S7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;

Similar documents
Short Description. Version

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC S7-200 PRICE LIST

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

General information. Supply voltage. Input current


CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

SIMATIC WinAC - PROFINET/ Ethernet PROFIBUS. Windows. Time Synchronization. MATIC NET SOFTNET-S7 Lean SIMATIC NET OPC -

General information. Supply voltage. Input current

ET 200S Motor Starters and Safety Motor Starters

General information. Supply voltage. Input current

General information. Supply voltage. Input current

SIMATIC S Central processing units


WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Engineered with TIA Portal SIMATIC S Itʼs the interplay that makes the difference. siemens.com/s Answers for industry.

BẢNG GIÁ PLC SIEMENS S7-200 Áp dụng từ 01/11/ Giá chưa bao gồm thuế VAT

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

Supplier s declaration of conformity

Application on Communication

Supported modules System 300S Version:

SIMATIC S PRICE LIST

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

Product type designation. General information. Supply voltage

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

SIMATIC PC-based controller

SIMATIC. Process Control System PCS 7 Released modules (V8.0) ET 200M 1. Gateway 2 ET 200S 3. ET 200iSP 4 ET 200S 5 ET 200X 6.

1 What's new in SIMATIC imap STEP 7 AddOn?

Supplementary Components Network transitions

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

Product Information on the Manual

SIMATIC. Process Control System PCS 7 Released Modules (V8.0 SP2) ET 200M 1. Gateway 2 ET 200S 3. ET 200iSP 4 ET 200S 5 ET 200X 6.

SIMATIC. Process Control System PCS 7 Released Modules (V8.0 SP2) Security information 1 ET 200M 2. Gateway 3 ET 200S 4. ET 200iSP 5 ET 200S 6

SIMOTION P PC-based SIMOTION P350-3

Application for Process Automation

CPU 412H. Function. Parameterizable properties

SIMATIC S plus TIA Portal

Engineered with TIA Portal. Be flexible thanks to networking possibilities. Basic Controller SIMATIC S siemens.com/s7-1200

CPU 412. Function. Programmable properties

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

Distributed I/Os SIMATIC ET 200

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

VIPA System 300S - The High-Speed control system

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

SIMATIC. Process Control System PCS 7 Released modules (V8.2) Security information 1 ET 200M 2. Gateway 3 ET 200PA SMART 4 ET 200S 5.

Distributed I/O SIMATIC ET 200

SIMATIC PCS 7 Standard Architectures

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

General information. Display. Control elements. Supply voltage

Data sheet CPU 315SN/PN ECO (315-4PN33)

General information. Configuration control. Display. Control elements. Supply voltage

General information. Supply voltage

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

1 What's new in SIMATIC imap STEP 7 AddOn?

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Product type designation. General information. Supply voltage

Product type designation

Data sheet CPU 015PN (015-CEFPR01)

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

SIMATIC. Windows Automation Center RTX WinAC RTX Introduction 1. Product overview 2. Installation 3. Getting started 4

Certificate Z SIMATIC S7 Distributed Safety

TIM DNP3 SIMATIC NET. Industrial Remote Communication - Telecontrol TIM DNP3. Preface. Uses and properties of the TIM

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 015PN (015-CEFPR00)

Data sheet SLIO CPU 015PN (015-CEFPR01)

CP ADVANCED. Function

Certificate Z SIMATIC S7 Distributed Safety

Product type designation. General information. Supply voltage. Input current. Power losses

SIMATIC. Distributed I/O System Fail-Safe Engineering ET 200S Distributed I/O System - Fail-Safe Modules. Preface. Product Overview 1.

System Description SIMATIC. PROFINET System Description. Preface. Guide to the PROFINET Documentation. PROFINET overview 2. Setting Up PROFINET 3

2. CPU PID PLC SIMATIC-CPU. CPUxT-2 DP MICROBOX 420-T S7-300 PLC. SIMATIC Microbox STEP7 SIMATIC PLC T-CPU. SIMATIC PLC Technology.

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

FAQ 12/2015. PROFINET IO Communication.

