RS 485 Mini Modbus 1AO

Similar documents
RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8AO

RS485 MODBUS Module 16I-M

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

RS485 MODBUS Module 8I8RO

RS485 MODBUS Module 6RO

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

RS485 IO Slim Module MOD-ETH

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

NetBiter I/O Extender User Manual

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

RS-485 I/O Modules: ADAM-4000

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

MOD-MUX MODBUS TCP I/O PRODUCTS

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

VPGate Manual PROFIBUS to serial

LAUREL ELECTRONICS, INC.

Hardware Reference IO/5640. Analog/Digital I/O-Extension

iologik R1200 Series User s Manual

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ASTAT XB/XBm Remote Operator

SIC184 Manual Stepper motor servo controller

iologik R1200 Series User s Manual

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

APPLICATION NOTE. OJ-DRHX Modbus protocol OJ DRHX A DRIVES PROGRAMME DEDICATED TO ROTARY HEAT EXCHANGERS /17 (OSH) 2017 OJ Electronics A/S

iologik R1200 Series User s Manual

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Ocean Controls KTA-224 Modbus IO Module

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Features and Benefits. Certifications

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

ProfiPro Distributed PROFIBUS I/O Modules User Manual

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

MDA-8000 DIO User Manual

IFC 100 Supplementary instructions

Process displays For current and voltage

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

FULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL

3 CH Analog Output module / CANopen

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Millenium 3 logic controllers

SSI-1016H Specifications and Operation Manual

TM221CE40T controller M IO transistor PNP Ethernet

Copyright: December 2017 Nidec Issue: E

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

V E2B Snap-in I/O Module

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

I/O Module. Modbus Manual DMB Series.

TM221M16R controller M IO relay

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Remote I/O Modules EH-RIO2 Series

T1K MODBUS Base Controller Specifications

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Winsonic MODBUS Remote IO user manual Rev. 1.0

LVX Control Unit. Features:

Samba PLC+HMI SM35-J-RA22

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

GE Fanuc IC694ALG221. Rx3i PacSystem

Warranty. Warning. Copyright. Contact Us

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

mbc082 Bus Converter

TM221ME32TK controller M IO transistor PNP Ethernet

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

TM221M16TG controller M IO transistor PNP spring

PL400 PROGRAMMABLE LOGIC CONTROLLER WITH INDUCTIVE LOOP DETECTOR

V E1B Snap-in I/O Module

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

TM221CE24R controller M IO relay Ethernet

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

Multifunction Transducer MT440

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

PLC-CPU-CM3-SP Series

NA-9171 / 9173 (RS-232) (RS-485) User Manual. MODBUS Adapter CREVIS Co.,Ltd. Version FnIO MODBUS Adapter NA-9171, NA-9173 FnIO S-Series

MU110-6U. Analog output module 6 channel. User guide

Manual and Protocol Description

XT-9100 Technical Bulletin

I-7000 and M-7000 DIO User Manual

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Energy Management Modular Energy meters Type EM2-96

Programmable Logic Controllers

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

I-7000 and M-7000 DIO User Manual

PGR-3200 MANUAL INSULATION MONITOR

KTA-250 Anemometer Alarm Card

User safety and equipment protection guidelines

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Transcription:

RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for

Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have been prepared with utmost care by our professionals and serve as a description of the product without incurring any liability for the purposes of commercial law. This information does not release you from the obligation of own judgment and verification. We reserve the right to change product specifications without notice. Please read the instructions carefully and follow the recommendations contained therein. WARNING! Failure to follow instructions can result in equipment damage or impede the use of the hardware or software. Version 1.0-14/08/2014 2 z 12

1. Safety rules Before first use, refer to this manual; Before first use, make sure that all cables are connected properly; Please ensure proper working conditions, according to the device specifications (eg: supply voltage, temperature, maximum power consumption); Before making any modifications to wiring connections, turn off the power supply. 2. Module Features 2.1. Purpose and description of the module The MOD-1AO module has 1 current analog output (0-20mA lub 4-20mA) and 1 voltage analog output (0-10V). Both outputs can be used at the same time. The modul is equipped in two digital inputs. In addition, terminals IN1 and IN2 can be used to connect one encoder. Setting the output current or voltage value is done via RS485 (Modbus protocol), so you can easily integrate the module with popular PLCs, HMI or PC equipped with the appropriate adapter. This module is connected to the RS485 bus with twisted-pair wire. Communication is via MODBUS RTU or MODBUS ASCII. The use of 32-bit ARM core processor provides fast processing and quick communication. The baud rate is configurable from 2400 to 115200. The module is designed for mounting on a DIN rail in accordance with DIN EN 5002. The module is equipped with a set of LEDs used to indicate the status of inputs and outputs useful for diagnostic purposes and helping to find errors. Module configuration is done via USB by using a dedicated computer program. You can also change the parameters using the MODBUS protocol. Version 1.0-14/08/2014 3 z 12

