INNOVATE DESIGN APPLY.

Similar documents
INNOVATE DESIGN APPLY.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

CTC Low Temperature Process Chillers

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Liebert DCW CATALOGUE

Close-coupled cooling

Rittal Cooling Solutions A. Tropp

Thermal management. Thermal management

Precision Cooling. Precision Cooling Advantages

Total Modular Data Centre Solutions

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Cooling Solutions & Considerations for High Performance Computers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Next Generation Cooling

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Reducing Data Center Cooling Costs through Airflow Containment

EDGE LM XLMA Series Data Module

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Power and Cooling for Ultra-High Density Racks and Blade Servers

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

ENCLOSURE HEAT DISSIPATION

CL20 Rear Cooler. New Generation Computer Room Cooling

Liquid Cooling Package LCP Cooling Systems

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

HIGH DENSITY RACK COOLING CHOICES

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Rack cooling solutions for high density racks management, from 10 to 75 kw

Virtualization and consolidation

Rack & Enclosure Systems

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

HP Modular Cooling System: water cooling technology for high-density server installations

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

APC APPLICATION NOTE #146

Switch to Perfection

MSYS 4480 AC Systems Winter 2015

84 kw, Tier 3, Direct Expansion, 937 ft 2

ECOBAY: Closed loop water cooled server cabinet for data centers

Scalable, Secure. Jason Rylands

Driving Business Value through Enterprise Agreements and Partnering

Power & Cooling Considerations for Virtualized Environments

Green IT and Green DC

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

Cannon T4 Modular Data Center (MDC)

Recapture Capacity for Existing. and Airflow Optimization

LCP Hybrid Efficient performance with heat pipe technology

QuickSpecs. HP Modular Cooling System. Overview

DATA CENTER LIQUID COOLING

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Industry leading low energy evaporative fresh air cooling.

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

One Stop Cooling Solution. Ben Tam Business Development Manager

A Green Approach. Thermal

Welcome Association of Energy Engineers to the Microsoft Technology Center

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Data Center Optimized Controls

IT Air Conditioning Units

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

FREEING HPC FROM THE DATACENTRE

How to Increase Data Center Efficiency

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Ecotel Free Cool 5-15kW

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Closed-Loop Water-Cooled Enclosure GL840ES-3048-CLWCE. High Performance 30kW Closed-Loop Water-Cooled Enclosure COOL THE SERVERS, NOT THE ROOM!

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

MP7. Uninterruptible Power Supply

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Liebert PDX from 15 to 120 kw

Liquid Cooling Package LCP Cooling Systems

RiMatrix S Make easy.

DATA CENTER COLOCATION BUILD VS. BUY

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

APC by Schneider Electric Elite Data Centre Partner

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Impact of Air Containment Systems

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

ASHRAE Data Center Standards: An Overview

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Transcription:

INNOVATE DESIGN APPLY By

A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues to advance, traditional methods of cooling racks such as CRAC/CRAH, containment, hot/cold aisles, and in-row systems have become less appealing as densities increase. The Motivair ChilledDoor Rack Cooling System is an active heat exchanger that is mounted directly to the rear panel of any standard server rack. It is capable of removing lower densities up to 75kW per rack. A comprehensive set of environmental variables are constantly monitored to ensure that the ChilledDoor is actively adjusting to conditions inside the data center. By removing the heat load at its source, Motivair s ChilledDoor system ensures that all heat being generated by the servers is neutralized before it leaves the cabinet. The result is a Heat Neutral white space. Traditional cooling methods are eliminated, the data center cooling footprint is reduced, raised flooring is no longer necessary, and overall data center efficiencies can be increased by up to 90%. Because the ChilledDoor works in tandem with the IT hardware fans, the fan s power consumption and the internal operating temperature decreases, resulting in increased energy savings and longevity of the IT equipment. The Motivair ChilledDoor system operates above the ambient dew point, which eliminates the possibility of condensation near critical electrical equipment. INNOVATIVE PRODUCTS DESIGN FLEXIBILITY High Density Rack Cooling Up to 75kW per rack 100% heat removal Rack agnostic Built in scalability We were in search of a cooling solution for high density computing in a 10,000 sq ft facility. The ChilledDoor s did not take up additional aisle space allowing us to place more equipment on the floor while keeping our cost per kw down. D an Allen VP Facilities & Engineering, LightBound

