Frequency split metal artifact reduction (FSMAR) in computed tomography

Similar documents
Moving Metal Artifact Reduction for Cone-Beam CT (CBCT) Scans of the Thorax Region

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Fast iterative beam hardening correction based on frequency splitting in computed tomography

Carestream s 2 nd Generation Metal Artifact Reduction Software (CMAR 2)

Scatter Correction Methods in Dimensional CT

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

DUE to beam polychromacity in CT and the energy dependence

Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices

Tomographic Reconstruction

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Scaling Calibration in the ATRACT Algorithm

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

A new calibration-free beam hardening reduction method for industrial CT

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement

The Near Future in Cardiac CT Image Reconstruction

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Towards full-body X-ray images

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

Digital Image Processing

Metal artifact reduction in CT using fusion based prior image.

CT Reconstruction Using Spectral and Morphological Prior Knowledge: Application to Imaging the Prosthetic Knee

Iterative CT Reconstruction Using Curvelet-Based Regularization

Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-arm CT

Edge-Preserving Denoising for Segmentation in CT-Images

ML reconstruction for CT

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

Suitability of a new alignment correction method for industrial CT

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Respiratory Motion Compensation for C-arm CT Liver Imaging

Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images

CT Iterative Reconstruction Techniques

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury

Computer-Tomography II: Image reconstruction and applications

Enhancement Image Quality of CT Using Single Slice Spiral Technique

Ch. 4 Physical Principles of CT

Prostate Detection Using Principal Component Analysis

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

K Means Clustering Using Localized Histogram Analysis and Multiple Assignment. Michael Bryson 4/18/2007

Whole Body MRI Intensity Standardization

REMOVAL OF THE EFFECT OF COMPTON SCATTERING IN 3-D WHOLE BODY POSITRON EMISSION TOMOGRAPHY BY MONTE CARLO

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Non-Stationary CT Image Noise Spectrum Analysis

Metal Artifact Reduction for Multi-Material Objects

Central Slice Theorem

Evaluation of two commercial CT metal artifact reduction algorithms for use in proton radiotherapy treatment planning in the head and neck area

Metal Streak Artifacts in X-ray Computed Tomography: A Simulation Study

Reconstruction in CT and relation to other imaging modalities

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Applying Hounsfield unit density calibration in SkyScan CT-analyser

A new calibration-free beam hardening reduction method for industrial CT

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Towards Projector-based Visualization for Computer-assisted CABG at the Open Heart

AAPM Standard of Practice: CT Protocol Review Physicist

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Application of level set based method for segmentation of blood vessels in angiography images

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Artifacts in Spiral X-ray CT Scanners: Problems and Solutions

FINDING THE TRUE EDGE IN CTA

Accelerated quantitative multi-material beam hardening correction(bhc) in cone-beam CT

Introduction to Medical Image Processing

EE795: Computer Vision and Intelligent Systems

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

Streak artifacts arising from metal implants such as dental fillings, surgical clips, coils, wires, and orthopedic hardware may obscure important diag

DUAL energy X-ray radiography [1] can be used to separate

AIDR 3D Iterative Reconstruction:

Advanced Multi Material Decomposition of Dual Energy in Computed Tomography Image

Regularized Energy Minimization Models in Image Processing. Tibor Lukić. Faculty of Technical Sciences, University of Novi Sad, Serbia

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image

GPU implementation for rapid iterative image reconstruction algorithm

Investigation on reconstruction methods applied to 3D terahertz computed Tomography

Computer Graphics. Sampling Theory & Anti-Aliasing. Philipp Slusallek

A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT

Acknowledgments and financial disclosure

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Fundamentals of CT imaging

Incorporation of Prior Knowledge for Region of Change Imaging from Sparse Scan Data in Image-Guided Surgery

