FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Similar documents
Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

Input/Output Module (IOM) Series Catalog Page

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

FX-PCA Advanced Application Programmable Controller Catalog Page

Advanced Application Field Equipment Controller (FAC) Catalog Page

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

FX-PC Series Programmable Controllers and Related Products Product Bulletin

VMA Programmable VAV Box Controllers Catalog Page Code No. LIT Issued February 2018

PEAK TM. SMART Equipment Controllers. Product bulletin

FX-PC Series Programmable Controllers and Related Products Product Bulletin

VMA Programmable VAV Box Controllers Catalog Page

Network Control Engine Catalog Page

FX Input/Output (I/O) Modules XM07 and XM14

Smart Equipment Controls (SEC)

FEC26 Field Equipment Controller

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

FXVMA Variable Air Volume (VAV) Box Controller

Metasys System Field Equipment Controllers and Related Products Product Bulletin

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

FX06 Field Controller

Metasys System Field Equipment Controllers and Related Products Product Bulletin

FX-PCX17 and FX-PCX27 Expansion Input/Output Module Installation Instructions

FEC26 Extended Temperature Field Equipment Controller

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

FX-PCG26 General Purpose Programmable Controller Installation Instructions

FX-PCA3611 Advanced Application Programmable Controller Installation Instructions

Medium User Interface (MUI) Version 3

Verasys System Product Bulletin

FX-PCA Advanced Application Programmable Controller Installation Instructions

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

FAC Advanced Application Field Equipment Controller Installation Instructions

IOM47 Input/Output Module Installation Instructions Part No , Rev. K Issued April 2016

FEC25 Field Equipment Controller Installation Instructions Part No , Rev. A Issued April 2016

LN Series Remote Input/Output (I/O) Modules

Buy American Facility Explorer Products Facility Explorer Product Management Authorized Building Controls Specialists (ABCS)

Network Control Engine

FX-DIS Local Controller Display Technical Bulletin

IOM47 Input/Output Module Installation Instructions Part No , Rev. L Issued November 2017

FEC26 Field Equipment Controllers Installation Instructions MS-FEC2611-x, MS-FEC2621-x, MS-FEC2611-xET

FX14 Field Controller

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

FEC1611 and FEC1621 Field Equipment Controller Installation Instructions

LX Series Remote Input/Output (I/O) Controller

Application and Data Server (ADS) Lite-A System Catalog Page

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

TC-9102 Terminal Controller

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

IOM2721 Input/Output Module Installation Instructions MS-IOM2721

XT-9100 Technical Bulletin

VMA1610 and VMA1620 Variable Air Volume Controllers Installation Instructions

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

NCE25 Installation Instructions MS-NCE25xx-x

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Modernization Guide for N2 Controllers - Facility Explorer Code No. LIT Issued December 5, 2014

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Room Controllers. SC3000 Relay Pack

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Field selectable application type and room module series, via dip-switches on controller

DOR6. Components All functions and indications are on the front of the module. Characteristics

NS Series Network Sensors

Modular Room Control (MRC) Series Expansion Board

Network Automation Engine

Commercial Comfort System (CCS)

Priva Blue ID Digital input module DI4/DI8/DI16

8 channel universal input and 4 channel Form C digital output

BACnet. b3810 Series Local Controllers

ZFR1800 Series Wireless Field Bus System

BACnet. b3867 Terminal Controllers

Specification Sheet For electronically commutated motors

FX40 Supervisory Controller

Andover ContinuumTM. b3850 Series Terminal Controllers

Priva Blue ID Relay output module DOR4/DOR8

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

FX-PCV1615/1626/1628/1630 Programmable VAV Box Controllers Installation Instructions

Multiple Channel Approach. Marc Bertolin Regional Account Manager - Products

ECLYPSE Communication Modules

Priva Blue ID C-Line Mix input/output module MX34

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

TC Compact Series Unitary Equipment Controller

Priva Blue ID Communication module RS485 SC44

LX Series Free Programmable Controllers

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Variable Air Volume Modular Assembly (VMA) 1400 Series

