hm 3010/3020 DC-V/DC-VI

Similar documents
hm 3010/3020 DC-V/DC-VI Microprocessor-controlled rotary sealer for sterile goods packaging (validatable process according to ISO 11607)

hm 2010 / 2020 DC Microprocessor-controlled rotary sealer for medical packaging (validatable process in accordance with ISO 11607)

hm 2010 DC-V/hm 2020 DC-V/hm 2010 DC-VI

ValiPak / ValiPak TOUCH. The validatable ValiPak and ValiPakTOUCH bar sealers for The packaging of pouches and reels.

WITH SAFETY FROM A SINGLE SOURCE.

The advanced system of the MS 451PV also allows quality teams to program required stop and test

MINIMAT-EC-Servo Screwdriver Spindles

CT AUTOMATIC WINDING MACHINE

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

SM9000. Made in Germany

Operating Instructions

MInIMAT-ec. flexible data recording highly accurate

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

analysette 3 particle size analysis quality control sieving for your lab Vibratory Sieve Shaker Microprocessor controlled

Varian, Inc. Vacuum Technologies. The New Unique Varian Dry Turbo Pumping System: TPS-compact

STANDARD TERMINAL. Digital Indicators. Product Number 3020

MCX08M2 Programmable controller

Superspeed Centrifuge

HiCen XL Extra-Large High-Speed Floor Centrifuge

MINIMAT-EC-Servo Screwdriver handheld

Circuit Breaker Analyzer & Timer CAT31

ulrich medical Tourniquets

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

ULTRASONIC, CRUSH, MANUAL, ZEBRA, & VERTICAL LOUVRE CUTTERS

Timing tasks get everything from one source NEW: LED timer tico 742. Electronic Timer family. tico

Screwdriver Spindles electric. The flexible EC screwdriver for the highest standards. Screwdriving Technology Automation Air Motors Air Tools

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Neon pr. ph/ ORP measurement. Applications. Description

High-Speed Centrifuges with or without refrigeration small footprint and they fit beneath the work bench

02/11/2015

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies

Temperature Switches

PITOT / STATIC TESTER

Interface I-300 / I-300 Pro Technical data sheet

HiCen T / HiCen TR. High-Speed Tabletop Centrifuges

TEXTILE PRINTERS MACHINES MATCHING SUPPLIES ACCESSORIES

Quick Start Guide Axxin T8-ISO. Instrument. In association with: E: W: D Version 1.5

A 2 O Advanced Automated Osmometer

IKA Crushing 76 Dispersers (batch operation)

Operating Manual -ENGLISH- Page 1 KWG-ISO

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

DCT7088 Portable Digital Correlation Transit Time Flowmeter

MINIMAT-EC. Handheld Screwdriver electric

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

5000V Digital/Analog Megohmmeter. Models 5050 & 5060

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

Refrigerated incubators with forced convection

Standard reference resistor Model CER6000

PTF 600. Six Drum Tablet Friability Test Instrument

OPT2015. High-performance distance sensor. Operating Instructions

High Performance Refrigerated Centrifuge Large number of tubes and capacity up to ml

IS-3000-LS-ABB INFRARED SCANNER

5000V Digital/Analog Megohmmeter Model 5060

Product catalogue. Sterile barrier systems. Indicator test systems. Sterilisation accessories. Hygiene accessories

Interface I-300 / I-300 Pro Technical data sheet

MInIMAT-Ec. flexible data recording highly accurate

SM9000. Magnetic-inductive flow meter. Made in Germany

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

PRODUCT INSTALLATATION PROCEDURE HX and HLX Thermal Transfer printing Guide. Table of Contents. Doc. No: Issue: 1 Date: October 2011

ulrich medical Tourniquets

VARIABLE SPEED DRIVES

CSB-Rack. Robust and reliable for automated online capture of data. Programmed for Your Success

DIAGNOSTICS PN# / / FSP

M-Series, MTBCM 01 FEATURES

PRO-1250D CT MID DIN rail three phase four wire energy meter.

