Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Similar documents
Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

NJ-Series Power Supply Unit NJ-PA/PD

NPN output. 200 mm. Type Cable length Model Remarks

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Photoelectric Sensor

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

E2K-X4ME1 2M E2K-X4ME2 2M

Model Number Structure

Model Number Structure

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

Model Number Structure

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

Intelligent Flag Amplifier

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Solid State Relays with Failure Detection Function

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Model Number Structure

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Handheld Reader Writer

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Model NPN output PNP output Standard. configuration

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Model Number Structure

S82S (3/7.5-W Models)

Limit Switch Connectors

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Model Number Structure

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

MGN. Ordering Information. Specifications. Heavy Duty Power Relay. Contact Data. 30 Amp Heavy Duty Relay. Heavy Duty Power Relay MGN 325

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

Limit Switch Connectors

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Conductive Level Controller

CSM_PYF S/P2RF- -S_DS_E_2_5

Number of input channels

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Model A7BS

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Peripheral Devices for Environment-resistive Slaves

Connecting Sockets, Mounting Brackets, DIN Rails

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Ultra Slim Relays 24

DPDT Basic Switch for Two Independent Circuit Control

Photoelectric Sensor

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Model Number Structure

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

PRODUCT SPECIFICATION. PC Board Relays. Series.

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

ZE/ZV/ZV2/XE/XV/XV2. (1) Built-in Switch (3) Actuator (4) Conduit/Ground Terminal *

Electroformed Probe Pins XP3A

Ordering Information. Interface Converter K3SC. List of Models

E4C-UDA CSM_E4C-UDA_DS_E_12_2

With operation indicators **LY2N-CR **LY2ZN-CR

Transcription:

I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2 (H) mm. All Output Relays provide a long endurance (,000,000 operations at A), while all Input Relays provide microswitching power (00 µa at V). Approved by UL and CSA standards. Refer to Safety Precautions for All Relays. Ordering Information Classification Coil rated voltage Model Input (bifurcated contact) SPST-NO 2 VDC -22S (see note 2) 00/0 VAC 200/220 VAC Output (single contact) SPST-NO 2 VDC -2S (see note 2) SPST-NC 2 VDC -02S SPDT 2 VDC -2S Note:. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in Specifications. Example: -2S 2 VDC Rated voltage 2. The -22S and -2S are approved by UL and CSA. Contact your OMRON representative for the coil ratings of other models. The -2S cannot be used in place of the C. The -2S can only be used with the P7TF-0 Socket. Model Number Legend -@@@@S 2 4. No. of Contact Poles 2. Contact Form No indication: Transfer contact Number: Number of NO contacts. Contact Mechanism : Single contact 2: Bifurcated contact 4. Enclosure Construction 2: Casing. Terminal Type S: Plug-in Terminal

Accessories Socket Applicable Relay All I/O Relay and the GTA models. P7TF-0 Model P70 Indicator Module Remove the transparent style strip of the Socket and mount this module. It will function as an operation indicator with surge suppression. Model Applicable Relay coil voltage Remarks For AC Relay P70A 00/0 VAC Surge suppressing system with varistor 200/220 VAC For DC Relay P70D 2/ Surge suppressing system with diode Note:. Order the Indicator Module that is suited to the Relay coil voltage. 2. The Indicator Module for DC Relays has a multiple power supply common to 2 and.. Input current (reference s): 00/0 VAC:.4 to.8 ma 200/220 VAC:.40 to.7 ma 2/: 4.8 to.90 ma Specifications Ratings Coil Ratings (Common to Both Input and Output) Item Rated current Coil Must operate Rated voltage (V) 0 Hz 60 Hz resistance voltage AC 00/0 8.2/9 ma 7/7.7 ma 8,700 Ω 80% max. of 200/220 4./4. ma./.8 ma,00 Ω rated DC 2 42 ma 290 Ω 80% max. of 24 2 ma,0 Ω rated 00/0 ma 20,000 Ω 80% max. of rated Must release voltage 0% min. of rated 0% min. of rated 0% min. of rated Max. voltage 0% of rated 0% of rated 0% of rated Power consumption 0.7 VA 0. W 0. W Note:. The rated current and coil resistance s are measured at a coil temperature of 2 C. Tolerances of AC rated current are +%, 20% and tolerances of coil resistance are ±%. 2. Four rated voltages or currents are available to single AC models used with the P7TF-0 Socket. Only three rated voltages or currents are available, however, when the Relay is used in place of the C.. The operating characteristics s are for a coil temperature of 2 C. 4. The maximum voltage is one that is applicable to the Relay coil instantaneously at 2 C and not continuously. Contact Ratings Item Classification For input For output Resistive load (cosφ = ) Inductive load (cosφ = 0.4, L/R = 7 ms) Resistive load (cosφ = ) Contact mechanism Crossbar bifurcated Single Contact material AgAu-clad Ag AgSnIn Rated load A at 0. A at A at 2 A at 220 VAC Rated carry current A A Max. switching voltage 20 VAC, 2 VDC Max. switching current A A Failure rate (reference ) 00 µa at VDC 0 ma at VDC Inductive load (cosφ = 0.4, L/R = 7 ms) 2 A at A at 220 VAC 2

