Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

Similar documents
Insulated Enclosure KO 4730 with twin-level box terminal for plug-in technology

Insulated Enclosure KO 4733 with twin-level box terminal for plug-in technology

Insulated Enclosure KO 4763 with box terminals for solder or plug-in technology

Insulated Enclosure KU 4087, KU 4088 KU 4089 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KU 4091 to DIN for installation in distribution cabinets or surface mounting

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

In-Rail-Bus Bus system in DIN-rail

Altech s DIN Enclosures by

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Switches and Indicators 84

Installation / Control Technique

Probably the fastest enclosure in the world

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

IDG-B Enclosures for Industrial and Building Automation Controls.

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control / Monitoring Technique

ALPHA SIMBOX Small Distribution Boards

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Power Electronics. Semiconductor relay / - contactor

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Pan assemblies and installation accessories

IT power distribution Power distribution units (PDU) Basic. Versions available:

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

Multitronic. Technical data

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

AMIGO-Distribution Boards for flush mounting

XL 4000 metal free-standing enclosures and cable compartments

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

PERFECTLY COMBINED YOUR ADVANTAGES. Suitable for DIN rails EN TH35 or direct

- 1 - General ordering data Order No

Zelio Relay - plug-in relays

Data sheet... OMNIMATE Power - series BL/SL 7.62HP BLZ 7.62HP/04/180LR SN BK BX

PHOENIX CONTACT - 05/2007

Faults on the system Proximity switch connection technology:

DIN Rail Mounted Terminals & Accessories

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

PHOENIX CONTACT - 01/2008

Thermal-Magnetic Circuit Breaker 2216-S

Item No.: /

ODU MAC LC. Modular Attachable Connector System

10. EMC accessories. Chapter. EMC shield rails and accessories 10.3 EMC shield clamps and accessories 10.7 Earthing strips Cable clips 10.

SUNCLIX Connection technology for photovoltaics

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

WINSTA. Full Line Catalog 2008/2009

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

UTME 6. Extract from the online catalog. Order No.:

Technical data: Pin Spacing

Electrical Interconnection

- 1 - General ordering data Order No

Power distribution systems - accessories

RM84 miniature relays

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Extract from the online catalog

TEMPERATURE RATINGS: Terminal Housing: 290 C (554 F) UL94VO Housing: 115 C (239 F) UL94VO

Module 18plus. Description. 18plus

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

SUBMINIATURE MICROSWITCHES - SEALED

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

UK 5-HESILA 250. Extract from the online catalog. Order No.:

Ripac VME/VME64x Systems. Applications. Design Features

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

2 PIECE BOARD-TO-BOARD

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

High-density multi-pin connectors

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Limanda. Technical data

Taguan 130. Technical data

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

Power Supply HARTING pcon

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

5 Fieldbus Technology

Extract from the online catalog

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

EC-E1 10A. Extract from the online catalog. Order No.: Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 10 A

Electrical Connection Technology. New Items: Autumn 2007

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

LUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, ring nut fixing LUMOTAST 25 keylock switch 1-30 LUMOTAST 25 keylock switch 1-31

MODULES FOR SAFETY AND MONITORING

Extract from the online catalog

Power Supply HARTING pcon

- 1 - General ordering data Order No

Rack Installation Instructions

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

8WH5 Combination Plug-In Terminals

for a perfect electrical installation. The range of rail-mounted terminal blocks

Transcription:

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614 0063988 0064140 0064142 Width [mm]: 12. 17. 22. 3.0 4.0 67. 90.0 Height / Depth [mm]: 107 / 120 * ) Standard enclosure, comprising: Enclosure casings left/right; or. separator plate; front plate; mounting clip KS 4401 KS 4402 KS 4403 Enclosure material: Front plate material: Terminals: PA-GF, black RAL 9011, light grey RAL703 other colours on request PBT; light grey RAL703, yellow RAL1021, red RAL3000, blue RAL01, black RAL900 other colours on request PA, black RAL900, light grey RAL703 other colours on request KS 4461 KS 4404 Temperature stability PA-GF, PA PBT complying with UL 746 B: 120 C 120 C complying with Vicat ISO 306 Meth. B: 230 C 14 C compl. with ISO 7-2 Meth. A: Meth. B: 22 C 23 C 8 C 13 C Specific thermal resistance: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 without ventilation slots individual module [K/W]: 16.8 1. 13. 11.8 10.0 7.2.2 20 mm distance [K/W]: 7.6 7.3 6.8 6.2.6 4.6 3.7 100 mm distance [K/W]: 6. 6.1..0 4. 3.9 3. KS 440 with ventilation slots individual module [K/W]: 1. 12. 9.3 7.6 6.0 3.7 2.3 20 mm distance [K/W]: 7.2.9 4.7 4.0 3. 2.7 1.9 100 mm distance [K/W]: 6.2.1 4.1 3.7 3.2 2. 1.8 Flame retardancy PA PBT complying with UL 94: V-0 V-0 Number of terminals: KS 4401 KS 4402 KS 4403 KS4461 KS 4404 KS 440 KS 4406 max. 12 max. 18 max. 24 max. 36 max. 48 max. 72 max. 96 KS 4406 Your advantage modular, flexible, innovative large front print area and large pcb areas provide more space for your ideas maximimum space utilisation various connection technologies distinctive design for automated and cost effective assembly customisation to customer requirements Features Width 12. / 17. / 22. / 3 / 4 / 67. / 90 mm max. terminals 12 / 18 / 24 / 36 / 48 / 72 / 96 at 2, mm 2 cross section up to 30 terminals on three levels, per 22. mm module width. optional in-rail-bus system for quick and reliable data and energy transfer Max. cross section for connection: see Product Overview GE02 "Terminals" Insul. of wires or sleeve length: 7 mm Fixing torque: 0. Nm Wire fastening: captive slotted screw M2. Max. contact resistance to printed circuit board: 10 mw Insulation coordination / UL Data: see Product Overview GE02 "Terminals" Inner connection: Terminal block can be machine soldered Enclosure mounting: Snap-on clip on top hat rail IEC/EN 60 71 Creepage resistance: Insulation Insulation PLC CTI type group classification Enclosure: PA 0 II 1 PBT 22 III a 3 Terminals PA 600 I 0 Air gap and creepage distance: 4 mm IEC 60 664-1 Degree of protection Enclosure: IP 40 (without ventilation slots) IEC 60 29 IP 30 (with ventilation slots) IEC 60 29 Terminals: IP 20 IEC 60 29 contact protection complies with VBG 4 All specifications correspond to the technology used at time of publication. We reserve the right to make improvements and changes of a technical naturre at any time. 1

Example print area Technical Data } } 19,6 9, 62 9, Klemmebene Terminal level 3 Klemmebene Terminal level 2 Terminal Klemmebene level 1 Klemmebene Terminal level 2 Klemmebene Terminal level 3 Area 62 x 19,6 usable for various cutouts or printings Print area Front plate KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Width [mm]: 9,6 14,6 19,6 32,0 42,0 64, 87,0 Height [mm]: 81,8 Printed circuit board: Printed circuit board holder: See printed circuit board design bracket ribs Net weight KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Weight [g]: 7 62 70 83 2) 96 2) 122 3) 148 4) Enclosure casings with standard front plate and mounting clip 2) Enclosure casings with separator plate, standard front plate and mounting clip 3) Enclosure casings, 2 x separator plate, standard front plate, 2 x mounting clip 4) Enclosure casings, 3 x separator plate, standard front plate, 2 x mounting clip Optional: Area 9, x 19,6 usable for terminal assignment. Accessories and furhter options blanking plug 1,6,8 M440_a KS4403--1: KS4400-7-1: KS4400-6-1: KS4400-8-1: Blanking plug, black or light grey, to cover unused terminals lighting conductor, 3 mm grid, lighting conductor, mm grid various lengths, on request Test button, black, on request Enclosures with earthing spring to the DIN-Rail 3,0 0,6 M411_a 40,8 M410_a 36,7 Enclosure with hinged transparent plate Enclosures with curved, transparent, front cover Further options: - BUS compatible enclosure variants for use with DOLD s In-Rail-Bus-System - As option with ventilation slots - Other connections on request 2

Dimensions standard enclosure KS 4401 - KS 4404 (IP 40) 2, *) 6,0 DINEN 6071 +0, 12, - 0 2,*) 11,0 Tophat rail DINEN6071 +0, 17, - 0 2,*) 16,0 DINEN 6071 +0,6 22, - 0 M4279_a M4279_a M42_a M42_a M4239_b M4239_b 3 3 3 *) 3,0 with printedcircuit board thickness t = 1 mm *) 3,0 with printed circuitboard thickness t=1mm *) 3,0 with printed circuit board thickness t = 1 mm KS 4401 KS 4402 KS 4403 2,*) 16 11,0 2,*) 24, 2,*) Tophat rail DINEN6071 3-0 M442_a M442_a M442_a 3 *) 3,0 with printed circuitboard thickness t=1mm KS 4461 2,*) 21 16,0 34, 2,*) 2,*) DINEN 6071 4-0 A 122,6-0 11,3-0 M4311_a M4241_c M4241_c 3 106,9 109 1 M4310_a A *) 3,0 with printed circuit board thickness t = 1 mm KS 4404 3

Dimensions standard enclosure KS 440 - KS 4406 (IP 40) 2,*) 21 21 16,0 DINEN 6071 +0,8 67, - 0 M433_a M433_a 3 KS 440 *) 3,0 withprintedcircuit board thickness t = 1 mm 2,*) 21 21 21 16,0 DINEN 6071 +1 90-0 A 122,6-0 11,3-0 M4337_a M4337_a 3 106,9 109 1 M4310_a A KS 4406 *) 3,0 withprinted circuit board thickness t = 1 mm Enclosure with ventilation slots (IP 30) M4191_b M4332_a KS 4403 KS 4404 4