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

VARIABLE SPEED DRIVES

optimail Postage meter Installation Guide

GxP-compliant Printing and Archiving of Initial Weights and Related Weighing Data. White Paper

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

EU Type Examination Certificate

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Thermal transfer printing systems

NovAseptic Valve, DIAPHRAGM, EPDM

4 MB Memory (upgradable to 10 MB) RS 232 Interface / RS 485 Interface SC Series

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0002 Revision 3

Universal High-Speed Benchtop Centrifuge Large Volume up to 4 x 1,000 ml

DPS SERIES DC POWER SUPPLIES

Brighten The World With

PX Series Balances. Quick Start Guide. Please download the user manual from

RoHS. High shaft load capacity. Shock / vibration resistant

Portable low-pressure controller Model CPC2000

C500 Series Data Sheet

Circuit Breaker Analyzer & Timer CAT65

2020 System Calibrator

minimat-ec Cordless screwdriver

DPST-5000M Digital Pitot Static Test Set

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

EC Type Examination Certificate

Compact Weighing Systems

EC Type-Approval Certificate

Micro Ohmmeter RMO200G

DRTS 66 can test all the following relays

Datasheet - SLB 200-C04-1R

Heratherm Compact Microbiological Incubators

Displays Transducers. Displays and transducers

Fusion of electronic pressure sensor and analogue display.

Transcription:

hm 3010/3020 DC-V/DC-VI Microprocessor-controlled rotary sealer with touch screen for sterile goods packaging (validatable process in accordance with ISO 11607)

hm 3010/3020 DC-V/DC-VI Microprocessor-controlled rotary sealer with touch screen for sterile goods packaging (validatable process in accordance with ISO 11607) Simple compliance with ISO 11607. Only those processes, which can be validated in accordance with ISO 11607 are approved for sealing sterile barrier systems. The hm 3010/3020 DC-V and hm 3010 DC-VI packaging devices achieve appropriately reproducible results, i.e. constant results at all times, as a result of installation, operational and performance qualifications. Furthermore, the standard requires continuous monitoring of the critical process parameters (temperature and contact pressure). In the event of deviations, a packaging device must automatically switch itself off and indicate the problem. A graph shown directly on the display ensures that the process is continuously documented by the hm 3010/3020 DC-V and hm 3010 DC-VI devices. For all of the information, which must be printed on the packaging (sterile barrier system), the devices have a microprocessor-controlled printer, which is available optionally either with a one-line (hm 3010) or two-line (hm 3020) print-out. hm 3010/3020 DC-V and hm 3010 DC-VI are suitable for sterile barrier systems in accordance with ISO 11607/EN 868, Tyvek 1059B, 1073B and 2FS. The touch screen of the hm 3010/3020 DC-V and hm 3010 DC-VI makes menu navigation and data input particularly simple; information can be quickly obtained via the color screen. hm 3010 DC-V/DC-VI with roll conveyor hm 500 RT

Validatable process in accordance with ISO 11607 Installation Qualification: The hm 3010/ 3020 DC-V/DC-VI series sealing devices are in accordance with ISO 11607. That means: the critical parameters are able to be documentated and recorded. Discrepancies in the parameters are to be indicated straight away. Accordingly it has to be anssured that the users are trained. Operational Qualification: Temperature and pressure have to be defined by the user in accordance with the material used. The parameters can be adjusted and adapted to the material individually with the hm 3010/3020 DC-V/DC-VI series devices. Performance Qualification: The resistance and integrity of the sealed seam have to be externally tested (e.g. in accordance with EN 868 paragraph D). The devices of the hm 3010/3020 DC-V/ DC-VI series can be connected directly to the testing device ht 150 SCD. Process Documentation: Possibility of mobile monitoring of the sealing parameters through a pocket PC and the hawo software hs 160 PTGo. Seal Ceck Function: Print-out of the sealing parameters on the back of the packaging. Graphical representation of the sealing parameters (temperature and contact pressure) to ensure 24 hour process control for 5 days. Data archiving for 5 days. Symbols in accordance with EN 980 for marking of packaging (for all devices) Product name Name or identification code of packing person. Choice of up to 10 preset items of personal data, password protected ID Batch number Use-by date (shelf life of sterile goods) with automatic update Packaging and sterilsation date Others Temperature and contact pressure CE mark with subsequent text Piece counter Text memory for 2500 alphanumeric texts Additional symbols for the device hm 3010 DC-VI Sterile symbol with the option of sterilization type: steam or dry heat, EO, irradiation symbol Refer to user instructions Not for reuse Microprocessor-controlled printing unit Printing of labels and texts also as barcode (Code 39, Code 128, Code 2/5-I) User definable data printing sequence Choice of five presettable print sequences Two-line printing (only with hm 3020) Setting of print start in mm from edge of packaging Variable type width and character spacing Print image rotatable 180 (inverted) Printer can be switched off Simple ribbon replacement from front of unit Functions Menu-driven operation and data input via color touch screen Serial RS 232 interface for connection to a PC and external printer hm 2000 C Connection to all available batch documentation systems Connection to hawo label printer hm 2000 C Connection of a bar code scanner for data entry (e.g. catalogue entries, personnel numbers, etc.) Programming independent of language Elapsed hour meter Clock and calendar function Programmable piece counter, with option of counting up or down, with a signal when preset value is reached (decreasing counter) Data storage and date extender even when device is switched off Selectable key lock Simple input and updating of data Stand-by function: the device goes into energy-saving stand-by mode after a predefined time (10-120 min) Service Automatic maintenance check: device notifies automatically if maintenance is necessary Quality management system in accordance with ISO 9001:2000 Calibration and validation service Simple and mobile process validation with the testing device ht 150 SCD Bar code printer hm 2000 C

