Application of second-tier VNA calibration. MTT/IMS May 2010

Similar documents
Lecture 10. Vector Network Analyzers and Signal Flow Graphs

Gavin Fisher Cascade Microtech Europe

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use

HP 8714B Calibration

WaferPro Express Key Features What s New in

Agilent 85194K IC-CAP BSIM4 Modeling Package

Configuring a Precision System for On-Wafer Capacitance

White Paper. Abstract

VNA Tools II in the lab practical aspects

1.4 mm Pitch High Frequency Differential, Coaxial PCB Probe (40 GHz)

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note

Agilent PNA Series Microwave Network Analyzers

Improved RSOL Planar Calibration via EM Modelling and Reduced Spread Resistive Layers

Keysight Technologies PNA Series Microwave Network Analyzers

Autonomous RF Measurement assistant

Adapter characterization up to 110 GHz

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note

Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary

Application Note. Pyramid Probe Cards

Orifice Flow Meter

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

LeCroy SPARQ S-Parameter Measurement Methodology

Agilent PNA Series Microwave Network Analyzers

RF Characterization Report

DesignCon Impact of Probe Coupling on the Accuracy of Differential VNA Measurements

RF Probing With Rohde & Schwarz ZNB VNA. PacketMicro, Inc Wyatt Drive, Suite 9, Santa Clara, CA

3M TM VCP TM Package Stripline Two Port Characterization. David A. Hanson Division Scientist 3M Microelectronic Packaging

AKELA Vector Network Analyzer (VNA) Quick Start Guide

TTR500 Series Vector Network Analyzers Demonstration Guide

Microprobing with the Fine-Pitch Active Probe

Advancing Test and Measurement Instrumentation using New Transmission Line Technologies

Agilent USB3, Slide - 1. Agilent. USB3 Test Fixture Characterization. 10 MHz to 20 GHz March 12,

ES 230 Strengths Intro to Finite Element Modeling & Analysis Homework Assignment 5

spinner Measurement & Calibration equipment for network analyzers

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Copyright ANRITSU. All rights reserved.

Ideal for a wide range of applications such as wafer test or PCB test for mm-wave, Microwave, RF or Automotive applications

Autonomous Mobile Robot Design

Impact of DFT Techniques on Wafer Probe

3D Sensing. 3D Shape from X. Perspective Geometry. Camera Model. Camera Calibration. General Stereo Triangulation.

Appendix E: Software

DETERMINING ACCURACY OF AN ABB IRB1600 MANIPULATOR AND FORMING COMMON REFERENCE FRAME WITH A FARO ARM

Techniques for Precise Measurement Calibrations in the Field

High-frequency probes for every application

September 13, 2016 Session 1

c = 6 c 2 = 6 2 Equations of Ellipses - Guided Lesson Explanation Explanation#1 Step1) First we should see what we have find out.

Copyright ANRITSU. All rights reserved.

Paul's Online Math Notes Calculus III (Notes) / Applications of Partial Derivatives / Lagrange Multipliers Problems][Assignment Problems]

We start by looking at a double cone. Think of this as two pointy ice cream cones that are connected at the small tips:

PXI Vector Network Analyzer

3.5mm VNA Calibration Kits

2.92mm VNA Calibration Kits

Deembedding of SiGe multifinger HBTs to. 110 GHz - problems and solutions. Lab. RF Modeling

What s a protocol? What s a protocol? A closer look at network structure: What s the Internet? What s the Internet? What s the Internet?

A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer

TN Vector Network Analyzer Calibrations and Their Effect on Measurement Results. Bernie McDermott. May 2010

Practical hints: splitter characterization. J. Ruefenacht, M. Wollensack, J. Hoffmann, M. Zeier

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive

ANNUAL NATIONAL ASSESSMENT 2015 ASSESSMENT GUIDELINES MATHEMATICS GRADE 7

High performance HBM Known Good Stack Testing

3. Impedance generator installation, functionality, and control

UNIVERSITY OF CENTRAL FLORIDA DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE HEC 406 NANO/MEMS LABORATORY

Precision N Coaxial Calibration Kit

Hello, and welcome to the Texas Instruments Precision DAC overview of DC specifications of DACs. In this presentation we will briefly cover the

2. Use elementary row operations to rewrite the augmented matrix in a simpler form (i.e., one whose solutions are easy to find).

100BASE-T1 EMC Test Specification for ESD suppression devices

Review of New, Flexible MEMS Technology to Reduce Cost of Test for Multi-site Wire Bond Applications

P.J. Matthews and J.J. Song Advanced Photon Source Argonne National Laboratory Argonne, Illinois 60439

3. Preprocessing of ABAQUS/CAE

8 TH GRADE MATHEMATICS CHECKLIST Goals 6 10 Illinois Learning Standards A-D Assessment Frameworks Calculators Allowed on ISAT

Reference Guide. Agilent Technologies Electronic Calibration Modules. RF Two-Port 85091C 85092C 85093C 85096C 85098C 85099C. RF Four-Port N4431B

Contents. PART 1 Unit 1: Number Sense. Unit 2: Patterns and Algebra. Unit 3: Number Sense

