the upper corner of the gear housing. Each plate is provided with two threaded connections for 1/2-inch PS conduit connectors. The use of flexible 14 gauge or smaller stranded wire is recommended. SQ5 Actuators require a single-source, single-phase power supply. Grounding To avoid electro-magnetic interference, SQ5 actuators must be grounded. The ground screw is located to the right of the AUTO/A switch (below the shaft release button). CAUTIO: Disconnect the circuit board wire marked 51 during high voltage testing. Reconnect it to the grounding terminal after the test. A L Z 13 ZL LR AGA56.4... + - AGA56.41... ("G" board 4...2 ma) REG OPE U W B (+2 V) 135 Ohm...2 V R AGA56.42... ("H" board -135 Ohm) 51 AGA56.43... ("K" board...1 V) shown in auto position A AUTO 1 2 13 3 actuator switch I aximum/high fire II "Economy"/Fully closed III inimum/low fire IV...VI Auxilliary blue black brown for ccw rotation EA556R4 1 2 3 4 5 I II III IV V 11 21 12 22 13 23 21 12 wire leads 14 24 15 25 VI 6 16 26 c b a ASZ... (1 Ohm) Figure 4. Basic Functional Diagram of AGA56.4 OPE - + ZL 13 LR A Z L OPE U ZL 13 LR A Z L A. AUTO. A. AUTO. EA553R4 AGA56.41A... "G" Board 4 to 2mA EA552R4 AGA56.42A... "H" Board to 135 ohm OPE LR A 3 Pos 13 L Z ZL L Z L A. AUTO. EA578R4 AGA56.43A... "K" Board to 1V Figure 5. AGA56.41/42/43 Terminal and Trim Potentiometer Boards. Siemens Building Technologies, Inc. Page 3 of 5

Document o. 129-4 June 1, 25 Commissioning anual Operation 1. Set the AUTO/A switch in the A position. 2. Connect ground to the screw located below the shaft release button. 3. Connect neutral to terminal. 4. Only terminal "L" must be powered to enable manual operation. The actuator can now be driven to the maximum (high fire) position (switch cam I) or the fully closed "economy position" (switch cam II) by using the toggle switch located to the left of the AUTO/A switch. Automatic Operation 1. Set the AUTO/A switch in the AUTO position. 2. Connect ground to the screw located below the shaft release button. 3. Connect neutral to terminal. 4. Connect line voltage at all times to terminal L to provide power to the electronic circuit board. 5. Connect line voltage to terminal LR to provide power when modulating. Connect line voltage to Terminal LR only after removing power on terminals A and Z (otherwise actuator damage may result). 6. Connect line voltage to terminal A to drive the actuator to the maximum (high fire purge) position. Once the maximum position is reached, terminal 11 (on switch I) will be energized to provide position feedback. 7. Connect power to terminal ZL to drive the actuator to the minimum (low-fire) position. Once the minimum position is reached, terminal 23 (on switch III) will be energized to provide position feedback. Adjustment of switch III will determine the low-fire stop position. Switch III (low fire) must be set at a higher position than switch II (fully closed). Terminal ZL may be energized only after removing power from terminals A, Z, 13, and LR. 8. Connect line voltage to terminal Z to drive the actuator to the fully closed/economy position (switch II). CAUTIO: Under no circumstances should terminals A and Z be powered at the same time. Actuator damage will occur. 9. Connect the input control signal wires to the appropriate terminals. See Figure 4. odulation Adjustment The blue trim potentiometers allow the adjustment of the minimum (zero) and maximum (span) positions. The factory setting of the trim potentiometer is rotated fully counter clockwise. The factory setting of the trim potentiometer is rotated fully clockwise. Zero Adjustment Set the OPE// slide switch to (See Figure 5). The blue trim potentiometer can now be gently adjusted to the required minimum position. Return the OPE// slide switch to OPE for operation. Span Adjustment Set the OPE// slide switch to. The blue trim potentiometer can now be gently adjusted to the required maximum position. Return the OPE// slide switch to OPE for operation. 9 deg. EA562R1 Switch I setting trim potentiometer setting Example of limit switch I and III and trim potentiometer settings trim potentiometer setting Switch III setting deg. Figure 6. Switch Cam and Trim Potentiometer Setting. The actual minimum and maximum modulating range is determined by either the setting of the and trim potentiometers, or the setting of Switch Cam III (inimum) and Switch Cam I (aximum). The actuator can never modulate outside of the range set by switch cam I and III. If the and trim potentiometers are set outside the setting range of switch cams I and III, then the switch cam settings determine the modulating range (See Figure 6). Page 4 of 5 Siemens Building Technologies, Inc.

Document o. 129-4 June 1, 25 Switch Cam I must not be set higher than: 9 when using feedback potentiometers ASZxx..83 or ASZxx.3; 135 when using feedback potentiometers ASZxx.833 or ASXxx.33 Cover Installation Lift the two screws on the cover corners and slide the cover end into the groove at the gear end of the actuator. See Figure 7. Press the cover into place and then press the screws inward and tighten. See Figure 8. EA567R1 EA563R1 Figure 7. Figure 8. The installation is now complete. Dimensions ALLOW 3.5" SPACE FOR COVER REOVAL 5/8 (16) Pg 13.5 / 1/2" PS 1-3/16 (3) 1/4 (6) 8 5-1/4 (133) 1-3/16 (3) 3/8 (1) 1-7/16 (36) 2-5/8 (67) EA522R1 7-1/16 (18) 7-1/16 (18) 1/16 (1) 4-7/16 (113) 1/4"-2 UC 3-1/8 (8) 1/8 (3.5) 5-3/16 (132) EA542R2 5/16 (8.5) 6-7/16 (164) 5/16 (7.5) Figure 6. SQ5x.xxxRxx Dimensions in Inches (illimeters). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 25 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. 1 Deerfield Parkway Buffalo Grove, IL 689-4513 U.S.A. our feedback is important to us. If you have comments about this document, please send Document o. 129-4 Country of Origin: US them to technical.editor@peconet.com Page 5 of 5

Represented By: POWER EQUIPET COPA 211 Williamsburg Road Richmond, VA 23231 Ph. 84-236-38 Fx. 84-236-3882 www.peconet.com