ZFR1800 Series Wireless Field Bus System

WNC1800/ZFR182x Pro Series Wireless Field Bus System

Network Integration Engine

ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers

Andover ContinuumTM Infinet II

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

VZ7000 Series. BACnet Commercial Zoning System

ECLYPSE Communication Modules

Transcription:

Expansion Input/Output Modules Catalog Page Code No. LIT-1900671 Issued April 17, 015 The s are expansion I/O modules with integral RS-5 MS/TP communications. Note: At FX-PCT Release 10.1, FX-PCVs, FX-PCGs, and FX-PCAs can communicate by using either the BACnet or the N field bus networking protocol. The operation of the is not affected by the selection of the BACnet or the N protocol in the host controller. s can serve in one of two capacities, depending on where they are installed in the control system. When installed on the Sensor/Actuator (SA) Bus of an FX-PCV, FX-PCG, or FX-PCA controller, the s expand the I/O interfaces of these controllers. When installed on the Field Controller (FC) Bus, s can be used as I/O point multiplexors to support monitoring and control from a supervisory controller. The point multiplexor can also be useful for sharing points between other FX-PC controllers on the FC Bus using peer-to-peer connectivity. Refer to the FX-PC Series Programmable Controllers and Related Products Product Bulletin (LIT-1011657) or FX-PC Series Programmable Controllers and Related Products for Building Control Management (BCM) System Product Bulletin (LIT-1011915) for product application details. Features Standard BACnet Protocol with BTL Listing - Provides interoperability with Johnson Controls and third-party Building Automation System (BAS) products that use the widely accepted BACnet standard. Standard Hardware and Software Platform - Uses a common hardware design throughout the family line to support standardized wiring practices and installation workflows. Also uses a common software design to support use of a single tool for control applications, commissioning, and troubleshooting to minimize technical training. ZigBee Wireless FC/SA Bus Interface (where available) - Provides a wireless alternative to hard-wired field bus networking and sensor connections, providing application flexibility, mobility, and minimal disruption to building occupants. Universal Inputs and Configurable Outputs - Allow multiple signal options per channel to provide input/output flexibility. Complete Product Family with Modular Components - Meets any HVAC equipment or building system control requirement using only the needed components. Table 1: Series Point Type Counts Per Model Point Types Universal Input (UI) Signals Accepted Analog Input, Voltage Mode, 0 10 VDC Analog Input, Current Mode, 0 ma Analog Input, Resistive Mode, 0 k ohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI), NTC (10k Type L,.5k Type ) Binary Input, Dry Contact Maintained Mode BACnet MS/TP Protocol supports seamless integration into Johnson Controls and third-party BACnet devices. Integral end-of-line (EOL) switch enables FX-PC controller as a terminating device on the communications bus. Wireless capabilities (where available) via an FX-ZFR Series Wireless Field Bus System enable wireless mesh connectivity between FX-PC controllers to FX-WRZ Series Wireless Room Temperature Sensors and to supervisory controllers, facilitating easy initial location and relocation. Ability to reside on the FC Bus or SA Bus provides application flexibility If the product fails to operate within its specifications, replace the product. For a replacement product, contact the nearest Johnson Controls representative. 1711 711 71 Figure 1: 1711 3711 371 3731 711 6 Binary Input (BI) Dry Contact Maintained Mode 16 Pulse Counter/Accumulator Mode (High Speed), 100 Hz Analog Output (AO) Analog Output, Current Mode, 0 ma Binary Output (BO) VAC Triac 3 Expansion Input/Output Modules Catalog Page 1