HIP IMPLANT METAL ARTIFACT REDUCTION FOR PELVIC CT SCANS

Automated segmentation methods for liver analysis in oncology applications

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

J. Ling Chinese Academy of Science Institute for Ceramics Shanghai, China

Sampling, Aliasing, & Mipmaps

Kinematic Analysis of Lumbar Spine Undergoing Extension and Dynamic Neural Foramina Cross Section Measurement

Constructing System Matrices for SPECT Simulations and Reconstructions

Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging

Integrated proton-photon treatment planning

A Comparative Study of Two Methods for the Correction of Beam Hardening Artifacts in X-ray Computed Tomography

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Diagnostic quality of time-averaged ECG-gated CT data

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Hybrid filters for medical image reconstruction

Self-Calibration of Cone-Beam CT Using 3D-2D Image Registration

Transcription:

The Johns Hopkins University Advanced Computer Integrated Surgery Group 4 Metal Artifact Removal in C-arm Cone-Beam CT Paper Seminar Critical Review of Frequency split metal artifact reduction (FSMAR) in computed tomography Esther Meyer, Rainer Raupach, Michael Lell, Bernhard Schmidt, Marc Kachelrieß. Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany. Published in The International Journal of Medical Physics Research, April 2012. Seminar Presented By: Marta Wells Project Partner: Carolina Cay-Martinez Project Advisors: Jeffrey H. Siewerdsen, Ph.D. Martin Radvany, MD (Interventional Radiology) Tina Ehtiati, Ph.D. (Siemens

CIS II Project Background A number of prevalent pathologies presenting a major disease burden, including arterial aneurysms, stenosis, and AVMs, may be treated with a variety of interventional techniques, including clips, coiling, stenting, and other measures. Such interventions are often performed with spatial localization and guidance provided by X- ray CT imaging methods available in the interventional suite. However, the interventions often utilize devices consisting of dense material (metal) that can result in artifacts that degrade CT image quality due to effects such as photon starvation and beam hardening. Such artifacts can challenge the visibility of structures of interest and reduce the precision and effectiveness of the intervention. As such, the development of effective metal artifact correction techniques is necessary; many MAR methods have been developed and are ready for clinical testing. Prior to clinical trials with such MAR techniques, quantitative analysis of their performance is essential. Our project, Metal Artifact Removal in C-arm Cone-Beam CT, undertakes such quantitative assessment by testing a recently developed MAR technique in neurovascular interventions (e.g., treatment of aneurysms with surgical clips and coils) guided by tomographic x-ray imaging (e.g., cone-beam CT on a Zeego C-arm) using custom phantoms designed to emulate pertinent clinical scenarios and provide quantitative analysis of image quality and accuracy. Paper Selection The paper I have chosen for critical review is Frequency split metal artifact reduction (FSMAR) in computed tomography by Meyer et al., published in The International Journal of Medical Physics Research in April of 2012. This paper aims to present a new MAR technique, frequency split metal artifact reduction (FSMAR), that ensures efficient reduction of metal artifacts at high image quality with enhanced preservation of details close to metal implants. With regards to our own project, this paper is highly relevant as it explicitly outlines the implementation of the FSMAR method and compares the effectiveness of various combinations of MAR method options. In our project, we hope to assess the MAR algorithm available on the Siemens workstation; it could prove useful to compare the artifact reduction of the Siemens implemented MAR method to the FSMAR and other MAR techniques as a way of specifically quantifying artifact reduction. Summary of Problems Metal implants create severe artifacts that degrade image quality and reduce the diagnostic value of CT images. Standard MAR techniques are far from perfect: sinogram inpainting-based MAR methods simply remove data of the metal implants which leads to blurring and loss of critical information. Inpainting-based methods for MAR consider those parts of the projection data that are affected by metal as completely unreliable. This assumption that the data from the metal trace are useless is only valid for very thick and dense implants where photon starvation occurs. The region close to metal implants is often not well corrected when inpainting-based MAR methods are used. Examples of CT images with metal artifacts. The arrows indicate the position of the metal implants. From left to right, a patient with bilateral hip prosthesis, one with neurocoil, with spine fixation, and with dental fillings is shown. Image provided by Meyer et al.