Active Rack Cooling. Redefine Your PUE. ULTRA EFFICIENT EC fans dynamically adjust to compensate for changing densities. Capable of removing up to 75kW per rack. How it works Motivair ChilledDoors can be fitted to the back of any standard or OEM server rack. ChilledDoors have been designed to remove heat generated by the IT equipment directly at its source, preventing hot air from entering the white space. This ensures optimal thermal and energy performance. Room air is pulled into the cabinet via the ChilledDoor s EC fans. The room air picks up heat as it passes through the servers and then enters the ChilledDoor s high efficiency heat exchanger. The heat is transferred to the coolant inside the heat exchanger and sent out to the chilled water source (see exploded view example). The ChilledDoor then exhausts cool air back to the room at a predetermined set point. The ChilledDoor monitors the server air temperature or pressure, ambient room temperature, entering water temperature, and leaving air temperature, allowing it to actively adjust to changes at the rack level. By doing this it creates a heat neutral environment requiring only humidity control. Motivair ChilledDoors are available with 2-5 fans providing maximum scalability and flexibility for future growth. The ChilledDoor comes in seven different models including the M4, M8, M12, M12-SP, M14, G2 and M16. Motivair has the solution to meet all of your rack cooling needs today and in the future. SCALABLE Designed for single unit buildup and interchangeable models allowing for future growth. Active ChilledDoors can be leveraged for greenfield or retrofit applications, including hot spots or efficiency upgrades. They are designed for high-efficiency cooling of complete data centers in an every-rack or every-otherrack configuration (please consult Motivair for everyother-rack designs). Because the ChilledDoor is able to control an entire room, the user no longer has a need for traditional supplemental cooling solutions. RACK AGNOSTIC Designed for use with any industry standard server rack. Ideal for retrofits or new facilities. Exploded View of Chilled Door

Features INNOVATE DESIGN APPLY PLC Control System Simple navigation, adjustable set points and alarms provide you with individual ChilledDoor setup, control, and monitoring. Low Profile Footprint Maximum cooling, compact design. Hot Swappable Fans Allows for quick service replacement with no downtime. Interface Frame Mounting System Seamless integration with your server rack. LED Status Indicator Provides your data center team with visual ChilledDoor status.

Active Rack Cooling. Redefine Your PUE. ULTRA EFFICIENT EC fans dynamically adjust to compensate for changing densities. Capable of removing up to 75kW per rack. How it works Motivair ChilledDoors can be fitted to the back of any standard or OEM server rack. ChilledDoors have been designed to remove heat generated by the IT equipment directly at its source, preventing hot air from entering the white space. This ensures optimal thermal and energy performance. Room air is pulled into the cabinet via the ChilledDoor s EC fans. The room air picks up heat as it passes through the servers and then enters the ChilledDoor s high efficiency heat exchanger. The heat is transferred to the coolant inside the heat exchanger and sent out to the chilled water source (see exploded view example). The ChilledDoor then exhausts cool air back to the room at a predetermined set point. The ChilledDoor monitors the server air temperature or pressure, ambient room temperature, entering water temperature, and leaving air temperature, allowing it to actively adjust to changes at the rack level. By doing this it creates a heat neutral environment requiring only humidity control. Motivair ChilledDoors are available with 2-5 fans providing maximum scalability and flexibility for future growth. The ChilledDoor comes in seven different models including the M4, M8, M12, M12-SP, M14, G2 and M16. Motivair has the solution to meet all of your rack cooling needs today and in the future. SCALABLE Designed for single unit buildup and interchangeable models allowing for future growth. Active ChilledDoors can be leveraged for greenfield or retrofit applications, including hot spots or efficiency upgrades. They are designed for high-efficiency cooling of complete data centers in an every-rack or every-otherrack configuration (please consult Motivair for everyother-rack designs). Because the ChilledDoor is able to control an entire room, the user no longer has a need for traditional supplemental cooling solutions. RACK AGNOSTIC Designed for use with any industry standard server rack. Ideal for retrofits or new facilities. Exploded View of Chilled Door