IE/PB LINK PN IO. PROFINET applications

Compact PLC for STEP7 from Siemens PLC-CPU for STEP7 from Siemens Order no. Type VIPA 214-1BA02 CPU 214 VIPA 214-1BC02 CPU 214C VIPA 215-1BA02

General information. Supply voltage

CPU 410-5H Process Automation SIMATIC. PCS 7 process control system CPU 410-5H Process Automation. Preface 1. Introduction to CPU 410-5H

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

SIMATIC PCS 7 Outlook

Laboratory automation

SIPLUS CPU 313C-2DP. Function

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

S7-400 Automation System, CPU Specifications. S7-400 Automation System, CPU Specifications. Manual. Manual SIMATIC S Answers for industry.

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN

Product type designation. General information. Supply voltage. Input current. Power loss

Distributed Control I/O System ADAM-8000 Series

Data sheet VIPA CPU M13C (M13-CCF0000)

Transcription:

S7-400 CPU 412-1 6ES7 412-1XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; 0.075 ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI; send and receive capability for direct data exchange; DP constant bus cycle time and clocking editing; routing; data record routing; multicomputing CPU 412-2 DP 6ES7 412-2XJ05-0AB0 V5.2 Work memory 256KB code and 256KB of data; 0.075 ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; data record routing; multi-computing CPU 414-2 DP 6ES7 414-2XK05-0AB0 V5.2 Work memory 512KB code and 512KB data 0.045 ms/1000 instructions; 8KB DI/O; 32 connections 1*DP/MPI and 1*DP; send receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; data record routing; multi-computing CPU 414-3 DP 6ES7 414-3XM05-0AB0 V5.2 Work memory 1.4MB code and 1.4MB of data 0.045 ms/1000 instructions 8KB DI/O; 32 connections 1*DP/MPI, 1*DP and 1 receptacle for IF modules; send and receive capability for direct data exchange; constant bus cycle time and clocking editing, routing, data record routing; mulitcomputing CPU 416-2 DP 6ES7 416-2XN05-0AB0 V5.2 Work memory 2.8MB code and 2.8MB data 0.030 ms/1000 instructions; 16KB DI/O; 64 connections 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; data record routing; multicomputing capability; firmware V5.2 CPU 416F-2 6ES7 416-2FN05-0AB0 V5.2 Work memory 2.8MB code and 2.8MB data 0.030 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; data record routing; multicomputing; firmware V5.2; can be used for safety applications; supports PROFIsafe V2 CPU 416-3 DP 6ES7 416-3XR05-0AB0 V5.2 Work memory 5.6MB code and 5.6MB of data 0.030 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI, 1*DP and 1 receptacle for IF modules; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; data record routing; multicomputing CPU 417-4 6ES7 417-4XT05-0AB0 V5.2 Work memory 15MB code and 15MB of data; 0.018 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 receptacles for IF modules; multi-computing computable, send and receive capable for direct data exchange, constant bus cycle time and clocking editing, routing, data record routing; firmware V5.2 CPU 414-3 PN/DP 6ES7 414-3EM05-0AB0 V5.3 Work memory 1.4 MB code and 1.4 MB data; 0.045 ms/1000 instructions; 8 KB DI/O; 32 connections; 1*DP/MPI, ports; PROFINET CBA; PROFINET CBA Proxy; firmware V5.3 CPU 416-3 PN/DP 6ES7 416-3ER05-0AB0 V5.3 Work memory 5.6 MB code and 5.6 MB data; 0.030 ms/1000 instructions; 16 KB DI/O; 64 connections; 1*DP/MPI, ports; PROFINET CBA; PROFINET CBA Proxy; firmware V5.3 CPU 416F-3 PN/DP 6ES7 416-3FR05-0AB0 V5.3 Work memory 5.6 MB code and 5.6 MB data; 0.030 ms/100 instructions; 16 KB DI/O; 64 connections; 1*DP/MPI, ports; PROFINET CBA; PROFINET CBA Proxy; firmware V5.3. Can be used for security applications; supports PROFIsafe V2 1