Technical Background Metal artifacts represent the extremes of the beam hardening phenomenon since the complete attenuation of the beam results in gaps on the data from these shadows in the projection data. When using a filtered-backprojection method, these gaps in the projection data produce dark bands on the images around the metallic object. Sinogram inpainting methods are the most common MAR technique employed to correct such metal artifacts. These methods utilize interpolation or forward projections to complete the sinogram, where metal-affected values are treated as missing data. The first step to reduce the existing metal artifacts consists of a segmentation of the metal trace. Metal objects are labeled in a preliminary filtered backprojection reconstruction through the use of a simple threshold segmentation. Then, a forward projection of the metal-only image is calculated resulting in a sinogram mask. All sinogram values that are different from zero in this mask are assumed to be inconsistent. Next, the inconsistent data is replaced through a two-dimensional sinogram restoration technique. The gap inside the sinogram data, the inpainting region, is filled in such a way that it is not detectable in the resulting image. After a number of iterations of inpainting, the repaired sinogram data are reconstructed. However, this method tends to introduce new streak artifacts during sinogram restoration. The origin of these new artifacts is related to the loss of edge information of the objects by using surrogate data. This loss of edge information affects the entire image and is not restricted to edges next to metal objects. Upper row: The original sinogram data and the corresponding reconstruction of the body phantom. Bottom row: The binary mask which depicts the distribution of the dense implants. Additionally the binary forward projection of this mask is shown. Image provided by Mueller et al. FSMAR Algorithm As depicted in the schematic diagram, the FSMAR algorithm consists of five steps, as outlined below. Image provided by Meyer et al.

1) Preprocessing An adaptive filter is applied to the raw data to reduce noise. For standard inpainting-based MAR approaches, this is unnecessary because the noisiest data, the data from the metal shadow, are completely replaced. For FSMAR, the data from the metal shadow contribute to the final image and thus, noise reduction is recommended. From this preprocessed raw data, an image f Orig is reconstructed. 2) Segmentation of metal From the image f Orig, a metal image f Metal is segmented by simple thresholding. This image contains only data for metal implants; any pixels that are not metal are set to zero. The threshold was chosen as a fixed percentage of the maximal CT value found in f Orig. 3) MAR by sinogram inpainting An image corrected by an inpainting-based MAR method is computed and designated as f MAR. The metal image, f Metal is forward projected and the locations of the positive entries from this projection dataset define the metal trace to be replaced by the inpainting method. Any MAR inpainting method can be employed here; the method of choice in this paper is normalized metal artifact reduction (NMAR). 4) Frequency Split FSMAR combines parts of the high frequencies of the image f Orig with image f MAR. The low-pass filtered images are computed by a 2D-convolution with a Gaussian G(σ) as f OrigLo = f Orig * G(σ) and f MARLo = f MAR * G(σ). The high frequencies of the images are obtained by subtracting the low-pass filtered versions: f OrigHi = f Orig - f OrigLo and f MARHi = f MAR - f MARLo. f MAR is more reliable than f Orig with respect to low frequencies as it does not contain beam hardening and scatter artifacts due to metal. f OrigHi contains the edges and fine anatomical structures as well as some remaining streak artifacts due to noise. f MARHi contains less noise, but also contains less edge details of anatomical structures close to the metal implants. Thus, a spatially varying weight is used to combine the advantages of both high-frequency images. 5) Spatial Weighting Pixels close to the metal implants are weighted higher than pixels more distant to the implants. The final FSMAR-corrected image f FSMAR is the weighted sum = + + Results (1 ), with i = 1,,I and j = 1,,J, where I is the number of rows and J the number of columns in an image. FSMAR was tested on two body phantoms and five patients with varying metal implants. For comparison, all datasets were corrected with a standard sinogram inpainting method, MAR1, and NMAR, and both with and without frequency split. Phantom images were taken with and without metal artifacts and quantitatively compared using RMSE calculations. Patient results were purely qualitative. Specific details are as follows: Hip phantom with bilateral hip prosthesis: in the region of interest surrounding the metal artifacts, the combination of MAR1 and FSMAR performs better than MAR1 alone. The combination of NMAR and FSMAR yields the lowest RMSE and can thus be considered the best performance. The FSMAR clearly restores missing data of the fine details of anatomical structures close to the metal artifacts. Patient with bilateral hip prosthesis: the uncorrected image shows dark and bright artifacts. In the MAR1 result, those artifacts are removed, but between the two prostheses and tangent to the prosthesis, some new artifacts appear. The correction with NMAR is already quite satisfactory, but parts of the bone close to the implant are blurred or disappear. In the FSNMAR result, the bone is clearly visible and has a sharp contour everywhere. Patient with unilateral hip endoprosthesis: dark artifacts emerging from the metal and from the guts are visible in the MAR1 images with and without frequency split. Several of the thinner parts of the hip bone can only be seen in the images with frequency split. FSMAR with NMAR yields the best correction.