Printed circuit board design for fixed 2-pole terminals (pcb terminals) 3x Terminal left KS4400-21 12x + 1,4 0,1 98,7 96,7 91 78,48 13,1 6, 3,7 10 3x Terminal right KS4400-20 M4324_a 78, 6,7 3 27,3,6 17,1 R1,0 t= 2,44 74,21 9,97 10, 96 + 0,2 96,3,9 9 non dimensioned radii max. R1 tolerance to DINEN 60249-2-4 General tolerance:perfag 2E KS 4401 Printed circuit board design for pluggable 2-pole terminals 12x 1,4 +0,1 3x connection strip left KS4400-23,9 80,3 79,6 78,8 67,2 6, 3,9 3,4 4,1 6x Terminal KS4400-24 3x connection strip right KS4400-22 M4321_a 11 20 91,3 84,1 69,6 62,3 47,8 27,3,6 R1,0 t= 3 80,14 8,38 101,9 96-0,2 96,3 9 non dimensionedradii max. R1 tolerancetodin EN 60249-2-4 General tolerance: PERFAG 2E KS 4401

Printed circuit board design for fixed 3-pole terminals (pcb terminals) 3x Terminal left KS4400-31 18x 1,4 98,7 96,7 91 78,48 13,1 6, 3,7 10 3x Terminal right KS4400-30 M4330_a 78, 6,7 3 27,3,6 17,1 R1,0 2x=10 t= 2,44 74,21 9,97 10, 96 + 0,2 96,3,9 9 nondimensioned radii max. R1 tolerance to DINEN 60249-2-4 General tolerance: PERFAG 2E KS 4402 Printed circuit board design for pluggable 3-pole terminals 18x 1,4 +0,1 3x connection strip left KS4400-33,9 80,3 79,6 78,8 67,2 6, 3,9 3,4 4,1 6x Terminal KS4400-34 3x connection strip right KS4400-32 M4327_a 91,3 84,1 69,6 62,3 47,8 11 27,3,6 R1,0 2x=10 t= 20 3 80,14 8,38 101,9 96-0,2 96,3 9 non dimensioned radii max. R1 tolerance to DINEN 60249-2-4 General tolerance:perfag 2E KS 4461, KS 4402 6

Printed circuit board design for fixed 4-pole terminals (pcb terminals) 98,7 96,7 3x Terminal left KS4400-41 24x 1,4 +0,1 91 66,17 18,2 1,6 6,4 3,7 10 3x Terminal right KS4400-40 M424_b 78, 6,7 3 27,3,6 17,1 R1,0 96 + 0,2 96,3,9 3x=1 t= 44,6 66,33 88,09 10, 9 non dimensionedradii max. R1 tolerance to DINEN 60249-2-4 General tolerance: PERFAG2E KS 4403, KS 4404, KS 440, KS 4406 Printed circuit board design for pluggable 4-pole terminals 24x 1,4 +0,1 3x connection strip left KS4400-43,9 80,3 79,6 78,8,2 1,6 4,9 3,4 3 6x Terminal KS4400-44 3x connection strip right KS4400-42 M4243_b 11 91,3 84,1 69,6 62,3 47,8 27,3,6 R1,0 3x=1 t= 3 0, 72,26 94,02 +0 +0 96-0,2 96,3 9 nondimensioned radii max. R1 tolerance to DIN EN 60249-2-4 Generaltolerance:PERFAG 2E KS 4403, KS 4404, KS 440, KS 4406 7

Notes on housing assembly Assembly of enclosure 1. With terminals fitted, place the pcb in the first enclosure casing. 2. Slide the front plate in the slot in the first enclosure casing. 3. Place the first enclosure casing flat and line-up the second casing so that the front plate slides into the slot. 4. Manually close both casings until they snap together.. Insert the DIN-rail mounting clip into the base of the enclosure. Notes on housing disassembly Disassembly of terminals 1. Place screwdriver in the gap between the terminals 2. Pull the screwdriver downwards Disassembly of enclosure 1. With a screwdriver, lift up the plastic spring of the mounting clip. 1.1 Use the screwdriver to lever off the clip. 2.1 Place the screwdriver in the slot located on the DIN-rail hanger. 2.2 Rotate the screwdriver to loosen the first snap connection. 3.1 Place the screwdriver in the slot located near the clip position. 3.2 Rotate the screwdriver to loosen all other snap connections 4. Manually part the enclosure casings. E. DOLD & SÖHNE KG D-78114 Furtwangen e-mail: GV-Vertrieb@dold.com internet: http://www.dold.com PO Box 121 Telephone (+49) 77 23 / 64-0 Telefax (+49) 77 23 / 64-36 8