Using the NM150 with Adulticiding

Similar documents
Using a Windows Data Collector

Serial to LANC Adapter User s Guide

Updating Reader Firmware

APPLICATION NOTE 4633 Bluetooth to 1-Wire Communication Using the DS9097U

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

RA Triage Procedure. Product: DM8050 & DM8600 series. 1.0 Useful Components & Accessories

Reason. Solution. consumer in addition to. GPS. If GPS

TROUBLESHOOTING GUIDE

Adding Peripherals to DCS

TDS Nomad Connect To Bluetooth Instrument. Tested with Trimble Nomad with integrated Bluetooth, and Sokkia 530R3 total station.

Windows 10 Bluetooth Setup with Zebra Printers

trevolo Bluetooth Speaker User Manual

Intelligent Devices IDI 1100 Series Technical Manual

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Bluetooth TO Serial CONVERTER E-P132-B

KERN YKI-02 Version /2014 GB

3.1 I-7560 Pin Assignment and Specifications: Introduction

CG Antenna GW 1000 APRS TOTAL SOLUTION v1.2.1 User Manual

Quick Start Guide Bluetooth Serial Adapter

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Quick Start Installation Guide

RN-WIFLY-SRL-UM. WiFly Serial Adapter Roving Networks. All rights reserved. RN-WIFLY-SRL-UM-1.0 Version /11/2011 USER MANUAL

Trouble shooting the DeskCNC controller:

Troubleshooting Guide

Blue Point Engineering

KERN YKI-02 Version /2016 GB

User s Manual BTS1009C. Bluetooth to Serial Adapter. SUNIX Co., Ltd.

Installation and Configuration Guide

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

LM Technologies Ltd. Quick Start Guide LM048 and LM058 Bluetooth Serial Adapters. 1 Package Contents. 2 Setup

Jabra FREEWAY. User manual.

APS-3 Revision Important Quick Start Guide. Typical Box Contents

QwickPAY Setup for Android

User s Manual ADSL Router Modem DB Ethernet Ports

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

This guide will show you how to configure a Windows Mobile 5 PDA for Bluetooth connection to the KBM Systems OBDKey Bluetooth device.

ICP PANEL-TEC PEX3000 II

User Manual A08. User Manual

ALDL Bluetooth Adapter

Altus APS3G Quick Start guide

Specification System... 5 Display Specification... 5 I/O Connectors... 5 Buttons and Indicators... 5

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715)

FREQUENCY DRIVES ADJUSTABLE SERIES 9000 AF DRIVES. SVLoad Application. Loading Application and Option Software. Instruction Sheet

OneControl PROGRAMMING MANUAL. Rev: Page 1 OneControl Programming Manual

Figure 1: ZigBee Evaluation Kit (ZEK) Contents. Figure 2: ZigBee Adapter Zb-121 and Module Zb-21

RS-232 Serial to Bluetooth Adapter Quick Installation Guide

1320 Electronics LLC USB-ALDL Cable User s Guide Electronics LLC. User s Guide for: USB-ALDL Cable

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

ALDL Bluetooth Adapter with USB (MK2)

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

APS SCALE SERIES DIMENSIONS

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

DFS/Cutter. Debugging Communication Problems

K72448 Presentair Pro Bluetooth Presenter, Laser, & Stylus FAQ s

Wireless Modem Evaluation Board User s Guide

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

3 x 25 Watt with E14 socket. Power Class 1 (~100 meters ) Philips LPC2106 ARM7 60 MHz 47 x 23 x 12 cm. About Factorycode

Bluetooth RS-232 Adapter

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

TH100A User Manual 1 Updated October 12, 2018

WIFLY SERIAL ADAPTER RN-370 & RN-374

D8000 SERIES QUICK START GUIDE

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

CoverTitle. Raven XT. Quick Start Guide for AT&T Rev 3.0E

1. Introduction Features Specifications System Requirements of PC Package Software Installation

OneControl PROGRAMMING MANUAL

PR3 Help. Copyright <2008> <Digitrax Inc.>

3G/4G Wireless N150 Router m2

User s Guide TURBO Pinewood Derby Finish Line and Timer Release /31/2011 NewBold Products, Atlanta GA

