with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING
For the control of energy distribution systems detecting when problems occur that could put the quality and availability of electricity at risk. The wide range of power supply and measurement, high measurement accuracy of electrical parameters and comprehensive expandabilit make these products unique to the market Easy and intuitive menu navigation Graphic display with text in 5 languages Expandability Ethernet, USB, RS232, RS485 and Fieldbus connection High measurement accuracy Wide range of power supply, measurements and temperature Suitable for LV, MV and HV electric systems and installations VERSATILITY, EXPANDABILITY AND HIGH MEASUREMENT QUALITY Digital Power Analyzers Main Features 200 210 300 700 800 900 900T Transducer Modular version 4-module Flush-mount version, 96x96 mm DIN rail fixing version, rear mount Graphic 4-key LCD, 128x80 pixesl Graphic touch-screen LCD, 128x112 pixels Expandability Integrated RS485 interface Number of measured electrical parameters THD (Total Harmonic Distortion) measurement Detail harmonic analysis >160 >160 >344 >160 >344 >590 >590 Certifications obtained: GOST, culus. O Comply with standards: IEC/EN61010-1, IEC/EN61000-6-2, IEC/EN61000-6-3, UL 508, CSA C.22.2 n 14.
Modular Optic interface Compact housing Auxiliary power supply: 100-240V AC/110-250V DC Maximum measured rated voltage: 690V AC L-L (600V AC UL/CSA rating) Input current: 5A (also 1A for 300 only) Voltage measurement range: 20-830V AC L-L Current measurement range: 0.01-6A Frequency measurement range: 45-66Hz 200 and 210 Voltage: ± 0.5% (50-830V AC) Current: ± 0.5% (0.1-1.2 In) Power: ± 1% Active energy: Class 1 (IEC/EN 62053-21) Reactive energy: Class 2 (IEC/EN 62053-23) The 300 interface with the expansion modules is made by infrared beam. Special connectors provide for a solid and secure fixing of expansion modules. The multimeter housing is made to DIN standards The width is just 4 modules. 300 Voltage: ± 0.2% (50-830V AC) Current: ± 0.2% (0.1-1.2 In) Power: ± 0.5% Active energy: Class 0.5S (IEC/EN 62053-21) Reactive energy: Class 2 (IEC/EN 62053-23) DIGITAL MULTIMETER 4 module size The PC for programming and data download takes place in a fast and easy way using the USB port, available on the EXM 10 10 expansion module. Maximum of 3 expansion modules Up to 3 EXM... expansion modules can be fitted on a 300 and permit to: Communicate Control alarms, pulses and tariffs Store events with time stamp. The EXM 10 13 expansion module a lows the 300 multimeter to be connected in a common Ethernet network and viewed by one or more duly-connected system computers. Wiring Diagrams 200: More than 160 measured electrical parameters. 210: More than 160 measured electrical parameters, with RS485 interface 300: More than 344 measured electrical parameters, expandable. Expansion modules for 300 The 300 multimeter can integrate its functions with the use of the following modules: Digital inputs and outputs, static and relay type USB, RS232, RS485 and Ethernet interface communications Data storage with clock calender (RTC) for events. Type of connections: Single-Phase Two-Phase Three-Phase with or without neutral Three-Phase without neutral, ARON connection Balanced Three-Phase, with or without neutral.
Flush-mount expandable digital Auxiliary power supply: 100-40V AC /110-250V DC Maximum measured rated voltage: 690V AC L-L (600V AC UL/CS rating) Input current with CT: 5A only for 700; 5A or 1A for 800/900/900T Voltage measurement range: 20...830V L-L; 10...480V L-N Current measurement range for 5A full scale: 0.01-6A for 700/800; 0.01-10A for 900/900T Current measurement range for 1A full scale: 0.01-1.2A Frequency measurement: 45-66Hz for all type; also 360-440Hz for 900/900T. Wide range of voltage measurement 20...830V AC L-L The wide measurement range of voltage inputs allows multimeters to be used in an infinite number of applications. DIGITAL MULTIMETER 96x96 mm Accuracy 700 800, 900 and 900T Voltage: ± 0.5% (50 830V AC) Voltage: ± 0.2% (50 830V AC) Current: ± 0.5% (0.1-1.2 In) Current: ± 0.2% (0.1-1.2 In) Power: ± 1% Power: ± 0.5% Active energy: Class 1 (IEC/EN 62053-21) Active energy: Class 0.5S (IEC/EN 62053-21) Reactive energy: Class 2 (IEC/EN 62053-23) Reactive energy: Class 2 (IEC/EN 62053-23) DC version 800/900/900T models are also available with 12-24-48V DC. Multiple energy metering with tariff function More than 20 partial energy meters, clearable. DIGITAL POWER ANALYZER 96x96 mm 700: More than 160 measured electrical parameters, expandable. 800: More than 344 measured electrical parameters, expandable. 900: More than 590 measured electrical parameters, expandable. Expansion modules These s can increase their features with the use of the following expansion modules and satisfy the many diverse needs of Customers. They include: Digital inputs and outputs, static and relay type Analog inputs and outputs USB, RS232, RS485, Ethernet and Profibus-DP interface communications Data storage with clock calender (RTC) for events and data logging Data storage with clock calender (RTC) for events, data logging with Energy Quality Multifunction analog inputs and outputs The programmable analog outputs can be configured in voltage or current. The analog inputs can read signals in the form of voltage, current or temperature from PT100 sensor. Ethernet gateway function It allows to read data from a group of s connected together in a RS485 network, using one Ethernet port. Storage module with clock calender It provides for data logging of the measurement trends and storing events and alarms with time stamp. Energy Quality (EN 50160) module It permits to control the energy quality to EN 50160 normative, storing events (micro breakings, voltage dips, etc.) with time stamp. High expandability The EXP expansion modules are common to all the flush-mount models and transducer. The fitting on the multimeters is done with no need of tools and the connection is made with plug connectors.
