digiclip Data sheet DF31DP Special features B en

Similar documents
digiclip Data sheet DF31CAN Special features B en

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

MX590B-R. Pressure amplifier. Special features. Data sheet. Block diagram

U10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en

User Manual AD101B. Digital Transducer Electronics Amplifiers Hardware and Functions. I en

MX1609TB. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

User Manual AED9301B. Digital Transducer Electronics Basic Device PROFIBUS. I en

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

MODEL 9250 Preliminary data sheet

CX27C. Industrial Ethernet Gateway. Special features. Data sheet. Block diagram

User Manual AED9201B. Digital Transducer Electronics Basic Device RS232 or RS485. I en

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

MX809B. Amplifier for thermocouples and voltages (insulated) Data sheet. Special features. Block diagram. Double isolation.

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

Strain Gage Measuring Amplifier GSV-3

Strain Gage Measuring Amplifier GSV-1

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

General information. Display. Supply voltage

GEN series Calibration Kit

MIC-2 Multi-instrument DATA SHEET

General information. Display. Supply voltage

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Quick Start Guide. English. FS22 DI Industrial BraggMETER DI

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Industrial Power Supplies

LVX Control Unit. Features:

General information. Display. Supply voltage. Input current

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

VersaMax IP Input Module

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

VersaMax IP I/O Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

16-Channel Digital Input Termination Card 24Vdc

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Installation Instructions Temperature transmitter TAA /00 06/2011

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

16-Channel Digital Input Termination Card 24Vdc

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

AI561 Analog Input Module

Characteristics and functioning

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

Temperature module. 4 inputs for thermocouples

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

6224 Ethernet-Based Strain Measurement Module

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Data sheet VIPA CPU 115DP (115-6BL22)

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Industrial Power Supplies

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Digital I/O modules. 8 inputs/outputs, M8

GFK-2415A March Type of sensor connection

DI572 Digital Input Module

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

DI561 Digital Input Module

Communication modules. Serial interface module

Isolated Process Current Input with Loop Power 7B35

MINI-PS AC/10-15DC/8

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PHOENIX CONTACT - 07/2006

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

16-Channel Input Digital Input Termination Card

Precision hand-held pressure indicator Model CPH6400

Analog input module. 4 inputs, voltage and current

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

MIC-2 MKII, Multi-instrument DATA SHEET

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Cube20. Application-oriented. Installation-friendly. Efficient

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

IB IL 24 DI 16 IB IL 24 DI 16-PAC

HV-4U for imc CRONOSflex (CRFX/HV-4U)

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

PI-EX-ME-2NAM/COC-24VDC

Transcription:

digiclip DF31DP Data sheet Special features Digital amplifier for industrial automation tasks and production process monitoring 600 Hz CF measurement technology with TEDS sensor detection for SG full bridges Fast peak and limit value monitoring and digital inputs/outputs Accuracy class, typically 0.05% Modular mounting on a DIN EN 60715 type DIN rail (IEC 60715) Standardized Profibus DP interface with DPV1 functionality for parameterization and backup Accessories: Profibus connection module DF001 LED STATUS LED BUS LED Digital IN/OUT Rotary address switch Amplifier module DF31DP Plug-in terminals: transducer Digital IN/OUT PROFIBUS connector terminal / supply voltage B2171-4.0 en

Technical data digiclip Accuracy class (at U B = 2.5 V and U B = 1 V); after autocalibration 0.05 type. 0.1 in an industrial environment as per EN 61326 0.2 in the 10 mv/v measuring range Power supply Supply voltage, Overvoltage and reverse polarity protection V DC 24 Isolation voltage, without transients Potential separation between the supply bus and transducer connection, functional separation, must not be considered for safety aspects V DC < 60 Permissible supply voltage range V 18... 30 Influence of supply voltage on accuracy %/V < 0.001 Power consumption, max.; incl. transducer W 3 Amplifier Carrier frequency rectangle Hz 600 (591.9 Hz 100 ppm) Synchronization when several interconnected modules are used, the carrier frequency is synchronized automatically Bridge excitation voltage UB, Peak to peak ( 10%) V 2,5 1,0 Measuring range mv/v 4 10 Connectable transducers SG full bridge ohms 80... 5000 Connection technique 4 or 6 wire circuitry with single-wire open-circuit monitoring Permissible cable length between transducer and amplifier, max. m 100 Input resistance MOhm 5 Measurement frequency range, adjustable ( 3dB) (see filter table) Hz 0.05... 225 Filter characteristics Bessel, 4th order Noise voltage relative to input, for UB = 2.5 V, typical V/V 1.0 (at filter frequenzy 100 Hz) 0.05 (at filter frequenzy 1 Hz) Influence of ambient temperature for change of 10 K on the zero point (TK0) on sensitivity (TKC) V/V % 0.1 0.05 f.s. Linearity deviation % f.s. 0.005 Long-term drift, without AutoCal % <0.001 (within 48 h) Communication interface Number of devices on the bus, max. Address settings Protocol Bit rate, max. Line length, max. Profibus ID number Parameterization (asynchronous) Profibus connection Signal conditioning A/D converter MBit/s m max. 97, in groups of max. 4, coupled via repeater 3 99 (adjustable via frontal rotary switch) Profibus DP slave, to DIN 19245 2, DPV1 Class 1 and Class 2; available at www.profibus.org 1,5 0,5 0,187 0,093 200 400 1000 1200 096D (hex) to Profibus DPV1 standard Side connector terminal; electrically isolated from supply and measurement ground Option: DF001: 9 pin Sub-D (DIN19245) Delta-Sigma, 24 bit Scaling accuracy bits 32 Sampling rate 1/s 1184 HBM 2