2.2. Technical Specifications Power Outputs supply Digital inputs Counters Temperature Connectors Size Voltage Maximum Current No of outputs 2 Voltage output Current output Measurement resolution ADC processing time No of inputs 2 Voltage range Low state 0 High state 1 Input impedance Isolation Input type No 2 Resolution Frequency Impulse Width Work Storage Power supply Communication Inputs and Outputs Configuration Heigth Length Width 10-36 VDC; 10-28 VAC DC: 90 ma @ 24V AC: 170 ma @ 24V 0V do 10V (resolution 1.5mV) 0mA do 20mA ( resolution 5μA); 4mA do 20mA (value in 1000 steps) (resolution 16μA) 12 bits 16ms / channel 0 36V 0 3V 6 36V 4kΩ 1500 Vrms PNP or NPN 32 bits 1kHz (max) 500 μs (min) -20 C - +65 C -40 C - +85 C 3 pins 3 pins 2 x 3 pins Mini USB 90 mm 56 mm 17 mm Interface RS485 UP to 128 devices Version 1.0-14/08/2014 4 z 12

2.3. Dimensions of the product RS485 Mini Modbus 1AO Look and dimensions of the module are shown below. The module is mounted directly to the rail in the DIN industry standard. 34 50 17 56 90 Version 1.0-14/08/2014 5 z 12

3. Communication configuration 3.1. Grounding and shielding RS485 Mini Modbus 1AO In most cases, IO modules will be installed in an enclosure along with other devices which generate electromagnetic radiation. Examples of these devices are relays and contactors, transformers, motor controllers etc. This electromagnetic radiation can induce electrical noise into both power and signal lines, as well as direct radiation into the module causing negative effects on the system. Appropriate grounding, shielding and other protective steps should be taken at the installation stage to prevent these effects. These protective steps include control cabinet grounding, module grounding, cable shield grounding, protective elements for electromagnetic switching devices, correct wiring as well as consideration of cable types and their cross sections. 3.2. Network Termination Transmission line effects often present a problem on data communication networks. These problems include reflections and signal attenuation. To eliminate the presence of reflections from the end of the cable, the cable must be terminated at both ends with a resistor across the line equal to its characteristic impedance. Both ends must be terminated since the direction of propagation is bidirectional. In the case of an RS485 twisted pair cable this termination is typically 120 Ω. Version 1.0-14/08/2014 6 z 12

3.3. Types of Modbus Registers There are 4 types of variables available in the module RS485 Mini Modbus 1AO Type Beginning address Variable 1 00001 Digital Outputs 2 10001 Digital Inputs 3 30001 Input Registers 4 40001 Output Registers Access Bit Bit Read Registered Read Registered Modbus Command 1, 5, 15 2 3 4, 6, 16 3.4. Communication settings The data stored in the modules memory are in 16-bit registers. Access to registers is via MODBUS RTU or MODBUS ASCII. 3.4.1. Default settings Name of parameter Value Address 1 Baud rate 19200 Parity No Data bits 8 Stop bits 1 Reply Delay [ms] 0 Modbus type RTU Version 1.0-14/08/2014 7 z 12

3.4.2. Configuration registers Address Name Values 40002 Module address From 0 to 255 40003 Baud rate 0 2400 1 4800 2 9600 3 19200 4 38400 5 57600 6 115200 other value * 10 40005 Parity 0 none 1 odd 2 even 3 always 1 4 always 0 40004 Stop Bits LSB 1 one stop bit 2 two stop bits 40004 Data Bits MSB 7 7 data bits 8 8 data bits 40005 Response Delay Time in ms 40007 Modbus Mode 0 RTU 1 ASCII 4. Indicators Indicator Description ON LED indicates that the module is correctly powered. TX The LED lights up when the unit received the correct packet and sends the answer. V OUT I OUT The LED lights up when the output voltage is non-zero. The LED lights up when the output current is non-zero. I1, I2 Input state 1, 2 Version 1.0-14/08/2014 8 z 12

5. Module Connection Current Output Power supply Voltage Output Power supply Input Connection Power supply Version 1.0-14/08/2014 9 z 12