INNOVATE DESIGN APPLY TECHNICAL SPECIFICATIONS AND FEATURES M4 M8 M12 M12-SP M14 G2 M16 Available Height (Range) 42U - 60U 42U - 60U 42U - 60U 42U - 60U 42U - 60U 48U - 60U 48U - 60U Available Width (Range) 600-800MM 600-800MM 600-800MM 600-800MM 600-800MM 762-800MM 762-800MM (Outside Dimensions) (23-31 ) (23-31 ) (23-31 ) (23-31 ) (23-31 ) (30-31 ) (30-31 ) Depth (Inches) 13.3 13.3 13.3 13.3 15.7 16.8 18.8 Nominal Cooling Capacity (kw)* 12 30 45 55 65 70 75 GPM (Range) 0-23 0-23 0-23 0-23 0-23 0-23 0-23 Max Watts 840 840 840 840 2500 840 2500 Fan Quantity 2-5 5 5 5 5 5 5 Power Supply: 230V/1PH/50-60HZ S S S S S S S 208V/1PH/60HZ S S S S S S S 277V/1PH/50-60HZ O O O O S S FEATURES *Calculated at 35% RH and 75F Room Temp; Supply Temperature Range 55F - 65F water; 100% water PLC with local HMI screen S S S S S S S Variable EC fans S S S S S S S Dual power supply (A/B) O O O O O O O Network remote monitoring/control O O O O O O O Individual fan fail sensing S S S S S S S Local visual/audible alarm S S S S S S S Leak Prevention System/Detection S S S S S S S Modulating Two-Way Valve S S S S S S S Common Alarm Relay S S S S S S S Top or Bottom Connections S S S S S S S Differential Pressure Control O O O O O O O 100% Failover Mode S S S S S S S Overcool Mode S S S S S S S C14 Plug Type S S S S S S S Alternative Plug Types available O O O O O O O Rack Access (Key) S S S S S S S Rack Access (Code) O O O O O O O FACTORY CERTIFIED SERVICES Installation O O O O O O O Start-Up O O O O O O O Commissioning Support O O O O O O O Warranty (Parts) O O O O O O O Preventative Maintenance O O O O O O O Open19 and OCP compliant. S=Standard; O=Optional ETL, CSA, CE Certified Manufactured in the USA 2016 Motivair Corporation. Motivair reserves the right to modify specifications without notice. Reproduction of this brochure in whole or part is prohibited.

OUR BUSINESS IS COOLING YOURS Coolant Distribution Unit (CDU) A CDU provides the ability to deploy higher density, load diverse IT equipment in a smaller footprint while at the same time improving a facility s overall efficiency (PUE) and life expectancy. The CDU provides 100% sensible cooling up to 1.25MW, depending on the model. For use with the ChilledDoor or other IT cooling systems. In-Rack Coolant Distribution Unit (CDU) Motivair s latest MCDU-4U provides all the benefits of a CDU, but can be mounted within a standard 19 rack enclosure. With a cooling capacity of 80kW (with ChilledDoor ) and 105kW (with other IT computer cooling systems), the MCDU-4U is ideal for smaller IT deployments, areas with space constraints, or to address hot spots in air-cooled data centers. Manifold Systems A manifold provides a common connection point between the ChilledDoors and the supply and return cooling infrastructure system or CDU. It is typically installed under the raised floor, but can be hung overhead for installations without raised floors. Each manifold is preconfigured with quick connect fittings for use with Motivair hoses and individual 2-way valves for each door. Available options include 6,12 and 16 port assemblies. Motivair Free-Cooling Chillers The Motivair Free-Cooling chillers were created to serve year-round mission critical cooling loads for data centers. Generations of Free Cooling chiller software design and implementation allow for optimal water side economizing hours, rapid restart after power failure, and tight temperature control during extreme year-round weather patterns. ChilledDoor Critical Environment Cooling Services Expertise, service and support for your mission critical facility Service & Maintenance Program Motivair provides customer-focused service and support for your mission critical equipment. We offer site surveys, installation services, commissioning services, service agreements, and extended warranties on parts. ChilledDoor Rack Cooling System Printed on Recycled Stock with 10% Post Consumer Fiber. 0090102 85 Woodridge Drive Amherst, NY 14228 Tel: 716-691-9222 Fax: 716-691-9229 www.motivaircorp.com