S7-300 CPU 319-3 PN/DP 6ES7 318-3EL00-0AB0 V2.8 Work memory 1400KB; 0.01ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multiline structure up to 32 modules; constant DP bus cycle time; routing; data record routing; firmware V2.8 CPU 319F-3 PN/DP 6ES7 318-3FL00-0AB0 V2.8 Work memory 1400KB; 0.01ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multiline structure up to 32 modules; constant DP bus cycle time; routing; data record routing; firmware V2.8, can be used for safety applications; supports PROFIsafe V2 IE/PB Link 6GK1 411-5AB00 V2.1 IE/PB Link (configuration as gateway), connects Industrial Ethernet with PROFIBUS, routing, data record gateway, S7 slaves, DPV1 slaves, firmware V2.1 SM 331 AI6xTC 6ES7 331-7PE10-0AB0 Analog input module AI6xTC, 16bits, iso; Thermocouples: B, E, J, K, L, N, R, S, T, U, C, TXK/XK(L); Firmware update CP 341-RS232C 6ES7 341-1AH02-0AE0 Communication processor with connection: RS232C (RK512, ASCII, 3964(R), printer, loadable driver) CP 341-20mA TTY 6ES7 341-1BH02-0AE0 Communication processor with connection: 20 ma TTY (RK512, ASCII, 3964(R), printer, loadable driver) CP 341-RS422/485 6ES7 341-1CH02-0AE0 Communication processor with connection: RS422/485 (RK512, ASCII, 3964(R), printer, loadable driver) SM 335 AI4/AO4x14/12Bit 6ES7 335-7HG02-0AB0 Analog I/O module AI4/14 bits + AO4/12 bits FM350-2 COUNTER 6ES7 350-2AH01-0AE0 Counter module, 8 channels FM350-2 COUNTER E 6ES7 350-2AH01-0AE0 Counter module, 8 channels, extended user data 2

PC Station WinLC RTX EC 6ES7 677-1DD00-0BA0 V1.0 CPU for S7-mEC with Logic Controller functions WinLC RTX V4.4; PROFINET IO controller, supports RT/IRT, PROFINET CBA, TCP/IP transport protocol, S7 communication, multi-line structure of up to 32 modules; Firmware V1.0 WinLC RTX 6ES7 611-4SB00-0YB7 V4.4 WinLC RTX V4.4 (for WinAC RTX 2008, 6ES7 671-0RC06-0YA0); Software Logic Controller for Windows XP with Ardence RTX Realtime environment V8.1; DP connection (DP master); DPV1 with constant bus cycle time and isochronous mode; PROFINET connection; PROFINET IO-Controller; supports RT/IRT; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; Routing; S7 communication; firmware V4.4 CP 5711 6GK1 571-1AA00 V7.1.1 SIMATIC NET CP 5711 PROFIBUS, S7 connections, DP master, DPV1, DP slave, PG functions, routing, DP master class 2, USB, SIMATIC NET CD 2008 SP1 CP 5623 6GK1 562-3AA00 V7.1.2 SIMATIC NET CP 5603 PROFIBUS, S7 connections, FMS connections, DP master, DP slave, DPV1, direct data exchange, constant bus cycle time, PG functions, routing, PCI-E Bus, SIMATIC NET CD 2008 SP 2 CP 5624 6GK1 562-4AA00 V7.1.2 SIMATIC NET CP 5624 PROFIBUS, S7 connections, FMS connections, DP master, DPV1, direct data exchange, constant bus cycle time, PG functions, routing, DP master class 2, PCI-E Bus, SIMATIC NET CD 2008 SP 2 CP 1623 6GK1 162-3AA00 V7.1 SIMATIC NET CP 1613 Industrial Ethernet, ISO, TCP/IP, S7 connections, H communication, TCP connections, PG functions, PCI bus, routing, 2GBit ports, SIMATIC NET CD 2008 CP 1616 6GK1 161-6AA00 V2.3 SIMATIC NET CP 1616 Industrial Ethernet, PROFINET IO-Controller, IO-Router, MRP, prioritized startup, Firmware V2.3 CP 1616 onboard 6GK1 161-6AA00 V2.3 SIMATIC NET CP 1616 Industrial Ethernet, PROFINET IO controller, IO router, isochronous real-time Ethernet, prioritized startup, firmware V2.3 CP 1613 6GK1 161-3AA00 V7.1 SIMATIC NET CP 1613 Industrial Ethernet, ISO, TCP/IP, S7 connections, H communication, TCP connections, PG functions, PCI bus, routing, SIMATIC NET CD 2008 CP 5613 A2 6GK1 561-3AA01 V7.1.2 SIMATIC NET CP 5613 A2 PROFIBUS, S7 connections, FMS connections, DP master, DP slave, DPV1, direct data exchange, constant bus cycle time, PG functions, routing, DP master class 2, PCI Bus, SIMATIC NET CD 2008 SP 2 CP 1612 6GK1 161-2AA00 V7.1 SIMATIC NET CP 1612 Industrial Ethernet, ISO, TCP/IP, S7 connections, PG functions, PCI bus, routing, PROFINET IO Controller, prioritized startup, SIMATIC NET CD 2008 IE General IE_CP V7.1 Substitute for any Industrial Ethernet module, ISO, TCP/IP, S7 connections, PG functions, routing, PROFINET IO Controller, prioritized startup, SIMATIC NET 2008 3