Input of characteristic curve Zero balance Tare balance TEDS, calibration, editing over the entire measuring range over the entire measuring range Duration of balance ms < 2 AutoCal ms < 300 Parameter memory Limit value switches Number Functions Signal source (user-selectable) Hysteresis Update Peak value memory Number Function Update Clearing peak value memory Retaining the current measured value/peak value Current-value memory Digital input ms ms 1 set (plus factory setting); saved in the EEPROM 4 Switching threshold, hysteresis (2-point control), greater than, less than gross, net, max, min, peak to peak adjustable over the entire measuring range at each measured value 3 min., max., peak to peak at each measured value < 2 < 2 Run /Hold Number 1 Switching actions, any combination selectable Response time Active input level can also be selected inverted Flank controlled: Zeroing, taring, peak value memory (min/max) one-off clear Level controlled: Peak value memory (min/max) stop, continuous clear Control action occurs at the latest with the next but one measurement value V 0 or 24 (State of input level displayed by LED) Input voltage range V 0...30 Switching voltages Logic High level Logic Low level one-way fitting V 30... 0 Electrical isolation to supply, transducer and bus potentials Isolation voltage, functional, typ. V 500 Input current at 24V, typ. ma 12 Latency times of electronic digital input when changing from 0V to 24V, typ. when changing from 24V to 0V, typ. Permissible cable length to digital input, max. m 30 Digital output Number 2 Switching actions, any combination can be selected separately for each output Response times Active input level can also be selected inverted separately for each output V V s s >10 <5 200 400 Limit value switch 1 to 4, positive/negative range overrun, overload, measured value invalid Switching action occurs with next measurement value, see Sampling rate ; exception: Measurement value invalid after 300... 700 ms, typ. V 0 or 24 (State of output switch displayed by LED) Output voltage (like supply voltage), nom. V 24 Voltage drop with load, max. V 2 Output currentat operating temperature A 0.5. guaranteed per output Short-circuit current, typ. A 1.1 3 HBM

Short-circuit period Electrical isolation to transducer and bus potentials Isolation voltage, functional, typ. Reference potential like supply voltage Latency times of electronic digital outputs when changing from 0V to 24V, typ. when changing from 24V to 0V, typ. unlimited V 500 Permissible cable length to digital input, max. m 30 Environmental conditions Nominal temperature range o C 0... +50 Operating temperature range o C 10... +60 Storage temperature range o C 20... +70 Permissible rel. humidity, non-condensing % 10... 90 Enclosure s s Material Polyamide PA 6.6 Dimensions (WxHxD) without connections mm 23 x 100 x 114 Weight, approx. g 150 Assembly Support rail, DIN EN60715 (IEC 60715) 240 400 Connection Degree of protection Plug-in terminals IP20 Reliability MTTF (MIL HDBK 217F, Feb. 1995) hours 92800 EMC conformance as per EN 61326 *) in an industrial environment * For measurement as per EN 61326, May 2004 edition, Annex F, burst to shielding of the transducer or bus line, there must be compliance with the class accuracy of 0.1 when using filter frequencies up to and including 2 Hz. When a filter frequency of 100 Hz is used, the measurement variation can be as much as 1.3%. Filter data and sampling rate Desired frequency 1 db (Hz) 3 db (Hz) 20 db (Hz) Phase delay (ms) Sampling rate (s 1 ) 100 Hz 130 225 560 2.3 1184 50 Hz 48 82 220 4.6 1184 20 Hz 20 34 100 9.5 1184 10 Hz 10.5 18.6 56 16.6 1184 5 Hz 5.2 9.3 28 31 592 2 Hz 2.1 3.7 11.2 70 237 1 Hz 1.05 1.8 5.6 140 118 0.5 Hz 0.52 0.9 2.8 280 59 0.2 Hz 0.21 0.36 1.1 700 24 0.1 Hz 0.105 0.18 0.56 1400 12 0.05 Hz 0.052 0.09 0.28 2800 6 HBM 4

Block diagram CF transducer excitation with sense leads 18 30 VDC electrically isolated Supply voltage LED display: Status Bus Digital IN/OUT TEDS AutoCal A D P Intelligent signal conditioning Address switch 03... 99 RAM / EEPROM Electrically isolated Electrically isolated Calibration Linearization Parameter memory Zero balance Min./Max. memory Limit value switch Control inputs/outputs Profibus DPV1 interface Dimensions in mm 45.2 93.1 99 31.05 107 51.8 84.5 6.6 107 DF31DP with DF001 Scope of supply: Module digiclip DF31DP Order No.: 1 DF31DP Coded plug connector for sensor connection (2 pieces) Order No.: 3 3312.0404 Coded plug connector for digital IN/OUT (2 pieces) 24 V / 0 V Order No.: 3 3312.0418 IN / OUT Order No.: 3 3312.0444 Plug-in terminal for PROFIBUS and supply voltage Combicon Order No.: CR MSTB CD ROM with free setup software (digiclip Assistant); (the latest Assistant can be downloaded free of charge under http://www.hbm.com/support) Accessories (not included among the items supplied): Connector set for digiclip module (needed for two-tier installation in the control cabinet) Connection module for frontal assignment of the rear terminal strip (bus and voltage supply) Order No.: 1 digiclip ST Order No.: 1 DF001 5 HBM

HBM 6

7 HBM

Hottinger Baldwin Messtechnik GmbH. Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803-0 Fax: +49 6151 803-9100 Email: info@hbm.com www.hbm.com measure and predict with confidence