User Entry of the Keysight (Agilent/HP) 8510 Calibration Standards Definitions for Millimeter Wave Configuration

ILIA STATE UNIVERSITY LIBRARY GUIDE. Ilia State University Library

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests

Graded Assignment 2 Maple plots

Lesson 19: The Graph of a Linear Equation in Two Variables Is a Line

Overview of CalMAN v3 Calibration Software

Middle School Math Course 3 Correlation of the ALEKS course Middle School Math 3 to the Illinois Assessment Framework for Grade 8

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Machine Tool Alignment Boring Mills, Gantries, Machining Centers, VTLs

This tutorial shows how to use ACE to Identify the true causes of poor response time Document the problems that are found

Magnetic probe holders are fully adjustable for more DUT heights and probe styles

Landing Pages Magento Extension User Guide Official extension page: Landing Pages

How to Search: EBSCO HOST

Eighth Grade Math Assessment Framework Standard 6A Representations and Ordering

ANNUAL NATIONAL ASSESSMENT 2014 ASSESSMENT GUIDELINES MATHEMATICS GRADE 7

Commercial Implementations of Optimization Software and its Application to Fluid Dynamics Problems

Lecture 12 Date:

MintySynth Software Manual v. 4.2

Service Manual. P GHz Active Probe

Muskogee Public Schools Curriculum Map Sixth Grade Math

The compiled VNAView application for Macintosh requires: The NI-VISA driver. LabVIEW 2014 runtime engine. VNAView application.

Advanced Image Combine Techniques

UV-6 Series Double Beam UV/Vis Spectrophotometers

What s a protocol? What s a protocol? A closer look at network structure: What s the Internet? Hardware view: What s the Internet?

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Geometric camera models and calibration

Updated Review Content and Added-on Practice Problems

ONCONTACT MARKETING AND CAMPAIGN USER GUIDE V10

Transcription:

Application of second-tier VNA calibration with Cascade Microtech WinCal XE Craig CagKirkpatrick MTT/IMS May 2010

What is Two Tier Calibration? Two Tier Calibration of a Vector Network Analyzer is a technique that allows two calibration error sets to be combined into one resulting error set for the VNA error correction. This technique solves VNA calibration problems that are not easily solved by one calibration error set alone.

What sort of problem will Two Tier Calibration help me to solve? When you have a device under test that has mixed port connections you will run into a dilemma to complete the calibration with one set of calibration standards. The most common example of a DUT with mixed ports is one with a coaxial port on one side and a probed port on the other side. Another example would be a device with a different probe pitch on each port. The dilemma is finding a Thru calibration standard to use for the calibration of the VNA between such ports. Short, Open, and Load standards for the VNA calibration of the two ports are rather simple. The Thru is the issue. How will I finish my thru calibration!&#$ DUT

Can t I just use S-Parameters of the Thru to complete the calibration? You face the same dilemma, how to measure the S-Parameters of the Thru, assuming a suitable thru exists at all. This is like the Chicken and the Egg; Which came first? For the example of a DUT with a coaxial port and a probed port, you could complete a 2-port VNA calibration if you had the S-Parameters of a second probe to use as the calibration Thru. Even though Cascade Microtech provides S-Parameters for probes we manufacture, your best VNA calibration should include your cable to probe connection, and your VNA sweep setup (number of points, frequencies, IF bandwidth, etc). Effectively the Two Tier Calibration yields the S-Parameters of the Thru, thus solving the dilemma. And you ll see that Two Tier Calibration is a simpler procedure.

Two Tier Calibration Procedure For the common example of a DUT with a coaxial port on one side and a probed port on the other side, here is the procedure: From the front panel of the VNA, complete a full two port coaxial calibration to the ends of the two VNA test port cables using coaxial calibration standards or an electronic calibration module. Connect one VNA test port cable to the probe you are using to contact the probed side of your DUT. Within the WinCal XE calibration menu select Second Tier. And then complete a 1-Port calibration to the tip of the probe using Short, Open, and Load calibration standards. Finish by sending the probe calibration error terms to the VNA, which will combine the existing two port calibration already in the VNA with the additional probe calibration. The result is you have the VNA calibrated now to your two desired reference planes, coax on one side and probe tip on the other side.

How does it work? Marketing: It works great! Engineering: Measurement of three standards, Short, Open, and Load at the tip of the probe provides three (complex) equations with three unknowns (complex): S11, S22, and S12*S21 S21. The last product is pulled apart by square root with a root selection (sign ambiguity) solved by a provided estimate of thru delay and an algorithm that refines the estimate progressively e through the data. The end result is all 4 S- parameters of the probe are determined. It works great!

Step by Step for This Example After finishing the two port coaxial calibration of the VNA from the instrument front panel, proceed with WinCal XE as shown below.

Step by Step for This Example Finish by sending the probe calibration error terms to the VNA, which will combine the existing two port calibration already in the VNA with the additional probe calibration. After this step is complete you are done with the calibration! See how simple it is.

WinCal XE More about this Superior Microwave Tool Visit www.cascademicrotech.com/wincal for more information FREE DEMO VERSION Unlimited data viewing, manipulation and display FREE TRIAL VERSION Fully functional for 30 days Academic discount available Visit our booth for a demo