PROFIBUS-DP IM151-1 Standard 6ES7 151-1AA05-0AB0 Interface module IM151-1 for ET 200S electronic modules, option handling with/without standby modules, 240 bytes of parameters per slot PROFINET-IO ET 200pro IM154-4 PN HF Cu V6.0 6ES7 154-4AB10-0AB0 V6.0 PROFINET IO device interface submodule IM 154-4 PN with copper cable design for ET 200pro electronic modules, supports packing; PROFINET interface and 2 ports; FW update via bus; port diagnostic; I&M functions; IRT and prioritized startup; firmware V6.0 ET 200pro IM154-6 PN HF IWLAN V1.0 6ES7 154-6AB00-0AB0 V1.0 PROFINET IO device interface module IM 154-6 PN HF with radio interface for ET 200pro electronic modules, supports packing; PROFINET interface for industrial WLAN; FW Update via MMC; I&M functionality; firmware V1.0 ET 200M IM153-4 PN V2.0 6ES7 153-4AA01-0XB0 V2.0 PROFINET IO device interface submodule IM 153-4 PN (ERTEC200) for S7-300 SMs, FM 350 to FM 352, FM 357, CP 340, CP341, CP343-2, PROFINET interface and 2 ports, FW update via bus, port diagnostics, I&M functions; IRT and prioritized startup; firmware V2.0 PN-PN-Coupler-V20 6ES7 158-3AD01-0XA0 V2.0 Coupler of two PROFINET networks, IP20; PROFINET interface and 2 ports; X2 (right side); FW Update via bus; port diagnostics; I&M functionality; IRT and prioritized startup; firmware V2.0 ET 200S IM151-3 PN ST V6.1 6ES7 151-3AA23-0AB0 V6.1 PROFINET IO device interface module IM 151-3 PN ST (ERTEC200) for ET 200S electronic module, supports packing; PROFINET interface and 2 ports; FW Update via bus; port diagnostics; I&M functionality; IRT and prioritized startup; firmware V6.1 ET 200S IM151-3 PN HF V6.1 6ES7 151-3BA23-0AB0 V6.1 PROFINET IO device interface module IM 151-3 PN HF (ERTEC200) for ET 200S electronic module, supports packing; PROFINET interface and 2 ports; FW Update via bus; port diagnostics; I&M functionality; IRT and prioritized startup; firmware V6.1 ET 200S IM151-3 PN FO V6.1 6ES7 151-3BB23-0AB0 V6.1 PROFINET IO device interface module IM 151-3 PN FO (ERTEC200) for ET 200S electronic module, supports packing; PROFINET interface and 2 ports; FW Update via bus; port diagnostics; I&M functionality; firmware V6.1 ET 200S IM151-3 PN HS V2.1 6ES7 151-3BA60-0AB0 V2.1 PROFINET IO device interface submodule IM 151-3 PN HS (ERTEC200) for ET200S electronic modules; PROFINET interface and 2 ports; FW update via bus; port diagnostics, supports isochrone mode; I&M functions; IRT and prioritized startup; firmware V2.1 ET200ecoPN 8 DO DC24V/1.3A 8xM12 V6.0 6ES7 142-6BG00-0AB0 V6.0 PROFINET IO compact device; 8 DO DC24V/1.3A 8xM12; 60mm overall width; PROFINET interface and 2 ports; ET200ecoPN 8 DI DC24V 8xM12 V6.0 6ES7 141-6BG00-0AB0 V6.0 PROFINET IO compact device; 8 DI DC24V 8xM12; 60mm overall width; PROFINET interface and 2 ports; ET200ecoPN 16 DI DC24V 8xM12 V6.0 6ES7 141-6BH00-0AB0 V6.0 PROFINET IO compact device; 16 DI DC24V 8xM12; 60mm overall width; PROFINET interface and 2 ports; ET200ecoPN 8 DO DC24V/0.5A 4xM12 V6.0 6ES7 142-6BF50-0AB0 V6.0 PROFINET IO compact device; 8 DO DC24V/0.5A 4xM12; 30mm overall width; PROFINET interface and 2 ports; ET200ecoPN 16 DO DC24V/1.3A 8xM12 V6.0 6ES7 142-6BH00-0AB0 V6.0 PROFINET IO compact device; 16 DO DC24V/1.3A 8xM12; 60mm overall width; PROFINET interface and 2 ports; SCALANCE XF204IRT 6GK5 204-0BA00-2BF2 V4.1 4-port switch (4 x RJ45); PROFINET IO device; supports RT/IRT; PROFINET interface and 4 ports;flat; firmware V4.1 SCALANCE XF204 6GK5 204-0BA00-2AF2 V4.1 4-port switch (4 x RJ45); PROFINET IO device; PROFINET interface and 4 ports; flat; firmware V4.1 SCALANCE XF208 6GK5 208-0BA00-2AF2 V4.1 8-port switch (8 x RJ45); PROFINET IO device; PROFINET interface and 8 ports; flat; firmware V4.1 SCALANCE XF206-1 6GK5 206-1BC00-2AF2 V4.1 7-port switch (6 x RJ45 + 1 x FO); PROFINET IO device; PROFINET interface and 7 ports; flat; firmware V4.1 SCALANCE XF204-2 6GK5 204-2BC00-2AF2 V4.1 6-port switch (4 x RJ45 + 2 x FO); PROFINET IO device; PROFINET interface and 6 ports; flat; firmware V4.1 SCALANCE X307-3 6GK5 307-3BL00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X307-3LD 6GK5 307-3BM00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X308-2 6GK5 308-2FL00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP;firmware V3.0 SCALANCE X308-2LD 6GK5 308-2FM00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X308-2LH 6GK5 308-2FN00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X308-2LH+ 6GK5 308-2FP00-2AA3 V3.0 Managed switch with copper ports and optical ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X310FE 6GK5 310-0BA00-2AA3 V3.0 Managed switch with copper ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X310 6GK5 310-0FA00-2AA3 V3.0 Managed switch with copper ports; supports RT; PROFINET interface and 10 ports; MRP; firmware V3.0 SCALANCE X414-3E 6GK5 414-3FC00-2AA2 V3.0 Managed switch with copper ports and additional extended modules (15 slots) ; supports RT; PROFINET interface; MRP; firmware V3.0 SCALANCE X408-2 6GK5 408-2FD00-2AA2 V3.0 Managed switch with copper ports and additional extended modules (8 slots) ; supports RT; PROFINET interface and 8 ports; MRP; firmware V3.0 4