multimeters and power analyzers Front panel mounting ease The mounting on and removal from the panel door are done with no need of tools. A special fixing system provides a quick and immediate operation during both device installation and removal from the panel front. Programmable alarms with Boolean logic Temperature detection The analog input provides for the temperature measurement by sensors, eg. PT100 MEASUREMENT TRANSDUCER Low-profile housing 700, 800 and 900 types are only 60mm deep (61.5 mm with the terminals covers in place) With the expansion modules mounted, this becomes 80mm. Safety Being equipped with sealable switches, the models can have set-up and clearing locks. To avoid connection tampering, sealable terminal covers are also included. REMOTE DISPLAY UNIT 900T: More than 590 measured electrical parameters expandable, DIN rail fixing. Wiring diagrams 700-800 900RD: Remote terminal for viewing electrical parameters measured by the 900T transducer. 900-900T Five voltage and four current inputs The 900 and 900T types can also provide measurements of neutral current and neutral-earth voltage. Type of connections : Single-phase Two-phase Three-phase with or without neutral Three-phase without neutral, ARON connection Balanced three-phase, with or without neutral Type of connections : Single-phase Two-phase Two-phase with neutral, measurement of neutral current and neutral-earth voltage Three-phase with or without neutral. Three-phase without neutral, ARON connection Balanced three-phase, with or without neutral Three-phase with neutral, measurement of neutral current and neutral-earth voltage.
Series Communications The instruments provide for communications using the following interface: Ethernet. USB. RS232. RS485 and Fieldbus (Modbus. Profibus, etc.) 2 configurable password levels The page with the measurements can be freely consulted while the pages with parameter settings and command are locked with 2 access levels: - User - Installer Wiring Test Page Customising The user can freely define by selecting information and measurement to view on the display. The wiring test allows to check if the multimeter installation has been carried out correctly. Software The new series digital multimeter are compatible with the DMK SW and DMK SW 10 remote control software, already used with the DMK series multimeters. DMK SW The remove control software is capable of supervising up to 250 digital multimeters connected on one single bus. The test permits to check the following points : Reading of the three voltages Readings of the three currents Phase sequence Voltage imbalance Polarity reversal of one or more CTs Phase swap between voltage / current. DMK SW 10 It includes a data-logger supervision software and the DMK SW remote control software. Graphic LCD Screen White backlight with intensity adjustment. Measurement consultation Parameter setting Graphic symbology: Function choice Access status Executing commands Various types of graphs: Histograms for harmonics Measurement range Extensive temperature range display Waveforms -20 + 60 O C Measurement (consumption trends)
Main Parameters and Measurement Inputs Single, Two, Three-Phase Instruments with or without Neutral Voltage (phase, phase-to-phase and system values) Neutral-earth voltage Phase current values Phase current values (actual neutral current) Power Factor (PF) Cos phi for each phase Frequency Max. & Min. value function (HIGH / LOW) for reading and storage of peak voltage, current, power, PF & freq. values. Voltage and current asymmetry Averaging function Peak values (maximum demand) of power and current Hour counter (programmable total and partial) Total harmonic distortion (THD) of voltage and current values O Harmonics analysis of voltage and current up to 31 order O Harmonic analysis of voltage and current up to 63 order Direction of harmonic power flow Active, reactive, apparent, imported and exported energy meters (partial and total) Pulse counter for general use (pulse count for consumption of water, gas, etc. with expansion module only) 3ph+N voltage, 690V AC max 3ph+N+GND voltage, 690-V AC max Measurement 3ph current, CT /5A inputs 3ph current, CT /5A or /1A 3ph+N current, CT /5A or /1A 210 200 300 700 800 Power Analyzers 900 900T Event storage Expandability 200 210 300 700 800 Power Analyzers 900 900T 3 optic modules maximum 4 plug-in modules maximum Digital inputs/outputs Analog inputs/outputs RS232, RS485, USB communications Ethernet communications Profibus-DP communications Data logger + clock calender (RTC) Energy Quality (EN 50160) analysis RS485 built-in interface Sold & Serviced in India by : C-135, Hos. Complex, Phase-II Extn., Noida-201305 (UP) INDIA Tel.: 0120-4221631 to 33 Fax: 0120-4221635 Email : info@naacenergy.com Web : www.naacenergy.com