Characteristics Contact resistance (see note 2) Operate time (see note ) Release time (see note ) Max. operating frequency 0 mω max. ms max. ms max. Mechanical:8,000 operations/hour Electrical:,800 operations/hour (under rated load) Insulation resistance (see note 4) 00 MΩ (at 00 VDC) Dielectric strength Between coil and contacts: 2,000 VAC, 0/60 Hz for minute Between contacts of same polarity:,000 VAC, 0/60 Hz for minute Vibration resistance Malfunction: 0 to to 0 Hz, 0. mm single amplitude (.0 mm double amplitude) Shock resistance Malfunction: 200 m/s 2 Mechanical endurance Electrical endurance (see note ) Error rate (level P) (Reference ) (see note 6) Ambient temperature Ambient humidity Weight 0,000,000 operations Input:0,000,000 operations (0 ma) or 0,000 operations ( A) with resistive load 2,00,000 operations (0 ma) or 20,000 operations ( A) with inductive load Output:,000,000 operations with rated load Input: 00 µa at VDC Output: 0 ma at VDC Operating: 40 C to 70 C (with no icing or condensation) Operating: % to 8% (with no icing or condensation) Approx. 7 g Note:. The above s are all initial s. 2. The contact resistance was measured with A at VDC using the voltage drop method.. The operate and the release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 2 C. 4. The insulation resistance was measured with a 00-VDC megger applied to the same places as those used for checking the dielectric strength.. The electrical endurance was measured at an ambient temperature of 2 C. 6. This was measured at a switching frequency of 20 operations per minute. Socket Ratings Features Easily mounts or dismounts the I/O Relay. Also mounts the Indicator Module (with surge suppressing function). Only 9 mm in width. Terminals corresponding to the NO and NC contacts of a Relay are arranged on top of the Socket to enhance maintainability. Also permits mounting of the GTA Solid-state I/O Relay. Specifications Model P7TF-0 Contact resistance 0 mω max. Dielectric strength 2,000 VAC for minute Insulation resistance,000 MΩ (at 00 VDC) Vibration resistance 0 to to 0 Hz, 0. mm single amplitude (.0 mm double amplitude) Shock resistance,000 m/s 2 Ambient temperature Operating: 0 C to C Ambient Humidity Operating: % to 8% Weight Approx. 28 g

Engineering Data Maximum Switching Power (Output Model with Life of,000,000 Operations) Electrical Endurance Output Relay Input Relay Switching current (A) 0 0 0 0. 0. 0. 0.0 0.0 DC resistive load DC inductive load L/R = 7 ms AC inductive load cosφ = 0.4 AC resistive load Endurance (x 0 4 operations),000,000,000 700 00 00 00 70 0 0 0 7 resistive load inductive load (L/R 7 ms) 220 VAC resistive load 220 VAC inductive load (cosφ = 0.4) Endurance (x 0 4 operations),000,000,000 700 00 00 00 70 0 0 0 7 L/R 7 ms resistive load 0.0 0 0 0 00 00 00,000 Switching voltage (V) 0 2 4 6 7 8 Switching current (A) 0 0 ma 0 ma 00 ma 0. A A Switching Switching current (ma) current (A) 4

Dimensions Note: All units are in millimeters unless otherwise indicated. SPST-NO Type -22S (for input) -2S (for output) 2 max. 9 max. Terminal Arrangement/ (Bottom View) Four, -dia. holes SPST-NC Type -02S (for output) 29 max.. max. Terminal Arrangement/ (Bottom View) 2 max. 9 max. Four, -dia. holes SPDT Type -2S (for output) 29 max.. max. Terminal Arrangement/ (Bottom View) 2 max. 9 max. Four, -dia. holes 29 max.. max. Note: This Relay cannot be used as an I/O relay terminals and must be used in combination with the exclusive P7TF-0 Socket.

Accessories Socket P7TF-0 Dimensions 9 max. Five, M. 8 square screws with washers (Top View) M or M4 screw hole * 7. max. M screw hole 9 max. Note: If the I/O SSR or Indicator Module is used, be aware that the polarity of terminal is positive. * We recommend that you insert washers when mounting with M screws. A washers are not required when mounting with M4 screws. Indicator Module (with Surge Suppressing Function) P70 Dimensions 29. max. 8. max. 2. max. 9 max. Two, -dia. holes Safety Precautions Refer to Safety Precautions for All Relays. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.027. In the interest of product improvement, specifications are subject to change without notice. 6

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2008. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2008 All Right Reserved.