PROFIBUS-DP/PROFINET-IO Modules ET 200S 4SI IO-Link 6ES7 138-4GA50-0AB0 4-channel, serial port for connection of IO-Link devices. Port configuration takes place with the Port Configuration Tool. ET 200S 4SI SIRIUS 3RK1 005-0LB00-0AA0 4-channel, serial port for connection of IO-Link devices. Port configuration takes place with the Port Configuration Tool. ET 200S 2RO NO/NC 24..230V/5A 6ES7 132-4HB50-0AB0 Digital output module 2xrelay Form C UC 24..230V/5A with manual operation ET 200S 2/4 AI RTD ST; 2ch 6ES7 134-4JB51-0AB0 Analog input module 2/4xAI RTD 2ch / 15 bits+sign, standard, R: 150 ohms, 300 ohms, 600 ohms, PTC; RTD: Pt100, Ni100 ET 200S 2/4 AI RTD ST; 4ch 6ES7 134-4JB51-0AB0 Analog input module 2/4xAI RTD 4ch / 15 bits+sign, standard, R: 150 ohms, 300 ohms, 600 ohms, PTC; RTD: Pt100, Ni100 ET 200S 2 AI TC ST 6ES7 134-4JB01-0AB0 Analog input module AI 2xTC / 15 bits+sign, standard, thermocouples: E, N, J, K, L, S, R, B, T 5