Technical data hm 3010 DC-V/DC-VI hm 3020 DC-V Printing unit 1-line 2-line Printing start margin x continuously variable continuously variable in mm in mm Sealing speed 10 m/min. 10 m/min. Sealing margin infinitely variable y 5 30 mm (0.2 1.2 in) 5 30 mm (0.2 1.2 in) Sealing seam hawoflex sealing system s 12 mm (0.5 in) 12 mm (0.5 in) Safety distance sealing seam to packed goods (DIN 58593-7) A > 30 mm (1.2 in) > 30 mm (1.2 in) Temperature control Microprocessor Microprocessor Sealing temperature 80 220 C 80 220 C 176 428 F 176 428 F Temperature tolerance ± 2 % ± 2 % Power 500 VA 500 VA Mains connection 230 V / 50 Hz 230 V / 50 Hz 115 V / 60 Hz 115 V / 60 Hz Dimensions (w x d x h) 620 x 260 x 250 mm 740 x 260 x 250 mm (24.4 x 10.2 x 9.8 in) (29.1. x 10.2 x 9.8 in) Weight 23 kg (51 lb) 26 kg (57.2 lb) Accessories Roll conveyor hm 500 RT 830 x 280 x 60 mm 830 x 280 x 60 mm (32.7 x 11.0 x 2.4 in) (32.7 x 11.0 x 2.4 in) Storage tray hm 1000 T 850 x 280 x 60 mm 850 x 280 x 60 mm (33.5 x 11.0 x 2.4 in) (33.5 x 11.0 x 2.4 in) Bar code printer hm 2000 C 190 x 280 x 160 mm 190 x 280 x 160 mm (7.48 x 11.02 x 6.3 in) (7.48 x 11.02 x 6.3 in) x y s A hm 3010 DC-V/DC-VI: sterile goods bag with 1-line imprint and bar code hm 3020 DC-V: sterile goods bag with 2-line imprint and bar code Seal Check: The critical process parameter temperature and pressure are optimal; discrepancies are indicated by white the production of white bubbles

Continuous process checking (monitoring) and archiving of data over five days Clear touch screen with direct input function for print dates Integral keypad for simple data-input Symbols in compliance with EN 980 for marking the packaging Pre-programming of three selectable temperatures for different packaging types (e.g. packaging according to EN 868 and Tyvek)

Certified by Sealing devices and accessories for sterile goods packaging in clinics and the medical industry Testing systems for the inspectation and validation (Performance Qualification) of heat sealing processes Sealing devices and accessories for sterile goods packaging in dentists and the doctors surgeries Plastic film welding devices for industrial packaging Vacuum impulse sealers for industrial packaging Packaging machines for clothes and linen for laundries and dry cleaners Subject to technical alterations March 2006 / 9.344.039 / Printed in Germany 03/06 / 5.000 / wml / ST HAWO TQM-SYSTEM hawo GmbH Obere Au 2-4 74847 Obrigheim / Germany T +49 (0) 6261 9770-0 F +49 (0) 6261 9770-69 info@hawo.com www.hawo.com Design und Konzept www.wolfmedialounge.de