Table 1: Series Point Type Counts Per Model Point Types Signals Accepted 1711 711 71 3711 371 3731 711 Universal Output (UO) Binary Output Mode, VAC/DC FET Analog Output, Current Mode, 0 ma Configurable Output (CO) Binary Output Mode, VAC Triac Relay Output (RO) (-0 Models 10/0 VAC Relay Output (RO) (-1 Models VAC, SELV Relay Output (RO) (- Models VAC Table : Series Ordering Information Product Code Number 1711-0 711-0 711-3 71-0 3711-0 3711-3 371-0 3731-0 3731-0A 1 711-0 Description -Point Expansion I/O Module with BI, FC and SA Bus Support 6-Point Expansion I/O Module with UI, UO, RO, FC and SA Bus Support. Relays are rated for 10/0 VAC. 6-Point Expansion I/O Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 0 VAC. 10-Point Expansion I/O Module with UI, AO, FC and SA Bus Support 1-Point Expansion I/O Module with UI, RO, BO, FC and SA Bus Support. Relays are rated for 10/0 VAC. 1-Point Expansion I/O Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 0 VAC. 16-Point Expansion I/O Module with 16 BI, FC and SA Bus Support 16-Point Expansion I/O Module with BI, BO, FC and SA Bus Support 16-Point Expansion I/O Module with BI, BO, FC and SA Bus Support Note: BOs on the 3731-0A controller do not supply power for the outputs; the BOs require external low-voltage (<30 VAC) power sources. 17-Point Expansion I/O Module with 6 UI, BI, 3 BO, AO, CO, VAC, FC and SA Bus Support 1 This model is currently available only in the Asian market; contact your local Johnson Controls representative for more information. UL Listed 3 CE Marked Accessories Table 3: Accessories Product Code Number FX-BTCVT-1 TL-BRTRP-0 FX-BTCVTCBL-700 Y6T15-0 Y65A13-0 Y65T-0 Y65T31-0 AP-TBKSA-0 AP-TBKFC-0 AP-TBK3PW-0 Description Bluetooth Commissioning Converter Portable BACnet/IP to MS/TP Router Cable Replacement Set for the FX-BTCVT-1 or the FX-ATV7003-0; Includes One 5 ft (1.5 m) Retractable Cable Transformer, 10/0/0 VAC Primary to VAC Secondary, 9 VA, Foot Mount, 30 in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AS), in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10/0/0 VAC Primary to VAC Secondary, 0 VA, Hub Mount (Y65SP+), in. Primary Leads and Secondary Screw Terminals, Class Transformer, 10/0/0 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AR+), in. Primary Leads and Secondary Screw Terminals, Class Replacement MS/TP SA Bus Terminal, -Position Connector, Brown, Bulk Pack Replacement MS/TP FC Bus Terminal, -Position Connector, Blue, Bulk Pack AP-TBK3PW-0 Expansion Input/Output Modules Catalog Page

Series Technical Specifications Table : Series Technical Specifications Product Code Numbers 1711-0 - -Point Expansion Input/Output Module with BI, FC and SA Bus Support. 711-0 - 6-Point Expansion Input/Output Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 10/0 VAC. 711- - 6-Point Expansion Input/Output Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 0 VAC. 71-0 - 10-Point Expansion Input/Output Module with UI, AO, FC and SA Bus Support 3711-0 - 1-Point Expansion Input/Output Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 10/0 VAC. 3711- - 1-Point Expansion Input/Output Module with UI, UO, BO, FC and SA Bus Support. Relays are rated for 0 VAC. 371-0 - 16-Point Expansion Input/Output Module with 16 BI, FC and SA Bus Support 3731-0 - 16-Point Expansion Input/Output Module with BI, BO, FC and SA Bus Support 3731-0A - 16-Point Expansion Input/Output Module with BI, BO, FC and SA Bus Support (Asia only) 711-0 - 17-Point Expansion Input/Output Module with 6 UI, BI, 3 BO, AO, CO, FC and SA Bus Support Supply Voltage Power Consumption VAC (nominal, 0 VAC minimum/30 VAC maximum), 50/60 Hz, Power Supply Class (North America), Safety Extra-Low Voltage (SELV) Europe 1 VA maximum Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs) or Configurable Outputs (COs), which can consume up to 1 VA for each BO or CO, for a possible total consumption of an additional VA (maximum), depending on the model. Ambient Conditions Operating: 0 to 50 C (3 to 1 F); 10 to 90% RH noncondensing Storage: -0 to 0 C (-0 to 176 F); 5 to 95% RH noncondensing BACnet/MS/TP Addressing DIP switch set; valid controller device addresses 17 (Device addresses 0 3 and 1 55 are reserved and not valid addresses). Communications Bus 1 BACnet MS/TP, RS-5 3-wire FC Bus between the supervisory controllers and FX-PC controllers -wire SA Bus between FX-PC controller, NS Series Network Sensors, and other sensor/actuator devices. includes a lead source 15 VDC supply power (from FX-PC controller) to bus devices. Processor Memory HSX/166xR Renesas 3-bit microcontroller 51 KB Flash Memory and 1 KB Random Access Memory (RAM) Expansion Input/Output Modules Catalog Page 3