Patient with internal spine fixation: as large parts of raw data are replaced and the implants have not a round but an elongated shape, the MAR1 and the NMAR results are relatively blurry in the closest vicinity of the screws. With the frequency split, the outline of the vertebra can be recovered. Even between the screws, there are bone structures visible, which are obscured by artifacts in the original image. Patient with dental fillings: in the MAR1 and NMAR images without frequency split, the reinserted metal implants are too small. Additionally, the edges appear artificially sharp. Using the frequency split method, the true outlines of the smaller implants are restored as the outline does not depend on the metal threshold here. However, this is an example where some details are removed by all MAR methods. Also, some parts of the artifacts are sharp enough here to be reintroduced by the frequency split. Patient after coiling of an intracranial aneurysm: the uncorrected image exhibits strong dark and bright streak artifacts, which make the region around the coil almost useless. The artifacts are removed by both MAR1 and NMAR, even if MAR1 introduces new artifacts. Close to the coil, a white ring-shaped artifact and slight blurring are visible after MAR1 and NMAR. In the frequency split versions, some slight streaks are reintroduced, but the blurring is removed. Benefits and Limitations of FSMAR FSMAR has several advantages compared to other MAR methods. In the corrected images, clear edges and fine anatomical details are recovered. As demonstrated, FSMAR can even restore structures between or within metal implants under the condition that they are sharp enough. The images exhibit a natural noise structure and no artificial image impression is created. The outline of metal implants is more accurate than after applying MAR methods that use segmentation by simple thresholding of metal but do not use edge information. In addition to a correction with an inpainting-based MAR method, FSMAR requires only the image-based filtering, multiplication, and addition of three volumes. Thus, compared to iterative methods or methods with complex inpainting schemes, the algorithm is computationally very efficient. However, in order to prove the success of FSNMAR, a more objective and extensive clinical evaluation by medical experts will be necessary. My Assessment In most cases, FSMAR does appear to produce superior results to any sinogram inpainting-based MAR method alone. Fine anatomical details and edges are obviously much more visible in most of the presented cases. However, personally, I am unconvinced by the figures presented specifically for the patient after coiling of an intracranial aneurysm. The ring-shaped artifact is removed with the FSMAR technique, but it does not appear to me that the blurring is removed with FSMAR. FSMAR seems to be more effective for large metal implants such as spine screws as opposed to small metal coils, but further clinical testing is required to be conclusive. In addition, Meyer et al. employed the same thresholding and Gaussian filtration parameters to every patient; it is necessary to test whether FSMAR could be improved even further with variable parameter sets. Finally, while the qualitative assessments of patient data is fairly convincing as to the effectiveness of FSMAR, it would be preferable to see any sort of quantitative calculation of the degree of artifact reduction in the various MAR methods. Hopefully, our project will make significant progress with regards to this final point in developing a quantitative measurement of streaking artifacts.