6. Modules Registers 6.1. Registered access Address Modbus Dec Hex Register Name Access Description 30001 0 0x00 Version/Type Read Version and Type of the device 40002 1 0x01 Address Module Address 40003 2 0x02 Baud rate RS485 baud rate 40004 3 0x03 Stop Bits No of Stop bits 40005 4 0x04 Parity Parity bit 40006 5 0x05 Response Delay Response delay in ms 40007 6 0x06 Modbus Mode Modbus Mode (ASCII or RTU) 40009 8 0x09 Watchdog Watchdog 40033 32 0x20 Received packets LSB 40034 33 0x21 Received packets MSB 40035 34 0x22 Incorrect packets LSB 40036 35 0x23 Incorrect packets MSB 40037 36 0x24 Sent packets LSB 40038 37 0x25 Sent packets MSB No of received packets No of received packets with error No of sent packets 30051 50 0x32 Inputs Read Input state; Bit is set if value 0 30052 51 0x33 Outputs Read Output state; Bit is set if value 0 40053 52 0x34 Current analog output 1 40054 53 0x35 Voltage analog output 2 40055 54 0x36 Counter 1 LSB 40056 55 0x37 Counter 1 MSB 40057 56 0x38 Counter2 LSB 40058 57 0x39 Counter 2 MSB 40059 58 0x3A CounterP 1 LSB 40060 59 0x3B CounterP 1 MSB Value of analog output: inμa for 0-20mA (max 20480) in for 4-20mA (max 1000) Value of analog output: in mv (max 10240) 32-bit counter 1 32-bit counter 2 32-bit value of captured counter 1 40061 60 0x3C CounterP 2 LSB 40062 61 0x3D CounterP 2 MSB 32-bit value of captured counter 2 40063 62 0x3E Catch Catch counter 40064 63 0x3F Status Captured counter 40065 64 0x40 Default value of 1 analog current output The default of analog output set at power supply and due to activation of watchdog. Version 1.0-14/08/2014 10 z 12

Address Modbus Dec Hex 40066 65 0x41 40067 66 0x42 40068 67 0x43 Register Name Access Description Default value of 2 analog voltage output Current analog output 1 configuration Voltage analog output 2 configuration The default of analog output set at power supply and due to activation of watchdog. 0 OFF 2 current output 0-20mA 3 current output 4-20mA 0 OFF 1 voltage output Current analog output configuration: 40069 40070 68 69 0x44 0x45 Counter Config 1 Counter Config 2 Counters configuration: +1 time measurement (if 0 counting impulses) +2 autocetch counter every 1 sec +4 catch value when input low +8 reset counter after catch +16 reset counter if input low +32 encoder 6.2. Bit access Modbus Address Dec Address Hex Address Register Name Access Description 801 800 0x320 Input 1 Read Input 1 state 802 801 0x321 Input 2 Read Input 2 state 817 816 0x330 Output 1 Read 818 817 0x331 Output 2 Read Current Analog Output state; Bit is set if value 0 Voltage Analog Output state; Bit is set if value 0 993 992 0x3E0 Capture 1 Capture counter 1 994 993 0x3E1 Capture 1 Capture counter 1 1009 1008 0x3F0 Captured 1 Captured value of counter 1 1010 1009 0x3F1 Captured 2 Captured value of counter 2 Version 1.0-14/08/2014 11 z 12

7. Configuration software RS485 Mini Modbus 1AO Modbus Configurator is software that is designed to set the module registers responsible for communication over Modbus network as well as to read and write the current value of other registers of the module. This program can be a convenient way to test the system as well as to observe real-time changes in the registers. Communication with the module is done via the USB cable. The module does not require any drivers USB Cable Modbus Module Configurator is a universal program, whereby it is possible to configure all available modules. Version 1.0-14/08/2014 12 z 12

Table of content 1. Safety rules...3 2. Module Features...3 2.1. Purpose and description of the module...3 2.2. Technical Specifications...4 2.3. Dimensions of the product...5 3. Communication configuration...6 3.1. Grounding and shielding...6 3.2. Network Termination...6 3.3. Types of Modbus Registers...7 3.4. Communication settings...7 3.4.1. Default settings...7 3.4.2. Configuration registers...8 4. Indicators...8 5. Module Connection...9 6. Modules Registers...10 6.1. Registered access...10 6.2. Bit access...11 7. Configuration software...12 Manufactured for: Aspar s.c. ul. Kapitańska 9 81-331 Gdynia POLAND ampero@ampero.pl www.ampero.pl tel. +48 58 351 39 89; +48 58 732 71 73 Version 1.0-14/08/2014 13 z 12