Table : Series Technical Specifications Input and Output Capabilities 1711: - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/ Accumulator Mode 711: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, 0 ma - Relay Outputs (Single-Pole, Double-Throw): UL Listing (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; CE Marking (-1 model only): 6 () A N.O. or N.C. only, VAC, SELV CE Marking (-1 model : 6 () A N.O. or N.C. only, 0 VAC 71: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Analog Outputs: Defined as 0 10 VDC or 0 ma 3711: - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, 0 ma - Relay Outputs (Single-Pole, Double-Throw): UL Listing (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC; CE Marking (-1 model only): 6 () A N.O. or N.C. only, VAC, SELV CE Marking (- Model : 6 () A N.O. or N.C. only, 0 VAC 371: 16 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode 3731: - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode - Binary Outputs: Defined as VAC Triac (Require external low-voltage power source.) 711: 6 - Universal Inputs: Defined as 0 10 VDC, 0 ma, 0 600k ohm, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse/Counter Accumulator Mode 3 - Binary Outputs: Defined as VAC Triac (selectable internal or external source power) - Configurable Outputs: Defined as 0 10 VDC or VAC Triac BO - Analog Outputs: Defined as 0 10 VDC or 0 ma Analog Input/Analog Output Resolution and Accuracy Terminations Analog Input: 16-bit resolution Analog Output: 16-bit resolution and ±00 mv in 0 10 VDC applications Input/Output: Fixed Screw Terminal Blocks SA/FC Bus and Supply Power: -wire and 3-wire Pluggable Screw Terminal Blocks SA/FC Bus Port: RJ-1 6-Pin Modular Jacks Mounting Housing Horizontal on single 35 mm DIN rail mount (preferred), or screw mount on flat surface with three integral mounting clips on controller Enclosure material: ABS and polycarbonate UL9 5VB; self-extinguishing, Plenum-rated protection class: IP0 (IEC59) Expansion Input/Output Modules Catalog Page

Table : Series Technical Specifications Dimensions (Height x Width x Depth) 171x-x and 71x-x Models: 150 x 10 x 53 mm (5-7/ x -3/ x -1/ in.) including terminals and mounting clips 71-x, 371-x, 3731-0, and 3731-0A Models: 150 x 16 x 53 mm (5-7/ x 6-7/16 x -1/ in.) including terminals and mounting clips 371x-x and 71x-x Models: 150 x 190 x 53 mm (5-7/ x 7-1/ x -1/ in.) including terminals and mounting clips Note: Mounting space for all controllers requires an additional 50 mm ( in.) space on top, bottom, and front face of controller for easy cover removal, ventilation, and wire terminations. Weight Compliance 0.5 kg (1.1 lb) maximum United States: UL Listed, File E10701, CCN PAZX, UL 916, Energy Management Equipment; FCC Compliant to CFR7, Part 15, Subpart B, Class A Note: Except 711- and 3711- Canada: UL Listed, File E10701, CCN PAZX7, CAN/CSA C. No. 05, Signal Equipment; Industry Canada Compliant, ICES-003 Note: Except 711- and 3711- Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 00/10/EC. Note: Except 711-0 and 3711-0 Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant Note: Except 711-0 and 3711-0 BACnet International: BACnet Testing Laboratories (BTL) Protocol Revision Listed BACnet Application Specific Controller (B-ASC) 1 For more information, refer to the FX-PC Series Controllers MS/TP Communications Bus Technical Bulletin (LIT-1011670). Building Efficiency 507 E. Michigan Street, Milwaukee, WI 530 Johnson Controls is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 015 Johnson Controls, Inc. Published in U.S.A. Expansion Input/Output Modules Catalog Page www.johnsoncontrols.com 5