USER MANUAL FOR GS100/GS1003G

Bluetooth RS232 Serial Adapter

Installing the Ampire UART TFT

Canlan INSTALLATION MANUAL

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Figure 1. Bluetooth System Diagram

FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual

LM058 Bluetooth Serial Adapter

Installation and Configuration Quick Guide GoRugged M1000 MP

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Windows ULV FAQ. For Mosquito & Vector Control GENERAL

LGate 120 Installation Guide - Appendix

IDWedgeBT USB Virtual Serial Port Cable Installation, Configuration and Operation

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

SR-201 Network Relay Quick Start Guide

EXPRESS. Users Guide. Version 3.5

ES-600 Ozone Controller Operation Manual

THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300)

CommLink IV Technical Guide

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.

SitePORTAL Lite TA-SPL32-R48

WIRELESS RF MODEM SETUP MANUAL FOR CARDMASTER

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

DS232. RS232 to DMX Converter V4. ELM Video Technology s RS232 to DMX Converter / Controller

Quick Installation Guide

icex-cmtm General specs and Installation guide

DOWNLOAD PDF DELL VENUE 8 PRO 5830 MANUAL

Hardware Manual RM CANview

Transcription:

Reason Adulticiding 3.5 includes support for the New Mountain NM150 Weather Station. Adulticiding fogger log point details include temperature, wind speed, and wind direction. These can be recorded from the weather station simultaneous with the sprayer data, using a Bluetooth serial adapter on Windows Mobile devices (most mobile devices do not have two 9-pin RS-232 COM ports) or a USB connection on Windows tablets. Solution Windows Mobile Device Configuration 1. Configure the FireFly Serial-Bluetooth adapter to communicate with the weather station. Note: full instructions for the FireFly are found in the FireFly User Guide. a. Power up the FireFly b. Connect it to a computer serial port using a null modem cable c. Use a TTY Terminal program (such as HyperTerminal) to configure the communication settings for the FireFly. (The default baud rate is 115,200 but the New Mountain weather station uses 4,800. It s possible to change baud rate using jumpers on the FireFly, but you can only change it to 4,800 by putting it into Command mode using HyperTerminal.) i. Connect using 115,200 baud ii. Set connection properties iii. Enter command mode by typing $$$. The device will respond with CMD. 1

$$$CMD iv. Type SU,48 to set baud to 4800. The device will respond with AOK. SU,48 AOK? v. Type --- to exit command mode. The device will respond with END. --- END 2. Power up the sprayer. 3. Connect the sprayer data cable to your mobile device. 4. Power up the weather sensor. Use the pigtail cable with the 9-pin RS-232 serial connector to connect the weather sensor up to power. Note: this cable comes with a 12-volt AC wall adapter. You will need to get a vehicle power adapter instead. A 12-volt vehicle adapter with an M-sized (2.1mm x 5.5mm) barrel plug can be purchased from electronics stores. Also note that if a serial cable extension must be used, a M-F straight through cable can be purchased from Electronic Data Solutions. 2 5. Connect the Bluetooth serial adapter to the 9-pin serial connection on the pigtail cable and secure the connection so that vibration or human interference does not disconnect it (e.g. tape

it). For our testing, we used the Bluetooth FireflyBP (male) available from GridConnect, because it has rechargeable AAA batteries. The GC-BT-FIREFLY-DTE-110 was also tested. Either device will need a DC charger (5VDC @ 1a, plug size (1.3 x 3.5 x 9.5 mm) outer cylinder is GND) to supply reliable power to the device (if an external power source is not used the FireflyBP will power off if no data communication is detected). Other Bluetooth serial adapters may be available, but they would need to be tested with the system to ensure proper setup. 6. Power up the Bluetooth adapter and put it in Discoverable mode. For the FireFlyBP, this involves pressing the red button for approximately 2 seconds until the lights begin to blink. 7. On the mobile device, go to the Bluetooth manager. (Windows tablets and Windows mobile devices have different management tools, but the following instructions will provide you the basics of what you need to know to get this set up properly.) For a Windows Mobile device, go to Settings > Connections > Bluetooth. 8. Tap on Add new device 3 9. Select the FireFlyBP and press Next.

