Data Center NJ1 Piscataway, NJ
powerful/ efficient /reliable solutions >
Data Center NJ1 ABOUT DUPONT FABROS TECHOLOGY (DFT) DFT is a leading owner, developer, operator and manager of wholesale data centers. Our highly advanced and secure facilities power, cool, and protect the computer servers of numerous enterprise and technology companies. In conjunction with our operational expertise, we deliver uninterrupted service and ultimate reliability to our customers mission critical business applications. OVERVIEW One of the largest, most sophisticated and efficient data centers available in the Greater Metro New York Area, NJ1 will bring a new class of data center to the market. Located in Piscataway, New Jersey and designed to LEED Standards, NJ1 will be built in two identical Phases, each comprising 18.2 MW of Critical Load. With its flexible and efficient design, customers are able to lease one or multiple dedicated computer rooms each with independent redundancy and security. Should a tenant's requirement increase, our scalable solution enables them to take additional space as needed. The facility has multiple major fiber carriers on site and will benefit from the area's most competitive power rates. PHILOSOPHY Committed to ultimate reliability, DFT s philosophy is to design, build, operate and manage highly dependable and environmentally efficient data centers. Our goal is to maximize Power Usage Effectiveness ("PUE") in all aspects of data center operations. Dynamic electrical distribution and flexible floor plans provide optimal solutions for our tenants. DFT commissions proven technologies, such as rotary UPS and evaporative chilled water systems, in configurations that maximize utilization of the data center design and infrastructure. Our engineering track record and expertise enable us to shorten the duration of construction and minimize costs which directly benefit our tenants. >
Data Center NJ1: Specifications Location: Piscataway, NJ Acreage: 38 Building Size: 360,000 sq ft Nearest Airport: Newark Liberty International Airport PROPERTY BUILDING DESCRIPTION ROOM SPECIFICATIONS DATA CENTER AREA DESCRIPTION STAGING/TENANT OFFICE SPACE SECURITY Utility Power: 26.4 kv Parking: 200+ Number of Stories: 1 plus Mezzanine Loading Docks: 4 Dock Bays Rooms 1-6, 11-16: Critical Load: 2.275 MW Approx. Gross SF: 11,000 Rooms 7A-10D: Critical Load: 0.56875 MW Approx. Gross SF: 2,700 Raised Floor Area: 176,200 sq ft Raised Floor Height: 42 under raised floor plenums Raised Floor to Ceiling Height: 15-22 ft Office: 12 private suites Staging: multiple staging rooms Building: Ballistic glass enclosed security check-in, front window areas and loading dock Perimeter: Security fence surrounds entire land area/building with guard house Security Guards: Staffed 24/7 Access Control: Electronic Security features with card key access and dual authentication with biometric readers CCTV: 24/7 surveillance of the interior/exterior of the facility Total Megawatts: 36.4 CRITICAL POWER UPS SYSTEMS GENERATORS ON SITE FUEL CAPACITY HEAT REJECTION SYSTEMS (HVAC) PDUS COMMUNICATIONS Description: 32 Rotary power systems with 1,300 kw of critical output each Redundancy: N+2, Each Phase Description: 32 diesel-powered engine generators with 2,250 kw capacity each Redundancy: N+2, Each Phase Storage Tanks: Four 50,000 gallon underground diesel storage tanks Number of Hours: Nominal 55 Hours Description: 16 centrifugal chillers with 1,080 Ton capacity each Storage Tanks: Two 500,000 gallon above ground chilled water storage tanks Redundancy: N+2, Each Phase Description: Dual Input 300 kva PDUs - 600 volt primary POE: 4 separate network Points of Entry (POE) with diverse underground duct banks providing multiple entry points into the facility Conduits: Dedicated underground conduits to each computer room Multiple Carriers: Available Meet-Me-Room: Available Description: Conventional smoke detector and laser based incipient smoke detection systems and double interlocked pre-action sprinkler system FIRE PROTECTION >
Data Center NJ1: Map CENTRIFUGAL CHILLER (TYP.) CORRIDOR 4 ROOMS 1-6 28 TON CRAH (TYP.) MECHANICAL ROOM 1 MECHANICAL ROOM 2 BLR. RM. 1 CORRIDOR 3 BLR. RM. 2 CORRIDOR 8 ROOMS 11-16 CORRIDOR 9 ROOMS CORRIDOR 6 CORRIDOR 7 ROOMS 1 2 3 4 5 6 11 12 13 14 15 16 SWITCHGEAR (TYP.) 7B 7D 8B 8D 9B 9D 10B 10D CORRIDOR 5 UPS 1-8 UPS 9-16 CORRIDOR 2 7A 7C 8A 8C 9A 9C 10A 10C CORRIDOR 2 POE 1 POE 4 POE 3 NOC/FAC. ELEV. CNTRL. RM. POE 2 MR. TC. MEET RM. 1 9 10 2 3 4 5 6 7 8 W. OFF. 11 12 13 14 15 16 SPK. SHOP/STORAGE FACILITIES TEN. 4 TEN. 3 CORRIDOR 1 M. TEN. 2 DOCK TEN. 1 LOB. CON. TEN. 5 SEC. 10 CON. OFF SWITCHBOARD (TYP.) EG 1-8 STOR. MECH. RM. MECH. RM. MER. RM. STOR. DIESEL ENGINE GENERATOR (TYP.) EG 9-16 1 2 3 4 5 6 7 8 ELEV. CR. PRTS. 9 10 11 12 13 14 15 16 LOU. TEN. 213 TEN. 212 TEN. 201 TE/EL TEN. 203 W. STOR. TEN. 211 TEN. 209 MEZZANINE FLOOR M. TEN. 210 TEN. 208 TEN. 204 BR. RM. TEN. 207 TEN. 206 TEN. 205 SPACE ALLOCATIONS PHASE 1 PHASE 2 Electrical/Mechanical Computer Room Public Circulation Data/Telco Support Administration/Office MV. 2 T. S. T.
For more information please contact leasing@dft.com 1212 New York Ave., NW Suite 900 Washington, DC 20005 P 202.728.0044 F 202.728.0220 www.dft.com NYSE: DFT