10. Enter 1234 for the Bluetooth Passcode and press Next. 11. Give the device a moment to complete the pairing (do not enter the passcode again). Tap on the FireFlyBP device listing and select the Serial Port service. Press Save. 4

12. Tap COM Ports > New Outgoing Port. Select the FireFlyBP device and press Next. Set the COM port number (make a note of it!) and uncheck Secure Connection. Press Finish. (If you have more than one mobile device, make sure the COM port is configured the same on all of them.) 13. The Firefly devices will display disconnected once setup properly; this is normal behavior for the devices from this mfg. 14. Your Bluetooth connection and port are now configured. You should not have to perform these steps again unless you factory reset your device. 15. It is important to note the Sentinel device and the NM150/FireFly devices are a pair and must be used together as a pair. 16. In ArcMap, select Adulticiding > Mobile Application Configuration Utility. On the General tab, check the box to Read weather data from New Mountain NM150 Weather Station and set the COM Port the mobile device will use to communicate with it (from Step 12 above). 5 17. Use DataLink GIS to send updates to the mobile device(s).

18. Start Sentinel GIS Adulticiding (always make sure that the sprayer is on and connected, the weather station is on, and the Bluetooth serial adapter is on). 19. Note the flashing green light on the Firefly indicates no BT connection, once Adulticiding has started and the sprayer is powered on the Green light will turn solid. The Yellow light on the Firefly will blink when data is being sent or received from the NM150. 20. On the Adulticiding login screen, if the NM150 is enabled, the boxes for Temperature, Wind Speed and Direction will not be displayed (because the weather information will be collected with the fogger log points, not the spray session record). 21. To verify the port setting for the NM150, tap the space next to the Log In button. If the COM port needs to be changed, uncheck the Use defaults button and change the port (this will override the setting from Step 16 above on this device only). 6

22. Fill in the rest of the login details and press Log In to begin recording sprayer data. The weather connection icon will display an X until communication is established with the pump control box. Windows Tablet 1. Install the Windows 7/8/10 NM-150 drivers using the installation media that came with the weather station. 2. Power up the sprayer. 3. Connect the sprayer data cable to your mobile device and power on the sprayer. 4. Power up the weather sensor. The USB to RS-485 box must have vehicle power to communicate. 5. Plug the USB connection cable that came with the weather station mobility package into the mobile device or mobile dock. 6. Go into the Windows Device Manager on the tablet and note the COM port settings for the attached weather station. Typical COM port may be COM4, COM5, COM6; baud rate must be set to 4800 to communicate with the weather station. 7. In ArcMap, select Adulticiding > Mobile Application Configuration Utility. On the General tab, check the box to Read weather data from New Mountain NM150 Weather Station and set the COM Port the mobile device will use to communicate with it (from Step 5 above). 7

8. Use DataLink GIS to send updates to the mobile device(s). 9. Start Sentinel GIS Adulticiding on the tablet (always make sure that the sprayer power is on and connected and the weather station has power and is connected). 10. On the Adulticiding login screen, if the NM150 is enabled, the boxes for Temperature, Wind Speed and Direction will not be displayed (because the weather information will be collected with the fogger log points, not the spray session record). NM150 option not enabled NM150 option enabled 11. Fill in the rest of the login details and press Log In to begin recording sprayer data. The weather connection icon will display an X until power is supplied to the spray control box. 8

Sprayer power on and NM150 communicating Sprayer not connected or power off Troubleshooting This message indicates Sentinel is not receiving weather station data. This can be caused by several things no cable connection, no power to the NM150, incorrect port settings provided by the win7 port driver. Follow these steps to recover. 9

1. Confirm power at the NM150. The mobility module has a window with an indicator light if the light is on it indicates the NM150 has power. 2. Confirm the NM150 windows driver has assigned the same port that was assigned in step #6 a. Right click the computer icon and click properties b. Click Device manager c. Expand ports d. Check for the existance of AIRMAR USB RS422 Serial Port i. If it doesn t display start the process over and confirm connection and power. ii. If it displays but the port is different than the orginal setting go to step 5 below. e. Double click on the AIRMAR USB RS422 Serial Port f. Confirm the BAUD rate is set to 4800 and the other settings are as displayed below. 10

g. Click Advanced to change the Port number assignment and select the correct COM port number from the drop down list. h. Click ok through all boxes to get back to the main screen and start Sentinel again to confirm NM150 connection. 11